SOP: Counting Listeria Species on Environmental Surfaces with Petrifilm EL Plates (MFLP-11)
GIFSQ ID: SOP-1010
Environmental monitoring works best when a result says how much Listeria is present, not only whether any was found. Petrifilm Environmental Listeria (EL) plates put selective medium, nutrients, a cold-water-soluble gelling agent and a chromogenic indicator onto film, so a swab or sponge sample can be plated directly, incubated for about a day, and counted without preparing conventional agar.
Finding indicator organisms such as Listeria innocua carries its own message: conditions on that surface could also support Listeria monocytogenes. Colour discipline decides the count, because only colonies that reach an intense red-violet by the end of incubation qualify.
Purpose
Purpose is to enumerate viable Listeria species in environmental samples, supporting plant sanitation monitoring. Plates detect the majority of environmental Listeria, consisting of Listeria monocytogenes, Listeria innocua and Listeria welshimeri.
Scope
Scope is environmental samples collected by swab or sponge only. Never use this procedure as a screen for absence of L. monocytogenes or other Listeria species: absence requires a qualitative presence/absence method. Never use enrichment broth with the EL plate. Sample units may be analysed individually, or combined where the applicable sampling plan requirements can be met. Prove equivalency before substituting any listed medium or material with a variation, whether bought ready-made or prepared from components.
Equipment and Materials
- 3M Petrifilm EL Plates 6447/6448, stored at or below 8°C; package insert with instructions for use; Interpretation Guide, available on request
- 3M Petrifilm EL plastic spreader, catalogue #6498, designed for these plates
- Buffered peptone water (BPW) as repair broth, mandatory for the repair step
- Moistening and diluent options: Letheen Broth or Neutralizing Broth where sanitizers are present; otherwise sterile water or BPW as the moistening agent
- Sterile swabs, sponges or equivalent moistened collection devices, including 3M Quick Swab or equivalent; sterile containers
- Stomacher, blender or equivalent, or vortex for mixing; pipettes or automatic pipettes of 1.0 to 5.0 mL nominal capacity
- Incubator capable of maintaining 35°C or 37°C; standard colony counter and/or illuminated magnifier
Procedure
- Process sponge or swab samples through repair and plating immediately wherever possible. If immediate processing is impossible, hold the swab or sponge in a sterile container refrigerated at 4–8°C for a maximum of 24 hours before repair and plating; quantification remains possible within that limit.
- Have sterile diluent and repair broth ready, and disinfect the work surface. Place an EL plate on a flat surface and mark identifying sample information on the film. Have a sterile sponge or swab ready, labelled with the sample information.
- Agitate liquids until homogeneous where a liquid sample is involved, then collect the environmental sample with a swab, sponge or other moistened collection device.
- Start repair: aseptically add 2 mL of sterile BPW at 20–30°C to a swab sample, or 5 mL to a sponge sample. BPW is the repair broth here; do not substitute enrichment broth.
- Mix vigorously, stomach or vortex the collected sample with the BPW for approximately one minute.
- Leave the sample at room temperature, 20–30°C, for 1 hour up to a maximum of 1.5 hours, then mix vigorously again. This holding step repairs injured Listeria and is required, not optional.
- Lift the top film and carefully inoculate 3.0 mL of sample onto the centre of the bottom film. Roll the top film back down over the sample.
- Distribute the sample evenly by gently placing the plastic spreader on the top film over the inoculum. Do not press, twist or slide the spreader. If the inoculum self-spreads, no spreader is needed.
- Leave the plate undisturbed for a minimum of 10 minutes so the gel solidifies over the 42 cm2 circular growth area.
- Incubate plates horizontally, upright, with the clear side up, in stacks not exceeding 10 plates, for 28 ± 2 h. Follow current standards for incubation temperature, for example 35°C or 37°C, with 35 ± 1.0°C applying where 35°C is used.
- Return unused plates to the foil pouch, seal by folding and taping the open end, and store the resealed pouch in a cool dry place. Use plates within one month after opening the pouch. Exposure above 25°C and/or humidity above 50% RH can affect plate performance. Do not use plates showing orange or brown discoloration; expiry date and lot number appear on each package, and the lot number also appears on individual films.
- Read colony colour against time. If no colonies, or only red-violet colonies, are present after 28 ± 2 h, count the red-violet colonies as Listeria and finish. If colonies are present earlier but not yet intense red-violet, grey or light pink, for example, keep incubating up to 30 hours. Never exceed 30 hours, because incubation beyond the recommended time may yield ambiguous results. At the maximum 30 hours, colonies that have not turned intense red-violet, remaining grey or light pink, are not Listeria and are not counted.
- Count plates promptly after incubation. If counting at once is impossible, store plates in the freezer, avoiding that as routine practice. Do not count colonies on the foam dam, since those colonies sit outside the selective influence of the medium.
Recording Results
Count with a standard colony counter, using a magnifier-illuminator where it helps. Growth area is approximately 42 cm2. On plates carrying large numbers, estimate by counting colonies in one or more representative squares, averaging per square, and multiplying the average by 42 to give total count per plate. Where growth is heavy, plates may show many small indistinct colonies and/or a pink/brown colour throughout; record that result as too numerous to count. Three reading styles exist, quantitative, semi-quantitative and qualitative, and the worksheet should say which was used.
Converting a count to a result per sampled area needs five recorded values: area size sampled; volume of hydration fluid in the sampling device; volume of BPW added; volume plated, 3 mL per plate; and number of colonies counted. Apply: CFU / area = (Number of colonies × [volume of hydration fluid + volume of BPW] / 3 mL) / area sampled. To isolate a colony for further identification, lift the top film and pick the colony from the gel, then confirm following a cultural Listeria isolation and identification method such as MFHPB-07 or MFHPB-30 in substance: selective isolation followed by confirmatory identification of suspect colonies.
Quality Control
Check each pouch for expiry, lot number and discoloration before use, and log storage at or below 8°C for unopened plates plus the one-month limit after opening. Incubator tolerance at 35°C is ±1.0°C. As generic lab practice, run known Listeria and non-Listeria control cultures periodically on new plate lots, and record the sampled area and all volumes on every worksheet, because a missing volume makes the per-area result unrecoverable later.
Troubleshooting
- Colonies grey or light pink at first reading: continue incubation up to 30 hours; only colonies reaching intense red-violet by then count as Listeria.
- Whole plate pink/brown with tiny indistinct colonies: record as too numerous to count and, where a number is required, resample or dilute on a repeat run rather than estimating an unreadable plate.
- Plate stored warm or humid before use: expect degraded performance after exposure above 25°C or above 50% RH; discard discoloured plates and open a fresh pouch.
- Colonies clustered on the foam dam: exclude them from the count; improve spreading technique so inoculum stays inside the circular growth area.
- Low recovery suspected after sanitizer use: verify a neutralizing moistening agent, Letheen Broth or Neutralizing Broth, was used where sanitizers were present, and that BPW repair time was a full 1 to 1.5 hours.
Interferences and Limitations
Residual sanitizer on a surface can injure or kill cells before repair unless a neutralizing agent is used at collection. Skipping or shortening repair undercounts injured organisms. Colour reading has a hard endpoint: beyond 30 hours results become ambiguous, and non-red-violet colonies at 30 hours are excluded by definition. Enumeration cannot prove absence, so a zero plate never substitutes for a qualitative presence/absence test for L. monocytogenes. Performance comparisons by the University of Vermont, Silliker Laboratories and 3M found this plate approach comparable to traditional reference methods for environmental samples.
Safety Notes
- Treat environmental samples and incubated plates as potentially carrying L. monocytogenes; use gloves and biohazard disposal, and never handle plates with broken skin uncovered.
- Handle used swabs and sponges as contaminated waste immediately after plating, as generic lab practice.
- Disinfect the work surface before and after analysis, and decontaminate any spill of repair suspension promptly.
Source Method
Adapted in original wording from Health Canada method MFLP-11, Enumeration of Listeria Species in Environmental Samples using 3M Petrifilm Environmental Listeria Plates, February 2011, Compendium of Analytical Methods, Volume 3. This revision replaced MFLP-11 dated September 2006.