Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

← All subjects

Unit 7: Evaporation

GIFSQ ID: FTN-0119

Unit 7 of 12 in Unit Operations. This page is one unit of the Unit Operations notes.

All units in Unit Operations:

Previous unit: Unit 6: Drying and Dehydration | Next unit: Unit 8: Distillation

Unit 7: Evaporation

Note

A pot of tomato juice left simmering on the stove thickens as the water boils away. The juice that started thin and watery ends up as a rich paste, and the steam that leaves carries nothing but water: the solids, the colour and the flavour stay behind. Scale that pot up to a factory, put it under vacuum so it boils gently at 60°C instead of fiercely at 100°C, feed it continuously, and you have an evaporator, the machine that turns milk into concentrated milk, juice into concentrate, and sugar liquor into syrup before it ever sees a crystallizer. This unit follows the water out of a liquid, and counts the steam it costs.

Questions to think about

  • Why evaporate a liquid instead of drying it to a powder straight away?
  • What is evaporation economy, and why does one kilogram of steam never evaporate exactly one kilogram of water?
  • Why does a sugar solution boil above 100°C, and how do you find its boiling point?
  • How do you get three kilograms of evaporation from one kilogram of steam?
  • Why do evaporators run under vacuum, and what does that do to flavour?
  • Which evaporator do you choose for a thin juice, a thick paste, or a heat sensitive flavour?

7.1 Why evaporate

Evaporation is the removal of water from a liquid by boiling it away. It sits between the liquid and the solid: a juice is evaporated to a concentrate, and only then, if a powder is wanted, is the concentrate spray dried. Evaporating first is cheaper than drying the dilute liquid directly, because boiling water out of a liquid takes less energy per kilogram than drying it out of a solid, and because an evaporator can reuse its own heat in ways a dryer cannot.

The books treat evaporation as a heat transfer operation with a mass balance attached. The liquid to be concentrated is fed in, heat is supplied, usually as condensing steam, water boils off as vapour, and the concentrated liquid leaves. The vapour is either condensed and thrown away, or reused. The whole design turns on three questions: how much water must be removed, how much heat that takes, and how much steam must be bought to supply it.

The measure of performance is the economy, E, defined as the ratio of the mass of water evaporated to the mass of steam used:

E = V/wᵥ (18.1)

where V is the water evaporated and wᵥ is the steam consumed. An economy of 1 means one kilogram of steam evaporates one kilogram of water. A single effect evaporator working well gets close to 1, and a multiple effect evaporator gets well above it, as section 7.5 shows.

Quick check

A single effect evaporator uses 195 kg of steam per hour to evaporate 167 kg of water per hour. What is its economy?

Check your answer

Economy = 167/195 = 0.86 kg water per kg steam. That is the figure from Worked example 7.1 below.

7.2 A single effect evaporator: the balances

Ibarz draws the simplest evaporator as a box with a heating coil inside it, and every quantity that matters is labelled on the drawing.

Figure 7.1: Simple evaporator

Figure 7.1: A simple evaporator. The vessel holds liquid at pressure P and temperature t. Heating steam w₝ enters at the top with temperature T and enthalpy Ĥ₝ and leaves as condensate at the bottom with enthalpy ĥ₝. Feed wₚ enters at temperature tₚ with enthalpy ĥₚ. Vapour leaves at the top at temperature t with enthalpy Ĥₛ, and concentrate wₕ leaves at the bottom at temperature tₕ with enthalpy ĥₕ. Q̇ is the heat supplied. (Ibarz, Fig. 18.2, p. 626)

The balances are written for a steady state, with the mass that enters equal to the mass that leaves, and the heat that enters equal to the heat that leaves. The total mass balance is wₐ = wᵥ + wᴄ (18.2), where wₐ is the feed, wᵥ the vapour and wᴄ the concentrate. The solids balance is wₐxₐ = wᴄxᴄ (18.3), because the solids do not evaporate: all the solids that enter leave in the concentrate. The energy balance is wₐĥₐ + wᵥĤᴡ = wᵥĤᵥ + wᴄĥᴄ (18.4), with Ĥ the vapour enthalpies and ĥ the liquid enthalpies, and the heat supplied by the steam Q̇ = wᵥ(Ĥᴡ - ĥᴡ) (18.5).

Brennan draws the same evaporator with the flows a plant operator would measure: steam in, condensate out, feed in, vapour out, product out, with the solids fractions marked on the feed and the product.

Figure 7.2: Evaporator mass balance diagram

Figure 7.2: Mass balance diagram for an evaporator. Steam Vᵢ lb/hr enters through the coil and leaves as condensate through the trap at the bottom left. Vapour Vₚ lb/hr leaves at the top right. Liquid feed Lᵢ lb/hr with solids fraction Xf enters at the right, and product liquor Lₚ lb/hr with solids fraction Xp leaves at the bottom. The heat transferred is Q = UAΔT (11.1). (Brennan, Fig. 11.2, p. 221)

The heat transfer itself is Q = UAΔT (11.1), where U is the overall heat transfer coefficient, A the heating surface area, and ΔT the temperature difference between the condensing steam and the boiling liquid. That one equation sizes the evaporator: once the heat duty is known from the balances, and ΔT is known from the steam pressure and the boiling point, the area follows.

Worked example 7.1: a single effect evaporator (Earle Example 8.1)

A solution of 10% solids is concentrated to 30% solids at 250 kg h⁻¹ in an evaporator working at 77 kPa absolute, with steam at 200 kPa gauge, U = 1,700 J m⁻² s⁻¹ °C⁻¹, feed at 18°C, boiling point 91°C, specific heat 4.186 x 10³ J kg⁻¹, steam latent heat 2,164 kJ kg⁻¹ at 134°C, and latent heat at 77 kPa 2,281 kJ kg⁻¹.

Mass balance, per hour: feed 250 kg, of which 25 kg is solids and 225 kg is liquid. Product is 25/0.30 = 83 kg, of which 25 kg is solids and 58 kg is liquid. Evaporation is 250 - 83 = 167 kg h⁻¹.

Heat balance: the heat per kg of steam is the latent heat plus the sensible heat of the condensate cooling, 2.34 x 10⁶ J. The heat required is 4.57 x 10⁸ J, so the steam needed is 4.57 x 10⁸/2.34 x 10⁶ = 195 kg h⁻¹. That is 195/167 = 1.17 kg of steam per kg of water evaporated, an economy of 0.86.

The area follows from Q = UAΔT. The steam condenses at 134°C and the liquid boils at 91°C, so ΔT = 43°C, and the area is 1.74 m². A small evaporator, but the method is the whole design in miniature: mass balance, heat balance, then area.

Practical note: the economy of a single effect evaporator is always below 1 in practice, because some heat warms the feed and some is lost. An economy of 0.86 is a good single effect result. The way past 1 is to reuse the vapour, which is what multiple effect evaporation does.

7.3 Boiling point rise and the Dühring diagram

Pure water boils at 100°C at atmospheric pressure. A solution of solids in water boils higher, and the rise grows as the solution gets more concentrated. This boiling point rise matters twice over: it shrinks the temperature difference ΔT that drives the heat transfer, so the evaporator needs more area, and it sets the temperature the product actually sees, which matters for quality.

The books give two ways to find the boiling point of a solution. For dilute solutions, Raoult's law gives the boiling point rise as ΔT_b = (R T_b²/λ)(x_solute) in the form of Eq. 18.13, where the rise is proportional to the mole fraction of solute. For concentrated food solutions, the Dühring diagram is the working tool: it plots the boiling temperature of the solution against the boiling temperature of pure water at the same pressure, with one straight line for each concentration. Read the boiling point of water at the working pressure from the steam tables, go up to the line for your concentration, and read across to the boiling point of the solution.

Ibarz gives the Dühring diagram for sucrose solutions, with lines for 200, 600, 700, 800 and 1,000 g of sucrose per 100 g of water. The labels are reproduced here in the order the book prints them at the right hand end of the lines: 1,000 at the top, then 800, then 600, then 700, then 200 at the bottom. The 600 line sits above the 700 line in the printed diagram, and that order is kept here exactly as printed.

Figure 7.3: Dühring diagram for sucrose solutions

Figure 7.3: Dühring diagram for sucrose solutions. Boiling temperature of the solution against boiling temperature of pure water at the same pressure, with one line for each concentration in g sucrose per 100 g water. The labels are in the order printed in the book at the right hand end of the lines: 1000, 800, 600, 700, 200 from top to bottom. The curve paths are traced from the printed figure, so the positions are approximate while the axes, gridlines and labels are the book's. (Ibarz, Fig. 18.4, p. 631)

The book fits the sucrose lines with the correlation of Crapiste and Lozano, giving the constants in Table 7.1. With those constants, the boiling point rise and the latent heat of the solution can be calculated for sucrose, reducing sugars and juices without reading the chart.

Table 7.1: Constants for boiling point rise and latent heat of solutions (Ibarz Table 18.1)

Solutionα x 10²βδγ x 10²
Sucrose3.0610.0940.1365.328
Reducing sugars2.2270.5880.1193.593
Juices1.3600.7490.1063.390

Table 7.1: Constants for the boiling point rise and latent heat correlations. Source: Crapiste, G. H. and Lozano, J. E., Journal of Food Science 53(3), 865-868, 1988, as cited in Ibarz, Table 18.1, p. 645.

Earle gives the same diagram for salt solutions, and it shows how large the rise can be. A saturated sodium chloride solution boils at 109°C at atmospheric pressure, nine degrees above pure water. Under vacuum the gap stays: at 25.4 kPa, water boils at 65.6°C and saturated salt solution at 73.3°C; at 33.3 kPa, water boils at 71.7°C and the saturated salt solution at 79.4°C.

Figure 7.4: Dühring plot for sodium chloride solutions

Figure 7.4: Dühring plot for sodium chloride solutions. Boiling point of the solution in °F against boiling point of water in °F at the same pressure, with lines for saturated, 25%, 20%, 10%, 5% and 0% salt. The 0% line is the diagonal, where solution and water boil at the same temperature. The curve paths are traced from the printed figure, so the positions are approximate while the axes, gridlines and labels are the book's. (Earle, Fig. 8.3, p. 112)

Worked example 7.2: boiling point rise of a salt solution (Earle Example 8.5)

Using the Dühring plot above, a saturated sodium chloride solution boils at 109°C at atmospheric pressure. At 25.4 kPa, water boils at 65.6°C and the saturated salt solution at 73.3°C. At 33.3 kPa, water boils at 71.7°C and the saturated salt solution at 79.4°C. The rise is about 7.7°C in both vacuum cases, and it does not vanish under vacuum: the boiling point falls, but the gap between solution and water stays.

Quick check

A juice concentrate boils at 95°C when the water at the same pressure boils at 88°C. What is the boiling point rise, and what does it do to the heat transfer?

Check your answer

The rise is 7°C. It shrinks the temperature difference between the steam and the boiling liquid by 7°C, so the evaporator needs more area for the same heat duty.

7.4 Heat transfer: the coefficient and the fouling

The overall heat transfer coefficient U is built from three resistances in series: the condensing steam film, the tube wall, and the boiling liquid film. Ibarz writes it as

1/UA = 1/(h_wA') + e_p/(k_pA_m) + 1/(h_cA'') (18.19)

where h_w is the steam side coefficient, e_p the tube wall thickness, k_p the wall conductivity, A_m the mean area, and h_c the liquid side coefficient. When the areas are nearly equal it simplifies to 1/U = 1/h_w + e_p/k_p + 1/h_c (18.20). In practice the liquid film is usually the biggest resistance, because the heat transfer coefficients from condensing steam are high, so the major resistance to heat flow in an evaporator is usually in the liquid film, as Earle puts it.

Fouling adds a fourth resistance. Scale forms on the tubes from the liquid, and the dirty coefficient U_D is related to the clean coefficient U by 1/U_D = 1/U + R_D (18.21), where R_D is the fouling resistance. Scale cuts the heat transfer, and the evaporator must be cleaned, which is one reason evaporators are designed for easy access to the tubes.

Table 7.2 gives the range of overall coefficients the books expect for each type. The spread is wide, and the choice of evaporator type is largely a choice of U: forced circulation, with the liquid pumped fast past the tubes, gives the highest values, up to 12,000 W/m²·°C, while a calandria with natural circulation gives 800 to 3,000.

Table 7.2: Overall heat transfer coefficients for evaporators (Ibarz Table 18.2)

Evaporator typeU (W/m²·°C)
Long tube, vertical, natural circulation1000-3500
Forced circulation2300-12000
Short tube, horizontal1000-2300
Calandria (propeller)800-3000
Coiled tubes1000-2300
Agitated film, Newtonian, 1 mPa·s2300
Agitated film, Newtonian, 100 mPa·s1800
Agitated film, Newtonian, 10⁴ mPa·s700

Table 7.2: Overall heat transfer coefficients. Source: McCabe, W. L. and Smith, J. C., Unit Operations of Chemical Engineering, 1968, as cited in Ibarz, Table 18.2, p. 632.

Earle adds a working figure for a vertical tube evaporator with distilled water: U is 1,800 to 5,000 J m⁻² s⁻¹ °C⁻¹, and much lower with dissolved solids in the water. Dissolved solids raise the viscosity, thicken the liquid film, and add fouling, all of which pull U down. A design that uses the clean water value for a food liquid will come out too small.

7.5 Multiple effect evaporation: reusing the vapour

A single effect evaporator throws its vapour away, usually to a condenser. A multiple effect evaporator feeds that vapour into the steam chest of the next effect, where it condenses and boils the liquid there. The second effect runs at a lower pressure, so its boiling point is lower, and the vapour from the first effect is still hot enough to boil it. Each effect reuses the heat of the one before, and the economy climbs toward the number of effects.

The pressures and temperatures fall from effect to effect: T > t₁ > t_b₁ > t₂ > t_b₂ > t₃ > t_b₃, and P_c > P₁ > P₂ > P₃, where T is the steam temperature, t the condensing temperature of the vapour in each effect, and t_b the boiling temperature of the liquid. The temperature difference available in each effect is smaller than in a single effect, so each effect needs more area, and the saving in steam is paid for with extra vessels and extra surface. The optimum design balances the operating cost, lower for multiple effects because of the reduced steam consumption, against the capital charges, lower for fewer evaporators.

Feed can enter at the first effect and flow forward with the falling pressure, which is forward feed, or it can enter at the last effect and be pumped forward against the pressure gradient, which is backward feed. Backward feed puts the most viscous liquid, the concentrate, in the first effects at the highest temperatures, where the viscosity is lowest and the heat transfer is best, and it gives a larger capacity, but it can hurt quality because the concentrated product sees the highest temperature. Forward feed is gentler and needs no pumping between effects, because the pressure falls in the direction of flow.

Worked example 7.3: a triple effect evaporator (Earle Example 8.4)

Estimate the steam and heat transfer surface, and the evaporating temperatures in each effect, for a triple effect evaporator evaporating 500 kg h⁻¹ of a 10% solution up to a 30% solution. Steam is available at 200 kPa gauge and the pressure in the evaporation space in the final effect is 60 kPa absolute. The overall heat transfer coefficients are 2,270, 2,000 and 1,420 J m⁻² s⁻¹ °C⁻¹ in the first, second and third effects. Neglect sensible heat effects and assume no boiling point elevation and equal heat transfer in each effect.

Figure 7.5: Triple effect evaporator

Figure 7.5: Triple effect evaporator for Worked example 7.3 (Earle Example 8.4): three effects in series, forward feed, following the arrangement of Earle Fig. 8.2. All flows and temperatures are the book's.

Mass balance, per hour: feed 500 kg, of which 50 kg is solids and 450 kg is liquid. Product is 50/0.30 = 167 kg, of which 50 kg is solids and 117 kg is liquid. Evaporation is 500 - 167 = 333 kg h⁻¹.

Heat balance: from the steam tables, the condensing temperature of steam at 200 kPa gauge is 134°C and the latent heat is 2,164 kJ kg⁻¹. The evaporating temperature in the final effect under 60 kPa absolute is 86°C, and the latent heat is 2,294 kJ kg⁻¹. Equating the heat transfer in each effect, q₁ = q₂ = q₃, so U₁A₁Δt₁ = U₂A₂Δt₂ = U₃A₃Δt₃, and Δt₁ + Δt₂ + Δt₃ = 134 - 86 = 48°C. With equal areas A₁ = A₂ = A₃, Δt₂ = Δt₁U₁/U₂ and Δt₃ = Δt₁U₁/U₃, so Δt₁(1 + 2,270/2,000 + 2,270/1,420) = 3.73Δt₁ = 48, giving Δt₁ = 12.9°C, Δt₂ = 14.6°C and Δt₃ = 20.6°C. The evaporating temperature in the first effect is 134 - 12.9 = 121°C with a latent heat of 2,200 kJ kg⁻¹, in the second effect 121 - 14.5 = 106.5°C with a latent heat of 2,240 kJ kg⁻¹, and in the third effect 106.5 - 20.6 = 86°C with a latent heat of 2,294 kJ kg⁻¹.

Equating the quantities evaporated in each effect, with w₁, w₂ and w₃ the quantities evaporated in effects 1, 2 and 3, and w_s the steam condensed in effect 1: w₁ x 2,200 = w₂ x 2,240 = w₃ x 2,294 = w_s x 2,164, all in kJ. With w₁ + w₂ + w₃ = 333, solving gives w₁ = 113, w₂ = 111 and w₃ = 108 kg h⁻¹, and w_s = 115 kg h⁻¹. It required 115 kg of steam to evaporate 333 kg of water, which is 0.35 kg of steam per kg of water evaporated, an economy of 2.9. Three effects have nearly tripled the economy of the single effect in Example 7.1, from 0.86 to 2.9.

Table 7.3 shows the same pattern in running costs, from data published in 1954. The steam consumption falls from 1.1 kg per kg of water evaporated with one effect to 0.40 with three, and the total running cost falls to 0.37 of the single effect figure. The gain from the second effect is bigger than the gain from the third, which is the usual pattern: each added effect saves less than the one before, while costing as much to build.

Table 7.3: Steam consumption and running costs of evaporators (Earle Table 8.1)

Number of effectsSteam consumption (kg steam/kg water evaporated)Total running cost (relative to a single-effect evaporator)
One1.11
Two0.570.52
Three0.400.37

Table 7.3: Steam consumption and running costs of evaporators. Source: Grosse, H. and Duffield, W. D., 1954, as cited in Earle, Table 8.1, p. 122.

Quick check

Why does a triple effect evaporator use only 0.35 kg of steam per kg of water, when a single effect uses 1.17 kg?

Check your answer

Because the vapour boiled off in the first effect condenses in the second and boils more water there, and the vapour from the second does the same in the third. One kilogram of steam does its work three times over.

7.6 Vapour recompression and the thermal pump

There is another way to reuse the vapour: compress it so that it condenses at a higher temperature, then feed it back as the heating steam. This is vapour recompression, and it can push the economy far above the number of effects, because the same vapour is used again and again.

In mechanical vapour recompression, the vapour is compressed in a compressor, and the work of compression is the energy input instead of fresh steam. The compression is treated as isentropic and read off a Mollier diagram for steam. In thermocompression, a jet of high pressure steam entrains the vapour in a Venturi, and the mixed stream condenses in the heating surface. Ibarz gives the thermocompression balance as Eq. 18.33, from Vián and Ocón, 1967.

The thermal pump is a related idea using two evaporators with a closed heating circuit: the vapour from one evaporator heats the other, and the circuit carries the heat round. Ibarz gives orange juice as the example of a product concentrated this way. The point of all three is the same: the latent heat of the vapour is the biggest energy flow in the plant, and any of it that can be caught and used again is money saved.

7.7 Condensers: getting rid of the vapour

The vapour that is not reused must be condensed, and the condenser is part of the evaporator design. Earle gives two worked examples on the same duty, which show the difference between the two types.

Worked example 7.4: a jet condenser (Earle Example 8.2)

A jet condenser condenses 5,000 kg h⁻¹ of water at a pressure of 20 kPa, corresponding to 15 cm of mercury, with a condensing temperature of 60°C and a latent heat of 2,358 kJ kg⁻¹. Cooling water enters at 18°C and leaves at 35°C at most. The heat removed from the condensate is 2.46 x 10⁶ J kg⁻¹, and the heat taken up by each kg of cooling water is 7.1 x 10⁴ J kg⁻¹. The cooling water needed is 5,000 x 2.46 x 10⁶/7.1 x 10⁴ = 173,000 kg h⁻¹. The cooling water flow is about 35 times the vapour flow: condensing takes a lot of cold water, and the water supply often sets the size of the plant. In a jet condenser the vapour mixes directly with the cooling water, so the two streams leave together.

Figure 7.6: Jet condenser

Figure 7.6: Jet condenser for Worked example 7.4 (Earle Example 8.2): the vapour mixes directly with the cooling water, and the two streams leave together. All flows and temperatures are the book's.

Worked example 7.5: a surface condenser (Earle Example 8.3)

The same duty with a surface condenser, where the vapour condenses on tubes and the cooling water stays separate. With U = 2,270 J m⁻² s⁻¹ °C⁻¹ and a mean temperature difference of 33.5°C, the area needed is 45 m². The surface condenser keeps the condensate clean and recoverable, which matters when the condensate is worth keeping, but it costs a heat exchanger and its area.

Figure 7.7: Surface condenser

Figure 7.7: Surface condenser for Worked example 7.5 (Earle Example 8.3): the vapour condenses on tubes and the cooling water stays separate. All flows and temperatures are the book's.

7.8 The equipment

Earle's Fig. 8.4 shows three evaporator types side by side: a basket type, a long tube type, and a forced circulation type. The choice between them, and the other types, turns on the liquid: its viscosity, its heat sensitivity, and how much it fouls the tubes.

Open pans are the most elementary form: an open pan in which the liquid is boiled, with heat through a steam jacket or coils, and scrapers or paddles for agitation. They are simple and low in capital cost, but expensive to run because the heat economy is poor.

Horizontal tube evaporators close the pan in, with the heating tubes in a horizontal bundle immersed in the liquid at the bottom of a vertical cylinder. Liquid circulation is rather poor in this type, which limits the heat transfer.

Vertical tube evaporators use vertical tubes so that natural circulation gives good heat transfer. The standard evaporator, shown in Earle's Fig. 8.1, is of this type: recirculation is through a large downcomer, so the liquors rise through the vertical tubes, about 5 to 8 cm in diameter, boil in the space just above the upper tube plate, and recirculate through the downcomers. The hydrostatic head reduces boiling on the lower tubes, which are covered by the circulating liquid. The length to diameter ratio of the tubes is of the order of 15:1. The basket evaporator, Fig. 8.4(a), is a variant of the calandria type in which the steam chest is contained in a basket suspended in the lower part of the evaporator, and recirculation occurs through the annular space round the basket.

Plate evaporators adapt the plate heat exchanger: the spacings between the plates are increased and suitable passages provided so that the much larger volume of the vapours, compared with the liquid, can be accommodated. They give good heat transfer and are easy to clean, which matters for food liquids that foul.

Long tube evaporators use tall slender vertical tubes, with a length to diameter ratio of the order of 100:1, passing vertically upward inside the steam chest. The liquid may pass down through the tubes, a falling film evaporator, or be carried up by the evaporating liquor, a climbing film evaporator. Evaporation occurs on the walls of the tubes. Because circulation rates are high and the surface films are thin, good conditions are obtained for concentrating heat sensitive liquids, with high heat transfer rates and short heating times. The liquid is generally not recirculated, and if sufficient evaporation does not occur in one pass, the liquid is fed to another pass. In the climbing film type, slugs of vapour form as the liquid boils on the inside of the tube, and this vapour carries up the remaining liquid, which continues to boil. Tube diameters are of the order of 2.5 to 5 cm, contact times may be as low as 5 to 10 seconds, and overall heat transfer coefficients may be up to five times as great as from a heated surface immersed in a boiling liquid. In the falling film type the tube diameters are rather greater, about 8 cm, and these are specifically suitable for viscous liquids.

Forced circulation evaporators pump the liquid round the circuit, so the liquid film coefficients can be increased by improving the circulation and the velocity of flow across the heating surfaces. Pumps or impellers can be fitted in the liquid circuit. Using pump circulation, the heat exchange surface can be divorced from the boiling and separating sections, as shown in Fig. 8.4(c). Alternatively, impeller blades may be inserted into flow passages such as the downcomer of a calandria type evaporator. Forced circulation is used particularly with viscous liquids, and it may be worth considering for expensive heat exchange surfaces, where corrosion or hygiene requirements make it pay to get the greatest possible heat flow through each square metre.

Scraped surface and agitated film evaporators come under the heading of forced circulation. In one type the material to be evaporated passes down over the interior walls of a heated cylinder and is scraped by rotating scraper blades to maintain a thin film, high heat transfer and a short and controlled residence time exposed to heat. They are the choice for very viscous liquids and pastes that would not flow through tubes at all.

Evaporation for heat sensitive liquids deserves its own paragraph, because so many food products carry volatile flavour constituents that are lost by long heating. They retain more of these if they are evaporated under conditions favouring short contact times with the hot surfaces: climbing film and falling film evaporators, either tubular or plate types, for solutions of low viscosity, and mechanical transport across heated surfaces, scraped film methods, at higher concentrations and higher viscosities.

Worked example 7.6: a climbing film evaporator for tomato juice (Earle Example 8.6)

Tomato juice at 12% solids is concentrated to 28% solids in a climbing film evaporator 3 m high with a tube 4 cm in diameter. The maximum temperature is 57°C, the feed enters at 57°C, the latent heat is 2,366 kJ kg⁻¹, steam is at 170 kPa gauge, and U = 6,000 J m⁻² s⁻¹ °C⁻¹. What is the rate of evaporation from one tube?

Mass balance, on a basis of 100 kg of feed: feed 100 kg, of which 12 kg is solids and 88 kg is liquid. Product is 12/0.28 = 43 kg, of which 12 kg is solids and 31 kg is liquid. Evaporation is 57 kg per 100 kg of feed.

Heat balance: the area of the evaporator tube is πDH = π x 0.04 x 3 = 0.38 m². The condensing steam temperature at 170 kPa is 115°C from the steam tables. The heat transfer is q = UAΔt = 6,000 x 0.38 x (115 - 57) = 1.32 x 10⁵ J s⁻¹. The heat required per kg of feed for evaporation is 0.57 x 2,366 x 10³ = 1.34 x 10⁶ J. The quantity evaporated is 1.32 x 10⁵/1.34 x 10⁶ = 0.1 kg s⁻¹, so the rate of evaporation is 360 kg h⁻¹ from one tube. A battery of such tubes, each evaporating 360 kg h⁻¹, makes up the industrial evaporator.

Figure 7.8: Three evaporator types: basket, long tube and

Figure 7.8: Three evaporator types side by side (Earle Fig. 8.4, p. 113): (a) basket, (b) long tube (climbing film), (c) forced circulation. Placed with Worked example 7.6 (Earle Example 8.6).

Try it yourself: feel the boiling point rise

Dissolve as much table salt as you can in a small pan of water, stir until no more dissolves, and bring it to a rolling boil with a thermometer in the liquid. Compare the reading with the boiling point of plain water in the same pan. The salt water will boil a few degrees higher, and that difference is the boiling point rise. Now put a lid on the pan and turn the heat down: the same rise applies at lower pressure, which is why evaporators can run under vacuum and still need to allow for it.

7.9 What the books do and do not give

The books give the single effect balances, the boiling point rise and the Dühring diagrams, the heat transfer coefficients, the multiple effect design with a full worked triple effect example, vapour recompression and the thermal pump, the condenser sizing, and the equipment types with a worked climbing film example. What they do not give is a worked example of vapour recompression with numbers, so the economy of a recompression system cannot be checked against the books alone, and the thermal pump is described without a worked example. The multiple effect example assumes no boiling point elevation and neglects sensible heat, so a real design must add both back in. The cost figures in Table 7.3 come from 1954, and they show the pattern of costs between one, two and three effects, not present day prices. These gaps are stated here so the reader knows where the books stop.

Pause and think: evaporation is where heat transfer, thermodynamics and economics meet in one machine. The steam bill is the biggest running cost, and every improvement, multiple effects, vapour recompression, a better heat transfer coefficient, is a way of getting more water out for the same steam. The cheapest evaporator to build is rarely the cheapest to run.

Key ideas to carry forward

  • Evaporation removes water from a liquid by boiling; the solids stay behind and the vapour carries only water.
  • Economy is kg of water evaporated per kg of steam used; a good single effect evaporator reaches about 0.86, a triple effect about 2.9.
  • The mass balance is set by the solids: feed solids equal product solids, and the evaporation is the difference.
  • The heat duty comes from the balances, and the area from Q = UAΔT.
  • A solution boils above the boiling point of pure water at the same pressure; the rise grows with concentration and is read from a Dühring diagram.
  • The boiling point rise shrinks ΔT, so concentrated solutions need more heating surface.
  • The liquid film is usually the biggest resistance to heat transfer; dissolved solids and fouling pull U down.
  • Multiple effect evaporation reuses the vapour of one effect as the heating steam of the next, and the economy climbs toward the number of effects.
  • Backward feed puts the viscous concentrate at the highest temperature, where it flows best; forward feed is gentler on quality.
  • Vapour recompression compresses the vapour and uses it again as heating steam, pushing the economy above the number of effects.
  • Condensing takes a lot of cooling water: about 35 times the vapour flow in Example 7.4.
  • Climbing film and falling film evaporators give short contact times of 5 to 10 seconds, which protects volatile flavour in heat sensitive liquids.

Glossary

Agitated film evaporator

An evaporator in which a scraper or agitator keeps the liquid as a thin film on a heated surface. Food tech example: concentrating a thick tomato paste that would not flow through tubes.

Backward feed

Feeding a multiple effect evaporator at the last, lowest pressure effect, so the liquid flows against the pressure gradient toward the first effect. Food tech example: concentrating a viscous sugar liquor, where the thickest liquid gets the highest temperature and the lowest viscosity.

Boiling point rise

The amount by which a solution boils above pure water at the same pressure, growing with concentration. Food tech example: saturated salt solution boiling at 109°C at atmospheric pressure, 9°C above water.

Calandria

A vertical tube evaporator in which the tubes sit in a steam chest and the liquid circulates up through the tubes and down through a central downcomer. Food tech example: the standard evaporator for concentrating milk and juice.

Climbing film evaporator

A long tube evaporator in which the liquid is carried up the tubes by the vapour it generates, boiling as it rises. Food tech example: concentrating tomato juice, with contact times of 5 to 10 seconds.

Condenser

A heat exchanger that condenses the vapour from an evaporator, either by mixing it with cooling water, a jet condenser, or on tubes, a surface condenser. Food tech example: the jet condenser in Example 7.4, using 173,000 kg/h of cooling water.

Dühring diagram

A chart plotting the boiling temperature of a solution against the boiling temperature of pure water at the same pressure, with one line per concentration. Food tech example: finding the boiling point of a sucrose solution from the line for 800 g sucrose per 100 g water.

Economy

Kilograms of water evaporated per kilogram of steam used. Food tech example: the triple effect evaporator in Example 7.3, with an economy of 2.9.

Effect

One vessel in a multiple effect evaporator, heated by the vapour of the previous effect. Food tech example: the second effect of a triple effect evaporator, boiling at 106.5°C.

Falling film evaporator

A long tube evaporator in which the liquid flows down the inside of the tubes as a thin film. Food tech example: concentrating viscous fruit puree, using tubes about 8 cm in diameter.

Forced circulation evaporator

An evaporator in which a pump circulates the liquid fast past the heating surface, raising the heat transfer coefficient. Food tech example: concentrating a viscous liquid where natural circulation would be too slow.

Forward feed

Feeding a multiple effect evaporator at the first, highest pressure effect, so the liquid flows with the falling pressure. Food tech example: concentrating a heat sensitive juice, where the product sees the highest temperature only while it is still dilute.

Fouling resistance

The extra resistance to heat transfer from scale deposited on the heating surface. Food tech example: scale on evaporator tubes cutting the overall coefficient, needing cleaning to restore it.

Multiple effect evaporation

Evaporation in several vessels in series, where the vapour from each effect heats the next. Food tech example: a triple effect evaporator concentrating a 10% solution to 30% with 0.35 kg of steam per kg of water.

Overall heat transfer coefficient

The single number U that combines the steam film, tube wall and liquid film resistances, used in Q = UAΔT. Food tech example: U of 1,700 J/m²·s·°C in the single effect evaporator of Example 7.1.

Thermal pump

A system of two evaporators with a closed heating circuit that carries heat between them, reusing vapour heat. Food tech example: concentrating orange juice, as given by Ibarz.

Thermocompression

Recompressing vapour by entraining it in a jet of high pressure steam, so it can be used again as heating steam. Food tech example: a Venturi jet raising low pressure vapour to the pressure of the heating steam.

Vapour recompression

Compressing the vapour from an evaporator so it condenses at a higher temperature and can be used again as heating steam. Food tech example: mechanical recompression with a compressor, using work instead of fresh steam.

References

  • Ibarz, A. and Barbosa-Cánovas, G. V. Unit Operations in Food Engineering. CRC Press, 2003. Chapter 18.
  • Earle, R. L. Unit Operations in Food Processing. NZIFST, 1983. Chapter 8.
  • Brennan, J. G., Butters, J. R., Cowell, N. D. and Lilly, A. E. V. Food Engineering Operations. Applied Science Publishers, 1976. Chapter 11.
  • McCabe, W. L. and Smith, J. C. Unit Operations of Chemical Engineering. McGraw-Hill, 1968. Cited for Table 18.2 overall heat transfer coefficients.
  • Crapiste, G. H. and Lozano, J. E. Journal of Food Science 53(3), 865-868, 1988. Cited for Table 18.1 Dühring correlation constants.
  • Vián, A. and Ocón, J. Elementos de Ingeniería Química. Aguilar, 1967. Cited for Eq. 18.33 thermocompression.
  • Grosse, H. and Duffield, W. D. 1954. Cited for Table 8.1 steam consumption and running costs.