SOP: Rapid Real-Time PCR Identification of E. coli O157:H7 and Verotoxin-Producing O157:NM with ADIAFOOD (MFLP-12)
GIFSQ ID: SOP-1021
Ground beef enrichments carry a heavy background flora, so a culture answer for Escherichia coli O157:H7 takes days. ADIAFOOD shortens that wait: once enrichment is finished, a real-time PCR run with molecular beacon probes flags presumptive positives within about 3 hours. Two markers work as a pair, one for the O157 identity and one that confirms the H7 side, and verotoxin-producing non-motile O157 strains are caught by the same pairing.
Speed does not change the legal weight of a result. Anything positive here stays presumptive until culture confirmation lands, especially where product compliance action is expected.
Purpose
Purpose is the rapid presumptive identification of E. coli O157:H7 strains and verotoxin-producing E. coli O157:NM strains in raw ground beef, working from isolates or enrichment broths produced by the standard O157 culture technique, by other Health Canada methodologies, or by the ADIAFOOD 8-hour enrichment route.
Scope
Scope is raw ground beef and its enrichment cultures. Non-motile O157 strains register only when they produce verotoxins; a verotoxin-negative O157:NM strain gives no confirming signal pair and is not reported by this procedure. The system carries AOAC-RI Performance Tested Method status, Certificate No. 010409, granted in 2004. Kit supply in Canada runs through AES Chemunex Canada, distributed by Innovation Diagnostics.
Equipment and Materials
- ADIAFOOD kit: extraction buffer (EX-1), lyophilized extraction reagent (EX-2), detection buffer (DT-1), lyophilized detection reagent (DT-2), detection microplates or strip tubes with pre-dispensed PCR reagents, control strip tubes (detection strip kits only), PCR optical-grade caps
- ADIAFOOD extraction kit with extraction plates, domed caps and seals; strip holders; PCR capping tool
- AES-validated real-time PCR thermocycler: 96-well (or 48-well) microplate or 96 (48) × 0.2 mL tube capacity, exciting fluorophores at a peak of 485 to 520 nm and detecting emission at a peak of 500 to 600 nm; conventional thermocycler for DNA extraction (optional)
- Centrifuge with rotor and microplate carriers; vortex equipped for microplates; two multi-channel pipettors and one single-channel pipettor; PCR enclosure (optional)
- Aerosol barrier pipettor tips, disposable multi-channel pipettor basins, sterile 2 mL screw-cap microcentrifuge tubes, powder-free gloves
- Required enrichment media, stomacher filter bags, disposable serological pipettes, denatured alcohol and bleach
Procedure
- Prepare and enrich each sample by the standard culture methodology for isolating E. coli O157:H7, by another Health Canada methodology, or by the ADIAFOOD 8-hour sample enrichment methodology following the manufacturer’s instructions. Draw off a portion of enrichment culture for PCR, and process positive and negative control wells with every sample batch.
- Reconstitute the extraction reagent: dispense EX-1 from its squeeze bottle into the EX-2 vial, recap, and mix by inversion until the lyophilized reagent dissolves completely. Pour the reconstituted EX-2 into a multi-channel pipettor basin.
- Aliquot 90 µL of reconstituted EX-2 into each well of the extraction microplate, allowing 3 wells per sample. Transfer 10 µL of cell suspension from the enrichment into the plate following the sample assignment layout.
- Seal the extraction plate wells with the domed cap strips provided, place the plate in the thermocycler, and run the DNA extraction program. That automated cycle lyses the bacterial cells, so organisms are lysed and inactivated once it finishes.
- Remove the extraction plate and centrifuge it for 5 minutes at 1,800 × g. Supernatant from this spin is the extracted DNA used for amplification.
- Reconstitute the detection reagent the same way: dispense DT-1 into the DT-2 vial, recap, and mix by inversion to full dissolution, then pour into a pipettor basin.
- Take a detection microplate or strips from the pouch and set them on the strip holder. Aliquot 15 µL of reconstituted DT-2 into each well, then transfer 10 µL of extracted DNA from the extraction plate into the detection wells.
- Seal the detection plate or strips with the optical-grade caps. Seal the extraction plate with the provided microplate seals and hold it at 4°C until analysis is complete.
- Invert the detection plate or strips vigorously 4 times to mix well contents, tap gently to clear air bubbles from well bottoms, vortex for 1 minute at maximum speed, then centrifuge for 1 minute at 1,800 × g so the full PCR mixture, DNA extract included, sits at the bottom of each well.
- Seat the detection plate or strips firmly in the real-time PCR instrument with well A1 in the upper left corner, and start the detection protocol. Primers and molecular beacon probes arrive pre-dispensed or in kit form, with specificity for E. coli O157:H7/NM already verified by the manufacturer. When the program ends, remove and discard the detection plate or strips.
Recording Results
Amplicons from the O157 and O157:H7/NM target sequences are double-stranded DNA fragments. A run reads positive when fluorescence rises above the baseline produced by the negative controls within 40 cycles of amplification; the system itself determines and sets the baseline cut-off value. A negative test normally shows no visible fluorescence. Record both marker outcomes per sample: the O157 marker plus the H7 marker together confirm E. coli O157:H7 or verotoxin-producing E. coli O157:NM. Any sample positive by this real-time PCR technique must go on to the biochemical confirmation prescribed in the standard culture method MFLP-80 or an equivalent method before a final result is issued.
Quality Control
Positive and negative control wells run with each batch, and control behaviour decides validity. Fluorescence above the baseline cut-off in a negative control invalidates the whole test; repeat the analysis with precautions taken to eliminate possible error sources. Every buffer and reagent comes from the kit, and all water, pipettes, tips and other materials touching samples or PCR reagents should be sterile and DNase-free and/or autoclaved before use, so DNase and other contamination are removed in advance. Work is performed under ISO/IEC 17025 general requirements for testing laboratory competence, as the source method directs.
Troubleshooting
- Negative control fluoresces: the run is invalid; discard the interpretation, hunt down contamination or handling error, and repeat from extracted material with fresh precautions.
- No signal from a suspect enrichment: check that 3 extraction wells per sample were loaded, that the extraction program ran to completion, and that the post-extraction spin reached 1,800 × g for the full 5 minutes.
- Bubbles or uneven wells after mixing: repeat the tap, vortex and 1-minute centrifugation steps so each reaction mixture collects fully at the well bottom before the run starts.
- Plate orientation errors: confirm well A1 sits in the upper left corner of the instrument before starting detection; a reversed plate scrambles every sample assignment.
Interferences and Limitations
Results are presumptive by design. Verotoxin-negative O157:NM strains escape detection because the marker pair only confirms non-motile strains that produce verotoxin. DNase contamination degrades target DNA, and any fluorescence in negative controls voids the batch rather than merely weakening it. Where compliance action on product is anticipated, and where stipulated, final confirmation of a presumptive positive must come from MFLP-80 or an equivalent culture method.
Safety Notes
- Treat every ground beef enrichment as potentially carrying a verotoxin-producing pathogen; use standard biohazard handling and disposal throughout.
- Wear powder-free gloves, and keep denatured alcohol and bleach, listed among the method materials, for bench decontamination away from the thermocycler and optics.
- Extracted material is lysed and inactivated by the extraction cycle, but unlysed enrichment cultures remain live and infectious until that step runs.
Source Method
Adapted in original wording from Health Canada method MFLP-12, Identification of Escherichia coli O157:H7 and Verotoxin-Producing Escherichia coli O157:NM Using the ADIAFOOD Rapid Pathogen Detection System, a Real-Time PCR Technique, March 2009, Compendium of Analytical Methods, Volume 3.