Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Food Analysis Methods and Laboratory Procedures

Explore scientific laboratory methods and practical analytical procedures used in food science and technology. This section provides technical resources covering physical, chemical, microbiological, nutritional and sensory analysis of food products.

SOP: Screening for Enterobacter sakazakii with the BAX System (MFLP-27)

October 23, 2026

Food AnalysisPowdered infant formula tolerates no casual screening, because Enterobacter sakazakii (the organism now also classified as Cronobacter sakazakii, named Enterobacter sakazakii throughout the source) can persist in dry product and grow once rehydrated. A two-stage enrichment, first hot and selective, then brief and nutrient-rich, lifts numbers before a closed-tube PCR assay reads presence or […]

Read More

SOP: Detecting Shigella in Foods by PCR Targeting the ipaH Gene (MFLP-26)

October 23, 2026

Food AnalysisSpeed means little if a PCR assay cannot tell its target apart, and here specificity comes from one well-chosen locus. Amplification aims at a 629-base-pair fragment of the ipaH gene, carried on both the large invasive plasmid and the chromosome of Shigella spp., so plasmid loss alone does not erase the signal. Enriched broth […]

Read More

SOP: Isolating and Identifying Shigella in Fresh Produce and Salads (MFLP-25)

October 23, 2026

Food AnalysisFresh produce carries Shigella at low numbers and without a heat step to thin competitors, so enrichment has to favour a fragile, non-motile organism that many routine enteric workflows overlook. Novobiocin-suppressed Shigella broth under carbon dioxide, followed by plating across agars of differing selectivity, gives colonies a chance to appear before biochemistry and serology […]

Read More

SOP: Counting Staphylococcus aureus in Foods and Environmental Samples on Petrifilm Staph Express Plates (MFLP-21)

October 23, 2026

Food AnalysisPouring Baird-Parker plates for every Staphylococcus aureus count eats media, incubator space and analyst time. Petrifilm Staph Express (STX) plates arrive ready-made: a chromogenic modified Baird-Parker medium and a cold-water-soluble gelling agent are coated on film, so the analyst adds sample, spreads it, incubates and counts. Validation and collaborative studies behind this procedure found […]

Read More

SOP: Detecting Listeria monocytogenes in Raw Meat and on Stainless Steel with the GeneQuence DNA Hybridization Assay (MFLP-14)

October 23, 2026

Food AnalysisConfirming Listeria monocytogenes by culture alone keeps a laboratory waiting while product sits in limbo. GeneQuence offers a faster presumptive answer: enriched cells are lysed, species-specific DNA probes capture the organism’s ribosomal RNA on a microwell plate, and a colour change read at 450 nm signals presence or absence. Sensitivity reaches as little as […]

Read More

SOP: Rapid Gene-Based Screening for E. coli O157:H7 in Foods with the Assurance GDS System (MFLP-16)

October 23, 2026

Food AnalysisShiga-toxigenic Escherichia coli O157:H7 demands a fast screen that does not confuse look-alikes. Assurance GDS builds selectivity into its primers and probes, aimed at a highly conserved target sequence, so O157 organisms lacking H7 or NM status and unrelated organisms carrying O157 antigen stay silent where antibody assays might react. Concentration does heavy lifting […]

Read More

SOP: Identifying Yersinia enterocolitica Colonies by Real-Time PCR (MFLP-118)

October 23, 2026

Food AnalysisConfirmation need not wait for biochemical panels. A presumptive colony from a validated agar can be named within 2 hours by multiplex real-time PCR hunting two Yersinia enterocolitica targets: outL, coding for outer membrane protein L, a species marker, and ail, the attachment and invasion locus, a second species marker and major virulence marker. […]

Read More

SOP: Detecting E. coli O157 (Including H7) in Raw Meats with the Neogen Molecular Detection System (MFLP-116)

October 23, 2026

Food AnalysisIsothermal chemistry changes the shape of a pathogen screen. Loop-mediated isothermal amplification (LAMP) holds one temperature while multiple primers and a strand-displacing Bst polymerase copy target DNA continuously, past 109 copies in as little as 15 minutes. Pyrophosphate released during copying feeds a two-step light reaction, so the instrument watches bioluminescence rise in real […]

Read More

SOP: Detecting E. coli O157:H7/NM in Meats, Dairy and Produce with the BAX Real-Time PCR System (MFLP-115)

October 23, 2026

Food AnalysisSpeed matters with Shiga toxin-producing Escherichia coli O157:H7, yet enrichment still decides whether a screen succeeds. Ground beef, raw milk cheese or cut lettuce first multiplies in warm broth, and only then does a closed-tube real-time PCR look for a target fragment carried by H7 strains, including non-motile variants that a motility check would […]

Read More

SOP: Rapid PCR Screening for Listeria Species on Environmental Surfaces (MFLP-112)

October 23, 2026

Food AnalysisSpeed comes from pairing one enrichment day with a real-time PCR read. Sponges and swabs from food-area surfaces grow for 24 hours in LPT broth, a small portion is lysed mechanically, and GENE-UP® Listeria spp. 2 (LIS 2) chemistry then looks for Listeria DNA using fluorescence resonance energy transfer, known as FRET, backed by […]

Read More

SOP: Counting Escherichia coli with Compact Dry EC Plates (MFLP-113)

October 23, 2026

Food AnalysisCompact Dry EC carries dried chromogenic medium and a cold-water-soluble gelling agent in a non-woven cloth matrix. One millilitre of diluted sample dropped at the centre diffuses on its own, the film gels within seconds, and after a day at 42°C the colonies announce themselves by colour: blue for Escherichia coli, red for other […]

Read More

SOP: Detecting Listeria monocytogenes in Foods with the 3M Molecular Detection System Version 2 (MFLP-111)

October 23, 2026

Food AnalysisLoop-mediated isothermal amplification (LAMP) drives this screen. Multiple primers recognise distinct regions of a Listeria monocytogenes gene, a strand-displacing Bst polymerase copies target continuously at one temperature, and pyrophosphate released during copying feeds a bioluminescent reaction read in real time — more than 109 copies can arise in as little as 15 minutes. Enrichment […]

Read More

SOP: Rapid Detection of Listeria monocytogenes in Dairy Products with the ANSR Test (MFLP-110)

October 23, 2026

Food AnalysisANSR compresses Listeria monocytogenes screening into one enrichment day plus under an hour of assay work. Nicking enzyme amplification nicks, repairs and displaces target DNA repeatedly at one constant temperature, and a molecular beacon reports each new product as fluorescence in real time. Speed comes with narrow discipline. Lysate must move into reaction tubes […]

Read More

SOP: Counting Staphylococcus aureus in Foods with the TEMPO STA System (MFLP-109)

October 23, 2026

Food AnalysisCoagulase-positive staphylococci matter out of proportion to their numbers, because some strains leave heat-stable toxin behind. TEMPO STA gives a count in about a day without a spread-plate series: organisms growing in a sealed multi-well card acidify the medium, a fluorescent pH indicator goes dark, and an automated reader turns a pattern of extinguished […]

Read More

SOP: Counting Yeasts and Moulds in Foods with the TEMPO YM System (MFLP-108)

October 23, 2026

Food AnalysisYeasts and moulds spoil quietly and grow slowly, so a count that finishes in days rather than a week changes how a lab can act. TEMPO YM replaces a manual most probable number series with a sealed card of miniature wells: fungi growing in those wells alter a substrate, fluorescence appears, and an automated […]

Read More

SOP: Counting Escherichia coli in Foods with the TEMPO EC System (MFLP-107)

October 23, 2026

Food AnalysisSpecificity in this count comes from a single enzyme. Escherichia coli in a filled card well acts on the medium substrate through its β-glucuronidase activity, and fluorescence appears as that reaction proceeds. Sample identity, well sizes and fluorescence pattern feed an automated most probable number calculation, giving an E. coli count in a little […]

Read More

SOP: Counting Coliforms in Foods with the TEMPO CC System (MFLP-106)

October 23, 2026

Food AnalysisColiform numbers act as a hygiene signal in many foods, and this system reads that signal by watching fluorescence disappear. Inoculated medium fills a sealed card of wells in three sizes; coliforms growing there use nutrients, push pH down, and quench a fluorescent pH indicator that shines at neutral pH. A reader then turns […]

Read More