SOP: Detecting Listeria monocytogenes in Raw Meat and on Stainless Steel with the GeneQuence DNA Hybridization Assay (MFLP-14)
GIFSQ ID: SOP-1022
Confirming Listeria monocytogenes by culture alone keeps a laboratory waiting while product sits in limbo. GeneQuence offers a faster presumptive answer: enriched cells are lysed, species-specific DNA probes capture the organism’s ribosomal RNA on a microwell plate, and a colour change read at 450 nm signals presence or absence. Sensitivity reaches as little as one CFU in a 25 g food sample when the specified enrichment protocols are followed.
Validation behind this procedure covers raw meat and stainless steel surfaces only. Other commodities may look tempting to run, but each one needs its own validation before results can stand behind it.
Purpose
Purpose is the rapid qualitative detection of Listeria monocytogenes for compliance work under Sections 4 and 7 of the Food and Drugs Act, carried out by personnel with appropriate laboratory training in microbiology. Positive results are presumptive and must be confirmed with a cultural method.
Scope
Scope is validated for raw meat and stainless steel surface samples. Sample handling, preparation, pre-enrichment and enrichment all follow the companion culture procedure MFHPB-07, which uses PALCAM broth and UVM 2 as its enrichment broths; the secondary enrichment broth from that procedure is retained, since confirmation plating starts from it. Applying the assay to foods outside the validated list requires prior validation against the criteria of the Compendium of Analytical Methods, and those validation data are to be forwarded to the Microbiological Methods Committee so the application can be expanded.
Equipment and Materials
- GeneQuence kit (No. 6708, 93 tests, Neogen Corp.): one 96-well microtiter plate in divisible strips, coated; pretreatment concentrate (1a) and 12 mL pretreatment buffer (1b); lysis reagent concentrate (2a) and 12 mL lysis reagent buffer (2b); 18 mL hybridization solution (3); 5 mL L. monocytogenes probe solution (4); 50 mL wash solution 20X concentrate (5); 15 mL substrate-chromogen solution (6); 5 mL stop solution (7); 5 mL positive control and 5 mL negative control
- Kit storage: microtiter plate, both controls, and reagents 1a, 2, 3 and 5 at 2–8°C; other reagents may be held at 2–25°C, and the whole kit may be stored at 2–8°C. Reconstituted reagent 1a keeps at −20°C and stays stable for 60 days in that form
- Enrichment broths: PALCAM broth and UVM 2
- Blender or homogenizer; incubators at 30°C and 35°C; water bath or heat block at 37°C; 96-well block or incubator at 45°C; small orbital platform shaker capable of 150 rpm (optional)
- Vacuum source; microtiter plate washing device with 8-well-per-strip orientation; micropipette or repeater pipette for 100 µL; 8-channel pipette (recommended) or repeater pipette for 50 µL, 125 µL and 150 µL volumes
- Microtiter plate or strip reader at 450 nm resolving at least 0.01 absorbance unit; 500 mL or 1 L graduated cylinder; test tube rack; timer
- Culture bottles for pre-enrichment, culture tubes for 11 mL sample volume, glass test tubes 12 × 75 mm with caps, Petri plates 100 × 15 mm, sterile cotton swabs, phosphate-buffered saline (10 mM sodium phosphate, 0.85% sodium chloride, pH 7.4), absorbent paper, 10 or 25 mL disposable graduated pipettes
Procedure
- Handle sample units, prepare for analysis, and prepare samples exactly as the MFHPB-07 culture procedure directs, then run its pre-enrichment and selective enrichment in PALCAM broth and UVM 2. Keep the secondary enrichment broth for the confirmation step below.
- Bring refrigerated reagents to room temperature before use, without leaving them unrefrigerated for long periods. Room-temperature steps run at 18–30°C. Set the water bath or heater block to 37 ± 1°C; fill a water bath to about 1.5 inches, or fill heater block wells about one-third with deionized water.
- Prepare pretreatment reagent by adding the 12 mL of pretreatment buffer (bottle 1b) directly into the pretreatment concentrate (bottle 1a) and swirling gently to dissolve. Prepare lysis reagent the same way, adding the 12 mL of lysis reagent buffer (bottle 2b) into the lysis reagent concentrate (bottle 2a). Both reagents may instead be combined in bottle 2a; separate or combined, reconstituted reagents stay stable 60 days at −20°C, are thawed at room temperature, swirled gently, and returned to −20°C immediately after use.
- Label one 12 × 75 mm borosilicate glass tube per sample and place the tubes in a rack, adding one tube for a positive control and one for a negative control in every run.
- Prepare wash solution by mixing the entire contents of the wash concentrate bottle (bottle 5) with 950 mL of distilled or deionized water; for manual washing with a 500 mL wash bottle, mix 25 mL of concentrate with 475 mL of water. Fill the plate washer reservoir. Prepared wash solution keeps in a closed bottle at room temperature for up to 60 days.
- Make a 4:1 hybridization/probe mixture from hybridization solution (bottle 3) and probe solution (bottle 4) in a plastic container: volume of bottle 3 = [(N × 0.1) + 1.6] mL and volume of bottle 4 = [(N × 0.025) + 0.4] mL, where N is the number of test samples plus controls. This formula builds in 2.0 mL of excess.
- Load the needed microwells into the plate frame from left to right and front to back in rows of 8, without touching well bottoms, reserving wells for the reagent blank, negative control and positive control.
- Mix test samples by gently shaking the tubes; invert the control bottles several times. Add 0.2 mL of each control and test sample to its labelled tube.
- Add 0.05 mL of reconstituted pretreatment reagent and 0.05 mL of reconstituted lysis reagent to each tube, or 0.1 mL of the combined pretreatment/lysis solution. Shake the rack by hand for 5 seconds; a correct mixture turns green, and any tube that is not green needs its reagent addition checked. Incubate the rack at 37°C for 5 minutes.
- Take the tubes off the heat and transfer 0.150 mL of each lysed sample, controls included, to its designated microwell. Well one is the reagent blank and receives no sample; well two takes the negative control and well three the positive control.
- Mix the hybridization/probe solution vigorously, add 0.125 mL to each microwell, and mix each well 5 times with the pipettor. Add none to the reagent blank well. Incubate the plate at 45°C for 60 minutes.
- Wash the wells. With a plate-washing device, wash 5 times at room temperature, one 8-well strip at a time: aspirate, fill, move to the next strip; after the last wash aspirate, invert the plate and tap it onto absorbent paper, holding strips in place by gently squeezing the frame sides. Manually, wash at least 5 times with a wash bottle: empty the wells, tap the inverted plate on absorbent paper, fill wells completely, and shake out vigorously. Every air bubble must be gone before continuing; strike the plate on absorbent paper on a flat surface until bubbles clear.
- Add 0.150 mL of substrate-chromogen solution (bottle 6) to each microwell, including the reagent blank, and incubate at room temperature for 20 minutes. Bound horseradish peroxidase turns the substrate blue during this step.
- Add 0.050 mL of stop solution (bottle 7) to each microwell, blank included; the colour shifts from blue to yellow. Tap the frame side gently a few times to mix.
- Read absorbance at 450 nm on the plate or strip reader following the manufacturer’s instructions, blanking on the first microwell, which holds substrate-chromogen plus stop solution only. Never blank with air.
Recording Results
Controls gate every reading. A negative control absorbance of 0.15 or higher invalidates the assay, and a positive control absorbance of 1.00 or lower does the same; either failure means the run is repeated. For samples, absorbance below 0.10 indicates absence of L. monocytogenes in the test sample, while absorbance above 0.10 indicates its presumptive presence. Record each well’s absorbance with its control values. Confirm every presumptive positive by taking the secondary enrichment broth through the plating and confirmation steps of a cultural method, MFHPB-07 or MFHPB-30.
Quality Control
Each run carries one positive and one negative control, and both must meet the absorbance limits above before any sample is interpreted. Media variations, whether commercial equivalents or made from scratch, are the laboratory’s responsibility to prove equivalent. Incubator and water bath temperatures must actually hold the recommended values; where 30°C is specified, an incubator may run at 30 ± 2.0°C. Reagent age matters as well: reconstituted pretreatment and lysis reagents expire after 60 days frozen, and wash solution after 60 days at room temperature.
Troubleshooting
- Tubes not green after reagent addition: a reagent was missed or under-dispensed; check additions before the 37°C lysis step rather than after reading.
- Positive control at or below 1.00: the run is invalid; suspect aged reconstituted reagents, a hybridization mixture made off-ratio, or a plate held unrefrigerated too long.
- Negative control at or above 0.15: suspect carry-over or inadequate washing; verify all 5 washes happened and that every bubble was cleared before substrate went in.
- Weak colour across the plate: confirm the hybridization incubation held 45°C for the full 60 minutes and that probe mixture volumes followed the N-based formula.
Interferences and Limitations
Approval extends only to raw meat and stainless steel surfaces; results on other commodities carry no standing until that food is validated. Air bubbles left in wells distort both washing and absorbance. A probe result, however clean, remains presumptive: only culture confirmation closes a positive. Because the target is ribosomal RNA captured after enrichment, a sample enriched by any route other than the specified protocols loses the one-CFU-in-25 g sensitivity claim.
Safety Notes
- Stop solution contains 4.0 N sulfuric acid and hybridization solution contains formamide; avoid contact with skin and mucous membranes, and consult the safety data sheet for handling detail.
- Treat all enrichments as potentially carrying L. monocytogenes, a pathogen of particular concern for pregnant and immunocompromised staff; use standard biohazard disposal.
- Handle the microtiter plate washer’s aspirated waste as contaminated liquid and decontaminate it before disposal.
Source Method
Adapted in original wording from Health Canada method MFLP-14, The Genequence Listeria monocytogenes assay for the detection of Listeria monocytogenes in raw meat and stainless steel surfaces, October 2013, Compendium of Analytical Methods, Volume 3.