Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

SOP: Finding Micro-Leaks in Sealed Metal and Glass Containers (MFHPB-05)

GIFSQ ID: SOP-0939

A leak too small to see can still be large enough to endanger a product, because whatever lets air creep in can also carry microorganisms after processing. Micro-leak testing hunts those pathways by stressing an emptied container with vacuum or pressure and watching for the bubble stream, or dye passage, that betrays a defect.

Three routes sit side by side here. Vacuum testing is preferred, pressure testing suits the same emptied and dried container from the inside out, and dye testing pinpoints a suspect seam, scoreline or pull-tab directly. Severity can be judged from the pressure level at which leaking starts.

Purpose

Detect micro-leaks in hermetically sealed containers by applying a known vacuum or pressure, or a penetrant dye, and locate defects at the double seam, side seam, scoreline, pull-tab or can body, whether hidden or visually apparent.

Scope

Covers all two- and three-piece hermetically sealed metal cans and glass containers. In glass, testing can expose failed enamel inside a cap, gasket faults, badly formed or shallow lugs on twist-off caps, smears, dirt or foreign material on caps, and possible glass fractures. Emptied, cleaned and thoroughly dried containers are the test articles for vacuum and pressure routes; dye routes work on a cut section carrying the site under investigation.

Equipment and Materials

  • Vacuum micro-leak detector: a Plexiglas plate, 7 × 7 inches (18 × 18 cm) of 3/8 inch (9.5 mm) thick material cut to a 7-inch circle with two opposite corners removed and the remaining corners rounded, drilled with a 3/32 inch (2.38 mm) vacuum channel from edge to centre and down through the bottom face, the edge opening enlarged to ¼ inch (6.35 mm) to take ¼ inch outside-diameter plastic tubing glued in place, with rubber caps fitted at the rounded corners to prevent scratching.
  • Sealing gaskets cut from ¼ inch (6.35 mm) gum or neoprene rubber sheet, one per container size: inside diameter about ½ inch (12.7 mm) smaller than the container diameter and outside diameter about ½ inch (12.7 mm) larger; purchased O-rings of similar construction fit popular diameters.
  • Vacuum source: laboratory vacuum and pressure pump or equivalent holding a constant vacuum head of 25 ± 1 inches of mercury, calibrated yearly, or as required, against a NIST-certified calibrator. Valves and piping of ¼ inch R.P.T. with 1/8 inch (3.175 mm) nipples accepting rubber pressure tubing.
  • Light source: 100 W quartz/iodine lamp on a 1½ foot (45 cm) flexible tube, or a commercial halogen source. Bacti-Disc cutters. Round glass tank or rectangular fish tank for immersion work.
  • Pressure-test gear: can pressure test-plug assembly with butterfly screw, test-hole reamer, and a vacuum/pressure pump controlling air from 0 to 30 psi in 1 psi increments through a single control valve with an on-line gauge; for line pressures above 300 psi, a dual valve controlling 0 to 25 psi in 1 psi increments, and a pressure regulator. Transparent thick-walled water bath large enough to immerse a sealed No. 10 can completely. Soft camel-hair brushes no wider than ¼ inch (6.35 mm).
  • Cleaning and drying: warm 5% Extran 300 detergent solution or another grease- and fat-removing dishwashing detergent, soft brush, drying oven at 35°C, or forced-air oven at 60°C ± 10°C.
  • Dyes: Ardrox P134D water-washable fluorescent penetrant with optional Ardrox 9D1B developer; Magnaflux Zyglo ZL-4B liquid green fluorescent dye; optional Erythrosin B and Rhodamine B. Deaerated water, plus a small controlled amount of surfactant for bubble visibility.

Procedure

  1. Follow sealed-container safety practice throughout: treat swollen or suspect units as possible Clostridium botulinum hazards, handle contents with caution, never taste product, and sterilise suspect discarded contents before disposal.
  2. Identify each container directly on its body, record its full code, then remove and identify the label. Choose the end to open, usually the uncoded manufacturer’s end, and mark every visible defect clearly, classifying defects with the Canadian Food Inspection Agency Metal Can Defects, Identification and Classification Manual (1999). Clean adhering food, dirt and soil; scrub with detergent and water when the surface is very dirty.
  3. Open with a Bacti-Disc cutter or suitable device, cutting a hole about ¼ inch (6.35 mm) from the double seam, or at the container centre, large enough to see through, empty the contents and, for pressure testing on the same unit, fit the test plug. Examine contents at opening for off-odours, frothing, curdling or discolouration before emptying.
  4. Rinse the emptied container under running warm water to strip adhering product. Soak it in warm (40–45°C) 5% Extran 300 solution, or an equivalent grease-removing detergent, for at least 30 minutes, brushing softly to help cleaning, then rinse thoroughly under warm running tap water.
  5. Dry at 35°C overnight. Faster drying in a forced-air oven at 60°C ± 10°C for 2 hours is acceptable. Cool the dried container back to room temperature before testing.
  6. Vacuum test: add deaerated water, prepared just before use, to a depth of no more than about 1.0 inch (2.5 cm) in the container bottom. A small amount of surfactant may be added to sharpen bubble visibility; keep the amount controlled so foam does not hide a leak site.
  7. Set the Plexiglas plate with the gasket matching the container onto the open end and draw enough vacuum to seal; moistening both gasket faces improves the seal.
  8. Raise vacuum slowly to 5 inches of mercury and hold it constant for one minute before looking for bubbles.
  9. Shine the external light through the plate to light the inner surfaces. Tilt and rotate the container slowly so water progressively covers every inner surface, paying particular attention to seams, and watch for bubble formation. Mark each site where bubbles appear. A genuine leak shows as a chain of bubbles rising from one point, or as a static bubble that steadily grows; bubbles released from air trapped in seams when vacuum first lands are not leak evidence.
  10. Raise vacuum in 5-inch steps to 25 inches of mercury, repeating the full observation at each step. Match the top test level to can size and shape following manufacturer specifications.
  11. Pressure test: keep can bodies completely dry, with compound lining free of oil and water, before and during testing. Smooth the test-hole edge with the reamer held vertically, at right angles to the container end, so cut edges are not turned back.
  12. Insert the test plug until firmly engaged and tighten its butterfly screw for a proper seal. Connect the plug stem nozzle to the air supply through the control valve, or directly to a vacuum and pressure pump with a control valve.
  13. Raise internal pressure to 1–2 psi gauge, wait one minute, then immerse the container fully in a still room-temperature water bath so scoreline, double seam and pull-tab rivet all sit under pressure underwater. A little surfactant in the bath lowers surface tension and helps bubbles form at leaks.
  14. Brush adhering air bubbles off the immersed surface with a small artist’s brush. Watch for fresh bubbles or streams, mark leak locations with an indelible marker for later cause-finding such as seam defect or corrosion, and confirm a site by brushing bubbles away and seeing one reappear at the same spot. Hold each pressure level for at least one minute.
  15. Raise pressure to 5 psi and repeat the observation, then continue in 5 psi increments to a maximum of 20 psi, repeating at each stage. Respect three caps: cans not intended to hold vacuum, non-round cans and easy-open scoreline cans stop at 48 kPa (7 psi); cans of size 603 or larger stop at 10 psi; and any increment that produces peaking of the container ends the test at once.
  16. Dye test: decide which area is to be tested and cut away the top or bottom by cutting the container in half so the test site is accessible. For Ardrox P134D Type I fluorescent dye, apply dye to the site, such as a seam, pull tab or scoreline, and watch for dye appearing through it; maximum contact time is 120 minutes. Where developer is used, spray Ardrox 9D1B on the opposite side of the site and let it dry per manufacturer instructions, usually three to five minutes, before judging passage.
  17. For Magnaflux Zyglo liquid green fluorescent dye, apply dye to the site, inspect at once, then every fifteen minutes for up to two hours to decide positive or negative; a longer period may be used where judged necessary. Rhodamine B and Erythrosin B are optional alternative dyes used in the same apply-and-observe manner.

Recording Results

Note each leak’s location and the vacuum or pressure level at which it appeared, together with any defect associated with it. Record dye outcomes as positive or negative by a fixed rule: positive when dye has passed through the test area within two hours or less, negative when no dye is detected in the test area after the full two-hour period has elapsed. Tie every entry back to the container’s identification code and its marked defect map.

Quality Control

Calibrate the vacuum source yearly, or as required, with a NIST-certified calibrator, and confirm it holds 25 ± 1 inches of mercury steadily. Verify gasket fit per container size before a run, since a poor plate seal mimics or masks leaks. Reappearance of a bubble at the same marked spot after brushing is the built-in confirmation for pressure work, and the one-minute hold at each increment is the minimum observation window, not a target to shorten.

Troubleshooting

  • Bubbles appear the moment vacuum lands: trapped seam air is the likely source; keep holding and watch whether a chain or growing bubble persists from one fixed site.
  • Foam hides the interior during vacuum testing: too much surfactant was added; restart with deaerated water and a smaller, controlled addition.
  • Plate will not seal: moisten both gasket faces and check gasket size against the container diameter before raising vacuum further.
  • Bubbles everywhere on immersion: surface air is clinging to the can; brush the whole surface down and judge only bubbles that re-form at one location.
  • Container peaks during pressure steps: stop the test immediately; peaking means the pressure ceiling for that container has been reached regardless of the planned increments.
  • Dye result unclear at two hours: a longer contact period may be used where judged necessary; record the extended time with the outcome.

Interferences and Limitations

Residual product, oil or water ruins pressure testing, hence the strict cleaning and drying sequence and the dry-lining condition. Trapped air, excess surfactant foam and poor gasket seals all create false signals in vacuum work. Dye testing is site-specific: cutting the container in half means only the chosen area is judged, and a negative dye result speaks for that site within the two-hour window, not for the whole container.

Safety Notes

  • Use all dyes and developers in ventilated areas and follow manufacturer safety instructions for each product.
  • Exercise caution opening and handling contents of cans suspected of contamination, and sterilise suspect contents before disposal.
  • Respect the pressure caps by can type and size, and stop at any sign of peaking, to avoid bursting a weakened container.

Source Method

Adapted in original wording from Health Canada Health Products and Food Branch method MFHPB-05, Method for the Determination of Micro-leaks in Hermetically Sealed Metal and Glass Container, issued May 2003.