SOP: Detecting Listeria on Environmental Surfaces with the RapidChek Listeria NextDay System (MFLP-104)
GIFSQ ID: SOP-1004
A lateral-flow strip can give an environmental Listeria answer without an instrument. Enrichment in RapidChek Listeria NextDay medium grows viable Listeria species from a sponge overnight and a little beyond, a brief boil releases the sample for testing, and a double-antibody sandwich strip traps the organisms between an immobilised capture antibody and a gold-labelled second antibody. Two red lines mean presumptive positive, one control line means negative.
Gold reagent that flows past the test line is caught at a control line, so every valid strip proves its own flow happened. That built-in check shapes the reading rules below, including what to do when a control line refuses to appear.
Purpose
Purpose is detection of Listeria species in a variety of environmental surface samples with the RapidChek Listeria NextDay system, giving presumptive results after a minimum 27 h enrichment for compliance and monitoring work.
Scope
Scope covers environmental surface samples collected with cellulose sponges, validated for a variety of environmental surfaces. Collection devices are moistened with 10 mL D/E Neutralizing broth, and collection and transportation follow standard environmental sampling practice for microorganism detection. Detection is at genus level for viable Listeria species and is presumptive when positive; confirmation follows the cultural route described in the Procedure. In the laboratory, keep sample units refrigerated before analysis and analyse as soon as possible after receipt.
Equipment and Materials
- RapidChek Listeria kit, 45 tests, including transfer tubes and graduated pipettes (10001695), or RapidChek Listeria NextDay Environmental System, 4 × 45 tests, with media (10001723)
- RapidChek Listeria Test Combs, 384 tests, supplied as 8 desiccated foil bags containing 6 combs of 8 strips each (10001721)
- RapidChek Listeria NextDay media (500 g, 10001409; 5 kg, 10001410), prepared and sterilised following manufacturer instructions
- Stomacher or equivalent, and stomacher bags
- Incubator capable of maintaining 30°C; water bath or heat block capable of maintaining 95–100°C
- Control cultures: positive controls Listeria monocytogenes (e.g. ATCC 19115) and Listeria innocua (e.g. ATCC 33090); negative control e.g. Enterococcus faecalis (ATCC 19433)
- D/E Neutralizing broth for moistening sponges; work is to be done in line with ISO/IEC 17025 requirements, and any variation in a listed medium formulation needs an equivalency demonstration by the laboratory using it
Procedure
- Ready the bench: have sterile medium prepared in advance and acclimatised to room temperature before use, and clean the working surface with a suitable disinfectant.
- Add 60 mL of prepared RapidChek Listeria NextDay media to each environmental sponge, or 600 mL of medium for a composite sample of 10 sponges. Make sure the medium completely covers the sponge or sponges.
- Stomach or hand massage as required for thorough mixing.
- Close the bag loosely and incubate for 27–40 h at 30°C.
- Transfer 400 µL of enrichment to a supplied transfer tube. Return the remaining enrichment to the incubator for use in confirmation as required, noting that primary enrichment may be used for confirmation up to a maximum of 48 h incubation.
- Place the transfer tube in a boiling water bath or heat block at 95–100°C for 5 to 15 minutes. Remove the tube and cool it to room temperature before testing.
- Insert a test strip, arrows facing down, into the transfer tube. Allow the strip to develop for 10 minutes in the tube, then remove the strip and read and interpret the result without delay.
- Confirm presumptive positives culturally from the unboiled enrichment. Plate the 27 h RapidChek Listeria NextDay enrichment broth directly onto selective agars used for cultural Listeria isolation, and at the same time transfer an aliquot of the same primary enrichment into modified Fraser broth (MFB). If direct plating confirms the result, the selective secondary enrichment can be stopped. If direct plating is negative, continue with enrichment incubation, plating, isolation and confirmation through to completion of the cultural method.
Recording Results
Judge the strip at the 10 minute read time by its two lines. A test counts as working correctly only when a distinct red line appears on the control line within 10 min. A sample is presumptive positive when, at or before the read time, a red line appears in the test line zone together with the control line, two lines in total. A sample is negative when no red line appears on the test line but a distinct control line appears within 10 min of sample application, one line in total. A missing control line breaks the usual reading: discard the test device and repeat with a new test kit, and if the control line still does not appear with that second kit, treat the sample as presumptive positive and proceed with confirmation. Record site and device, enrichment time within the 27–40 h window, boil and development times, line pattern observed, control-culture behaviour, and the confirmation disposition of every presumptive positive, keeping the primary enrichment available until its 48 h confirmation limit passes.
Quality Control
Run the listed control cultures with the system: Listeria monocytogenes and Listeria innocua as positives and Enterococcus faecalis as the negative example. Every strip carries its own internal control in the control line, which captures excess gold reagent passing the test line; flow that fails to produce a control line fails the strip. Temperature discipline is part of control: where a growth temperature of 37°C or below is specified the tolerance is ± 1.0°C, while higher temperatures must be held within 0.5°C because of potential lethality to the organism being isolated. Keep test combs in their desiccated foil bags until use, as ordinary kit practice requires, so moisture does not degrade strips before testing.
Troubleshooting
- No control line on a strip: discard that device and repeat with a new test kit; if the second kit also shows no control line, treat the sample as presumptive positive and go to confirmation.
- Weak or late test line: read only at or before the 10 minute development time; check that enrichment ran a full 27 h minimum at 30°C and that the boiled aliquot cooled to room temperature before strip insertion.
- Sponge not fully covered by medium: coverage is a stated condition: add the full 60 mL per sponge, or 600 mL for a 10-sponge composite, so every part of the sponge sits in medium.
- Positive strip, negative direct plates: do not close the sample; continue the modified Fraser broth secondary enrichment, plating, isolation and confirmation to completion.
- Confirmation needed after a delay: use the retained primary enrichment only within its maximum 48 h incubation for confirmation; beyond that window the confirmation basis is lost.
Interferences and Limitations
Detection is genus-level for Listeria species; a positive strip does not by itself prove Listeria monocytogenes, and speciation comes from cultural confirmation. Growth is required, so organisms that fail to multiply in NextDay medium during 27–40 h at 30°C will not be seen, and a shortened enrichment undermines the minimum 27 h basis for a presumptive result. Compositing 10 sponges pools sites together, so a positive composite identifies a zone rather than a single point. Strip flow failure removes the internal check altogether, which is why a persistently absent control line defaults to presumptive positive rather than negative.
Safety Notes
- Treat enrichments as potentially carrying Listeria monocytogenes; use gloves and standard precautions for a pathogen that is a particular risk in pregnancy, and disinfect the work surface before analysis as directed.
- Take care with the boiling water bath or 95–100°C heat block and with hot transfer tubes; cool tubes fully before inserting strips and handling them further.
- Dispose of strips, tubes, sponges and enrichments as biohazardous laboratory waste following local rules, as generic laboratory practice requires.
Source Method
Adapted in original wording from Health Canada method MFLP-104, RapidChek Listeria NextDay System for the Detection of Listeria Species in a Variety of Environmental Surface Samples, February 2020, Compendium of Analytical Methods, Volume 3. This issue replaces MFLP-104 dated December 2017.