Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

SOP: Detecting Listeria Species in Foods and on Surfaces with the Assurance GDS System (MFLP-08)

GIFSQ ID: SOP-0998

Sometimes genus-level knowledge is exactly what a plant needs. A Listeria species hit on a drain or in a dairy product signals conditions that could also shelter L. monocytogenes, long before species identification catches up. Enrichment, magnetic concentration and automated genetic detection deliver that early warning here, with cultural confirmation available whenever a positive needs a name.

One workflow serves every matrix in this method, which keeps bench work simple. Variation lives entirely in the enrichment table: broth, temperature and hours change by food and surface, while concentration and amplification stay identical.

Purpose

Purpose is the rapid detection of Listeria species in specified foods and environmental surfaces, as a hygiene and contamination indicator. Cultural confirmation of presumptive positives may be performed where species-level information is required.

Scope

Scope covers heat processed and frozen dairy products, ready-to-eat meat and poultry, leafy greens within raw and raw processed fruit and vegetable products, and stainless steel, plastic and rubber environmental surfaces. Application to other foods or surfaces needs prior validation against Compendium criteria. Keep units refrigerated or frozen by product type, thaw under conditions preventing growth or death, and analyse as soon as possible after receipt. Assay selectivity is high by design, targeting a conserved Listeria DNA sequence and avoiding organisms that cross-react in antibody-based assays.

Equipment and Materials

  • Assurance GDS Listeria spp. Tq kit (Catalogue no. 71009-100, 100 tests): Amplification Tubes Tq with lyophilised reagents and internal positive control, Resuspension Buffer Tq, Sample Concentration Reagent, Wash Solution
  • Demi-Fraser broth; Buffered Listeria Enrichment Broth with lithium chloride and PALCAM Antimicrobic Supplement (BLEB+LiCl+Palcam)
  • Assurance GDS Rotor-Gene system with computer and software; Assurance GDS Sample Concentration Device (PickPen or equivalent); Assurance GDS Vortex Mixer
  • Sample wells and sample well base; resuspension plate; cooling block, aluminium or gel; adhesive sealing film
  • Pipettors; filter-barrier tips, 50 µL and 1 mL; repeat pipettor tips, 0.5 mL and 10 mL; PickPen tips
  • Stomacher, blender or equivalent; incubators maintaining 30 ± 1°C, 36 ± 1°C and 60 ± 2°C
  • Sampling sponges, swabs and bags; D/E (Dey/Engley) broth or Letheen broth; plating and confirmation media for cultural follow-up; positive and negative control cultures, for example ATCC strains

Procedure

  1. Prepare a representative unit: agitate liquids and free-flowing materials until homogeneous, and take solid portions from several locations within the unit. Pre-warm enrichment broth to 36 ± 2.0°C before use.
  2. Set up foods at 25 g or mL into 225 mL of the assigned enrichment medium in a blender jar or stomacher bag, blending, stomaching or vortexing as needed for thorough mixing. Alternate unit sizes hold a 1 in 10 dilution, 1 part food to 9 parts broth. Composites may combine units up to 125 g or mL, for example 125 g in 1125 mL of broth.
  3. Set up environmental samples from sponges or swabs hydrated with D/E broth or Letheen broth. Add each sponge to 100 mL and each swab to 10 mL of the assigned enrichment medium, masticating sponges to mix well. Compositing may combine up to 10 swabs at 10 mL of broth per swab, or up to 10 sponges at 100 mL of broth per sponge. Sponges and swabs hydrated with neutralising buffer are not recommended for this assay.
  4. Enrich by matrix exactly as assigned. Heat processed and frozen dairy products except soft cheese: BLEB+LiCl+Palcam at 30°C for 30–48 h. Soft cheese: Demi-Fraser broth at 30°C for 30–48 h. Leafy greens: Demi-Fraser broth at 30°C for 36–48 h. Ready-to-eat meat and poultry: Demi-Fraser broth at 30°C for 36–48 h. Stainless steel, plastic and rubber surfaces: BLEB+LiCl+Palcam at 36 ± 1°C for 18–24 h, or alternatively Demi-Fraser broth at 30°C for 36–48 h.
  5. Begin concentration: vortex the Sample Concentration Reagent, set well strips into a sample well base, and immediately dispense 20 µL into one well per sample using a repeat pipettor with a 0.5 mL tip, sealing wells with adhesive film. Dispense 1.0 mL of Wash Solution into a second well per sample using a 10 mL tip, and seal those wells as well.
  6. Add enriched sample one strip at a time: peel film from a reagent strip, add 1.0 mL of incubated sample per well while avoiding food particles, fit a fresh pipette tip for every sample, and reseal each strip before opening another. Return enrichment broths to the incubator immediately so they remain available for confirmation.
  7. Give BLEB-enriched environmental samples their extra hold: stainless steel, plastic and rubber samples enriched in BLEB+LiCl+Palcam incubate as the sealed block containing 1.0 mL of sample for 4–8 h at 30 ± 1°C before continuing. Every other sample, including environmental samples enriched in Demi-Fraser broth, proceeds directly.
  8. Vortex the sealed sample wells on the Assurance GDS Vortex Mixer at 900 rpm for 10–20 minutes, adjusting speed where necessary so liquid never contacts the adhesive film.
  9. Prepare the resuspension plate with 45 µL of Resuspension Buffer Tq per well using a repeat pipettor and 0.5 mL tip, then seal it with adhesive film.
  10. Capture and wash with the PickPen, row by row, with fresh tips for each row and tips seated firmly on the tool. Extend the magnets, enter the sample well, and stir gently for 30 seconds while moving constantly from surface to bottom; tap tips against the well side to shed excess medium. Move into the matching Wash Solution well, stir submerged from side to side for 5–10 seconds, and tap off excess wash. Finish in the matching resuspension well: retract the magnets with tips submerged and tap gently to release particles into the Resuspension Buffer Tq.
  11. Seal the completed resuspension plate and incubate it at 60 ± 2°C for 15 minutes to 1 hour.
  12. Amplify and detect. Prepare the gel cooling block before first use by storing it in a freezer at −25 to −15°C for a minimum of 6 hours; a colour change signals readiness, and the block stays in the freezer when idle and returns there between uses until the colour returns, which may take up to 2 hours. Place Amplification Tubes Tq from the foil pouch into the frozen block, reseal the pouch, open the tubes, and transfer 30 µL from each resuspension well into its tube, pressing each lid firmly closed. Load tubes into the Assurance Rotor-Gene in sequential order starting at position 1 and start the program within 15 minutes of adding samples. Never open amplification tubes once PCR has started, under any circumstances.

Recording Results

Software closes the run with a results table calling each sample Positive, Negative or No Amp. Positive means the sample is positive for Listeria spp., Negative means negative for Listeria spp., and No Amp means amplification did not occur: repeat the analysis beginning again at the sample concentration stage. Where species identification is wanted, confirm presumptive positives culturally from the retained enrichment: direct plating onto the selective agars of a cultural method such as MFHPB-30, with a parallel aliquot transferred into modified Fraser broth as secondary enrichment. Primary enrichment incubation continues to 48 h, the 48 h enrichment is also streaked to selective agars with a parallel MFB transfer, and isolation and confirmation proceed under that cultural scheme. Record broth, enrichment temperature and duration, and any compositing beside each result.

Quality Control

Every reaction tube carries a procedural control read in its own fluorescence channel at the same time as the target, so amplification failure is visible rather than silent. Positive and negative control cultures run with the assay, and enrichment broths are held in the incubator, not discarded, until results are known. Temperature tolerances follow the house pattern: 30°C and 25°C steps allow ± 1.0°C, a stated 35°C runs at 35 ± 1.0°C, and higher temperatures hold within 0.5°C unless the method states otherwise, a point that covers the 36 ± 1°C environmental enrichment. Media variations require demonstrated equivalency, and work follows ISO/IEC 17025 competence requirements.

Troubleshooting

  • No Amp result: repeat from sample concentration with fresh wells and tips; do not report the sample as negative on a failed amplification.
  • Film wetted during vortexing: reduce mixer speed below 900 rpm until liquid clears the film, then repeat affected wells to avoid cross-contamination.
  • Environmental positive with no food positive: treat as a genuine hygiene signal, resample the surface and consider cultural confirmation to species level rather than dismissing the result.
  • Suspect sampler chemistry: verify hydration used D/E or Letheen broth; neutralising buffer hydration is not recommended and weakens confidence in a negative.
  • Enrichment broth discarded early: the run cannot be confirmed; repeat sampling and hold broths until the results table is final next time.

Interferences and Limitations

Validation is confined to the foods and surfaces named in the Scope, so wider use awaits commodity-specific validation. Results speak at genus level only: a positive establishes Listeria species presence, not L. monocytogenes, until culture identifies the isolate. Particulate carryover into sample wells and pooled environmental composites both dilute interpretive precision, composites by design and particles by accident.

Safety Notes

  • Handle enrichments as potentially carrying pathogenic Listeria, including L. monocytogenes; apply pathogen precautions and biohazard disposal throughout.
  • Keep amplification tubes sealed after the run and dispose of them unopened to protect the laboratory from amplicon contamination.
  • Use routine thermal care around the 60°C incubation and cold care when handling the freezer-stored gel block.

Source Method

Adapted in original wording from Health Canada method MFLP-08, The detection of Listeria species in foods and environmental surfaces using the Assurance® GDS Listeria spp. Tq Genetic Detection System, January 2018, Compendium of Analytical Methods, Volume 3. This revision replaces MFLP-08 dated June 2012.