SOP: Counting Total Aerobic Bacteria with Compact Dry TC Plates (MFLP-10)
GIFSQ ID: SOP-1000
Dry-sheet plates offer a compact alternative to poured agar for routine aerobic counts. A measured volume spreads itself across a dehydrated sheet, turns that sheet to gel in seconds, and grows colonies coloured red by a tetrazolium redox indicator, so counting stays straightforward even in a small laboratory. Ease of handling is the main attraction, alongside an ability to lift a colony straight from the sheet for follow-up work.
Versatility matters here as well. Liquids go on directly, solids follow a buffer homogenisation step, and swab rinses adapt a surface sample to the same format. Plates can also double as contact plates for awkward areas when used with a matching swab device.
Purpose
Purpose is enumeration of total viable aerobic bacteria in food products and food ingredients using Compact Dry TC, a ready-to-use chromogenic dry plate carrying nutrient standard agar.
Scope
Scope covers raw materials and finished products, including food, beverage, meat and cosmetic-type matrices named in the source application, plus swab specimens from surfaces. Counts are viable counts only: organisms that fail to grow and form a visible colony under the incubation conditions chosen are not measured. Incubation temperature and time follow the legal specification for food analysis in the country where results will be used, so a laboratory must set those conditions from its own applicable regulation before starting.
Equipment and Materials
- Compact Dry TC kits, stored at room temperature, with the package insert and instructions for use
- Incubator capable of maintaining temperatures in the 20 to 42°C range
- Buffer solution for homogenising solid foods; stomacher or equivalent homogeniser
- Swab device for surface work: Swab for Compact Dry offered by HyServe, Id-No. 1 002 952/3, recommended for swab specimens
- Standard colony counter; magnified illuminator as an aid to counting
- White paper to place under plates during counting; sterile pipetting supplies for 1 mL transfers and any dilutions
Procedure
- Prepare the specimen by type. For water or a liquid foodstuff, take 1 mL directly, diluting beforehand when a high count is expected. For a solid foodstuff, add buffer solution and homogenise in a stomacher, then take 1 mL of the homogenate, diluted as needed. For a swab specimen, wipe the surface, return the swab to its device with wiping solution, and take 1 mL of that solution, diluted as needed.
- Open the cap of a Compact Dry plate and drop 1 mL of specimen onto the middle of the dry sheet.
- Allow spreading to happen on its own. Liquid diffuses automatically and evenly across the sheet and converts the dried sheet into a gel within seconds; do not spread manually.
- Replace the cap and write identifying information on the memorandum section of the plate.
- Invert each capped plate and place it in the incubator for 48 hours at the incubation temperature required by the applicable legal specification.
- Count promptly once incubation ends. Examine plates from underneath, with white paper placed below to improve contrast, using a standard colony counter or a magnified illuminator where helpful.
- Pick colonies for further identification when needed by lifting the cap and removing the colony directly from the plate.
Recording Results
Count every red dot, regardless of size or intensity. Almost all colonies on Compact Dry TC appear red; red colonies plus any otherwise coloured colonies together make up the total count. Growth area is approximately 20 cm2, and the back of each plate carries a carved 1 cm x 1 cm grid. On plates holding more than 250 colonies, count one or more representative squares, average the count per square, and multiply that average by 20 for an estimated total per plate. Calculate colonies per mL or per g from plates at dilution levels giving a statistically significant result. Where duplicate plates at consecutive dilutions are counted, first compute the mean colony number for each dilution, then work out the average bacterial count from those means. Record an overcrowded result as too numerous to count (TNTC) in two situations: very high concentrations turn the entire growth area red or pink, or the centre of the plate shows no visible colonies while small colonies appear at the edges. TNTC plates call for further dilution and a repeat. If counting cannot happen immediately after incubation, plates may be stored in a freezer, although doing so routinely should be avoided.
Quality Control
Compact Dry plates are produced at an ISO 9001 certified site, and the Compact Dry TC method carries AOAC approval No. 010404. Read the package insert before a run, keep kits at room temperature as directed, and process dilution blanks and duplicate plates as ordinary laboratory practice requires so that a spreading or pipetting error shows up in the data rather than passing silently. Verify incubator temperature against the legal specification adopted for the run, because the source method deliberately leaves that setting to national regulation.
Troubleshooting
- Whole growth area turned red or pink: concentration is too high for a direct count; dilute the sample further and repeat, reporting the first plate as TNTC.
- Centre empty, edges crowded with small colonies: treat as overcrowding rather than a low count; record TNTC and test a higher dilution.
- Colonies hard to distinguish: count from underneath against white paper and use a colony counter or magnified illuminator; use the 1 cm grid and the by-20 estimation rule when numbers exceed 250.
- Colonies not clearly red: include otherwise coloured colonies in the total, as a minority may not show a clear red colour.
- Gel liquefied and colonies spread: some organisms liquefy the gel and obscure neighbours; make an estimated count from unaffected areas.
Interferences and Limitations
Gel-liquefying organisms interfere most directly, spreading across the sheet and hiding other colonies, leaving only an estimate from unaffected zones. Colour variation also limits certainty: most colonies are red, yet some are not clearly red, so colour alone never decides whether a colony counts. Crowding removes accuracy at the top end, and any plate beyond the countable range yields TNTC rather than a number. Results depend on the incubation temperature and time chosen under national rules, so counts from laboratories using different legal specifications are not automatically comparable.
Safety Notes
- Handle all foods and enrichments as potentially carrying pathogenic bacteria; use gloves, eye protection and standard microbiological aseptic technique throughout.
- Dispose of used plates following current disposal regulations, as the source method directs, treating grown plates as biohazardous waste.
- Take care with hot buffer, stomacher operation and freezer storage of plates as ordinary laboratory practice requires.
Source Method
Adapted in original wording from Health Canada method MFLP-10, Enumeration of Total Aerobic Bacteria in Food Products and Food Ingredients Using Compact Dry Aerobic Count Plates, December 2007, Compendium of Analytical Methods, Volume 3.