Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

SOP: Counting Coliforms in Foods with the TEMPO CC System (MFLP-106)

GIFSQ ID: SOP-1006

Coliform numbers act as a hygiene signal in many foods, and this system reads that signal by watching fluorescence disappear. Inoculated medium fills a sealed card of wells in three sizes; coliforms growing there use nutrients, push pH down, and quench a fluorescent pH indicator that shines at neutral pH. A reader then turns the pattern of affected wells into a most probable number style count within roughly a day.

Colour is the main caution. Strongly coloured samples, samples that develop colour during incubation, and some turbid dry mixes can mask the signal unless they are diluted far enough, as set out in the procedure.

Purpose

Purpose is to enumerate coliforms in a variety of foods, supporting compliance work under Sections 4 and 7 of the Food and Drugs Act and other relevant federal requirements.

Scope

Scope covers all foods apart from strongly coloured foods, with results in 22–27 hours. Use the TEMPO® CC test exclusively with the TEMPO® system; its vial of medium and its card are specific to this test. A laboratory substituting a different commercial or in-house medium formulation must establish equivalency itself, prepare and sterilise listed media by manufacturer directions, and carry out the work under ISO/IEC 17025 competence requirements overseen by the laboratory supervisor.

Equipment and Materials

  • TEMPO® system complete for its intended use, including TEMPO® Filler and TEMPO® Reader
  • TEMPO® CC assay kit, reference 80044, holding cards and medium vials for the analysis of 48 test samples
  • TEMPO® Filter Bags, reference 80015
  • Pipette able to deliver 0.10 mL or 1.0 mL, with disposable tips; vortex mixer; stomacher, blender or equivalent
  • Incubator able to hold 35°C
  • 0.1% peptone water; sterile deionised or distilled water
  • TEMPO® Control Kit, reference 80000

Procedure

  1. Keep units, shelf-stable foods excepted, refrigerated or frozen according to product nature before analysis. Thaw frozen units in a refrigerator, or under time and temperature conditions that prevent both microbial growth and death. Analyse as soon as practicable after receipt.
  2. Prepare primary and secondary sterile diluent ahead of time and bring them to room temperature. Clean the working surface with a suitable disinfectant.
  3. Make the analytical unit representative: agitate liquids and free-flowing materials until contents are homogeneous, and for a solid take portions from several locations within the unit.
  4. Build a 1 in 10 primary dilution in a TEMPO® filter bag by aseptically adding 25 g or 25 mL to 225 mL of 0.1% peptone water. Shake, stomach or blend according to food type. Smaller units remain acceptable when the ratio is preserved, for example 11 g in 99 mL or 10 g in 90 mL.
  5. Blend or stomach for the minimum time that produces a homogeneous suspension, never exceeding 2 min, to avoid overheating. Where food foams, run the blender slowly and draw the aliquot from beneath the liquid and foam interface.
  6. Judge colour and turbidity before dilution choices are final. A minimum dilution of 1 in 400 is recommended where the primary dilution is strongly coloured, for example fruit purées and cocoa; where colour develops during incubation through oxidation, as with raw mushrooms; or where certain dehydrated products make the dilution turbid, as with ready-to-use cake mixes.
  7. Start the clock at homogenisation: transfer into the TEMPO® card must occur within 45 minutes of homogenising the primary dilution.
  8. Set the dispenser or dispensers containing secondary diluent to the appropriate volumes and prime the pump, discarding the first two volumes dispensed. Log on to the TEMPO® preparation station.
  9. Reconstitute the TEMPO® CC medium vial by dispensing the appropriate volume of secondary diluent with the dispenser, then prepare the test dilution. For a 1 in 40 dilution, enumerating between 10 and 4.9 × 104 CFU/g, aseptically transfer 1 mL of the primary dilution into one TEMPO® CC vial containing 3.0 mL of sterile deionised or distilled water. For a 1 in 400 dilution, enumerating between 100 and 4.9 × 105 CFU/g, aseptically transfer 0.1 mL of the primary dilution into one vial containing 3.9 mL of sterile deionised or distilled water.
  10. Use the inhibitory-ingredient branch where relevant: aromatic herbs, spices, teas and herbal teas may inhibit growth, so a minimum dilution of 1 in 400 should be used for them.
  11. Extend the range by serial dilution when higher counts are expected, preparing 1 in 4,000, 1 in 40,000, 1 in 400,000 and further dilutions from the primary dilution following manufacturer instructions.
  12. Agitate each dilution to resuspend material that settled during preparation. Transfer the appropriate volume from the TEMPO® bag containing the sample into its corresponding reconstituted vial with a sterile pipette, then vortex or agitate by hand for about 5 seconds.
  13. Identify the sample through the preparation station interface. Remove one TEMPO® CC card and scan its information into the system as prompted. Scan the inoculated vial, insert the TEMPO® CC fill tube into that vial, and place the combined card and vial into a filler rack. Repeat for every prepared vial.
  14. Fill the cards with the TEMPO® Filler. In the card, inoculated medium occupies 48 wells in three sets of 16, small, medium and large, each set differing by one log in volume, and the card is hermetically sealed against contamination during later handling. After the cycle, visually check that vials are empty and discard used vials into an appropriate receptacle. Transfer filled cards from the filler rack into a TEMPO® incubation rack.
  15. Incubate cards at 35 ± 1°C for 22–27 hours.
  16. Account for software timing. TEMPO® Read manages incubation time and assumes a theoretical 15-minute interval between reading the card barcode and starting incubation. If the real interval exceeds 15 minutes without going beyond 2 hours, add that extra time to the remaining incubation time shown by the software. Always read within the time limit the software authorises.
  17. Take the incubation rack from the incubator, log on to the reading station, and place the rack of cards into the TEMPO® Reader. The reader scans each card’s barcode and interprets fluorescence in the wells: wells where coliforms grew have lost fluorescence as pH fell, and the system counts from that pattern.
  18. Remove the cards from the rack at the end of analysis and discard them into an appropriate receptacle.

Recording Results

Record results in colony forming units per gram or per millilitre of the initial sample, as the reader reports them. The system automatically associates sample identifier, test type and dilution with the enumeration, calculating the count from the number and type of positive wells by a most probable number basis. Note the dilution actually used and record where the 1 in 400 branch was triggered by colour, oxidation, turbidity or inhibitory ingredients, since those choices set the lowest count the test could report.

Quality Control

Include the TEMPO® Control Kit, reference 80000, in routine system control following manufacturer directions; beyond that control, this draft sets no invented numeric acceptance limits. Temperature discipline matters throughout growth steps: where a temperature at or below 37°C is recommended, tolerance is ± 1.0°C, exemplified by 35 ± 1°C here; higher temperatures elsewhere must be held within 0.5°C because of potential lethality to the organisms sought. Confirm dispenser priming, room-temperature diluents, disinfected surfaces and empty vials after filling as part of run checks, framed as standard laboratory quality practice.

Troubleshooting

  • Fluorescence pattern looks masked: suspect strongly coloured dilution; repeat at a minimum dilution of 1 in 400.
  • Colour appeared only after incubation: oxidation can colour products such as raw mushrooms during incubation; use the 1 in 400 branch for such matrices.
  • Dilution cloudy rather than coloured: turbid dehydrated products such as ready-to-use cake mixes also need the minimum 1 in 400 dilution.
  • Counts unexpectedly low for herbs, spices or teas: check whether the inhibitory effect branch was applied; a minimum 1 in 400 dilution should be used.
  • Result above the enumeration range: move to the next serial dilution, 1 in 4,000 and upward, instead of reporting an out-of-range estimate.
  • Vial not empty after filling: inspect fill tube placement and repeat the card preparation for that sample.

Interferences and Limitations

Strong colour excludes a food from the validated scope, and colour or turbidity arising in the primary dilution can extinguish or hide the fluorescent signal independently of coliform growth. Growth depends on coliforms assimilating nutrients and lowering pH enough to quench fluorescence within 22–27 hours; organisms that fail to do so under these conditions will not register. Inhibitory ingredients demand greater dilution, which in turn raises the lower reporting limit to 100 CFU/g at 1 in 400.

Safety Notes

  • Handle all samples and incubated cards as potentially containing pathogenic bacteria; use aseptic technique, gloves and appropriate biohazard disposal.
  • Limit blending to 2 minutes, run foaming foods at low speed, and take care with blender jars to control aerosols and splashes.
  • Discard used vials and completed cards into designated receptacles and disinfect the work area after analysis.

Source Method

Adapted in original wording from Health Canada method MFLP-106, Enumeration of coliforms in a variety of foods using the TEMPO CC (Coliform Count) Method, October 2018, Compendium of Analytical Methods, Volume 3.