SOP: Rapid Screening for Listeria Species in Foods and on Surfaces with the GeneQuence DNA Probe Assay (MFLP-13)
Culture confirmation for Listeria takes days, yet a plant often needs an answer sooner. GeneQuence answers at genus level with a DNA probe: enriched cells are lysed, probes bind ribosomal RNA from any Listeria species present, captured hybrids stay fixed in a microwell, and an enzyme-driven colour change reports the outcome on a plate reader, […]
SOP: Identifying Yersinia enterocolitica Colonies by Real-Time PCR (MFLP-118)
Confirmation need not wait for biochemical panels. A presumptive colony from a validated agar can be named within 2 hours by multiplex real-time PCR hunting two Yersinia enterocolitica targets: outL, coding for outer membrane protein L, a species marker, and ail, the attachment and invasion locus, a second species marker and major virulence marker. Fluorogenic […]
SOP: Detecting E. coli O157 (Including H7) in Raw Meats with the Neogen Molecular Detection System (MFLP-116)
Isothermal chemistry changes the shape of a pathogen screen. Loop-mediated isothermal amplification (LAMP) holds one temperature while multiple primers and a strand-displacing Bst polymerase copy target DNA continuously, past 109 copies in as little as 15 minutes. Pyrophosphate released during copying feeds a two-step light reaction, so the instrument watches bioluminescence rise in real time. […]
SOP: Detecting E. coli O157:H7/NM in Meats, Dairy and Produce with the BAX Real-Time PCR System (MFLP-115)
Speed matters with Shiga toxin-producing Escherichia coli O157:H7, yet enrichment still decides whether a screen succeeds. Ground beef, raw milk cheese or cut lettuce first multiplies in warm broth, and only then does a closed-tube real-time PCR look for a target fragment carried by H7 strains, including non-motile variants that a motility check would miss. […]
SOP: Rapid PCR Screening for Listeria Species on Environmental Surfaces (MFLP-112)
Speed comes from pairing one enrichment day with a real-time PCR read. Sponges and swabs from food-area surfaces grow for 24 hours in LPT broth, a small portion is lysed mechanically, and GENE-UP® Listeria spp. 2 (LIS 2) chemistry then looks for Listeria DNA using fluorescence resonance energy transfer, known as FRET, backed by a […]
SOP: Counting Escherichia coli with Compact Dry EC Plates (MFLP-113)
Compact Dry EC carries dried chromogenic medium and a cold-water-soluble gelling agent in a non-woven cloth matrix. One millilitre of diluted sample dropped at the centre diffuses on its own, the film gels within seconds, and after a day at 42°C the colonies announce themselves by colour: blue for Escherichia coli, red for other coliforms. […]
SOP: Detecting Listeria monocytogenes in Foods with the 3M Molecular Detection System Version 2 (MFLP-111)
Loop-mediated isothermal amplification (LAMP) drives this screen. Multiple primers recognise distinct regions of a Listeria monocytogenes gene, a strand-displacing Bst polymerase copies target continuously at one temperature, and pyrophosphate released during copying feeds a bioluminescent reaction read in real time — more than 109 copies can arise in as little as 15 minutes. Enrichment sets […]
SOP: Rapid Detection of Listeria monocytogenes in Dairy Products with the ANSR Test (MFLP-110)
ANSR compresses Listeria monocytogenes screening into one enrichment day plus under an hour of assay work. Nicking enzyme amplification nicks, repairs and displaces target DNA repeatedly at one constant temperature, and a molecular beacon reports each new product as fluorescence in real time. Speed comes with narrow discipline. Lysate must move into reaction tubes within […]
SOP: Counting Listeria Species on Environmental Surfaces with Petrifilm EL Plates (MFLP-11)
Environmental monitoring works best when a result says how much Listeria is present, not only whether any was found. Petrifilm Environmental Listeria (EL) plates put selective medium, nutrients, a cold-water-soluble gelling agent and a chromogenic indicator onto film, so a swab or sponge sample can be plated directly, incubated for about a day, and counted […]
SOP: Counting Staphylococcus aureus in Foods with the TEMPO STA System (MFLP-109)
Coagulase-positive staphylococci matter out of proportion to their numbers, because some strains leave heat-stable toxin behind. TEMPO STA gives a count in about a day without a spread-plate series: organisms growing in a sealed multi-well card acidify the medium, a fluorescent pH indicator goes dark, and an automated reader turns a pattern of extinguished wells […]
SOP: Counting Yeasts and Moulds in Foods with the TEMPO YM System (MFLP-108)
Yeasts and moulds spoil quietly and grow slowly, so a count that finishes in days rather than a week changes how a lab can act. TEMPO YM replaces a manual most probable number series with a sealed card of miniature wells: fungi growing in those wells alter a substrate, fluorescence appears, and an automated reader […]
SOP: Counting Escherichia coli in Foods with the TEMPO EC System (MFLP-107)
Specificity in this count comes from a single enzyme. Escherichia coli in a filled card well acts on the medium substrate through its β-glucuronidase activity, and fluorescence appears as that reaction proceeds. Sample identity, well sizes and fluorescence pattern feed an automated most probable number calculation, giving an E. coli count in a little over […]
SOP: Counting Coliforms in Foods with the TEMPO CC System (MFLP-106)
Coliform numbers act as a hygiene signal in many foods, and this system reads that signal by watching fluorescence disappear. Inoculated medium fills a sealed card of wells in three sizes; coliforms growing there use nutrients, push pH down, and quench a fluorescent pH indicator that shines at neutral pH. A reader then turns the […]
SOP: Counting Viable Aerobic Mesophilic Bacteria in Foods with the TEMPO AC System (MFLP-105)
Aerobic count gives a broad picture of viable mesophilic load, and this automated route compresses that picture into about a day. Sample suspension goes into a reconstituted medium vial, a filler distributes it across a sealed card of tiny wells, and a reader scores fluorescence after incubation. Because well volumes span three sizes, pattern of […]
SOP: Detecting Listeria on Environmental Surfaces with the RapidChek Listeria NextDay System (MFLP-104)
A lateral-flow strip can give an environmental Listeria answer without an instrument. Enrichment in RapidChek Listeria NextDay medium grows viable Listeria species from a sponge overnight and a little beyond, a brief boil releases the sample for testing, and a double-antibody sandwich strip traps the organisms between an immobilised capture antibody and a gold-labelled second […]
SOP: Identifying Vibrio parahaemolyticus Colonies by Real-Time PCR (MFLP-102)
Confirming a presumptive Vibrio parahaemolyticus colony by biochemistry takes a battery of tests. A multiplex real-time PCR collapses that work into about 2 hours by asking three genetic questions at once: is the species marker tlh present, and are either of the virulence-associated hemolysin genes, tdh or trh, carried alongside it? Fluorogenic probes report each […]
SOP: Detecting Listeria on Environmental Surfaces with the 3M Molecular Detection System (MFLP-101)
Environmental monitoring lives or dies on turnaround. A molecular screen after a single enrichment day flags a Listeria harborage while corrective cleaning can still matter, whereas culture alone can take days. Loop-mediated isothermal amplification (LAMP) supplies that speed: target DNA copies itself continuously at one temperature, and a bioluminescent signal reports the copying in real […]
SOP: Detecting Salmonella in Foods with the 3M Molecular Detection System (MFLP-100)
Molecular screening shortens the wait for a Salmonella answer without abandoning culture. Enrichment grows viable cells first, loop-mediated isothermal amplification (LAMP) then copies a target sequence at a single temperature, and a bioluminescent readout reports that copying as it happens. Presumptive positives appear in real time, negatives only at the end of the run, and […]
SOP: Counting Total Aerobic Bacteria with Compact Dry TC Plates (MFLP-10)
Dry-sheet plates offer a compact alternative to poured agar for routine aerobic counts. A measured volume spreads itself across a dehydrated sheet, turns that sheet to gel in seconds, and grows colonies coloured red by a tetrazolium redox indicator, so counting stays straightforward even in a small laboratory. Ease of handling is the main attraction, […]
SOP: Counting Enterobacteriaceae on 3M Petrifilm EB Plates (MFLP-09)
Enterobacteriaceae counts tell a plant how well hygiene is holding, because the family bundles coliforms together with genuine pathogens such as Salmonella, Shigella and Yersinia in a single hygiene picture. Film plates remove media preparation entirely: nutrients, selective agents, a cold-water-soluble gelling agent and an indicator arrive coated on the plate, ready for a 1 […]
SOP: Detecting Listeria Species in Foods and on Surfaces with the Assurance GDS System (MFLP-08)
Sometimes genus-level knowledge is exactly what a plant needs. A Listeria species hit on a drain or in a dairy product signals conditions that could also shelter L. monocytogenes, long before species identification catches up. Enrichment, magnetic concentration and automated genetic detection deliver that early warning here, with cultural confirmation available whenever a positive needs […]
SOP: Detecting Listeria monocytogenes with the Assurance GDS Genetic System (MFLP-07)
Genetic screening shortens the wait for Listeria monocytogenes answers without giving up enrichment. A single food-specific enrichment grows the target first, magnetic concentration then pulls it away from competing flora and food debris, and a sealed-tube amplification reads fluorescence automatically. Speed comes from the instrument; reliability still comes from choosing the right broth and clock […]
SOP: Detecting E. coli O157:H7 in Raw Beef with the Atlas EG2 Assay (MFLP-03)
Raw beef carries a zero-tolerance problem, and enrichment plus molecular screening answers it faster than culture alone. Enriched broth feeds a fully automated instrument that captures target messenger RNA, amplifies it isothermally and reads a light signal, so a walk-away run screens many samples while the analyst keeps the matching enrichments warm for culture confirmation […]
SOP: Isolating Listeria monocytogenes from Foods by Two-Stage Enrichment (MFLP-01)
Finding a handful of Listeria monocytogenes cells in a ready-to-eat food takes patience rather than speed. Growth starts in a first enrichment that favours Listeria, a second selective broth then tightens the field, and plating happens from both stages so slow or outnumbered cells still get a chance to form colonies. Identity rests on a […]