SOP: Counting Enterobacteriaceae on 3M Petrifilm EB Plates (MFLP-09)

GIFSQ ID: SOP-0999

Enterobacteriaceae counts tell a plant how well hygiene is holding, because the family bundles coliforms together with genuine pathogens such as Salmonella, Shigella and Yersinia in a single hygiene picture. Film plates remove media preparation entirely: nutrients, selective agents, a cold-water-soluble gelling agent and an indicator arrive coated on the plate, ready for a 1 mL inoculum and a day of incubation.

Reading discipline decides whether numbers mean anything. Only red colonies tied to acid, gas, or both count, and the association rules are precise, down to how far a bubble may sit from its colony before the pair stops counting.

Purpose

Purpose is to enumerate Enterobacteriaceae species in foods and environmental samples, supporting spoilage assessment, faecal contamination indication and post-process recontamination checks on food contact surfaces.

Scope

Scope covers Cheddar cheese, milk, flour, frozen broccoli, frozen prepared meals, nuts and sprouted seeds such as bean and alfalfa sprouts, plus environmental samples. Wider commodity use requires completed validation first, meeting SCC accreditation expectations, before results are reported under this method. Keep samples refrigerated at 2–8°C or frozen according to product nature, thaw frozen samples in a refrigerator or under conditions preventing growth or death, and analyse as soon as possible after receipt. Units may be analysed individually, or combined where the applicable sampling plan’s requirements are still met.

Equipment and Materials

  • 3M Petrifilm Enterobacteriaceae Count Plates (EB Plates) 6420/6421, stored at or below 8°C, with the plastic spreading device supplied in each box, the package insert and the manufacturer’s Interpretation Guide
  • Appropriate sterile diluents: Letheen broth or neutralising broth where sanitisers are present; otherwise Butterfield’s phosphate buffer, 0.1% peptone water, peptone salt diluent, buffered peptone water, or saline solution (0.85–0.90%)
  • Stomacher, blender or equivalent
  • Incubator capable of maintaining 35°C or 37°C
  • pH meter or pH paper distinguishing 0.3 to 0.5 pH units across pH 6.0 to 8.0; 1N NaOH and 1N HCl for adjustment
  • Pipettes or automatic pipettes of 1.0 to 5.0 mL nominal capacity
  • Standard colony counter and/or illuminated magnifier

Procedure

  1. Have sterile diluent ready and disinfect the work surface. Set each Petrifilm plate on a flat surface and mark identifying sample information on the film.
  2. Choose diluent by sample history and never by habit: Letheen broth or neutralising broth where sanitisers may be present in the sample; otherwise Butterfield’s phosphate buffer, 0.1% peptone water, peptone salt diluent, buffered peptone water, or saline solution (0.85–0.90%). Do not use buffers containing citrate, bisulfite or thiosulfate, because they can inhibit growth.
  3. Prepare the analytical unit so it represents the sample: agitate liquids until homogeneous, and take solid portions from several locations within the sample.
  4. Dilute by product type. Milk: plate 1.0 mL directly and/or prepare decimal dilutions in the chosen diluent, mixing each dilution thoroughly. Other dairy products, including chocolate milk, condensed and evaporated milk, heavy and light cream, ice cream and ice mixes, butter, buttermilk, cheese, cottage cheese, dip, sour cream, yogurt and frozen yogurt: prepare at least a 1:10 dilution, for example 11 g in 99 mL of diluent, and/or further decimal dilutions, mixing thoroughly. Solid samples generally: prepare at least a 1:10 dilution in the appropriate diluent and mix thoroughly.
  5. Correct pH on the diluted sample where the product is acidic or alkaline: adjust to pH 6.5–7.5, using 1N NaOH for acid products and 1N HCl for alkaline products, and mix thoroughly afterwards.
  6. Inoculate by lifting the top film and pipetting 1.0 mL of sample or diluted sample onto the centre of the bottom film. Replace the top film by rolling it down carefully so no air bubbles are trapped; never let the top film drop.
  7. Spread the inoculum with the plastic spreader, smooth flat side down, pressing downward on the spreader’s centre to distribute the sample evenly over the growth area. Do not slide the spreader across the film. Leave the plate undisturbed for a minimum of 1 minute so the gel can solidify.
  8. Incubate plates horizontally, clear side up, in stacks of no more than 20 plates, for 24 ± 2 h. Follow current standards for incubation temperature, for example 35°C or 37°C. The test is complete after that 24 ± 2 h incubation.
  9. Protect the plate stock: return unused plates to the foil pouch, seal it by folding and taping the open end, and store the resealed pouch in a cool, dry place, using plates within one month after opening. Exposure above 25°C and/or humidity above 50% RH can affect plate performance. Discard any plates showing orange or brown discoloration unopened. Expiry date and lot number appear on each package, and the lot number also appears on each individual film.
  10. Count plates promptly after incubation. Where immediate counting is impossible, plates may be held in the freezer, though freezing should be avoided as a routine practice.

Recording Results

An indicator in the plate colours all colonies red, and the top film traps gas produced by some bacteria. Count as Enterobacteriaceae only colonies showing acid production, gas production, or both: red colonies with yellow acid zones, red colonies associated with gas bubbles with or without yellow zones, and red colonies producing both gas and acid. A colony separated from its nearest gas bubble by more than one colony diameter, with no yellow zone, is not associated with gas and is not counted. Never count colonies growing on the foam dam, since the dam removes them from the medium’s selective influence. Circular growth area is approximately 20 cm2. On plates holding more than 150 colonies, estimate by counting one or more representative 1 cm2 squares, averaging per square, and multiplying the average by 20 for a total per plate. Where growth is so dense that acid zones and gas bubbles blur, with a lightened gel colour alongside many small colonies or many gas bubbles, record the result as too numerous to count (TNTC). Calculate colonies per mL or per g from plates at dilution levels giving a statistically significant result; on duplicate plates of consecutive dilutions, first compute the mean colony number for each dilution, then determine the average bacterial count. Colonies needed for further identification are recovered by lifting the top film and picking the colony directly from the gel.

Quality Control

Plate integrity is the first control: check expiry, lot and colour before use, and reject discoloured stock. Incubator temperature is held to the stated pattern, a recommended 35°C meaning 35 ± 1.0°C in practice. An interlaboratory collaborative study across 12 laboratories found this plate method comparable to traditional reference methods, which supports its routine use within the validated scope. Any variation in media or diluent from the listed items places equivalency responsibility on the analyst or laboratory supervisor. Use the manufacturer’s Interpretation Guide when reading borderline plates, and keep duplicate plating at consecutive dilutions so the counting rules above can be applied properly.

Troubleshooting

  • Counts unexpectedly low after sanitation sampling: switch the diluent to Letheen broth or neutralising broth so residual sanitiser stops suppressing recovery.
  • Whole plate reads TNTC: report TNTC for that dilution and count a higher dilution; gel lightening with dense small colonies is the giveaway.
  • Bubbles scattered with no clear colonies: apply the one-colony-diameter association rule strictly; distant bubbles do not convert a plain red colony into a count.
  • Colonies crowded past 150: use the representative-square estimate multiplied by 20 rather than forcing a full count.
  • Plates gelling poorly or colours off: check storage history for heat or humidity exposure and discard orange or brown discoloured plates.

Interferences and Limitations

Buffers built on citrate, bisulfite or thiosulfate inhibit growth and invalidate dilutions made with them. Acidic and alkaline samples skew recovery until pH is brought into the 6.5–7.5 band. Heat- and sanitiser-stressed organisms, the very cells environmental monitoring hunts, are the first lost when diluent choice or holding times slip. Counts beyond the validated food list carry no standing until the commodity is validated.

Safety Notes

  • Treat plates and samples as potentially carrying enteric pathogens, including Salmonella and Shigella; use standard enteric precautions and biohazard disposal after counting.
  • Handle 1N NaOH and 1N HCl for pH adjustment with gloves and eye protection.
  • Keep the work area disinfected before and after plating, and decontaminate stomacher and blending equipment between samples as general laboratory practice requires.

Source Method

Adapted in original wording from Health Canada method MFLP-09, Enumeration of Enterobacteriaceae Species in Food and Environmental Samples Using 3M™ Petrifilm™ Enterobacteriaceae Count Plates, June 2007, Compendium of Analytical Methods, Volume 3.