Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

SOP: Detecting Listeria Species in Foods and Environmental Samples with the VIDAS LSX Assay (MFLP-77)

GIFSQ ID: SOP-1063

Speed here comes from a single enrichment broth doing double duty. Foods take a primary enrichment in LX broth and a short secondary transfer; environmental samples go straight from primary enrichment to the instrument. Inside a VIDAS® strip, everything after sample loading is automatic: capture on an antibody-coated Solid Phase Receptacle, an enzyme conjugate, washing, and a fluorescent substrate read at 450 nm.

Result scope matters. A positive signals Listeria species, not L. monocytogenes alone, so culture confirmation, on a chromogenic medium where the species question must be answered, decides what was actually present.

Purpose

Purpose is the rapid detection of Listeria monocytogenes and other Listeria spp., to determine compliance with Sections 4 and 7 of the Food and Drugs Act.

Scope

Validation covers raw meats, dairy products, fruits and vegetables, fish and seafood, environmental samples, and heat processed ready-to-eat (RTE) meat and poultry. Use on other foods requires validation first, following Compendium criteria, with data forwarded to the Microbiological Methods Committee so the application can be expanded where the data meet its requirements. Work follows ISO/IEC 17025:2005 (or latest version). A laboratory using any variation of a listed medium formulation must show equivalency and forward that data for consideration.

Equipment and Materials

  • LX broths (bags, bottles or tubes), from bioMérieux Canada, Inc.
  • VIDAS® family instrument (mini-VIDAS® or VIDAS® 30)
  • VIDAS® LSX kit (ref. 30224), containing the necessary reagents including standards and controls for the analysis of 60 test samples: sealed multi-chambered reagent strips and Solid Phase Receptacles (SPR®) pre-coated with anti-Listeria antibodies
  • VIDAS® Heat and Go, or a water bath (95–100°C), or an equivalent system
  • Stomacher and stomacher bags with filter, blender or equivalent
  • Pipette calibrated to dispense 500 µL, and disposable tips
  • Incubators capable of maintaining 30°C; sterile LX broth pre-warmed to 30 ± 2°C before use
  • Suitable disinfectant for the working area surface

Procedure

  1. Store and transport sample units refrigerated, shelf-stable products excepted, and keep frozen products frozen. Thaw frozen samples in a refrigerator, or under time and temperature conditions that prevent microbial growth or death. Analyse units as soon as possible after receipt at the laboratory.
  2. Prepare for analysis with sterile LX broth available, pre-warmed to 30 ± 2°C before use, and clean the working area surface with a suitable disinfectant. Watch incubator tolerance: a recommended 35°C may run at 35 ± 1.0°C, and lower temperatures of 30°C or 25°C may likewise be ± 1.0°C, but higher temperatures such as 43°C or 45.5°C must hold within 0.5°C because excess heat can be lethal to the organism being isolated.
  3. Take a representative analytical unit. Agitate liquids or free-flowing materials until the contents are homogeneous; for a solid, take portions from several locations within the sample unit.
  4. Start primary enrichment for foods by aseptically adding 25 g or mL of sample to 225 mL of LX broth in a stomacher bag. Blend, stomach or vortex as required for thorough mixing.
  5. Set up environmental samples at their own ratios: aseptically add 10 mL of LX broth for each swab, or 100 mL of LX broth for each sponge, or prepare a 1/10 ratio sample with LX broth for other sample types. Stomach, vortex or homogenise as required for thorough mixing. For composited samples of any kind, maintain a ratio of 1 part sample material to 9 parts LX broth.
  6. Incubate primary enrichments at 30 ± 1°C for 22–24 hours for food samples, or 24–26 hours for environmental samples.
  7. Run secondary enrichment for food samples only. After incubation, mix and transfer 3 mL of the suspension into 6 mL of LX broth, then incubate for 6–24 hours at 30 ± 1°C. Environmental samples skip this stage and proceed from primary enrichment to analysis. Keep the unheated secondary enrichment broth for foods: confirmation is done from it, not from heated material.
  8. Prepare the VIDAS® run. Remove the VIDAS® LSX kit from the refrigerator, taking out only the reagents required and allowing them to come to room temperature. Use one LSX strip and one LSX SPR® for each sample, control or standard to be tested, and reseal the storage pouch carefully after removing the SPRs® needed. Components of different lots cannot be mixed and cannot be used past the expiry date. When a new kit lot is first used, enter the factory master calibration curve data into the system using the master lot entry card included with each kit, and calibrate with the standard provided in the kit for each lot of reagents upon opening and every 14 days thereafter, following the package insert for PTC protocol data entry, master lot data entry and calibration.
  9. Homogenise the LX broth after incubation, then prepare the sample for the assay by water bath or by the VIDAS® Heat and Go device. Do not heat the standard or the controls by either route.
  10. Use the water bath route as follows: transfer 1–2 mL of LX broth into a tube and seal it. Heat for 15 ± 1 minutes at 95–100°C, cool the tube, mix the boiled broth, and transfer 0.5 mL into the sample well on the VIDAS® strip. Label the strip in the space provided with the appropriate sample identification number.
  11. Use the Heat and Go route as follows: transfer 0.5 mL of the LX broth into the sample well on the strip, label the strip, and heat for 15 ± 1 minutes following the user’s manual. Remove the strip and allow it to come to room temperature.
  12. Initiate the assay as directed in the VIDAS® operator’s manual. Insert the SPRs® and strips into the positions corresponding to the VIDAS® section indicated by the work list, and check that the colour labels with the assay code on the SPR® and the reagent strips match. From there the instrument performs every step automatically and sequentially: sample cycles in and out of the SPR®, Listeria antigens bind to the anti-Listeria antibodies inside it, unbound material is washed away, alkaline-phosphatase-conjugated antibodies cycle in and bind to the captured antigen–antibody complexes, unbound conjugate is washed away, and the fluorescent substrate 4-methyl-umbelliferyl-phosphate cycles in and out while the conjugate enzyme hydrolyses it to fluorescent 4-methyl-umbelliferone, measured at 450 nm.
  13. Read the completed assay. Once the run finishes, the computer analyses results automatically, generating a test value for each sample that is compared against internal references (thresholds) and interpreted as positive or negative. Immunoassays producing relative fluorescence values (RFV) of 0.1 indicate the presumptive presence of Listeria spp. in the test sample.
  14. Confirm presumptive positives from the unheated secondary enrichment broth, proceeding with the plating and confirmation steps of a cultural method (MFHPB-07 or MFHPB-30), as appropriate. To confirm the presence of L. monocytogenes, or to confirm its absence where other Listeria species are present, a chromogenic medium (as per MFHPB-30) that differentiates L. monocytogenes from other Listeria spp. must be used with those plating and confirmation steps.

Recording Results

Record the sample type and enrichment route taken, primary only for environmental samples, primary plus secondary for foods, together with incubation times, kit lot, calibration status, and the instrument interpretation. Report a result at the RFV criterion given in the Procedure as presumptive presence of Listeria spp., never as confirmed L. monocytogenes: species-level reporting waits on the cultural confirmation, with the chromogenic medium result recorded wherever the L. monocytogenes question was asked.

Quality Control

Kit standards and controls run as part of each assay set, unheated, with one strip and one SPR® allocated to each. Calibration with the kit standard is performed for each lot upon opening and every 14 days thereafter, after the master lot data have been entered from the card supplied with the kit. Lots are never mixed, expired components are never used, and the storage pouch is resealed immediately after SPRs® are taken. LX broth is sterile and pre-warmed to 30 ± 2°C before samples are added.

Troubleshooting

  • Assay code mismatch: stop before starting the run and recheck positions, colour labels with the assay code on each SPR® and reagent strip must match, and both must sit in the section named on the work list.
  • New lot giving no valid calibration: enter the master lot data from the card in the kit first, then calibrate with the kit standard; calibration is due on opening each lot and every 14 days after.
  • Standard or controls heated by mistake: discard that preparation, the source is explicit that standards and controls are not heated by either the water bath or the Heat and Go route.
  • Positive screen, negative plates: confirm from the unheated secondary enrichment broth, not from the boiled aliquot used in the strip, and use the chromogenic medium where L. monocytogenes itself must be resolved from other Listeria spp.

Interferences and Limitations

Detection is antigen-based and genus-level at the screening stage: other Listeria spp. respond alongside L. monocytogenes, which is why cultural confirmation decides the final report. Foods and environmental samples follow different clocks, 22–24 h primary enrichment for foods against 24–26 h for environmental samples, and only foods receive the 6–24 h secondary enrichment, so a result is only as valid as the route actually followed. Commodities outside the validated scope need validation before use.

Safety Notes

  • Treat all samples and enrichments as potentially carrying L. monocytogenes, a human pathogen; disinfect the working area surface before analysis and work aseptically throughout.
  • Take care with the 95–100°C heating step for sample aliquots, whether by water bath or Heat and Go; sealed hot tubes are handled only after cooling where the water bath route is used.
  • Dispose of used strips, SPRs®, enrichments and confirmation cultures as biohazard waste.

Source Method

Adapted in original wording from Health Canada method MFLP-77, Detection of Listeria monocytogenes and other Listeria spp. in Food Products and Environmental Samples by the VIDAS® Listeria species Xpress (LSX) Method, October 2012, Compendium of Analytical Methods, Volume 3. This revised method replaced MFLP-77 dated June 2012.