SOP: Rapid Screening for Listeria Species in Foods and on Surfaces with the GeneQuence DNA Probe Assay (MFLP-13)

GIFSQ ID: SOP-1018

Culture confirmation for Listeria takes days, yet a plant often needs an answer sooner. GeneQuence answers at genus level with a DNA probe: enriched cells are lysed, probes bind ribosomal RNA from any Listeria species present, captured hybrids stay fixed in a microwell, and an enzyme-driven colour change reports the outcome on a plate reader, with results in roughly 30 to 48 hours overall.

Sensitivity hinges on enrichment, not probe chemistry alone: with its specified enrichment protocols, an assay can flag one Listeria cell in a 25 g food portion, so shortcuts ahead of lysis undo everything downstream.

Purpose

Purpose is rapid presumptive detection of Listeria spp. in foods and on environmental surfaces, supporting compliance work under Sections 4 and 7 of the Food and Drugs Act.

Scope

Scope covers foods and environmental samples, including swabs and sponges from stainless steel, plastic, concrete, cast iron, ceramic and painted wood. Validation supports raw meat, raw unprocessed seafood, raw frozen vegetables, cheese made from unpasteurized milk, and environmental samples. Validation data remain insufficient for heat-processed meat, heat-processed poultry, heat-processed dairy and frozen dairy. Commodities outside that list need prior validation against Compendium criteria, with data forwarded to the Microbiological Methods Committee. Qualified personnel following standard microbiological practice carry out testing, and any substituted medium must first be shown equivalent.

Equipment and Materials

  • GeneQuence Listeria kit, Neogen #6708, 93 tests: 96-well coated microtiter plate in divisible strips; pretreatment concentrate (1a) and 12 mL pretreatment buffer (1b); lysis reagent concentrate (2a) and 12 mL lysis reagent buffer (2b); 18 mL hybridization solution (3); 5 mL Listeria probe solution (4); 50 mL wash solution 20X concentrate (5); 15 mL substrate chromogen solution (6); 5 mL stop solution (7); 5 mL positive control (+) and 5 mL negative control (-)
  • Enrichment broths per MFHPB-07: PALCAM broth and UVM broth
  • Blender or homogenizer; incubators at 30°C and 35°C; water bath or heat block at 37°C; 96-well block or incubator at 45°C; small orbital platform shaker capable of 150 rpm (optional); vacuum source
  • Microtiter plate washing device with 8-wells-per-strip orientation; micropipette or repeater pipette dispensing 100 µL; 8-channel or repeater pipette dispensing 50 µL, 125 µL and 150 µL
  • Microtiter plate or strip reader at 450 nm resolving at least 0.01 absorbance unit; 500 mL or 1 L graduated cylinder; test tube rack; timer
  • Culture bottles for pre-enrichment; culture tubes for 11 mL volumes; glass test tubes 12 x 75 mm with caps; Petri plates 100 x 15 mm; sterile cotton swabs; phosphate-buffered saline (10 mM sodium phosphate, 0.85% sodium chloride, pH 7.4); absorbent paper; 10 or 25 mL disposable graduated pipettes

Procedure

  1. Handle sample units, prepare samples, and carry out pre-enrichment and enrichment exactly as MFHPB-07 directs, using PALCAM broth and UVM broth. Keep a portion of refrigerated secondary enrichment broth available afterwards, because presumptive positives are confirmed from that broth.
  2. Store kit components correctly before starting: microtiter plate, positive control, negative control and reagents 1a, 2, 3 and 5 go at 2–8°C; remaining reagents may sit at 2–25°C, and whole-kit storage at 2–8°C is acceptable. Bring refrigerated reagents to room temperature before use, without long unrefrigerated periods, and run assay steps needing room temperature at 18–30°C.
  3. Set a water bath or heater block to 37 ± 1°C. Fill a water bath to about 1.5 inches, or heater-block wells about one-third full with deionized water.
  4. Prepare pretreatment reagent by adding 12 mL pretreatment buffer (1b) into pretreatment concentrate (1a), dissolving by gentle swirling. Prepare lysis reagent the same way, adding 12 mL lysis reagent buffer (2b) into lysis reagent concentrate (2a). Both reagents may instead be combined in bottle 2a. Separate or combined, reconstituted reagents keep 60 days at −20°C; thaw at room temperature, swirl gently, and return to −20°C immediately after each use.
  5. Label one 12 x 75 mm borosilicate glass tube per sample, plus one tube each for positive and negative controls in every run. Prepare wash solution by mixing the entire wash concentrate bottle (5) with 950 mL distilled or deionized water, or 25 mL concentrate with 475 mL water for a 500 mL manual wash bottle; set up a plate washer reservoir as its manufacturer directs. Prepared wash solution keeps up to 60 days closed at room temperature.
  6. Mix a 4:1 hybridization/probe mixture from hybridization solution (3) and probe solution (4). With N equal to samples plus controls: hybridization solution volume = [(N x 0.1) + 1.6] mL and probe solution volume = [(N x 0.025) + 0.4] mL, giving 2.0 mL excess; adjust excess to suit the mixing container if needed. Place enough microwells into the plate frame without touching well bottoms, filling left to right and front to back in rows of 8, including wells for reagent blank, negative control and positive control.
  7. Gently shake sample tubes to mix, and invert control bottles several times. Pipette 0.2 mL of each control and sample into its labelled tube, using a disposable pipette or micropipette with disposable tips for every transfer; never mouth pipette.
  8. Add 0.05 mL reconstituted pretreatment reagent and 0.05 mL reconstituted lysis reagent to each tube, or 0.1 mL of combined pretreatment/lysis solution. Shake the rack by hand for 5 seconds. A correct mixture turns green; investigate any tube that does not. Incubate tubes at 37°C for 5 minutes to lyse cells enzymatically.
  9. Transfer 0.150 mL of each lysed sample, controls included, into its designated microwell. Reserve well one as reagent blank with no sample, well two for negative control, and well three for positive control.
  10. Vigorously mix hybridization/probe mixture, add 0.125 mL to every well except the reagent blank, and mix each well 5 times with the pipettor. During this 60-minute step at 45°C, detector probe labelled with horseradish peroxidase and poly dA-tailed capture probe bind target rRNA where present, while capture probe base-pairs to poly dT coating each well and anchors hybrids in place.
  11. Wash wells by one route only. With a plate-washing device, wash 5 times at room temperature, handling one 8-well strip at a time: aspirate, fill, then move to the next strip; after the final wash aspirate, invert the plate and tap it onto absorbent paper, squeezing the frame sides gently so strips stay seated. Manually, wash at least 5 times from a wash bottle: empty wells into a suitable container, tap the inverted plate on absorbent paper, fill wells completely, and shake contents out vigorously. Remove every air bubble before continuing, striking wells onto absorbent paper on a flat surface until none remain.
  12. Add 0.150 mL substrate chromogen solution (6) to each well, including the reagent blank, and incubate at room temperature for 20 minutes; bound enzyme converts substrate to a blue colour. Add 0.050 mL stop solution (7) to each well including the blank, turning colour from blue to yellow, then tap the frame side gently a few times to mix.
  13. Read absorbance at 450 nm on the plate or strip reader by manufacturer directions. Blank on the first microwell, which holds substrate chromogen plus stop solution only; never blank on air.

Recording Results

Judge controls first: negative control absorbance must be below 0.15 and positive control absorbance above 1.00, otherwise an assay is invalid and gets repeated. A sample absorbance below 0.10 indicates absence of Listeria spp. in that test portion; absorbance above 0.10 indicates presumptive presence. Record absorbance values, control outcomes and the enrichment identity for each sample alongside every result. Presumptive positives move to confirmation: plate from the refrigerated secondary enrichment broth and confirm by a cultural method, MFHPB-07 or MFHPB-30 as appropriate.

Quality Control

One positive and one negative control accompany every experimental run, and a reagent blank occupies the first well. Kit storage, reconstituted-reagent life of 60 days at −20°C and wash-solution life of 60 days closed at room temperature all form part of control. Incubator and water bath temperatures must be verified at the recommended settings; where 30°C is specified, tolerance is 30 ± 2.0°C.

Troubleshooting

  • Tubes not green after reagent addition: check that both pretreatment and lysis reagents, or the combined solution, were actually added in the right volumes before incubating.
  • Control outside its limit: treat the whole run as invalid and repeat, checking reagent storage, equilibration and reader blanking first.
  • Bubbles persisting after washing: keep striking the inverted plate on absorbent paper until wells are bubble-free; trapped bubbles distort absorbance.
  • Weak colour across all wells: verify the 60-minute, 45°C hybridization ran in full and that 4:1 mixture volumes followed the run-size formula.

Interferences and Limitations

Detection stops at genus level: a positive shows Listeria spp., never by itself which species. For environmental samples, report every Listeria species identified during confirmation, and never use a genus result to claim L. monocytogenes is absent where other Listeria were detected; conversely, where no Listeria spp. are detected at all, L. monocytogenes is also understood as not detected. Performance outside the validated commodities listed under Scope is unproven until a laboratory validates its own matrix.

Safety Notes

  • Stop solution contains 4.0 N sulfuric acid and hybridization solution contains formamide: avoid skin and mucous membrane contact with both, and consult each reagent safety data sheet.
  • Treat enrichments and lysates as potentially carrying Listeria; follow standard microbiological precautions and biohazard disposal as generic laboratory practice.
  • Never mouth pipette; use disposable tips or bulbs for all transfers.

Source Method

Adapted in original wording from Health Canada method MFLP-13, The Genequence Listeria spp. assay for the detection of Listeria spp. in foods and environmental surfaces, February 2011, Compendium of Analytical Methods, Volume 3.