Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

← All subjects

Unit 2: Fluid Flow, Pumps and Piping

GIFSQ ID: FTN-0114

Unit 2 of 12 in Unit Operations. This page is one unit of the Unit Operations notes.

All units in Unit Operations:

Previous unit: Unit 1: Introduction to Unit Operations, Units and Material and Energy Balances | Next unit: Unit 3: Heat Transfer and Heat Exchangers

Unit 2: Fluid Flow, Pumps and Piping

Note

Put a spoon in a glass of water and stir gently, and the water moves in smooth circles. Stir hard and the circles break into swirls. Pour honey and it crawls; pour milk and it runs. Every pipe, pump and tank in a food factory is a version of that glass, and the difference between a smooth flow and a wild one decides how much power the pump needs, how fast the milk cools, and whether the tomato purée moves at all. This unit is about how fluids move, how to measure that movement, and how to push fluids where they need to go.

Questions to think about

  • What counts as a fluid in food engineering, and why are gases, liquids and fluidized powders grouped together?
  • Why does pressure in a still liquid depend only on depth and density?
  • What does Bernoulli's equation actually say, in words a plant operator could use?
  • Why does honey resist pouring while water does not, and why do some foods refuse to follow the simple rule?
  • What is the Reynolds number, and how does one number tell you whether flow is smooth or turbulent?
  • Where does the energy go when a fluid flows through a pipe, and how do you calculate the loss?
  • How do you choose a pump, and what goes wrong when the pump starves?

2.1 Fluids in the food factory

Many raw materials for foods and many finished foods are in the form of fluids, and these fluids have to be transported and processed in the factory. There is also an increasing tendency to handle powdered and granular materials in a form in which they behave as fluids. Fluidization, as this is called, has been developed because fluid handling is relatively simple compared with the handling of solids.

The engineering idea of a fluid is wider than the everyday one. It covers gases as well as liquids and fluidized solids, because liquids and gases obey many of the same laws, so it is convenient to group them together under the general heading of fluids. Fluids in the food industry vary considerably in their properties. Earle lists them plainly: thin liquids such as milk, water and fruit juices; thick liquids such as syrups, honey, oil and jam; gases such as air, nitrogen and carbon dioxide; and fluidized solids such as grains, flour and peas.

The study of fluids divides into fluids at rest, fluid statics, and fluids in motion, fluid dynamics. For some purposes a further split is needed, into compressible fluids such as gases and incompressible fluids such as liquids.

Ibarz roots the whole subject in transport phenomena. All the physical stages of industrial processes are based on momentum transport, energy transfer and mass transfer. In all three cases, the flow of the transferred property is directly proportional to an impelling force, a velocity, temperature or concentration gradient, and inversely proportional to a resistance that depends on the properties of the system and on the operating conditions. When a system is not in equilibrium, it evolves towards equilibrium by transferring one or more of those properties: a velocity difference is evened out by momentum transport, a temperature difference by heat transport, and a concentration difference by mass transfer. In most operations at least two of the three are present at once, but one usually predominates: momentum transport in fluid transport, sedimentation and filtration; heat transfer in heat exchangers and condensers; mass transfer in absorption, extraction and distillation; and heat and mass together in drying and crystallization.

The three transport laws have the same shape. Newton's law of viscosity says the shear stress in a fluid is proportional to the velocity gradient: shear stress equals viscosity times shear rate. Fourier's law of heat conduction says the heat flux is proportional to the temperature gradient. Fick's law says the mass flux is proportional to the concentration gradient. In each case a flux equals a property of the material times a gradient. That shared shape is why one chapter of mathematics serves three kinds of equipment.

Quick check

Name one food operation where momentum transport predominates, one where heat transfer predominates, and one where mass transfer predominates.

Check your answer

Momentum: pumping milk through a pipe. Heat: a plate heat exchanger heating milk. Mass: distillation of an alcohol and water mixture, or extraction of oil from a seed.

2.2 Fluid statics: pressure in a liquid at rest

A very important property of a fluid at rest is the pressure it exerts on its surroundings. Under gravity, a mass of material exerts a force on whatever supports it, equal to the mass multiplied by the acceleration due to gravity. The mass of a fluid is its volume multiplied by its density, which is its mass per unit volume. So the force is F = Vρg, where F is the force, V is the volume, ρ is the density and g is the acceleration due to gravity, 9.81 m s⁻².

Lower levels of a fluid must support the fluid above them. Since fluids at rest cannot sustain shearing forces, which are forces tending to move adjacent layers relative to one another, the forces at any point in a fluid at rest are equal in all directions. The force per unit area in a fluid is called the fluid pressure, and it is exerted equally in all directions.

Consider a horizontal plane in a fluid at a depth Z below the surface. The volume of fluid above an area A on the plane is ZA, and its weight is ZρAg. Adding any force on the surface of the liquid, the total force is F = AP₁ + ZρAg, where P₁ is the pressure above the surface. Dividing by the area gives the fundamental equation of fluid pressure:

P = P₁ + Zρg

Taking the pressure at the fluid surface as the datum, this becomes P = Zρg. The pressure at any depth in a fluid is given by the product of the density of the fluid and the depth. The shape of the vessel makes no difference.

Worked example: pressure in a spherical tank of peanut oil (Earle Example 3.1)

Calculate the greatest pressure in a spherical tank, of 2 m diameter, filled with peanut oil of specific gravity 0.92, if the pressure measured at the highest point in the tank is 70 kPa. The density of water is 1000 kg m⁻³, so the density of the oil is 0.92 x 1000 = 920 kg m⁻³, and the greatest depth is 2 m. The pressure due to depth is P = Zρg = 2 x 920 x 9.81 = 18,050 Pa = 18.1 kPa. Adding the pressure at the surface gives a total pressure of 70 + 18.1 = 88.1 kPa. The fact that the tank is spherical makes no difference to the pressure at the bottom.

Diagram: Pressure in a spherical tank (Earle Example 3.1)

Pressure at the top 70 kPa

↓

Spherical tank, diameter 2 m
Peanut oil, specific gravity 0.92
Density 920 kg m⁻³

↓

Greatest depth 2 m; pressure due to depth 18.1 kPa

Greatest pressure at the bottom 88.1 kPa

Diagram for Earle Example 3.1: pressure rises with depth in the spherical tank.

Worked example: head of water for one atmosphere (Earle Example 3.2)

Calculate the head of water equivalent to standard atmospheric pressure of 100 kPa. From Z = P/ρg, the head is 100 x 10³ / (1000 x 9.81) = 10.2 m of water. Pressures are often expressed as heads of a fluid, because they are often measured by observing the height of a column of liquid that the pressure can support. The two fluids most commonly used are water and mercury.

Diagram: Head of water for one atmosphere (Earle Example 3.2)

Pressure 100 kPa

↓

Column of water
Head 10.2 m

↓

Head = P / ρg = 100 x 10³ / (1000 x 9.81) = 10.2 m of water

Diagram for Earle Example 3.2: one atmosphere is a head of 10.2 m of water.

Pressures are quoted as absolute pressures, which include atmospheric pressure, or as gauge pressures, which are measured above atmospheric pressure as the datum. If the absolute pressure is 350 kPa, the gauge pressure is (350 - 100) = 250 kPa, taking atmospheric pressure as 100 kPa. Standard atmospheric pressure is actually 101.3 kPa, but for practical purposes 100 kPa is close enough and most convenient. A vacuum is a pressure below atmospheric: a reading of 40 kPa absolute is a vacuum of about 60 kPa, and 101.3 kPa vacuum on the gauge is a complete vacuum.

Quick check

Two tanks hold water, one tall and narrow, one short and wide. Both are filled to a depth of 2 m. In which tank is the pressure at the bottom greater?

Check your answer

Neither: the pressure is the same in both, because pressure depends only on depth and density, not on the shape or the width of the tank.

2.3 Mass balance in flow: the continuity equation

In most processes fluids have to be moved, so the study of fluids in motion matters. Flow problems are solved by applying the conservation of mass and the conservation of energy. In any system, or in any part of any system, it must always be possible to write a mass balance and an energy balance, and these are the basis for the design of fluid handling equipment.

Consider a continuous pipe which changes its diameter, passing into and out of a unit of processing plant such as a pasteurizing heat exchanger, with a pump to provide the energy to move the fluid. Once the system is working steadily, and if there is no accumulation of fluid in any part, the quantity of fluid that goes in at one section must come out at the other. If the area of the pipe at section 1 is A₁, the velocity v₁, the density ρ₁, and the corresponding values at section 2 are A₂, v₂, ρ₂, the mass balance is:

ρ₁A₁v₁ = ρ₂A₂v₂

If the fluid is incompressible, the densities are equal, so A₁v₁ = A₂v₂. This is the continuity equation for liquids, and it is frequently used in solving flow problems. It can also be used for gas flow where the change in pressure is very small, such as in many air ducting systems, without serious error. The volume flow rate, Av, is the same at every section of the pipe: where the pipe narrows, the velocity must rise.

Worked example: milk into a centrifuge (Earle Example 3.4)

Whole milk is flowing into a centrifuge through a full 5 cm diameter pipe at a velocity of 0.22 m s⁻¹. In the centrifuge it is separated into cream of specific gravity 1.01 and skim milk of specific gravity 1.04. Calculate the velocities of flow of skim milk and of cream if they are discharged through 2 cm diameter pipes. The specific gravity of whole milk is 1.035.

The areas are A₁ = (π/4)(0.05)² = 1.96 x 10⁻³ m² and A₂ = A₃ = (π/4)(0.02)² = 3.14 x 10⁻⁴ m². The volume balance gives A₁v₁ = A₂v₂ + A₃v₃, and the mass balance gives ρ₁A₁v₁ = ρ₂A₂v₂ + ρ₃A₃v₃. Combining them gives A₁v₁(ρ₁ - ρ₂) = A₃v₃(ρ₃ - ρ₂). With densities of 1035, 1040 and 1010 kg m⁻³ for whole milk, skim milk and cream, the cream velocity is 0.23 m s⁻¹ and the skim milk velocity is 1.1 m s⁻¹. The skim milk, which carries most of the volume, flows much faster through its small pipe.

Diagram: Milk into a centrifuge (Earle Example 3.4)

In: whole milk, 5 cm pipe, 0.22 m s⁻¹, specific gravity 1.035

↓

Centrifuge

↓

Out: cream, 2 cm pipe, 0.23 m s⁻¹, specific gravity 1.01

Out: skim milk, 2 cm pipe, 1.1 m s⁻¹, specific gravity 1.04

Diagram for Earle Example 3.4: whole milk splits into cream and skim milk in the centrifuge.

2.4 Energy balance in flow: Bernoulli's equation

Besides the mass balance, the energy balance must be written. Consider the changes in the total energy of one kilogram of fluid between section 1 and section 2. There are changes in the intrinsic energy of the fluid itself: potential energy, Zg joules per kg for a height Z above the datum; kinetic energy, v²/2 joules per kg; and pressure energy, P/ρ joules per kg, which is the work the fluid can do as its pressure is released. There is also energy interchange with the surroundings: energy lost to the surroundings due to friction, E_f; mechanical energy added by pumps, E_c; and heat energy in heating or cooling the fluid.

Writing the energy balance for one kilogram between the two sections gives:

Z₁g + v₁²/2 + P₁/ρ₁ = Z₂g + v₂²/2 + P₂/ρ₂ + E_f - E_c

In the special case where no mechanical energy is added and the fluid is frictionless, E_f and E_c are zero, and the equation becomes Zg + v²/2 + P/ρ = k, where k is a constant. This is Bernoulli's equation, first discovered by the Swiss mathematician Bernoulli in 1738, and it is one of the foundations of fluid mechanics. It is a mathematical expression, for fluid flow, of the principle of conservation of energy.

The equation can be written in three forms. As written above, the terms are energies per unit mass. Multiply both sides by the density and the terms become pressures: ρZg + ρv²/2 + P = k'. Divide by g and the terms become heads of fluid: Z + v²/2g + P/ρg = k'', with the potential head, the velocity head and the pressure head. The most convenient form is chosen for each case, but the choice must be kept consistent.

If there is a constriction in a pipe and the static pressures are measured upstream and in the constriction, Bernoulli's equation can be used to calculate the rate of flow, if the flow areas are known. For a horizontal pipe with areas A₁ and A₂, the pressure difference is P₁ - P₂ = ρv₁²(A₁²/A₂² - 1)/2, and the unknown velocity follows. A nozzle in the side of a tank discharges with a velocity v = √(2gH), where H is the head of fluid above the nozzle.

Worked example: water through a reducing pipe (Earle Example 3.5)

Water flows at 0.4 m³ per minute in a 7.5 cm diameter pipe at a pressure of 70 kPa. If the pipe reduces to 5 cm diameter, calculate the new pressure. The density of water is 1000 kg m⁻³. The area of the 7.5 cm pipe is 4.42 x 10⁻³ m², so the velocity is (0.4/60)/4.42 x 10⁻³ = 1.51 m s⁻¹. The area of the 5 cm pipe is 1.96 x 10⁻³ m², so the velocity is 3.4 m s⁻¹. Bernoulli's equation, with no change in height, gives 1.51²/2 + 70,000/1000 = 3.4²/2 + P₂/1000, so 1.1 + 70 = 5.8 + P₂/1000, and P₂ = 65.3 kPa. The pressure falls as the velocity rises.

Diagram: Water through a reducing pipe (Earle Example 3.5)

Flow 0.4 m³ per minute

↓

Pipe 7.5 cm diameter
Velocity 1.51 m s⁻¹, pressure 70 kPa

↓

Pipe 5 cm diameter
Velocity 3.4 m s⁻¹, pressure 65.3 kPa

The pressure falls as the velocity rises

Diagram for Earle Example 3.5: water speeds up and loses pressure in the smaller pipe.

Worked example: olive oil through a constriction (Earle Example 3.6)

Olive oil of specific gravity 0.92 is flowing in a pipe of 2 cm diameter. A constriction reduces the diameter to 1.2 cm, and the measured pressure difference between the clear pipe and the most constricted part is 8 cm of water. Calculate the flow rate of the olive oil. The differential pressure is 9.81 x 1000 x 0.08 = 785 Pa. The ratio of areas squared is (2/1.2)⁴ = 7.72. Substituting in the constriction equation, 785 = 0.92 x 1000 x v²(7.72 - 1)/2, which gives v = 0.5 m s⁻¹ in the clear pipe. The flow rate is the area times the velocity, 3.14 x 10⁻⁴ x 0.5 = 1.57 x 10⁻⁴ m³ s⁻¹.

Diagram: Olive oil through a constriction (Earle Example 3.6)

Olive oil, specific gravity 0.92

↓

Pipe 2 cm diameter
Velocity 0.5 m s⁻¹

↓

Constriction 1.2 cm diameter

Pressure difference 8 cm of water (785 Pa)

Flow rate 1.57 x 10⁻⁴ m³ s⁻¹

Diagram for Earle Example 3.6: the constriction drops the pressure by 8 cm of water.

Worked example: water level in a storage tank (Earle Example 3.7)

The level of water in a storage tank is 4.7 m above the exit pipe. The tank is at atmospheric pressure and the exit pipe discharges into the air. If the diameter of the exit pipe is 1.2 cm, what is the mass rate of flow through the pipe? From the nozzle equation, v = √(2gH) = √(2 x 9.81 x 4.7) = 9.6 m s⁻¹. The area of the pipe is (π/4)(0.012)² = 1.13 x 10⁻⁴ m², so the volumetric flow is 1.13 x 10⁻⁴ x 9.6 = 1.08 x 10⁻³ m³ s⁻¹, and the mass rate is 1.08 kg s⁻¹.

Diagram: Water level in a storage tank (Earle Example 3.7)

Storage tank, water level 4.7 m above the exit pipe

↓

Exit pipe 1.2 cm diameter
Velocity 9.6 m s⁻¹

↓

Mass rate of flow 1.08 kg s⁻¹

Diagram for Earle Example 3.7: the tank head of 4.7 m drives the flow out of the pipe.

Worked example: pump power to raise water (Earle Example 3.8)

Water is raised from a reservoir up 35 m to a storage tank through a 7.5 cm diameter pipe. It is required to raise 1.6 cubic metres of water per minute. Calculate the horsepower input to a pump, assuming the pump is 100% efficient and there is no friction loss in the pipe. One horsepower is 0.746 kW. The volume flow is 1.6/60 = 2.7 x 10⁻² m³ s⁻¹, and the velocity in the pipe is 2.7 x 10⁻² / 4.42 x 10⁻³ = 6.1 m s⁻¹. The energy per kg is Zg + v²/2 = 35 x 9.81 + 6.1²/2 = 343.4 + 18.6 = 362 J kg⁻¹. The mass rate is 26.7 kg s⁻¹, so the power is 362 x 26.7 = 9665 W, which is 13 horsepower.

Diagram: Pump power to raise water (Earle Example 3.8)

Reservoir

↓

Pump

↓

Pipe 7.5 cm diameter; flow 1.6 m³ per minute; velocity 6.1 m s⁻¹

↓

Storage tank 35 m up

Power 9665 W, which is 13 horsepower

Diagram for Earle Example 3.8: the pump lifts water 35 m to the storage tank.

Quick check

A pipe narrows to half its diameter. What happens to the velocity, and what happens to the pressure?

Check your answer

The area falls to a quarter, so the velocity rises four times by continuity. By Bernoulli, the pressure falls as the velocity rises.

2.5 Viscosity: why honey crawls and water runs

Viscosity is the property of a fluid which gives rise to forces that resist the relative movement of adjacent layers in the fluid. Viscous forces are like shear forces in solids, and they arise from forces between the molecules. If two parallel plane elements in a fluid are moving relative to one another, a steady force must be applied to maintain a constant relative speed. That force is called the viscous drag.

If the planes are a distance Z apart and their relative velocity is v, the force F required has been found experimentally to be proportional to v and inversely proportional to Z for many fluids. The coefficient of proportionality is the viscosity, denoted by the symbol μ (mu):

F/A = μv/Z

The unit of viscosity is the N s m⁻², which can also be written as kg m⁻¹ s⁻¹. The older unit, the poise, is still met: 10 poises, or 1000 centipoises, equal 1 N s m⁻². The viscosity of water at room temperature is around 1 x 10⁻³ N s m⁻². For comparison, at the same temperature, acetone is 0.3 x 10⁻³, tomato pulp is 3 x 10⁻³, olive oil is 100 x 10⁻³, and molasses is 7 N s m⁻². Viscosity depends strongly on temperature, decreasing sharply as the temperature rises: the viscosity of golden syrup is about 100 N s m⁻² at 16 °C, 40 at 22 °C and 20 at 25 °C.

Care must be taken not to confuse the dynamic or absolute viscosity μ with μ/ρ, which is called the kinematic viscosity and is given another symbol. In technical literature, viscosities are often given in units derived from the equipment used to measure them, such as Saybolt Seconds or Redwood Seconds, and tables convert those arbitrary units to poises.

2.6 Newtonian and non-Newtonian fluids

From the definition of viscosity, the shear stress τ (tau) in a fluid can be written as τ = μ(dv/dZ), where dv/dZ is the shear rate, the rate at which velocity changes with distance. That equation was proposed by Newton, and fluids that obey it, such as water, are called Newtonian. For many fluids in the food industry, measurements show deviations from this simple relationship, leading to the more general power law equation:

τ = k(dv/dZ)ⁿ

where k is a constant of proportionality and n is the flow behaviour index. Where n = 1 the fluids are Newtonian and k = μ. All other fluids are called non-Newtonian, and they divide broadly into two kinds. Those with n less than 1 give a concave downward curve of shear stress against shear rate: the apparent viscosity is high under low shear forces and falls as the shear force increases. Such fluids are called pseudoplastic, and tomato purée is the book's example. In more extreme cases there is no flow at all until a yield stress is reached, after which flow occurs, and these fluids are called thixotropic. Those with n greater than 1 have a low apparent viscosity under low shear stresses and become more viscous as the shear rises. This is called dilatancy, and gritty slurries such as crystallized sugar solutions are the example. Again there is a more extreme condition with a zero apparent viscosity under low shear, and such materials are called rheopectic.

Ibarz gives the same behaviour in four rheological models, all variants of the Herschel-Bulkley model: Newton's equation σ = ηγ̇; the power law σ = Kγ̇ⁿ; Bingham's equation σ = σ₀ + η'γ̇, where σ₀ is a yield stress and η' is the plastic viscosity; and the Herschel-Bulkley model σ = σ₀ + K_Hγ̇ⁿ. The first three are variants of the fourth: Newton's law when the yield stress is zero and n is one, the power law when the yield stress is zero, and Bingham's equation when η' equals K_H and n equals one.

In practice, non-Newtonian behaviour matters whenever materials that ought to pump easily just do not. They get stuck in the pipes, overload the pumps, or need specially designed fittings before they can be moved. Sometimes it is enough just to be aware of the general classes of behaviour. In other cases it is necessary to determine the rheological properties experimentally so that equipment and processes can be properly designed.

Quick check

Tomato purée flows more easily the harder you stir it. Which class of fluid is it, and is its flow behaviour index n above or below 1?

Check your answer

Pseudoplastic, with n below 1: the apparent viscosity falls as the shear rate rises.

2.7 Reynolds' experiment: smooth flow and wild flow

When a liquid flowing in a pipe is watched carefully, the pattern of flow becomes more disturbed as the velocity of flow increases. At low velocities the flow is calm. Reynolds showed this by injecting a thin stream of dye into the fluid and finding that it ran in a smooth stream in the direction of the flow. As the velocity increased, the smooth line of dye was broken up until, at high velocities, the dye was rapidly mixed into the disturbed flow of the surrounding fluid.

Ibarz describes the experiment in detail. Water circulated through transparent tubing of constant cross section, with the velocity varied by a valve at the entrance. A coloured solution was introduced in the middle of the pipes at the entrance section, and the coloured vein was watched along the pipes at different velocities. At low velocity the coloured vein does not lose its identity while circulating through the centre of the pipes, and although a low and progressive increase of the vein's width can be seen, there is no mixture in the transverse sense: the flow takes place as parallel streams with no interference between them, and mass exchange occurs only at the molecular level. As the velocity increases, oscillations appear in the coloured filament until, at a certain velocity, it breaks into whirlpools and floods the pipe transversely. For high velocities there is movement of the liquid in a transverse way of macroscopic proportions, with rapid movement in the form of whirlpools with no pre-established direction in the transverse section of the pipe. That regime is called turbulent.

Figure 2.1: Reynolds experiment: the dye filament

Figure 2.1: Reynolds' experiment. A dye filament stays thin and straight at low velocity, wavers and spreads as velocity rises, and breaks into eddies at high velocity. Reproduced from Ibarz, Fig. 3.1, p. 46.

Reynolds concluded that the instability could be predicted from the ratio of the kinetic forces and the viscous forces in the fluid stream. The kinetic forces tend to maintain the flow in its general direction, whereas the viscous forces tend to retard the motion and introduce eddies. The inertial force is proportional to the velocity pressure ρv², and the viscous drag is proportional to μv/D, where D is the diameter of the pipe. The ratio of these forces is ρvD/μ. That ratio is dimensionless, it is called the Reynolds number, and it is denoted by Re:

Re = Dvρ/μ

From a host of experimental measurements on fluid flow in pipes, Earle gives the boundaries as: for Re below 2100, streamline flow; for Re between 2100 and 4000, transition, where the pattern is unstable and any slight disturbance upsets it, although streamline flow can be maintained if there is no disturbance; and for Re above 4000, turbulent flow. Ibarz gives the same critical value of 2100 for Newtonian fluids, with a transition range above it, and the regime completely turbulent for values above 10,000. The difference between the two books is a matter of where fully developed turbulence is taken to begin, and this unit keeps both statements so the reader is not surprised to meet either number.

Worked example: is milk flow turbulent? (Earle Example 3.9)

Milk is flowing at 0.12 m³ per minute in a 2.5 cm diameter pipe. If the temperature of the milk is 21 °C, is the flow turbulent or streamline? The viscosity of milk at 21 °C is 2.1 cP, which is 2.1 x 10⁻³ Pa s, and the density is 1029 kg m⁻³. The diameter is 0.025 m and the cross sectional area is 4.9 x 10⁻⁴ m². The velocity is (0.12/60)/4.9 x 10⁻⁴ = 4.1 m s⁻¹. The Reynolds number is (0.025 x 4.1 x 1029)/(2.1 x 10⁻³) = 50,230. That is greater than 4000, so the flow is turbulent.

Diagram: Is milk flow turbulent? (Earle Example 3.9)

Milk at 21 °C, density 1029 kg m⁻³, viscosity 2.1 x 10⁻³ Pa s

↓

Pipe 2.5 cm diameter
Flow 0.12 m³ per minute
Velocity 4.1 m s⁻¹

↓

Reynolds number 50,230, greater than 4000: turbulent

Diagram for Earle Example 3.9: milk at 4.1 m s⁻¹ in a 2.5 cm pipe is turbulent.

Because Re is dimensionless, its numerical value is the same whatever units are used, provided the units are consistent throughout. If centimetres were used instead of metres just in the diameter term, the value would be greater by a factor of 10, which would make nonsense of any deduction from the number.

Quick check

Water flows in a pipe at Re = 1500. Honey flows in the same pipe at Re = 50. Which flow is streamline, and which fluid has the higher viscosity relative to its speed?

Check your answer

Both are streamline, since both are below 2100. The honey has the lower Reynolds number, so viscous forces dominate more strongly in the honey flow.

2.8 Friction in pipes: the price of moving fluid

In Bernoulli's equation the symbol E_f denotes the energy loss due to friction in the pipe. That loss has been shown, both theoretically and experimentally, to be related to the Reynolds number for the flow. It is also proportional to the velocity pressure of the fluid and to a factor related to the smoothness of the surface over which the fluid is flowing.

If the wall friction is defined in terms of the velocity pressure, F/A = fρv²/2, where F is the friction force, A is the area over which it acts, and f is a coefficient called the friction factor, then an energy balance over a length L of straight horizontal pipe of diameter D gives the Fanning equation:

ΔP_f = (4fρv²/2)(L/D)

and the frictional loss of energy is E_f = ΔP_f/ρ = (4fv²/2)(L/D). The equation is also called the Fanning-Darcy equation, and it is used to calculate the pressure drop which occurs when liquids flow in pipes.

The factor f depends on the Reynolds number and on the roughness of the pipe. Earle's Fig. 3.8 plots experimental results showing that relationship. For low values of Re there is a simple relationship between f and Re, independent of the roughness of the pipe, because in streamline flow there is a stationary boundary layer at the wall and no liquid movement over any roughness at the wall. In streamline flow the friction factor can be predicted theoretically from the Hagen-Poiseuille equation:

f = 16/(Re), for 0 < (Re) < 2100

For smooth pipes in the range 3000 < (Re) < 100,000, the Blasius equation applies: f = 0.316/(Re)^0.25 in the Fanning form used by Earle. In the turbulent region a number of curves are shown, one for each roughness ratio, which is the ratio of the average height of the projections making up the roughness on the wall to the pipe diameter.

Some writers use values for f which differ from Earle's definition by numerical factors of 2 or 4, using the same symbol f, so when reading off values for f its definition in the particular context should always be checked. For example, a new factor f' = 4f removes the numerical factor from the Fanning equation. Ibarz uses the Darcy form, written as 4f, and that difference is the reason the two books' Moody diagrams look different while saying the same thing.

The roughness of a pipe is given in Earle's Table 3.1 as the roughness factor ε in metres:

Table 2.1: Relative roughness factors for pipes (Earle Table 3.1)

MaterialRoughness factor ε (m)MaterialRoughness factor ε (m)
Riveted steel0.001-0.01Galvanized iron0.0002
Concrete0.0003-0.003Asphalted cast iron0.001
Wood staves0.0002-0.003Commercial steel0.00005
Cast iron0.0003Drawn tubingSmooth

Table 2.1: Roughness factors for pipes, Earle Table 3.1, p. 36.

Figure 2.2: Friction factors in pipe flow (Moody chart)

Figure 2.2: Friction factors in pipe flow. The laminar line is f = 16/Re; the turbulent curves are labelled by the roughness ratio ε/D. The curves are drawn from the Colebrook relation, which the book cites as the fit to these curves, with the laminar line exact; the individual curve positions are a faithful redrawing of the printed chart and are flagged as such in DIAGRAM-FLAGS.md. Reproduced from Earle, Fig. 3.8, p. 35, from Moody (1944) by permission.

Worked example: pressure drop for olive oil (Earle Example 3.10)

Calculate the pressure drop along 170 m of 5 cm diameter steel pipe through which olive oil at 20 °C is flowing at the rate of 0.1 m³ per minute. The viscosity of olive oil at 20 °C is 84 x 10⁻³ Pa s and the density is 910 kg m⁻³. The diameter is 0.05 m and the cross sectional area is 1.96 x 10⁻³ m². The velocity is (0.1/60)/1.96 x 10⁻³ = 0.85 m s⁻¹. The Reynolds number is (0.05 x 0.85 x 910)/(84 x 10⁻³) = 460, so the flow is streamline, and from Fig. 3.8 the friction factor is about 0.03, which agrees with the theoretical value 16/(Re) = 0.035 within chart reading accuracy. The pressure drop from the Fanning equation is ΔP = (4 x 0.03 x 910 x 0.85²/2) x (170/0.05) = 1.34 x 10⁵ Pa = 134 kPa.

2.9 The Moody diagram in Ibarz: the same chart, the other friction factor

Ibarz gives the same chart in the Darcy form, where the vertical axis is 4f, the Darcy friction factor. The chart covers Reynolds numbers from 10³ to 10⁸ and 4f from 0.008 to 0.1, with the zones marked as Laminar zone, Critical zone, Transition zone, Turbulent zone, and Rough pipings, complete turbulence. The laminar line is 4f = 64/Re. A dashed curve crosses the chart from the transition zone down to the smooth pipe curve. The two roughness curves labelled on the chart are ε/d = 0.000001 and ε/d = 0.000005.

The text beside the chart gives the working rules. For Reynolds numbers smaller than 2100, the variation of 4f with Re is linear, which agrees with the laminar equation. In the turbulent zone, the curves fit with a small error to the Colebrook equation. In the transition zone, for Reynolds numbers between 2100 and 4000, a relation that gives good results is f = 0.71 x 10⁻⁹(Re)². Another correlation frequently used for smooth pipes is 1/(4f)^0.5 = 1.80 log(Re/6.81). The practical way to calculate the friction factor is from the Moody diagram, where the friction factor is a function of the Reynolds number and the relative rugosity ε/d.

Figure 2.3: Moody's diagram for Newtonian fluids

Figure 2.3: Moody's diagram for Newtonian fluids. The vertical axis is 4f, the Darcy friction factor, and the horizontal axis is the Reynolds number, both on log scales. The laminar line is 4f = 64/Re and is exact. The two roughness curves labelled on the book chart are ε/d = 0.000001 and ε/d = 0.000005. Reproduced from Ibarz, Fig. 7.14, p. 171.

Ibarz Table 7.1 gives the rugosity ε of pipe materials in millimetres. Note that Earle's Table 3.1 and Ibarz Table 7.1 give slightly different values for the same materials, because they come from different sources; use one table consistently within a calculation and say which one.

Table 2.2: Rugosity of pipes (Ibarz Table 7.1)

Materialε (mm)
Concrete0.3-3
Cast iron0.26
Asphalted cast iron0.12
Galvanized iron0.15
Wrought iron0.046
Commercial steel0.046
Riveted steel1-10
Drain piping0.0015

Table 2.2: Rugosity of pipes, Ibarz Table 7.1, p. 187.

Quick check

A designer reads f = 0.005 from a chart that uses the Fanning definition, then uses it in an equation that expects the Darcy factor. What factor is wrong, and by how much?

Check your answer

The Darcy factor is 4f, so the Darcy value is 0.02, four times the Fanning value. Using 0.005 in a Darcy equation would understate the pressure drop by a factor of four.

2.10 Bends, valves and fittings: small pieces, large losses

When the direction of flow is altered or distorted, as when the fluid flows round bends in the pipe or through fittings of varying cross section, energy losses occur which are not recovered. The energy is dissipated in eddies and additional turbulence and finally lost in the form of heat. However, that energy must be supplied if the fluid is to be maintained in motion, in the same way as energy must be provided to overcome friction. Losses in fittings have been found to be proportional to the velocity head of the fluid, and the energy loss is expressed as:

E_f = kv²/2

where k has to be found for the particular fitting. Values of k for some fittings are given in Earle's Table 3.2, and a fuller set is given in Ibarz Table 7.3.

Energy is also lost at sudden changes in pipe cross section. At a sudden enlargement the loss is (v₁ - v₂)²/2, where v₁ is the velocity upstream and v₂ the velocity downstream. At a sudden contraction the loss is kv²/2, where k depends on the ratio of the pipe diameters, as in Earle's Table 3.3: for D₁/D₂ of 0.1, 0.3, 0.5, 0.7 and 0.9, k is 0.36, 0.31, 0.22, 0.11 and 0.02.

Table 2.3: Friction loss factors in fittings (Earle Table 3.2, selected values)

Fittingk
Valves, fully open: gate0.13
Valves, fully open: globe6.0
Valves, fully open: angle3.0
Elbows: 90 degree standard0.74
Elbows: medium sweep0.5
Elbows: long radius0.25
Tee, straight through0.5
Entrance, large tank to pipe: sharp0.5
Entrance, large tank to pipe: rounded0.05

Table 2.3: Friction loss factors in fittings, Earle Table 3.2, p. 37. Two further rows of the book table, the square elbow and the tee used as an elbow, could not be read reliably from the scanned page and are left out rather than guessed.

A globe valve, with k of 6.0, costs about forty six times as much energy as a fully open gate valve, with k of 0.13. That is why gate valves are used where the valve stays open, and globe valves where flow must be throttled. A sharp entrance costs ten times a rounded one.

Ibarz gives the same losses as equivalent lengths of straight pipe. A fictitious length of straight pipe is added to the actual length, such that the friction due to the fictitious pipe is the same as that from the fitting. Since the fitting loss kv²/2 equals the pipe friction loss, k can be replaced by 4fL_e/D, where L_e is the equivalent length. Table 7.2 gives the equivalent length in pipe diameters for turbulent flow only.

Table 2.4: Equivalent length of different fittings, for turbulent flow only (Ibarz Table 7.2)

FittingL_e/d
45 degree elbow standard15
90 degree elbow standard30
90 degree elbow long radius20
180 degree return elbow75
Tee standard, used as elbow, central entrance90
Tee standard, used as elbow, entrance by lateral branch60
Tee standard, straight passing20
Check valve, fully open300
Angle valve, fully open170
Gate valve, fully open7
Gate valve, 1/4 open900
Gate valve, 1/2 open200
Gate valve, 3/4 open40
Ordinary entrance16
Borda entrance30
Rounded entrance, joints, couplingsNegligible

Table 2.4: Equivalent length of different fittings, Ibarz Table 7.2, p. 176. Source given in the book: Levenspiel, Flujo de Fluidos, Intercambio de Calor, Reverte, Barcelona, 1993.

A gate valve that is only a quarter open is equivalent to 900 pipe diameters of straight pipe, while the same valve fully open is only 7. A half closed gate valve is a very expensive way to throttle a flow.

Table 2.5: Resistance factors k (Ibarz Table 7.3, selected values)

FittingkFittingk
45 degree elbow standard0.35Gate valve, fully open0.17
45 degree elbow great curvature0.20Gate valve, 3/4 open0.90
90 degree elbow standard0.75Gate valve, 1/2 open4.50
90 degree elbow great curvature0.45Gate valve, 1/4 open24.00
90 degree elbow small curvature1.30Check valve, fully open9.00
180 degree curve1.50Check valve, 1/2 open36.0
Tee standard, with closed fork0.40Check valve, 1/4 open112.0
Tee standard, used as elbow1.00Diaphragm valve, fully open2.30
Tee standard, with flow division1.00Angle valve, fully open2.00
Threaded joints0.04Bottom valve15.0
Entrance, trumpet shaped0.78Entrance, sharp edges0.50
Entrance, slightly rounded0.23Entrance, fully rounded0.04
Exit, trumpet shaped, sharp edges or rounded1.00Retention valve, ball70.00

Table 2.5: Resistance factors k, Ibarz Table 7.3, p. 178. Selected values; the full table in the book also gives ball and butterfly valve factors at 5, 10, 20, 40 and 60 degrees closed, and flowmeter factors for disk, piston, revolving and turbine meters.

These resistance factors are valid only for fluids with Newtonian behaviour. For non-Newtonian fluids the available information is limited. Steffe and co-workers reported that the factors increase as the generalized Reynolds number decreases, with expressions for three way valves, tee fittings and 90 degree elbows that depend on the generalized Reynolds number raised to a negative power.

Pressure drops through equipment such as banks of tubes in heat exchangers, or beds of packed solids, are not easy to calculate even if the properties of the solids are well known, and accurate pressure drop information generally needs experimental measurement. Two useful generalizations hold: pressure drops through equipment are in general proportional to the square of the velocity, and power requirements are proportional to the product of the pressure drop and the mass rate of flow, that is to the cube of the velocity. Doubling the flow rate through a pipe roughly doubles the pressure drop four times and the power eight times.

Practical note: when a pump cannot keep up, the first thing to check is not the pump but the line: a half closed gate valve, a globe valve left in a line that should have a gate valve, or a sharp entrance can cost more head than a hundred metres of straight pipe.

2.11 Measuring pressure and flow

Two practical aspects of fluid flow are measurement and the production of flow by pumps and fans. Only by measuring variables such as pressure and velocity can the flow of the fluid be controlled.

The simplest method of measuring pressure is the piezometer tube, a tube containing the fluid under pressure in which the fluid is allowed to rise to a height that corresponds to the excess of the pressure over its surroundings. The head can be related to the pressure by P = ρZg. A development of the piezometer is the U-tube, in which another fluid is introduced which must be immiscible with the fluid whose pressure is being measured. The unknown pressure is then equal to the difference between the levels of the measuring fluid in the two arms of the U-tube.

Worked example: vacuum in an evaporator (Earle Example 4.1)

The pressure in a vacuum evaporator was measured and found to be less than atmospheric pressure by 25 cm of mercury, as measured in a U-tube. Calculate the vacuum and the absolute pressure in the evaporator. The atmospheric pressure is 75.4 cm of mercury and the specific gravity of mercury is 13.6. The vacuum is P = 13.6 x 1000 x 0.25 x 9.81 = 33.4 kPa. The atmospheric pressure is 13.6 x 1000 x 0.754 x 9.81 = 100.6 kPa, so the absolute pressure in the evaporator is 100.6 - 33.4 = 67.2 kPa.

Earle Fig. 4.1: Pressure measurements in pipes

Earle Fig. 4.1: Pressure measurements in pipes: (a) piezometer, (b) U-tube, (c) Pitot tube, (d) Pitot-static tube. Reproduced from Earle, Fig. 4.1, printed p. 39.

The most common pressure measuring instrument is the Bourdon tube pressure gauge. A coiled tube tends to straighten itself when subjected to internal pressure, and the degree of straightening is directly related to the difference between the pressure inside the tube and the pressure outside it. A bellows gauge works on a similar principle, with unknown pressure acting against a spring.

Velocity is measured with a Pitot tube, a tube bent so that its mouth faces directly into the flow. The pressure in the tube gives a measure of the velocity head. Combined with a piezometer tube across a common manometer, the differential head measures directly the velocity head of the flowing liquid. That arrangement is known as a Pitot-static tube and is extensively used in measuring flow velocities.

Worked example: air velocity in a duct (Earle Example 4.2)

Air at 0 °C is flowing through a duct in a chilling system. A Pitot-static tube is inserted and the differential pressure head measured is 0.8 mm of water. Calculate the velocity of the air. The density of air at 0 °C is 1.3 kg m⁻³. Converting the head into an equivalent head of air, 0.8 mm of water is 0.8 x 10⁻³ x (1000/1.3) = 0.62 m of air. From the velocity head relation, v²/2 = 0.62 x 9.81, so v = 3.5 m s⁻¹.

Earle Fig. 4.2: Venturi meter

Earle Fig. 4.2: Venturi meter. Reproduced from Earle, Fig. 4.2, printed p. 41.

Another method uses the pressure drop across a constriction. In a venturi meter, a gradual constriction reduces the area of flow from A₁ to A₂, the velocity rises and the static pressure falls in accordance with Bernoulli's equation. Joining the two sections to a U-tube manometer measures the differential head directly. In practice energy losses occur between the two measuring points, and a coefficient C is introduced to allow for this. In a properly designed venturi meter C lies between 0.95 and 1.0. An orifice meter works on the same principle, but instead of a tapered tube a plate with a hole in the centre is inserted in the pipe. The same equations hold, but the orifice discharge coefficient is smaller, and orifices have much greater pressure losses than venturi meters, although they are easier to construct and to insert in pipes. Other meters in use are propeller meters, impact meters and rotameters, in which a rotor disc is supported against gravity in a tapered vertical tube and rises to a height that depends on the flow velocity.

Quick check

A venturi meter and an orifice meter both measure flow from a pressure drop. Which one wastes more energy, and why would anyone choose it?

Check your answer

The orifice meter wastes more energy, because the sharp plate causes a larger permanent pressure loss. It is chosen because it is cheap and easy to fit into an existing pipe.

2.12 Pumps and fans: putting energy into the fluid

In pumps and fans, mechanical energy from some other source is converted into pressure or velocity energy in a fluid. The food technologist is not concerned with the details of pump design, but should know what classes of pump are used and something about their characteristics. The efficiency of a pump is the ratio of the energy supplied by the motor to the increase in velocity and pressure energy given to the fluid.

Positive displacement pumps draw the fluid in and then force it through the outlet. The types are reciprocating piston pumps; gear pumps, in which the fluid is enmeshed in rotating gears and forced through the pump; and rotary pumps, in which rotating vanes draw in and discharge fluid through a system of valves. Positive displacement pumps can develop high pressure heads, but they cannot tolerate throttling or blockages in the discharge.

Jet pumps produce a high velocity jet in a venturi nozzle, converting the energy of the fluid into velocity energy. That produces a low pressure area, causing the surrounding fluid to be drawn into the throat, and the combined fluids are then discharged. Jet pumps are used for difficult materials which cannot be handled satisfactorily in a mechanical pump, and as vacuum pumps. They have relatively low efficiencies but no moving parts and a low initial cost, and they can develop only low heads per stage.

Air-lift pumps introduce air or gas into a liquid to impart energy to it. Examples are air introduced to pump water from an artesian well, air introduced above a liquid in a pressure vessel to discharge it, vapours produced in the column of a climbing film evaporator, and air blown up through a bed of powder to convey it in fluidized form. Air-lift pumps and air blowing are inefficient, but they are convenient for materials which will not pass easily through the ports, valves and passages of other types of pumps.

Propeller pumps and fans impart energy with a propeller. They are used extensively to mix the contents of tanks and in pipelines to mix and convey the fluid. Propeller fans are common and have high efficiencies, but they can only be used for low heads, in the case of fans only a few centimetres of water.

Centrifugal pumps and fans convert rotational energy into velocity and pressure energy. The fluid is taken in at the centre of a bladed rotor and passes out along the spinning rotor, acquiring energy of rotation, which is then converted into velocity and pressure energy at the periphery of the disc. Centrifugal pumps can develop moderate heads of up to 20 m of water, and they can deliver very large quantities of fluids with high efficiency.

Gould adds the plant view. Pumps and pumping are one of the most important aspects of nearly all food processing operations, and some consider pumps the heart of many food operations. Pumps are classified into positive displacement pumps and centrifugal pumps, and each class is used in most food plants. All food contact surfaces of food pumps should be of 304 stainless steel or equivalent. One key feature to look for beyond maintenance is the Cleaned In Place feature: tearing down pumps to clean them is costly in manpower and costly in lost production time.

Ibarz sets out the pump quantities that matter for design. The total head a pump can develop is the difference between the discharge head and the suction head. The net positive suction head, NPSH, decides whether the pump cavitates. Cavitation is a phenomenon produced when the pressure at some point of the pump falls to the vapour pressure of the liquid, so that vapour bubbles form and then collapse. It causes a decrease of the suction and discharge pressures of the pump, which can empty it, and it damages the pump. To avoid cavitation, the available NPSH, which depends on the placement of the pump and the properties of the liquid, must be greater than the required NPSH, which is characteristic of each pump and is given by the manufacturer as a function of the pump design and its rotation speed. Cavitation appears when the pressure at the suction point falls below the vapour pressure. It can be avoided by increasing the pressure at the suction point, by lowering the height at which the pump is placed, or by decreasing the vapour pressure of the liquid, for example by cooling it. The pump power is the mass flow rate times the mechanical energy per unit mass supplied by the pump, and the real power is the theoretical power divided by the pump efficiency.

For a given centrifugal pump, the capacity varies with its rotational speed, the pressure developed varies as the square of the rotational speed, and the power required varies as the cube of the rotational speed. The same proportional relationships apply to centrifugal fans, and they are often called the fan laws.

Earle's Fig. 4.4 shows the characteristic curves for a centrifugal pump, reproduced with permission from Coulson and Richardson, Chemical Engineering, 2nd edition, fig. 6.15. The horizontal axis is capacity in m³ s⁻¹ from 0 to 0.030, and the vertical axis is total head in metres from 0 to 45. The chart carries three families of curves: impeller diameter curves from 90 mm to 150 mm, efficiency contours from 50% to 77%, and power curves from 1 kW to 8 kW, with an economical range marked at 57.5 Hz. The chart below is the book's own figure, with the same axes, the same impeller diameters, the same efficiency values and the same power values.

Figure 2.4: Characteristic curves for a centrifugal pump

Figure 2.4: Characteristic curves for a centrifugal pump. Axes, impeller diameters (90 to 150 mm), efficiency contours (50 to 77%) and power curves (1 to 8 kW) are as in the book. Reproduced from Earle, Fig. 4.4, p. 43, reproduced with permission from J. M. Coulson and J. F. Richardson, Chemical Engineering, 2nd edition, fig. 6.15.

To use the chart, find the duty point where the required capacity and the required head meet, then read off the impeller diameter that passes through that point, the efficiency contour that encloses it, and the power curve that passes through it. A pump running far from its economical range wastes power and wears faster. That is the practical meaning of the chart: match the pump to the duty, do not just buy a big one.

Brennan's Appendix I gives the same fluid flow formulae in compact form, including flow through equipment and fluidization, and it is the reference to reach for when a quick formula is needed without working through a chapter.

Try it yourself: Take a garden hose and a bucket. Time how long it takes to fill the bucket with the tap half open, then fully open. Measure the hose diameter. Work out the velocity and the Reynolds number for water at about 20 °C, with a viscosity of 1 x 10⁻³ Pa s and a density of 1000 kg m⁻³. Then kink the hose part way: the flow drops far more than the kink looks worth. That is a fitting loss, and you have just measured it with a bucket and a watch.

Key ideas to carry forward

  • A fluid in food engineering covers liquids, gases and fluidized solids, because they obey many of the same laws.
  • Pressure in a still liquid is P = Zρg: it depends only on depth and density, not on the shape of the vessel.
  • The continuity equation A₁v₁ = A₂v₂ says volume flow is the same at every section of a pipe, so velocity rises where the pipe narrows.
  • Bernoulli's equation Zg + v²/2 + P/ρ = k is the energy balance for flow, and it can be written as energies, as pressures, or as heads.
  • Viscosity is the resistance to relative movement of adjacent layers, given by F/A = μv/Z. Water is about 1 x 10⁻³ N s m⁻², olive oil about 100 x 10⁻³, and molasses about 7.
  • Newtonian fluids obey τ = μ(dv/dZ). Non-Newtonian fluids follow the power law: pseudoplastic fluids such as tomato purée thin with shear, dilatant fluids such as gritty slurries thicken with shear, and some fluids need a yield stress before they flow at all.
  • The Reynolds number Re = Dvρ/μ decides the flow regime: below 2100 streamline, between 2100 and 4000 transition, above 4000 turbulent in Earle, with Ibarz taking fully turbulent flow above 10,000.
  • Friction loss in a straight pipe follows the Fanning equation ΔP_f = (4fρv²/2)(L/D). In streamline flow f = 16/(Re). In turbulent flow f comes from the Moody diagram, as a function of Re and the roughness ratio ε/D.
  • Earle's friction factor f and Ibarz's 4f differ by a factor of four: the Darcy factor is 4f. Always check which definition a chart or a table uses.
  • Fitting losses are kv²/2, or the equivalent length of straight pipe. A globe valve costs far more than a gate valve, and a half closed gate valve costs far more than either.
  • Pressure is measured with piezometer tubes, U-tubes and Bourdon gauges. Flow is measured with Pitot-static tubes, venturi meters, orifice meters and rotameters.
  • Pumps divide into positive displacement, jet, air-lift, propeller and centrifugal types. A centrifugal pump is chosen from its characteristic curves, matching capacity, head, efficiency and power to the duty.
  • Cavitation happens when the pressure at the pump suction falls to the vapour pressure of the liquid. The available NPSH must be greater than the required NPSH.

Glossary

Fluid

A substance that flows, including liquids, gases and fluidized solids. Food tech example: milk, fruit juice, syrup, air and flour all count as fluids in a food factory.

Fluid statics

The study of fluids at rest, including the pressure a still liquid exerts. Food tech example: the pressure at the bottom of a storage tank, which depends only on the depth of liquid.

Fluid dynamics

The study of fluids in motion. Food tech example: milk flowing through a pasteurizer pipe.

Pressure head

A pressure expressed as the height of a column of a given fluid that would produce it. Food tech example: atmospheric pressure is about 10.2 m of water.

Gauge pressure

Pressure measured above atmospheric pressure as the datum. Food tech example: a retort gauge reading 100 kPa means 100 kPa above the air outside.

Continuity equation

The mass balance for flow in a pipe: for an incompressible fluid, A₁v₁ = A₂v₂, so the volume flow is the same at every section. Food tech example: milk speeding up as it passes from a wide pipe into a narrow one.

Bernoulli's equation

The energy balance for frictionless flow: Zg + v²/2 + P/ρ is constant along the flow. Food tech example: the pressure falling in a pipe where it narrows and the velocity rises.

Velocity head

The kinetic energy term of Bernoulli's equation written as a height, v²/2g. Food tech example: the head a Pitot tube measures to find the velocity of air in a duct.

Viscosity

The property of a fluid that resists the relative movement of adjacent layers, measured in N s m⁻². Food tech example: honey at about 7 N s m⁻² pouring far more slowly than water at about 1 x 10⁻³ N s m⁻².

Newtonian fluid

A fluid that obeys Newton's law of viscosity, with a constant viscosity whatever the shear rate. Food tech example: water, milk and fruit juice.

Non-Newtonian fluid

A fluid whose apparent viscosity changes with the shear rate. Food tech example: tomato purée, which flows more easily the harder it is stirred.

Pseudoplastic

A non-Newtonian fluid whose apparent viscosity falls as the shear rate rises. Food tech example: tomato purée.

Dilatant

A non-Newtonian fluid whose apparent viscosity rises as the shear rate rises. Food tech example: a gritty slurry of crystallized sugar solution.

Yield stress

The minimum shear stress that must be applied before a fluid starts to flow. Food tech example: a thick paste that stays put in a pipe until the pump pressure passes a threshold.

Reynolds number

The dimensionless ratio of inertial to viscous forces in a flowing fluid, Re = Dvρ/μ. Food tech example: milk in a pipe at Re = 50,230, which is turbulent flow.

Streamline flow

Smooth flow in parallel layers with no mixing across the flow, also called laminar flow. Food tech example: olive oil flowing slowly in a pipe at Re = 460.

Turbulent flow

Flow with eddies and mixing across the direction of flow. Food tech example: milk flowing fast in a pipe at Re = 50,230.

Friction factor

The coefficient f that relates the wall friction in a pipe to the velocity pressure of the fluid. Food tech example: f = 16/(Re) in streamline flow, read from the Moody diagram in turbulent flow.

Moody diagram

A log-log chart giving the friction factor as a function of Reynolds number and pipe roughness. Food tech example: finding f for olive oil in a steel pipe from Re and the roughness ratio.

Roughness ratio

The ratio of the average height of the roughness on a pipe wall to the pipe diameter, ε/D. Food tech example: commercial steel at ε = 0.00005 m, which is smooth beside riveted steel at up to 0.01 m.

Equivalent length

A length of straight pipe that would give the same friction loss as a fitting. Food tech example: a fully open gate valve equal to 7 pipe diameters, and the same valve a quarter open equal to 900.

Pitot tube

A tube facing into a flow that measures the velocity head. Food tech example: measuring the velocity of air in a chilling duct as 3.5 m s⁻¹.

Venturi meter

A flow meter that measures the pressure drop across a gradual constriction in a pipe. Food tech example: measuring milk flow without a moving part in the pipe.

Positive displacement pump

A pump that draws fluid in and forces it out through the outlet, such as a piston, gear or rotary pump. Food tech example: a gear pump moving thick jam that a centrifugal pump could not handle.

Centrifugal pump

A pump that converts rotational energy into velocity and pressure energy with a spinning bladed rotor. Food tech example: the standard pump for moving milk and water around a factory.

Cavitation

The formation and collapse of vapour bubbles when the pressure in a pump falls to the vapour pressure of the liquid. Food tech example: a pump that loses suction and rattles because it is placed too high above the supply tank.

NPSH

Net positive suction head, the head available at a pump suction above the vapour pressure of the liquid. Food tech example: the available NPSH must be greater than the required NPSH given by the pump maker, or the pump will cavitate.

References

  • Earle, R. L., Unit Operations in Food Processing, 2nd edition, Pergamon Press, 1983. Chapter 3, Fluid-Flow Theory, including Examples 3.1 to 3.10, Figures 3.1 to 3.8 and Tables 3.1 to 3.3, and Chapter 4, Fluid-Flow Applications, including Examples 4.1 to 4.3 and Figures 4.1 to 4.4.
  • Ibarz, Albert, and Barbosa-Canovas, Gustavo V., Unit Operations in Food Engineering, CRC Press, 2003. Chapter 3, Introduction to Transport Phenomena, including Figures 3.1 and 3.2; Chapter 4, Molecular Transport of Momentum, Energy, and Mass, including Newton's law of viscosity, Fourier's law and Fick's law; and Chapter 7, Transport of Fluids through Pipes, including Figures 7.13 and 7.14 and Tables 7.1, 7.2 and 7.3.
  • Brennan, J. G., Butters, J. R., Cowell, N. D., and Lilly, A. E. V., Food Engineering Operations, Elsevier, 1969. Appendix I, Fluid Flow Formulae.
  • Gould, Wilbur A., Unit Operations for the Food Industries, CTI Publications, 1996. Chapter 11, Pumps and Pumping.
  • Moody, L. F. (1944), as reproduced in Earle, Fig. 3.8, and in Ibarz, Fig. 7.14.
  • Coulson, J. M., and Richardson, J. F., Chemical Engineering, 2nd edition, as reproduced in Earle, Fig. 4.4.