SOP: Rapid Detection of Listeria monocytogenes in Dairy Products with the ANSR Test (MFLP-110)
GIFSQ ID: SOP-1011
ANSR compresses Listeria monocytogenes screening into one enrichment day plus under an hour of assay work. Nicking enzyme amplification nicks, repairs and displaces target DNA repeatedly at one constant temperature, and a molecular beacon reports each new product as fluorescence in real time.
Speed comes with narrow discipline. Lysate must move into reaction tubes within a minute, sampling must come from the top of the lysate away from debris, and an invalid result has a defined repeat path rather than a guess.
Purpose
Purpose is rapid detection of Listeria monocytogenes in dairy products, for checking compliance with Sections 4 and 7 of the Food and Drugs Act and other relevant federal requirements. Enrichment takes 24–26 hours and the assay itself produces results in less than 1 hour, with amplification and detection complete within 10 minutes once started.
Scope
Scope as validated is dairy products. Other foods may seem suitable, but a commodity outside the validated application must first be properly validated against Compendium criteria, and those validation data should be forwarded to the Microbiological Methods Committee so the application can be expanded. Work under ISO/IEC 17025 competence requirements, and prove equivalency before substituting any medium formulation.
Equipment and Materials
- ANSR for Listeria monocytogenes test kit, Neogen catalogue no. 9824: lyophilized reaction tubes, 96 (12 strips of 8) in two sealed foil packs with desiccant; cluster tubes, 96; permanent caps, 96; lysis buffer, 1 bottle of 60 mL; lysis reagent, 3 lyophilized vials; kit insert
- Incubator/reader at 56 ± 2°C reading fluorescence in real time in two channels, 540/590 nm and 575/620 nm, Neogen catalogue no. 9828; computer with ANSR software (minimum Intel Core i3, 1 GB RAM, Windows 7, Ethernet and USB)
- Heater blocks for 1.2 mL cluster tubes at 80 ± 2°C and 37 ± 2°C; optional heater block for 0.2 mL tubes at 56 ± 2°C
- Pipettor 100–1000 µL with sterile tips; 8-channel pipettor 10–100 µL with sterile 100 µL filter tips; pipette pump and sterile 10 mL serological pipettes
- Vortex mixer, adjustable speed; Stomacher; thermometers; 3-channel timer; 250 mL graduated cylinder; stomacher bags for enrichment, filtered bags recommended
- LESS Plus Medium, Neogen catalogue no. 9880; phosphate-buffered saline (PBS); optional pre-pierced plate sealing film, Bio-Rad # 360-0040
Procedure
- Hold sample units refrigerated or frozen according to product nature until analysis, except for shelf-stable foods. Thaw frozen units in a refrigerator, or under conditions that prevent both growth and death, and analyse as soon as possible after receipt.
- Make a representative unit: mix liquids and free-flowing materials until homogeneous; for solids, take portions from several locations within the unit.
- Have enrichment medium prepared following manufacturer instructions and pre-warmed to 36 ± 1°C before use.
- Weigh 25 g of sample into a Stomacher-type bag. Up to five sample units may be composited together to a maximum of 125 g. Add 225 mL pre-warmed LESS Plus Medium and homogenize as appropriate for the sample type. For a sample larger than 25 g, add enough LESS broth to maintain the 1 in 10 dilution ratio.
- Incubate the enrichment at 36 ± 1°C for 24–26 h, then proceed directly to assay preparation.
- Reconstitute one vial of lyophilized lysis reagent with 18 mL lysis reagent suspension buffer, adding buffer to the reagent vial and swirling gently. Keep at 2–8°C until use. One vial covers approximately 32 samples, and prepared lysis reagent keeps at 2–8°C for up to 30 days.
- Preheat one heater block to 80 ± 2°C and a second to 37 ± 2°C; preheat the optional reagent tube block, if used, to 56 ± 2°C. Take the foil pouch of reaction tubes from the refrigerator and let it warm to room temperature for 15 min.
- Connect the ANSR reader to the computer by USB or Ethernet and switch the computer on. Switch on the reader, which preheats to 56 ± 2°C. Start the ANSR software, click connect, select the test type, and enter sample IDs, kit lot number and user information.
- Cut reaction tube strips to the number needed, keep unused tubes in the sealed foil pack, and tap tubes gently on the bench so pellets sit at the bottom. Keep the reader lid closed while an assay runs, because results are not accurate with the lid open, and always fit permanent caps, never removing them, to avoid contamination.
- Add 50 µL of enrichment culture to 1.2 mL cluster tubes using a pipettor with 100 µL filter tips. Cluster tubes may be pulled apart to the number needed, and pre-pierced sealing film may be placed over them if desired.
- Add 450 µL lysis reagent solution to each cluster tube holding sample. Return the lysis reagent solution to the refrigerator after use, within 1 h.
- Incubate cluster tubes at 37 ± 2°C for 10 min in the heater block, then move them to the 80 ± 2°C block for 20 min. That 80°C incubation may be extended to a total of 60 min to manage staggered assay start times.
- Three to five minutes before the second lysis incubation ends, preheat ANSR reagent tubes to 56 ± 2°C by placing them in the ANSR reader, or optionally in a separate heater block.
- When lysis finishes, remove and discard caps from the reaction tubes in the reader and complete transfer of sample into reaction tubes within 1 min. With an 8-channel pipettor and 100 µL filter tips, transfer 50 µL from the top one third of each lysed sample into a reaction tube. Debris collecting at the bottom of lysis tubes can interfere, so do not prime the tips and do not mix before aspirating. Fit permanent caps at once.
- Remove the tube strips from the reader or separate block, vortex briefly for about 2 seconds, and check visually that no bubbles sit at the bottom or middle of any tube; a quick tap releases bubbles. Return tubes to the reader without delay and close the lid.
- Click START in the software to begin the 10 min assay. Results display as positive, negative or invalid when the assay finishes.
- Handle an invalid result by the defined path: repeat once from the transfer step using preheated reaction tubes, or restart from adding enrichment to cluster tubes. Restart is mandatory if lysate has been at 80°C for more than 60 min. If the repeat is also invalid, or no repeat is performed, treat the sample as presumptive positive and confirm as below.
Recording Results
Software analyses fluorescent signal over time and calls each sample negative, positive or invalid using baseline, rate-of-change and other criteria; real-time curves can also be viewed. Every tube carries an internal positive control signalling in a second channel regardless of target DNA, confirming reagents worked. Record identity, composite size, enrichment time, kit lot, controls, final call, and any invalid repeat.
Confirmation is cultural, in substance as follows: from the 24–26 h LESS Plus enrichment, streak 0.1 mL onto each selective agar used for Listeria isolation and continue isolation and identification of suspect colonies. In addition, transfer 0.1 mL of the presumptive positive LESS Plus enrichment into 10 mL modified Fraser Broth and proceed with incubation and plating by the standard cultural route. Return the LESS Plus enrichment to incubation for up to 48 h and proceed culturally as required. Once confirmation is achieved, other confirmation pathways may be stopped.
Quality Control
Internal positive control in every tube is the first validity check: a target-negative tube without a control signal is not a clean negative. Verify each block and reader tolerance before a run: 37 ± 2°C, 80 ± 2°C and 56 ± 2°C. As generic lab practice, include known positive and negative process controls with each batch.
Troubleshooting
- Invalid result on first run: repeat once from the transfer step, or restart from cluster tubes; restart is mandatory once lysate has spent more than 60 min at 80°C.
- Bubbles in reaction tubes: tap tubes after the brief vortex and recheck before closing the lid, because bubbles distort fluorescence reading.
- Suspected debris carryover: aspirate only from the top one third of the lysate, without priming tips or mixing first.
- Reader gives suspect readings: confirm the lid stayed closed throughout the run and permanent caps were fitted and never removed.
- Lysis reagent aged: verify prepared reagent was kept at 2–8°C, returned to refrigeration within 1 h of use, and discarded after 30 days.
Interferences and Limitations
Debris in lysis tubes, bubbles in reaction tubes, an open reader lid and missing or removed caps each compromise accuracy. Validation covers dairy products only. A negative reflects the enriched sample tested, so enrichment discipline, 25 g in 225 mL, 36 ± 1°C, 24–26 h, decides sensitivity. Presumptive positives and unresolved invalids always require cultural confirmation.
Safety Notes
- Treat enrichments as potentially carrying L. monocytogenes; use gloves, eye protection and biohazard disposal.
- Take care around 80°C heater blocks and hot cluster tubes, and handle lysis reagents with gloves as generic lab practice.
- Never open capped reaction tubes after amplification; dispose of them sealed to contain amplified DNA.
Source Method
Adapted in original wording from Health Canada method MFLP-110, Detection of Listeria monocytogenes in dairy products using the ANSR for Listeria monocytogenes test kit, August 2020, Compendium of Analytical Methods, Volume 3. This revision replaced MFLP-110 dated October 2019.