SOP: Counting Escherichia coli with Compact Dry EC Plates (MFLP-113)

GIFSQ ID: SOP-1013

Compact Dry EC carries dried chromogenic medium and a cold-water-soluble gelling agent in a non-woven cloth matrix. One millilitre of diluted sample dropped at the centre diffuses on its own, the film gels within seconds, and after a day at 42°C the colonies announce themselves by colour: blue for Escherichia coli, red for other coliforms.

No spreader, no poured agar and no room-temperature storage headache are involved. What does decide accuracy is dilution discipline, especially for fresh produce, where counting from the first dilution is known to mislead.

Purpose

Purpose is to enumerate viable Escherichia coli in foods, for checking compliance with Sections 4 and 7 of the Food and Drugs Act and other relevant federal requirements.

Scope

Validated foods are raw milk cheeses, raw meat, and fresh fruit and vegetables. Never apply this procedure for detection of E. coli O157. Media chemistry rests on two substrates: Magenta-Gal, 5-bromo-6-chloro-3-indolyl-β-D-galactopyranoside, for coliforms, and X-Gluc, 5-bromo-4-chloro-3-indolyl-β-D-glucuronic acid, cyclohexylammonium salt, for E. coli, with E. coli producing blue colonies by cleaving the chromogenic substrates and other coliforms producing red colonies. Work under ISO/IEC 17025 competence requirements, and prove equivalency before substituting any medium formulation.

Equipment and Materials

  • Compact Dry EC plates, NISSUI Pharmaceutical Co., commercially available for example from Hardy Diagnostics, catalogue #54082; store at 1 to 30°C; package insert with instructions for use
  • Buffered peptone water (BPW) as initial diluent; for raw milk cheese use BPW preheated to 35°C
  • 0.1% peptone water for further dilutions
  • Stomacher, blender or equivalent; pipettes for 1 mL delivery
  • Incubator capable of maintaining 42°C ± 0.5°C; colony counter and/or magnified illuminator
  • Positive and negative control cultures, ATCC or equivalent

Procedure

  1. Hold sample units refrigerated or frozen according to product nature until analysis, except for shelf-stable foods. Thaw frozen units in a refrigerator, or under conditions that prevent both growth and death, and analyse as soon as possible after receipt.
  2. Have sterile diluent prepared and pre-warmed to room temperature or 35°C before use; for raw milk cheese, BPW must be preheated to 35°C. Clean the work surface with a suitable disinfectant. Place a Compact Dry EC plate on a flat surface and mark identifying sample information on the memorandum section.
  3. For solid samples, obtain a representative analytical unit by taking portions from several locations within the sample.
  4. Prepare dilutions for raw milk cheese and raw meat: make a 1 in 10 (1:9) dilution in BPW, stomach or blend as required for thorough mixing, and prepare additional dilutions in 0.1% peptone water if required.
  5. Prepare dilutions for fresh fruit and vegetables the same way, but plate only the 1 in 100 (1:99) dilution or higher serial dilutions for the E. coli count. An inhibitory effect has been observed at the 1 in 10 (1:9) dilution for fresh fruit and vegetable samples, so using a secondary dilution is necessary for reliable results with those matrices.
  6. Open the lid and pipette 1 mL of diluted sample directly onto the centre of the plate, letting it spread evenly across the plate without touching the matrix surface with the pipette tip.
  7. Replace the lid and leave the plate undisturbed so the inoculum diffuses and the gel forms. Return unused plates to the foil pouch and store at room temperature.
  8. Invert plates and incubate horizontally at 42°C ± 0.5°C for 24 ± 2 h. Note the tight tolerance: temperatures above 37°C must be held within 0.5°C, while growth steps at or below 37°C generally allow ±1.0°C.
  9. Count plates promptly after incubation ends.
  10. Prepare diluents where formulations are made in-house. BPW: peptone 10.0 g, sodium chloride 5.0 g, disodium phosphate 3.5 g and potassium dihydrogen phosphate 1.5 g in 1.0 L distilled water, pH adjusted to 7.2 ± 0.2, dispensed and autoclaved 15 min at 121°C. Peptone water 0.1%: peptone 1.0 g in 1.0 L distilled water, pH adjusted to 7.0 ± 0.2, dispensed and autoclaved 15 min at 121°C.

Recording Results

Count all blue colonies, using a standard colony counter and/or magnified illuminator where helpful. Blue colonies are confirmed E. coli under this method, and the final result is reported as colony forming units (CFU) of E. coli per gram of product. Where no typical E. coli colonies appear, report E. coli as less than the dilution factor per gram of product.

Growth area is 20 cm2, with a 1 cm × 1 cm grid printed on the back of the plate. On plates with more than 150 colonies, estimate by counting colonies in one or more representative grids, averaging per grid, and multiplying that average by 20 to estimate total count per plate. Calculate colonies per gram from dilution levels carrying statistically significant counts, meaning 15 to 150 colonies; if no plate falls in that range, plates with between 1 and 14 colonies can be used. When duplicate plates of consecutive dilutions are counted, use only plates within the statistically significant range to determine the average. Plates where high bacterial concentration turns the entire growth area white/pink must be repeated using higher dilutions rather than estimated.

Quality Control

Run positive and negative control cultures, ATCC or equivalent, with the work and record their colony colours. Store plates at 1 to 30°C and check packaging and expiry before opening. Incubator performance at 42°C ± 0.5°C should be logged for each run, since that tolerance is narrower than for most food microbiology incubations. As generic lab practice, verify 1 mL pipette delivery periodically and plate a diluent blank whenever a new pouch or diluent batch is opened.

Troubleshooting

  • Entire growth area white/pink: concentration is too high; repeat the sample at higher dilutions instead of trying to count the plate.
  • Produce counts inconsistent or suppressed: confirm the count came from the 1 in 100 dilution or higher, never from 1 in 10, where inhibition is documented.
  • Red colonies present, no blue: report other coliform growth as observed if needed, but the E. coli result follows the blue-colony rule and the less-than-dilution-factor wording when no blue colonies appear.
  • Inoculum pools or spreads unevenly: deliver the 1 mL slowly at the plate centre without touching the matrix, replace the lid promptly and leave the plate undisturbed until the gel forms.
  • Cheese homogenate lumpy or cold: verify BPW was preheated to 35°C for raw milk cheese before making the 1 in 10 dilution.

Interferences and Limitations

Fresh fruit and vegetable matrices inhibit recovery at 1 in 10, which is why produce counts start at 1 in 100. Heavy background growth can overwhelm the plate, turning the whole area white/pink and forcing a repeat at higher dilution. Method validation is limited to raw milk cheeses, raw meat, and fresh fruit and vegetables, and the procedure does not detect E. coli O157. Colony colour alone defines the result here, so atypical strains that do not produce the expected blue reaction would not be counted as E. coli by this plate.

Safety Notes

  • Treat raw meat, raw milk cheese and produce homogenates as potentially carrying pathogenic E. coli and other enteric organisms; use gloves, eye protection and biohazard disposal for plates.
  • Handle hot autoclaved diluents with thermal gloves, and disinfect benches before and after work as generic lab practice.
  • Decontaminate spills of diluted sample promptly and dispose of incubated plates without opening them.

Source Method

Adapted in original wording from Health Canada method MFLP-113, Enumeration of Escherichia coli Using Compact Dry EC Medium Count Plates, May 2023, Compendium of Analytical Methods, Volume 3.