SOP: Detecting Listeria on Environmental Surfaces with the RapidChek Listeria NextDay System (MFLP-104)

October 23, 2026

Food AnalysisA lateral-flow strip can give an environmental Listeria answer without an instrument. Enrichment in RapidChek Listeria NextDay medium grows viable Listeria species from a sponge overnight and a little beyond, a brief boil releases the sample for testing, and a double-antibody sandwich strip traps the organisms between an immobilised capture antibody and a gold-labelled […]

Read More

SOP: Identifying Vibrio parahaemolyticus Colonies by Real-Time PCR (MFLP-102)

October 23, 2026

Food AnalysisConfirming a presumptive Vibrio parahaemolyticus colony by biochemistry takes a battery of tests. A multiplex real-time PCR collapses that work into about 2 hours by asking three genetic questions at once: is the species marker tlh present, and are either of the virulence-associated hemolysin genes, tdh or trh, carried alongside it? Fluorogenic probes report […]

Read More

SOP: Detecting Listeria on Environmental Surfaces with the 3M Molecular Detection System (MFLP-101)

October 23, 2026

Food AnalysisEnvironmental monitoring lives or dies on turnaround. A molecular screen after a single enrichment day flags a Listeria harborage while corrective cleaning can still matter, whereas culture alone can take days. Loop-mediated isothermal amplification (LAMP) supplies that speed: target DNA copies itself continuously at one temperature, and a bioluminescent signal reports the copying in […]

Read More

SOP: Detecting Salmonella in Foods with the 3M Molecular Detection System (MFLP-100)

October 23, 2026

Food AnalysisMolecular screening shortens the wait for a Salmonella answer without abandoning culture. Enrichment grows viable cells first, loop-mediated isothermal amplification (LAMP) then copies a target sequence at a single temperature, and a bioluminescent readout reports that copying as it happens. Presumptive positives appear in real time, negatives only at the end of the run, […]

Read More

SOP: Counting Total Aerobic Bacteria with Compact Dry TC Plates (MFLP-10)

October 23, 2026

Food AnalysisDry-sheet plates offer a compact alternative to poured agar for routine aerobic counts. A measured volume spreads itself across a dehydrated sheet, turns that sheet to gel in seconds, and grows colonies coloured red by a tetrazolium redox indicator, so counting stays straightforward even in a small laboratory. Ease of handling is the main […]

Read More

SOP: Counting Enterobacteriaceae on 3M Petrifilm EB Plates (MFLP-09)

October 23, 2026

Food AnalysisEnterobacteriaceae counts tell a plant how well hygiene is holding, because the family bundles coliforms together with genuine pathogens such as Salmonella, Shigella and Yersinia in a single hygiene picture. Film plates remove media preparation entirely: nutrients, selective agents, a cold-water-soluble gelling agent and an indicator arrive coated on the plate, ready for a […]

Read More

SOP: Detecting Listeria Species in Foods and on Surfaces with the Assurance GDS System (MFLP-08)

October 23, 2026

Food AnalysisSometimes genus-level knowledge is exactly what a plant needs. A Listeria species hit on a drain or in a dairy product signals conditions that could also shelter L. monocytogenes, long before species identification catches up. Enrichment, magnetic concentration and automated genetic detection deliver that early warning here, with cultural confirmation available whenever a positive […]

Read More

SOP: Detecting Listeria monocytogenes with the Assurance GDS Genetic System (MFLP-07)

October 23, 2026

Food AnalysisGenetic screening shortens the wait for Listeria monocytogenes answers without giving up enrichment. A single food-specific enrichment grows the target first, magnetic concentration then pulls it away from competing flora and food debris, and a sealed-tube amplification reads fluorescence automatically. Speed comes from the instrument; reliability still comes from choosing the right broth and […]

Read More

SOP: Detecting E. coli O157:H7 in Raw Beef with the Atlas EG2 Assay (MFLP-03)

October 23, 2026

Food AnalysisRaw beef carries a zero-tolerance problem, and enrichment plus molecular screening answers it faster than culture alone. Enriched broth feeds a fully automated instrument that captures target messenger RNA, amplifies it isothermally and reads a light signal, so a walk-away run screens many samples while the analyst keeps the matching enrichments warm for culture […]

Read More

SOP: Isolating Listeria monocytogenes from Foods by Two-Stage Enrichment (MFLP-01)

October 23, 2026

Food AnalysisFinding a handful of Listeria monocytogenes cells in a ready-to-eat food takes patience rather than speed. Growth starts in a first enrichment that favours Listeria, a second selective broth then tightens the field, and plating happens from both stages so slow or outnumbered cells still get a chance to form colonies. Identity rests on […]

Read More

SOP: Water Vapour Transmission Rate by Infrared Sensor (ASTM F1249)

October 22, 2026

SOP: Water Vapour Transmission Rate by Infrared Sensor (ASTM F1249) Moisture crossing a packaging film can stale a crisp product, cake a powder or feed mould, and gravimetric cup testing answers that risk slowly, over days of weighing. Infrared sensing answers it directly. Film separates a chamber kept saturated with water vapour from a dry […]

Read More

SOP: Permeation of Organic Vapours and Aroma Compounds through Packaging Films

October 22, 2026

SOP: Permeation of Organic Vapours and Aroma Compounds through Packaging Films Flavour leaves a product in two quiet ways: aroma molecules soak into the packaging layer touching the food, and some keep travelling until they escape outside altogether. Movement runs in reverse too, bringing off-flavours and contaminants inward from board, inks or the storage environment. […]

Read More

SOP: Oxygen Transmission Rate of Whole Packages (ASTM F1307)

October 22, 2026

SOP: Oxygen Transmission Rate of Whole Packages (ASTM F1307) A film result, however careful, still leaves one question unanswered: how much oxygen enters the finished pack, seals, closures and all? Whole-package measurement answers that question directly. One completed, empty package is mounted on a fixture, its inside is washed with nitrogen, and whatever oxygen works […]

Read More

SOP: Thickness of Plastic Film and Sheeting (ASTM D6988)

October 22, 2026

SOP: Thickness of Plastic Film and Sheeting (ASTM D6988) Nearly every other number a packaging laboratory reports leans on thickness. Gas transmission resistance rises directly with it, stiffness and other strength properties shift with it, and density itself is derived from dimensions together with mass. A film whose gauge varies across its width can therefore […]

Read More

SOP: Oxygen Transmission Rate of Plastic Films by Coulometric Sensor (ASTM D3985)

October 22, 2026

SOP: Oxygen Transmission Rate of Plastic Films by Coulometric Sensor (ASTM D3985) Oxygen creeping through a film decides how fast a packed food oxidises, loses colour or goes stale, so a laboratory needs a number for that movement rather than a guess from a resin datasheet. Coulometric measurement supplies that number with unusual sensitivity: every […]

Read More

SOP: Measurement of Oxygen Uptake in Packaged Foods (Shelf-Life Studies)

October 22, 2026

SOP: Measurement of Oxygen Uptake in Packaged Foods (Shelf-Life Studies) Oxygen rarely announces the damage it does. Amounts as small as some tenths of a milligram per kilogram of product can build aldehydes and ketones of extremely high sensory activity, fade a colourant, or strip a vitamin, long before a pack looks any different. Shelf-life […]

Read More

SOP: Melt Flow Rate (MFR) of Thermoplastics (ISO 1133 / ASTM D1238)

October 22, 2026

SOP: Melt Flow Rate (MFR) of Thermoplastics (ISO 1133 / ASTM D1238) Few numbers travel with a packaging resin as widely as its melt flow figure. Converters quote it on purchase specifications, and quality teams reach for it first when a film or container suddenly runs differently on a line. Behind that single value sits […]

Read More

SOP: Vibration Testing of Shipping Containers (ASTM D999 / ASTM D4728; ISO 13355)

October 22, 2026

SOP: Vibration Testing of Shipping Containers (ASTM D999 / ASTM D4728; ISO 13355) Vehicles shake their loads for hours at a time. Road roughness, rail joints, wave action, and air turbulence all feed energy into a vehicle and its suspension, and packages riding inside receive a mixture of that motion: engine, chassis, and suspension vibration […]

Read More

SOP: Vertical Load (Axial Crush) Strength of Glass Containers

October 22, 2026

SOP: Vertical Load (Axial Crush) Strength of Glass Containers Glass carries weight far better than it takes a blow. Stacked cases, a pallet load above them, and capping machinery pressing down on a finish all load a container along its axis, and glass under purely compressive force resists a surprising amount of it. Failure, when […]