SOP: Detecting E. coli O157:H7/NM in Meats, Dairy and Produce with the BAX Real-Time PCR System (MFLP-115)

GIFSQ ID: SOP-1015

Speed matters with Shiga toxin-producing Escherichia coli O157:H7, yet enrichment still decides whether a screen succeeds. Ground beef, raw milk cheese or cut lettuce first multiplies in warm broth, and only then does a closed-tube real-time PCR look for a target fragment carried by H7 strains, including non-motile variants that a motility check would miss.

Primers, polymerase, nucleotides and a positive control already sit together as a tablet inside each PCR tube, a Scorpion™ probe lights up once built into product, and software judges signal shape and size. Analysts never open an amplified tube, so carry-over of amplified DNA is designed out.

Purpose

Purpose is presence/absence screening for E. coli O157:H7/NM in selected foods, for compliance with Sections 4 and 7 of the Food and Drugs Act and other relevant federal regulations. A screen-positive is presumptive only; cultural confirmation decides the final call.

Scope

Validation on the BAX® System Q7 covers defined foods at the 65 g and 375 g sizes named below. Raw processed meats: ground beef, meat kebab and sausage. Raw unprocessed meats: beef trim, steak cuts and beef heart. Raw frozen meats: ground beef, hamburger patty and meatballs. Raw milk and raw dairy products: raw milk, raw cream and raw Brie cheese. Raw and raw processed fruits and vegetables: cut Romaine lettuce, cut cantaloupe and baby greens salad mix. Foods outside that validated list are outside scope. Work should meet ISO/IEC 17025 competence requirements, and any change to a listed medium formulation, commercial or made in-house, needs equivalency evidence before use.

Equipment and Materials

  • BAX® System Q7 Start-Up Package (Cat. No. ASY2018): cycler/detector, workstation with BAX® software, Automated Thermal Block (Cat. No. MCH2023) or dry block heaters with thermometer inserts, capping/decapping tools, cooling block with inserts, PCR tube holders, lysis tubes with caps and rack
  • Pipettes (5-50 μL, 20-200 μL, 5-50 μL 8-channel, repeat pipettor); barrier or filter tips; powder-free nitrile gloves; BAX® System Q7 User Guide
  • BAX® System Real-Time PCR Assay for E. coli O157:H7 Exact (Cat. No. KIT2039, sufficient for 96 tests): PCR tubes with tablets, flat optical caps, 2 lysis buffer bottles (12 mL per bottle) and protease solution (400 μL per vial) for preparing working lysis reagent
  • BAX® System MP Media [MED2003 (2.5 kg) bulk powder or MED2016 StatMedia™ soluble packets] for meats and for fruits and vegetables
  • Double Strength Buffered Peptone Water (BPW) for raw milk and raw dairy products
  • Incubators or water baths able to hold prescribed temperatures and tolerances; stomacher for homogenising samples

Procedure

  1. Keep sample units refrigerated or frozen according to product nature before analysis, except for shelf-stable foods. Thaw frozen units in a refrigerator, or under time and temperature conditions that prevent both microbial growth and death. Analyse units as soon as possible after receipt.
  2. Prepare required broth volumes following manufacturer instructions. Pre-warm enrichment broth to 40-42°C for all samples except composite meat samples, which take broth at 43-45°C.
  3. Build a representative analytical unit by taking portions from several locations within a sample unit, and prepare each sample aseptically at the size, broth and ratio for its class below. Stomach as required for thorough mixing; where practical, stomach in a smaller volume of broth first, then add remaining broth to reach final volume.
  4. Individual samples of 25 to 65 g, meats and produce: combine raw meat (unprocessed, processed or frozen) or raw and raw processed fruits and vegetables with BAX® System MP media at a 1 in 10 dilution (1:9), for example 25 g sample and 225 mL pre-warmed broth. Incubate at 42 ± 0.5°C for 8-24 h.
  5. Individual samples of 25 to 65 g, dairy: combine raw milk or a raw dairy product with Double Strength BPW at a 1 in 10 dilution (1:9), for example 25 g sample and 225 mL pre-warmed broth. Incubate at 42 ± 0.5°C for 12-24 h.
  6. Composite samples of 325 to 375 g, meats and produce: combine raw meat (unprocessed, processed or frozen) or raw and raw processed fruits and vegetables with BAX® System MP media at a 1 in 5 dilution (1:4), for example 325 g sample in 1300 mL pre-warmed broth. Incubate at 42 ± 0.5°C for 8-24 h, except raw frozen meat, which incubates for 10-24 h.
  7. Composite samples of 325 to 375 g, dairy: combine raw milk or a raw dairy product with Double Strength BPW at a 1 in 5 dilution (1:4). Incubate at 42 ± 0.5°C for 12-24 h.
  8. Leave enrichments incubating while screening runs, so a full 22-24 h of incubation is completed whenever cultural confirmation becomes necessary. Remove an aliquot for BAX® testing once a sample reaches its minimum screening time, without ending incubation for the remainder.
  9. Prepare equipment in parallel. Refrigerate cooling blocks overnight, pre-heat heating blocks to 37°C and 95°C, initialise the cycler/detector following the User Guide, create a rack file, and select RUN FULL PROCESS so the instrument warms up before loading.
  10. Set out lysis tubes: one for each sample plus one blank, arranged in the rack to match the rack file. Make working lysis reagent by pipetting 150 μL of protease into one 12 mL bottle of lysis buffer, then add 200 μL of lysis reagent to each lysis tube.
  11. Transfer 20 μL of enriched sample into its corresponding lysis tube and secure caps. With a manual heating block, heat at 37°C for 20 minutes, then at 95°C for 10 minutes. With the Automated Thermal Block, run its preset parameters, which include a cooling stage. Either way, place lysis tubes in a cooling block for at least 5 minutes afterwards.
  12. Hydrate PCR tablets. Set a holder into a PCR cooling block with one PCR tube per sample. Remove and discard the lid from one strip at a time, transfer 30 μL of each lysate into its PCR tube with a multichannel pipettor, cover with a new optical cap strip and secure tightly. Repeat strip by strip.
  13. Hold hydrated PCR tubes in the cooling block for 10-30 minutes before loading; never leave them there for more than 30 minutes. Load samples, run the program and unload by following on-screen PCR Wizard prompts and the BAX® System Q7 User Guide.
  14. Make Double Strength BPW in-house where needed: peptone 10.0 g, sodium chloride (NaCl) 5.0 g, disodium phosphate 3.5 g and potassium dihydrogen phosphate 1.5 g dissolved in 500 mL distilled water, final pH 7.2 ± 0.2 at ambient temperature, dispensed into suitable glassware and autoclaved at 121°C for 15 min. Prepare BAX® System MP media strictly following manufacturer instructions.

Recording Results

PCR Wizard displays each outcome by colour and symbol. Green with a “-” sign means negative. Red with a “+” sign means positive. Yellow with a “?” sign means indeterminate, and a red slash over a “?” on a yellow background means signal error.

Report a negative as E. coli O157:H7/NM Not Detected. For an indeterminate result, repeat starting from transfer of enriched sample into a lysis tube. Treat a repeated indeterminate, or any error result, as presumptive positive. Confirm every presumptive positive from retained enrichment by immunomagnetic separation, plating and cultural confirmation, before reporting a confirmed detection. Record food class, size, broth, ratio, incubation time and temperature, each Wizard outcome, repeats, and confirmation outcomes.

Quality Control

Run a blank lysis tube in every rack, handled exactly like a sample. Tablet chemistry carries its own positive control in each PCR tube, so a run where a blank turns positive should not be reported. Growth steps at or below 37°C allow ± 1.0°C, while higher temperatures must be held within 0.5°C because excess heat can kill organisms being recovered; log the 42 ± 0.5°C enrichment for each run. As generic lab practice, verify pipette delivery for the 20 μL and 30 μL transfers periodically.

Troubleshooting

  • Indeterminate (“?”) result: repeat from the lysis transfer step with a fresh aliquot of enrichment; a second indeterminate is not a negative and must go forward as presumptive positive for confirmation.
  • Signal error symbol: treat as presumptive positive and confirm culturally; also check tube seating, cap tightness and cooling-block timing before the next run.
  • Blank positive: suspect carry-over or reagent contamination, discard affected results, decontaminate work areas and pipettes, and repeat with fresh tubes and reagent.
  • Weak or absent signals: check protease was added to lysis buffer (150 μL per 12 mL bottle), both lysis heating stages ran, and hydrated tubes were loaded within 30 minutes.
  • Broth mix-up suspected: dairy takes Double Strength BPW with longer minimum times; meats and produce take MP media.

Interferences and Limitations

Screening answers only whether target DNA amplified after enrichment; a positive does not prove a viable, confirmed isolate, which is why cultural confirmation is mandatory. Shortened enrichment risks false negatives, particularly for dairy (12 h minimum) and frozen composite meats (10 h minimum). Only listed foods and sizes are covered. Indeterminate and error outcomes can never be reported as negatives.

Safety Notes

  • Treat every enrichment as potentially containing Shiga toxin-producing E. coli O157:H7/NM; wear powder-free nitrile gloves, use aseptic technique, and dispose of enrichments, lysis tubes and PCR tubes as biohazardous waste.
  • Handle lysis tubes straight from a 95°C block with thermal protection, and allow the prescribed cooling period before handling PCR transfers.
  • Decontaminate spills of enrichment promptly, and never open a PCR tube after amplification.

Source Method

Adapted in original wording from Health Canada method MFLP-115, Detection of Escherichia coli O157:H7/NM in Select Foods Using the BAX® System Real-Time PCR Assay for E. coli O157:H7 Exact, November 2025, Compendium of Analytical Methods, Volume 3. This issue replaces MFLP-115 dated January 2024.