Unit 6: Drying and Dehydration

Note

A bunch of grapes left in the sun turns into raisins. The grapes lose most of their water, shrink to a fraction of their weight, and keep for months without a fridge, while the fresh grapes would spoil in days. Nothing was added and nothing was cooked: water simply left, carried away by warm dry air. That is drying, the oldest preservation method there is, and it is also one of the most exacting pieces of engineering in a food factory, because the same hot air that removes water can scorch flavour, brown colour and harden the surface so the inside never dries at all. This unit follows the water out of the food, step by step.

Questions to think about

  • Why does removing water preserve food, and how dry is dry enough?
  • What is the difference between water a food holds loosely and water it holds tightly?
  • Why does a wet surface dry at a steady rate, and then suddenly slow down?
  • How do you read a psychrometric chart, and what does it tell you about the air in a dryer?
  • How much heat does it take to dry a kilogram of food, and where does that heat go?
  • Why does freeze dried coffee keep its aroma when hot air dried coffee does not?

6.1 Why dry food

Drying is one of the unit operations most commonly used for food preservation, and Ibarz notes that it has been used since prehistoric times because it gives foods longer lives. As populations grew, the demand for dried foods grew with them, and the drying industry grew in step, with military needs for light, long keeping rations driving many of the advances. The reasons are still the same today. Taking water out of a food slows microbes and slows the chemical reactions that spoil it. It also cuts weight and, in some cases, volume, which cuts the cost of packaging, handling, storage and transport. A sack of dried milk powder ships for a fraction of the cost of the same milk as liquid, and it needs no refrigeration on the way.

The books draw a line between two words that are often used as if they meant the same thing. Drying and dehydration are not synonyms. A food is considered dehydrated if it does not contain more than 2.5% water, while a dried food may contain more than 2.5% water. That 2.5% line matters because the last few percent of water are the hardest to remove and the most important for keeping quality: they are the water that microbes and browning reactions need.

Except for freeze drying, osmotic drying and vacuum drying, water is removed in most cases by blowing a flow of dry air over the food, which carries water from the surface of the product into the air stream. Drying does more than remove water, and the books are honest about the cost: it can destroy nutrients and set off enzymatic and nonenzymatic reactions, change colour and flavour, and harden texture. The engineering of drying is the art of removing the water fast enough to be economical, gently enough to keep the food worth eating, and evenly enough that no part is over dried while another part stays wet.

Quick check

What is the difference between a dried food and a dehydrated food in the book's definition?

Check your answer

A dehydrated food contains no more than 2.5% water. A dried food may contain more than 2.5% water.

6.2 The water inside a food: free, bound and in equilibrium

Not all the water in a food behaves the same way. Some of it is held loosely, almost as if it were free water in a dish, and it leaves easily. Some of it is held tightly by the food itself, and it leaves only with difficulty. The books describe the range of holding strengths rather than two neat boxes: water is held by forces that run from the very weak forces retaining surface moisture to very strong chemical bonds. The loosely held part can, for drying purposes, be treated as free water at the surface. The tightly held part is bound water, and as drying goes on the remaining water is bound more and more strongly, so the drying rate falls.

A hygroscopic material is one that contains bound water which exerts a vapour pressure lower than the vapour pressure of liquid water at the same temperature. Foods made mainly of carbohydrates behave this way, because the hydroxyl groups around the sugar molecules form hydrogen bonds with water molecules. In water soluble proteins, the polar amino acids sit on the outside of the molecule and the water hating groups sit inside, which lets the protein form hydrogen bonds with water and explains why such proteins dissolve. Fats and crystalline salts and sugars absorb almost no water when the relative humidity is low or moderate, while sugars in the amorphous form absorb more than in the crystalline form.

The key working idea is the equilibrium moisture content. Under a given vapour pressure of water in the surrounding air, a food settles at a moisture content in equilibrium with its surroundings, and it cannot be dried below that content by air at those conditions, however long it stays in the dryer. Earle's Fig. 7.4 plots equilibrium moisture against the relative humidity of the air for several foods, and the curves are S shaped. For potato at 20°C in air at 30% relative humidity, giving a water activity of 0.3, the equilibrium moisture content is 0.1 kg water per kg dry potato. It would not be possible to dry potatoes below 10% using an air dryer with air at 20°C and 30% relative humidity. Above about 80% relative humidity the equilibrium content of potato rises very rapidly. The curves differ between foods in shape and in amount, most strongly between 0 and 65% relative humidity, and the S shape is most pronounced, with the highest moisture at low humidities, for foods whose dry solids are high in protein, starch or other high molecular weight polymers.

Water moves inside the food by several mechanisms: capillary forces, diffusion of liquid down a concentration gradient, surface diffusion, diffusion of water vapour in pores filled with air, flow down a pressure gradient, and flow by vaporization and condensation of water. In the pores of rigid solids, capillary forces hold the water. In solids made of fine powder aggregates, osmotic pressure holds it. The drying rate at any moment depends on which of these mechanisms is slowest, and that changes as the food dries.

Practical note: the equilibrium moisture content is the floor of the whole operation. A dryer specification that asks for a final moisture below the equilibrium value for the drying air is not ambitious, it is impossible. The first check on any drying duty is to read the equilibrium moisture from the curve for the food at the temperature and humidity of the drying air.

6.3 The air side: psychrometry

Drying with hot air is a partnership between the food and the air, and the air must be understood first. Psychrometry is the study of air-water mixtures, and Ibarz Chapter 5 gives the working definitions, all referred to one kilogram of dry air.

Absolute humidity X is the mass of water per mass of dry air, in kg water per kg dry air. From the partial pressure of water vapour pᵥ and the total pressure P, X = 0.622 pᵥ/(P - pᵥ) (5.3), using the molecular weights of water, 18 kg/kmol, and air, 28.9 kg/kmol. When the air is saturated, pᵥ equals the saturation pressure pₛ, and X_saturation = 0.622 pₛ/(P - pₛ) (5.4).

Relative humidity φ is the ratio of the water vapour pressure in the air to the saturation pressure at the same temperature: φ = pᵥ/pₛ (5.5). Saturated air has φ = 1. The two humidities are linked by X = 0.622 φpₛ/(P - φpₛ) (5.6).

Percentage humidity is the ratio of the absolute humidity to the saturation humidity, X/X_saturation. Humid volume is the volume occupied by 1 kg of dry air plus the water vapour it contains, from the ideal gas law. Humid specific heat ŝ is the heat needed to raise 1 kg of dry air plus its water by 1°C: ŝ = ĉ_air + Xĉ_v (5.12), and with the mean values ĉ_air = 1 kJ/kg·°C and ĉ_v = 1.92 kJ/kg·°C, ŝ = 1 + 1.92X kJ per kg dry air per °C (5.13).

Humid enthalpy îɢ is the enthalpy of the dry air plus the enthalpy of its water vapour, referred to liquid water at 0°C and 1 atm. With λ₀ = 2,490 kJ/kg, the latent heat of vaporization of water at 0°C, îɢ = ŝT + λ₀X (5.16). The latent heat of vaporization itself falls as temperature rises, which is why the book gives the Regnault approximation λ = 2,538 - 2.91T kJ/kg, with T in °C.

Three temperatures describe the air, and they are easy to confuse, so the book defines each one. The dew temperature Tʀ is the temperature at which the air becomes saturated when it is cooled: the temperature at which condensation begins. The adiabatic saturation temperature Tₛ is the temperature at which air is saturated when it is cooled adiabatically. The humid temperature Tʜ, also called the wet bulb temperature, is the temperature reached by a small mass of water under adiabatic and steady conditions, exposed to an air stream of constant temperature, moisture and velocity. In the air-water system, for air velocities between 4 and 10 m/s, the humid temperature coincides with the saturation temperature. A wet bulb thermometer is a thermometer with its bulb wrapped in a wet wick and air blown past it: evaporation cools the bulb to the wet bulb temperature, and the difference between the dry bulb and the wet bulb, the wet bulb depression, tells the humidity.

The psychrometric chart puts all of this on one page. Ibarz presents the Mollier diagram in the form ŝT against X, with the product of humid specific heat and temperature on the vertical axis and absolute humidity on the horizontal axis. Isothermic lines are straight lines with slope 1.92T and intercept T, from ŝT = T + 1.92TX (5.17). The saturation curve φ = 1 bounds the chart: no point can sit beyond it, because air cannot hold more water than saturation at that temperature.

Figure 6.1: Psychrometric chart, humid temperature product

Figure 6.1: Psychrometric chart, ŝT against X. The product of humid specific heat and temperature is plotted against absolute humidity X. The curves are lines of constant relative humidity φ, with φ = 1 the saturation curve. The diagonal line is the isoenthalpic line îₗ. The points X and Xₛ mark the humidity and the saturation humidity, and T, Tₕ and Tₙ mark the dry bulb, humid (wet bulb) and dew temperatures. (Ibarz, Fig. 5.2, p. 70)

Heating air at constant humidity moves its point horizontally on the temperature-humidity chart: no water is added or removed, so the humidity stays the same while the temperature rises and the relative humidity falls. That is why heating is the first step in a dryer: hot air at low relative humidity has room to take up water. Cooling air at constant humidity moves the point horizontally the other way until it reaches the saturation curve at the dew point; further cooling follows the saturation line down, with water condensing out. Adiabatic saturation, the path air follows as it dries a wet solid with no outside heat, follows a line of constant wet bulb temperature: the air cools as it gives up heat to evaporate water, and its humidity rises by the same step.

Earle's worked examples in this section are all chart readings, and they show how much a chart can do. In Example 7.7, a wet bulb temperature of 20°C in air at a dry bulb temperature of 25°C, a wet bulb depression of 5°C, gives a relative humidity of about 64%, an enthalpy of 57 kJ kg⁻¹ and a specific volume of 0.862 m³ kg⁻¹. In Example 7.8, that same air heated to a dry bulb temperature of 40°C, at constant humidity, has an enthalpy of 73 kJ kg⁻¹, a specific volume of 0.906 m³ kg⁻¹ and a relative humidity of 27%. For a flow of 1,000 m³ h⁻¹, the mass is 1,000/0.906 = 1,104 kg, the enthalpy rise is 73 - 57 = 16 kJ kg⁻¹, and the heat needed is 1,104 x 16 kJ h⁻¹, which is 5 kW. Heating the air dropped its relative humidity from 64% to 27% without adding or removing a gram of water: that fall is the drying power the heater buys.

Quick check

Air at 25°C dry bulb and 20°C wet bulb is heated to 40°C with no water added or removed. What happens to its relative humidity, and why?

Check your answer

It falls, from about 64% to 27%. Heating at constant absolute humidity raises the saturation pressure, so the same amount of water vapour is a smaller fraction of what the air could hold.

Try it yourself: read the air in your kitchen

Take the temperature in a room with an ordinary thermometer, then wrap the bulb in a wet cloth, fan air past it with a piece of card, and read the lowest temperature it reaches. The difference between the two readings is the wet bulb depression. A big difference means dry air that would dry food quickly; a small difference means humid air that would dry food slowly. If you have a hygrometer, compare its reading with the relative humidity you estimate from the two temperatures. You have just used a psychrometer, the same instrument the books use to measure drying air.

6.4 The drying curve: steady, then slowing

Drying data are usually taken as the weight of the product against time, and from that curve the drying rate is found. The moisture content is defined on a dry basis: Y_t = (w_T - w_S)/w_S (17.9), where w_T is the total weight at a given time and w_S is the weight of dry solids. The free moisture content is Y = Y_t - Y_eq (17.10), the moisture above the equilibrium value. The drying rate R is proportional to the change of moisture with time, R ∝ dY/dt, and in full R = -(w'_S/A)(dY/dt) (17.12), where w'_S is the flow of dry solids and A is the drying surface area.

Plotted against free moisture, the drying rate gives the curve that governs the whole subject.

Figure 6.2: Drying rate curve

Figure 6.2: Drying rate curve. Drying rate R in kg water per h per m² against free moisture Y in kg water per kg dried solids. Points A and A' are the starting points for a cold and a hot material, B is the point where the surface reaches its equilibrium temperature, B to C is the constant rate period, C is the critical moisture Yₕ where the falling rate period begins, D is the point where the surface is completely dry, and E is the end of drying. (Ibarz, Fig. 17.6, p. 579)

The curve reads from right to left, because moisture falls as drying goes on. Points A and A' are the starting points for a cold and a hot material. Point B is where the surface reaches its equilibrium temperature, and the short time from A or A' to B is usually small and commonly neglected in drying time calculations. From B to C the rate is constant: this is the constant rate period, when unbound water is being removed. The surface stays wet, the water activity at the surface stays close to one, and water moves from the interior fast enough to replace what evaporates. In porous solids the water removed from the surface is made up by flow from inside. The surface temperature sits close to the wet bulb temperature, and the water behaves as if the solid were not there.

At point C the rate can no longer be held constant, and the falling rate period begins. The critical moisture content Yc is the moisture at C. The water activity at the surface falls below one, and the rate is now governed by the movement of water and water vapour inside the solid. The first stage of the falling rate period runs from C to D, while wet patches on the surface shrink until the surface is completely dry at D. The second stage runs from D to E, with the surface dry and the evaporation plane moving into the interior of the solid. Heat must travel through the solid to the evaporation plane, and the vapour produced must travel back out through the solid to the surface. Sometimes the two falling rate stages are not clearly distinct. The amount of water removed in the falling rate period may be small, but the time it takes may be long, because the rate is low.

Brennan draws the same story in three plots together, and the three views make the shape easier to remember.

Figure 6.3: Drying curves for a wet solid in heated air

Figure 6.3: Drying curves for a wet solid in heated air at constant temperature and humidity. Top: moisture W against time t. Middle: drying rate dW/dt against time t, showing the constant rate plateau from B to C. Bottom: drying rate dW/dt against moisture W, showing the constant rate plateau from C to B and the critical moisture Wₕ. The critical time tₕ is marked on the first two plots. (Brennan, Fig. 12.2, p. 247)

Earle adds two facts that every food dryer must respect. First, the change from constant rate to falling rate happens at different moisture contents for different foods, but for many foods it happens when the moisture is in equilibrium with air of 58 to 65% relative humidity, that is at a water activity a_w of 0.58 to 0.65. That moisture is the critical moisture content Xc. Second, many foods, such as potato, do not show a true constant rate period at all: they show a slowly and steadily declining rate with a sharp break, and the constant rate idea is still a useful approximation.

The generalized drying curve makes the same point without any particular food in mind. Earle's Fig. 7.7 plots the relative drying rate, the rate divided by the constant rate, against the relative moisture content, X/Xc.

Figure 6.4: Generalized drying curve

Figure 6.4: Generalized drying curve. Relative drying rate against relative moisture content X/Xₕ. At the critical moisture, X/Xₕ = 1.0, the relative rate is 1.0; below the critical moisture the rate falls away, at first slowly and then steeply. (Earle, Fig. 7.7, p. 96)

At the critical moisture the relative rate is 1.0, and below it the rate falls away in a curve that is the same shape for many foods once it is scaled this way. That is why the critical moisture is worth finding for each food: it divides the drying into the part the air controls and the part the food controls.

The constant rate period, in equations

During the constant rate period the surface stays saturated with water, and only two transfers matter: heat from the hot air to the surface, and mass from the surface to the hot air. With convection only, q = hA(T - T_w) (17.13), where h is the heat transfer coefficient, A the area, T the air temperature and T_w the wet bulb temperature. The mass flux is Nₐ = k_y(X_w - X) (17.14), where X_w is the humidity of air at the surface and X is the humidity of the air stream. The heat that evaporates the water is q = NₐMₐλ_wA (17.15), with Mₐ the molecular weight of water and λ_w the latent heat of vaporization at T_w. Putting them together gives the constant drying rate two ways:

R_c = k_yM_b(X_w - X) (17.16) and R_c = h(T - T_w)/λ_w (17.17)

where M_b is the molecular weight of air. The two must agree, because the heat arriving and the water leaving are the same event seen from two sides. If there is no conduction or radiation, the temperature of the solid during the constant rate period is the wet bulb temperature. Brennan gives the same result in the form [dw/dt]_c = -K_gA(p_s - p_a) (12.1), where p_s is the vapour pressure at the surface and p_a is the vapour pressure in the air: the driving force is the vapour pressure difference between the drying surface and the main stream of the drying air.

The falling rate period, and diffusion

Once the moisture falls below the critical value, the rate is set by the movement of water inside the solid, and Fick's law returns in its time dependent form:

∂Y/∂t = D_eff ∂²Y/∂x² (17.23)

where Y is the moisture content, t is time, x is the distance in the direction of transfer, and D_eff is the effective diffusion coefficient. The book gives the solutions for a slab, a cylinder and a sphere. For a slab the moisture ratio is a sum of exponentials in D_eff t/L², where L is the thickness; for a sphere it is a sum in D_eff t/r², where r is the radius. The effective diffusivity is found experimentally from drying data: plotting ln Γ against time, where Γ is the moisture ratio (Y - Y_s)/(Y₀ - Y_s), the slope of the straight section gives D_eff. Table 6.1 gives the book's values, which span three orders of magnitude: water moves far more easily through some foods than others, and that is why drying times differ so much between foods.

Table 6.1: Effective diffusivity of some food products (Ibarz Table 17.1)

FoodTemperature (°C)Effective diffusivity D_eff (m²/s)
Whole milk, foam502.0 x 10⁻⁹
Whole milk, foam401.4 x 10⁻⁹
Whole milk, foam358.5 x 10⁻¹⁰
Apples666.40 x 10⁻⁹
Freeze-dried apples252.43 x 10⁻¹⁰
Raisins254.17 x 10⁻¹¹
Potatoes542.58 x 10⁻¹¹
Potatoes603.94 x 10⁻¹¹
Potatoes65.54.37 x 10⁻¹¹
Potatoes68.86.36 x 10⁻¹¹
Pears (slabs)669.63 x 10⁻¹⁰
Veal, freeze-dried powder253.07 x 10⁻¹¹
Carrot cubes406.75 x 10⁻¹¹
Carrot cubes6012.1 x 10⁻¹¹
Carrot cubes8017.9 x 10⁻¹¹
Carrot cubes10024.1 x 10⁻¹¹

Table 6.1: Effective diffusivity of some food products. Source: Okos et al., in Heldman and Lund, Handbook of Food Engineering, 1992, as cited in Ibarz, Table 17.1, p. 585.

Two patterns stand out. Diffusivity rises with temperature: carrot cubes go from 6.75 x 10⁻¹¹ m²/s at 40°C to 24.1 x 10⁻¹¹ m²/s at 100°C, nearly four times faster. And it varies hugely between foods: apples at 66°C, 6.40 x 10⁻⁹ m²/s, let water move about 250 times faster than potatoes at 54°C, 2.58 x 10⁻¹¹ m²/s. A dryer sized for apples will not dry potatoes in anything like the same time.

Quick check

Why does the drying rate fall in the falling rate period, even though the air is just as hot and dry as before?

Check your answer

Because the surface is no longer wet: the rate is now set by how fast water can move through the inside of the solid to the surface, by diffusion, and that internal movement is slow.

6.5 How much heat does drying take

Most of the heat in drying goes to evaporating water, and the latent heat of vaporization is the biggest number in the whole calculation. Earle's Table 7.1 gives it at pressures from 1 kPa up to 500 kPa, and the pattern is simple: the lower the pressure, the higher the latent heat and the lower the boiling temperature.

Table 6.2: Latent heat of water at various pressures and saturation temperatures (Earle Table 7.1)

Pressure (kPa)Saturation temperature (°C)Latent heat (kJ/kg)
172485
2182460
5332424
10462393
20602358
50812305
10099.62258
101.35 (1 atm)1002257
1101022244
1201052238
2001202202
5001522109

Worked example 6.1: drying a food at atmospheric pressure (Earle Example 7.1)

A food with 80% water is dried to 10% moisture. The initial temperature is 21°C, the latent heat at 100°C is 2,257 kJ kg⁻¹, the specific heat of the food is 3.8 kJ kg⁻¹ °C⁻¹ and of water is 4.186 kJ kg⁻¹ °C⁻¹.

Per kg of raw material, the solids are 0.20 kg. At 10% moisture the final mass is 0.20/0.90 = 0.222 kg, so the water lost is 1 - 0.222 = 0.778 kg per kg of raw material. The heat needed is the sensible heat to warm the food to 100°C plus the latent heat to evaporate the water:

Heat = (100 - 21) x 3.8 + 0.778 x 2,257 = 300.2 + 1,755.9 = 2,056 kJ per kg of raw material.

Per kg of water removed, that is 2,056/0.778 = 2,643 kJ kg⁻¹. The sensible heat is only about 15% of the total: evaporation dominates, as it always does in drying.

Example 7.1: Drying at atmospheric pressure: mass and heat

Diagram for Worked example 6.1 (Earle Example 7.1): mass and heat balance on 1 kg of raw food. The food is 80% water; drying to 10% moisture removes 0.778 kg of water, leaving 0.222 kg of dried food. Heat: 2,056 kJ per kg of raw food, 2,643 kJ per kg of water removed. Drawn from the book's numbers.

Worked example 6.2: vacuum drying (Earle Example 7.2)

The same food dried at 60°C in a vacuum of 81.4 kPa, giving an absolute pressure of 20 kPa. At 60°C the latent heat is 2,358 kJ kg⁻¹ from Table 6.2.

Heat = (60 - 21) x 3.8 + 0.778 x 2,358 = 148.2 + 1,834.5 = 1,983 kJ per kg of raw material.

The total is slightly less than at atmospheric pressure, and the food never gets hotter than 60°C, which is kinder to flavour and nutrients. The trade is the cost of the vacuum equipment and the larger latent heat at low pressure, which partly offsets the saving in sensible heat.

Example 7.2: Vacuum drying: mass and heat balance

Diagram for Worked example 6.2 (Earle Example 7.2): the same balance at 60 °C under vacuum (81.4 kPa vacuum, 20 kPa absolute). The latent heat at 60 °C is 2,358 kJ kg⁻¹, and the heat needed is 1,983 kJ per kg of raw food. Drawn from the book's numbers.

Worked example 6.3: freeze drying (Earle Example 7.3)

The same food freeze dried at 0°C. The latent heat of sublimation of ice is 2,838 kJ kg⁻¹, higher than the latent heat of evaporation.

Heat = 0.778 x 2,838 = 2,208 kJ per kg of raw material.

Freeze drying takes more heat per kg of raw material than either of the other two, and it also needs refrigeration and vacuum, so it is the most expensive way to dry. It earns its place because the product never melts, never collapses, and keeps its shape, colour and aroma: the water leaves as vapour from the solid ice, so the structure stays open and porous.

Example 7.3: Freeze drying: mass and heat balance

Diagram for Worked example 6.3 (Earle Example 7.3): the same balance for freeze drying at 0 °C. The water leaves as vapour from solid ice, so the heat is the latent heat of sublimation alone, 2,208 kJ per kg of raw food. Drawn from the book's numbers.

Quick check

A food is dried from 80% water to 10% moisture. Why is the heat needed per kg of water removed, 2,643 kJ/kg, higher than the latent heat of vaporization alone, 2,257 kJ/kg?

Check your answer

Because the food must first be warmed from 21°C to the drying temperature, and that sensible heat adds to the latent heat of evaporation.

6.6 How long will it take

Drying time is found in two parts: the constant rate time and the falling rate time, added together.

The constant rate time, from moisture Y₁ to the critical moisture Yc, is t_c = (w_S/R_cA)(Y₁ - Yc) (17.32), where w_S is the dry solids, R_c the constant drying rate, and A the area. It is simply the water to be removed divided by the rate at which water leaves.

The falling rate time depends on which model describes the food. For a slab of half thickness L, the first falling rate stage time is t_D = -(L²/D_eff)(π²/4) ln[(Y₂ - Y_s)/(Y₁ - Y_s)] in the form of Eq. 17.35, and for the second falling rate stage, where the evaporation plane has moved inside, t_D = (L²/D_eff) ln[(Y₁ - Y_s)/(Y₂ - Y_s)] in the form of Eq. 17.36, where Y_s is the surface moisture. The total drying time is t_S = t_C + t_D.

For a bed dryer, where air flows through a bed of solids, the books give the heat and mass balances that set the drying time and the air requirement: the water removed equals the change in the air's humidity times the air flow, and the heat supplied equals the change in the air's enthalpy times the air flow, with the heat used to evaporate water and to warm the solids. For a continuous countercurrent dryer the same balances apply stage by stage, with the solids entering wet and leaving dry while the air enters dry and leaves wet, and the books give the equations for the moisture and temperature profiles along the dryer (Eqs. 17.52 to 17.56). In all of these, the same two quantities govern the answer: how much water must leave, and how much heat the air can carry to the food and carry away as vapour.

Practical note: the constant rate period is usually the fast part and the falling rate period the slow part. A dryer sized only on the constant rate will be too small. Always size on the total time, and remember that the falling rate time grows with the square of the thickness: halving the slice thickness cuts the diffusion time to a quarter.

6.7 The dryers

A dryer has three parts: a feeder that presents the food to the drying air, a heater that warms the air, and a collector that catches the dried product and, where needed, the dust. The heater may heat the air directly, with the hot combustion gases mixing with the air, at temperatures up to 648 to 760°C, or indirectly, with a heat exchanger, at temperatures up to 425°C. The collector may be a cyclone, a bag filter or a wet washer. The choice of dryer depends on the form of the food: liquid, paste, pieces, or powder, and on how delicate it is.

Chamber and bed dryers

In a chamber dryer, the food sits on trays in a chamber and hot air is blown over it. In a bed dryer, air flows through a bed of pieces. Both are batch or semi continuous, and both are used for pieces of fruit, vegetables and meat, and for foods that cannot be pumped. The books give the balances for a bed dryer in Eqs. 17.43 to 17.48, linking the air flow, the humidity rise, the heat supplied and the water removed.

Spray drying

Spray drying turns a liquid into a powder in seconds. The liquid is atomized into fine droplets, sprayed into a stream of hot air, and the droplets dry as they fall, before they can hit a wall and stick. It was first used around 1900 for dry milk, and later for eggs and coffee. The droplet size sets the drying time and the powder size, and it is controlled by the atomizer. For a pressure nozzle, the droplet size falls as the pressure rises and as the feed rate falls, and it rises with the viscosity and surface tension of the feed (Table 17.2). For a rotary atomizer, a spinning disk throws the liquid off its edge, and the droplet size depends on the disk speed, the feed rate, the viscosity, the surface tension and the density, with the disk speed the strongest influence, an exponent of 0.55 to 0.80 (Table 17.3).

Table 6.3: Droplet size against process variables for a pressure nozzle (Ibarz Table 17.2)

VariableEffect on droplet size
PressureDroplet size decreases as pressure increases
Feed rateDroplet size increases as feed rate increases
ViscosityDroplet size increases as viscosity increases
Surface tensionDroplet size increases as surface tension increases

The rotary atomizer is sized by Eq. 17.73, with constants that depend on the disk speed and the blade load, in kg per h per m of disk edge. Table 6.4 gives them.

Table 6.4: Constants for Eq. 17.73, rotary atomizer (Ibarz Table 17.4)

Disk speed (m/s)Blade load (kg/h·m)abdK x 10⁴
85-1152500.240.820.241.4
85-180250-15000.20.80.21.6
180-3001000-30000.120.770.121.25
85-1403000-600000.120.80.121.2

Table 6.4: Constants for the rotary atomizer droplet size equation. Source: Masters, Spray Drying Handbook, 1991, as cited in Ibarz, Table 17.4, p. 590.

Pneumatic atomizers use a high velocity air stream to break the liquid into droplets. The book notes that the ratio of air to liquid mass flow, w_air/w_liq, below 0.1 gives deteriorating atomization, and 10 is the upper limit (Table 17.5).

Freeze drying

Freeze drying has two stages. First the food is frozen. Then the pressure is dropped below the triple point of water, 627 Pa at 0°C, and heat is supplied so the ice sublimes directly to vapour, without melting. Because the water never becomes liquid, the structure does not collapse: the dried product keeps its shape, and the pores left by the ice make it rehydrate fast. The product is typically 10 to 15% of its original weight, with moisture below 2%, and it needs no refrigeration in storage. The process was developed in the 1940s for drying plasma and blood, and it is now used for coffee, fruits, vegetables and meats where quality justifies the cost.

During the second stage, secondary drying, the product must be kept below 30 to 50°C to prevent collapse of the dried structure. The rate depends on the thermal conductivity of the dried layer and on the sublimation temperature of the product, both given in Table 6.5.

Table 6.5: Thermal conductivity and sublimation temperature for freeze drying (Ibarz Table 17.6)

ProductThermal conductivity k (W/m·K)Sublimation temperature T_sub (°C)
Coffee extract 25%0.033-23
Gelatin0.016-
Milk0.022-
Apple0.016-0.035-7
Peach0.016-
Turkey0.014-
Mushrooms0.010-
Veal0.035-0.038-14
Shrimp--18
Whole egg--17
Chicken--21
Salmon--29
Carrot--25

Table 6.5: Thermal conductivity of the dried layer and sublimation temperature for some foods. Source: Schwartzberg, 1982, as cited in Ibarz, Table 17.6, p. 595. A dash means the book gives no value for that cell.

The thermal conductivities are tiny, around 0.01 to 0.04 W/m·K, which is why freeze drying is slow: heat creeps through the dried layer to the ice front. The sublimation temperatures are all well below zero, from -7°C for apple to -29°C for salmon, which is why the product stays cold and its aroma stays put.

Other drying methods

The book closes the chapter with other types of drying, each suited to a particular food or situation: osmotic dehydration, where water is drawn out by a concentrated sugar or salt solution before air drying; solar drying, where the sun supplies the heat; drum drying, where a thin film of liquid dries on a hot rotating drum; microwave drying, where the heat is generated inside the food itself; and fluidized bed drying, where the pieces are suspended in a stream of hot air so that every surface sees the air. The chapter gives each of these briefly, and the choice between them turns on the same questions as always: the form of the food, the moisture to be removed, the quality to be kept, and the cost that can be borne.

6.8 Worked examples: sizing the air and the heat

The chart examples in section 6.3 show how to read the air. These examples show how to use those readings to size a dryer.

Worked example 6.4: how much air to remove a given amount of water (Earle Example 7.9)

Air at 60°C and 8% relative humidity enters a dryer and leaves at 35°C. From the chart, the inlet humidity is 0.010 kg kg⁻¹ and the specific volume is 0.96 m³ kg⁻¹. The outlet humidity is 0.0207 kg kg⁻¹. The water removed is 0.0207 - 0.010 = 0.0107 kg per kg of air. To remove 20 kg of water per hour, the air needed is 20/0.0107 = 1,869 kg h⁻¹, which at 0.96 m³ kg⁻¹ is 1,794 m³ h⁻¹. The answer is set by the difference between the outlet and inlet humidities: the wider that gap, the less air is needed.

Figure 6.1: Psychrometric chart, humid temperature product

The psychrometric chart (Figure 6.1) with the readings of this example: inlet air at 60 °C and 8% relative humidity, 0.010 kg kg⁻¹; outlet air at 35 °C, 0.0207 kg kg⁻¹. The water removed, 0.0107 kg per kg of air, is the gap between the two humidities.

Worked example 6.5: finding the relative humidity from the dew point (Earle Example 7.10)

Air leaves a dryer at 45°C with a dew point of 40°C. From the chart, the relative humidity is 76%. The dew point is a direct measure of how much water the air holds: air at 45°C that starts condensing at 40°C is nearly saturated.

Figure 6.1: Psychrometric chart, humid temperature product

The psychrometric chart (Figure 6.1) with the reading of this example: air leaving the dryer at 45 °C with a dew point of 40 °C, 76% relative humidity.

Worked example 6.6: a two stage tray dryer (Earle Example 7.11)

Air at 1,800 m³ h⁻¹, 18°C and 50% relative humidity is heated to 140°C, passed over trays, leaves at 60% relative humidity, is reheated to 140°C and passed over a second set of trays, leaving again at 60% relative humidity. From the chart, the initial humidity is 0.0062 kg kg⁻¹, the specific volume is 0.834 m³ kg⁻¹ and the enthalpy is 35 kJ kg⁻¹. Heated to 140°C the enthalpy is 160 kJ kg⁻¹. Following the wet bulb line to 60% relative humidity, the air leaves the first trays at 48°C with a humidity of 0.045 kg kg⁻¹. Reheated to 140°C, the enthalpy is 268 kJ kg⁻¹. Following the wet bulb line to 60% relative humidity again, the humidity is 0.082 kg kg⁻¹.

The total energy used is ΔH = 268 - 35 = 233 kJ kg⁻¹. The total water removed is ΔY = 0.082 - 0.0064 = 0.0756 kg kg⁻¹. The mass flow of air is 1,800/0.834 = 2,158 kg h⁻¹, which is 0.6 kg s⁻¹. The energy is 233 x 0.6 = 140 kW, and the water removed is 0.6 x 0.0756 = 0.045 kg s⁻¹, which is 163 kg h⁻¹. The exit air temperature is 60°C.

A printed inconsistency to note: the book states the initial humidity as 0.0062 kg kg⁻¹ but computes the water removed with 0.0064 kg kg⁻¹, giving ΔY = 0.0756 kg kg⁻¹. Using 0.0062, the difference would be 0.0758 kg kg⁻¹ and the water removed 163.7 kg h⁻¹. The difference is small, about 0.4%, and the book's own computed figures are given above as printed.

Figure 6.1: Psychrometric chart, humid temperature product

The psychrometric chart (Figure 6.1) with the readings of this example: inlet air at 18 °C and 50% relative humidity, 0.0062 kg kg⁻¹, heated to 140 °C and passed over two sets of trays, leaving at 0.082 kg kg⁻¹. The book states the initial humidity as 0.0062 kg kg⁻¹; see the note above.

Worked example 6.7: dehumidifying a room (Earle Example 7.12)

A room of 1,650 m³ has 6 air changes per hour. Ambient air at 31.5°C and 90% relative humidity is to be processed to 15°C and 80% relative humidity. The initial humidity is 0.0266 kg kg⁻¹ and the final humidity is 0.0085 kg kg⁻¹. The saturation temperature is 13°C, and the enthalpy at 13°C is 33.5 kJ kg⁻¹. The final enthalpy is 37 kJ kg⁻¹ and the specific volume is 0.827 m³ kg⁻¹. The mass of air is 1,650 x 6/0.827 = 11,970 kg h⁻¹. The water removed is 0.0266 - 0.0085 = 0.018 kg kg⁻¹, which is 215 kg h⁻¹. The reheat from 13°C to 15°C is ΔH = 3.5 kJ kg⁻¹, giving 41,895 kJ h⁻¹, which is 11.6 kW. Cooling the air to its dew point takes the water out; reheating it a little brings it back to a comfortable temperature at a lower humidity.

Figure 6.1: Psychrometric chart, humid temperature product

The psychrometric chart (Figure 6.1) with the readings of this example: ambient air at 31.5 °C and 90% relative humidity, 0.0266 kg kg⁻¹, processed to 15 °C and 80% relative humidity, 0.0085 kg kg⁻¹.

Worked example 6.8: checking the Lewis relationship (Earle Example 7.16)

The Lewis relationship links the heat transfer coefficient h and the mass transfer coefficient k: h/k is approximately equal to the humid heat, about 1,000 J kg⁻¹ °C⁻¹. In Example 7.16, k = 0.0150 kg m⁻² s⁻¹ and h = 15 J m⁻² s⁻¹ °C⁻¹, so h/k = 15/0.0150 = 1,000 J kg⁻¹ °C⁻¹, which matches the humid heat. The check confirms that the heat and mass transfer coefficients measured for the dryer are consistent with each other, which is the same consistency that the two forms of the constant rate equation, Eqs. 17.16 and 17.17, express.

Diagram note: Example 7.16 has no diagram. It is a one-line check of the ratio h/k against the humid heat, with no equipment, streams or geometry to draw.

Quick check

In Example 6.6, why is the air reheated to 140°C between the two sets of trays instead of being sent straight to the second set?

Check your answer

Because the air leaves the first trays at 60% relative humidity and 48°C, nearly saturated and cool, so it has little drying power left. Reheating drops its relative humidity and restores its ability to take up water.

Try it yourself: watch a drying curve form

Weigh a few thin slices of apple, spread them on a rack in a warm oven with the door slightly open, and weigh them every 15 minutes. Plot the weight against time, then plot the rate of weight loss against the moisture left. You will see the rate hold fairly steady while the slices are wet, then fall away as they dry, the same shape as Figure 6.2. Note the moisture at which the fall begins: that is the critical moisture for your apple slices at your oven conditions.

6.9 What the books do and do not give

The books give the psychrometric framework, the drying rate theory, the diffusion model, the energy balances and the dryer types, with worked examples for the energy and the air side. What they do not give is a worked example that takes a real food through the full drying time calculation from the constant rate to the end of the falling rate period, with numbers. The drying time equations are given in general form, and the effective diffusivities are tabulated, so a reader can assemble the calculation, but no single example in either book does it end to end. The dryer types other than spray drying and freeze drying are described briefly rather than worked through. The equilibrium moisture curves are given for a few foods only, so for any other food the equilibrium moisture must be measured or found elsewhere. These gaps are stated here so the reader knows where the books stop.

Pause and think: drying is the oldest preservation method and still one of the hardest to get right. The air can be made as hot and dry as you like, but the food sets the pace once the surface dries. The best dryer is not the hottest one: it is the one whose air matches what the food can give up, stage by stage, from the wet surface to the dry core.

Key ideas to carry forward

  • A dehydrated food holds no more than 2.5% water; a dried food may hold more.
  • A food cannot be dried below its equilibrium moisture content by air at a given temperature and humidity, however long it stays in the dryer.
  • Heating air at constant humidity lowers its relative humidity and gives it drying power; that is why a dryer heats its air first.
  • The wet bulb temperature is the temperature of the food surface during the constant rate period, and the wet bulb depression measures the humidity.
  • Drying has a constant rate period while the surface stays wet, then a falling rate period once the moisture falls below the critical moisture, when diffusion inside the solid sets the pace.
  • The critical moisture for many foods sits at a water activity of 0.58 to 0.65.
  • Most of the heat in drying goes to the latent heat of evaporation, about 2,257 kJ per kg of water at 100°C, and more at lower pressure.
  • Drying time grows with the square of the thickness, so thin slices dry far faster than thick ones.
  • Spray drying turns liquid into powder in seconds by atomizing it into hot air; droplet size is set by the atomizer, and disk speed matters most for a rotary atomizer.
  • Freeze drying sublimes ice below the triple point, 627 Pa at 0°C, so the structure survives and the aroma stays, at the highest cost of any drying method.

Glossary

Absolute humidity

Mass of water vapour per mass of dry air, in kg water per kg dry air. Food tech example: air at 60°C and 8% relative humidity has an absolute humidity of 0.010 kg/kg, which is the starting point for sizing a dryer.

Adiabatic saturation temperature

The temperature air reaches when it is cooled to saturation without heat being added or removed. Food tech example: the temperature the air follows along a wet bulb line as it dries a wet tray of fruit.

Bound water

Water held tightly by the food, by hydrogen bonds and other strong forces, with a vapour pressure below that of free water. Food tech example: the last few percent of water in dried milk powder, which leaves only slowly and at higher temperatures.

Constant rate period

The first stage of drying, when the surface stays wet and water evaporates at a steady rate set by the air. Food tech example: wet potato slices drying at a steady rate while their surfaces stay damp.

Critical moisture content

The moisture at which the constant rate period ends and the falling rate period begins. Food tech example: the moisture of a food when its surface first starts to dry out, often at a water activity of 0.58 to 0.65.

Dehydration

Drying to a moisture content of no more than 2.5% water. Food tech example: instant coffee powder, dried to below 2.5% water so it keeps without refrigeration.

Dew point

The temperature at which air becomes saturated when cooled, and condensation begins. Food tech example: air leaving a dryer at 45°C with a dew point of 40°C is at 76% relative humidity.

Effective diffusivity

The single number that describes how fast water moves through a food during the falling rate period, in m²/s. Food tech example: apples at 66°C have an effective diffusivity of 6.40 x 10⁻⁹ m²/s, about 250 times faster than potatoes at 54°C.

Equilibrium moisture content

The moisture a food settles at in air of a given temperature and humidity, and the lowest moisture that air can dry it to. Food tech example: potato at 20°C and 30% relative humidity settles at 0.1 kg water per kg dry potato.

Falling rate period

The stage of drying after the critical moisture, when the rate falls because water must diffuse through the inside of the solid. Food tech example: the long slow tail of drying raisins, where the inside stays moist long after the surface looks dry.

Free moisture content

Moisture above the equilibrium moisture content, the part that can be removed by the drying air. Food tech example: a food at 0.5 kg water per kg dry solids with an equilibrium moisture of 0.1 has 0.4 kg/kg of free moisture.

Freeze drying

Drying by freezing the food and subliming the ice under vacuum, below the triple point of water. Food tech example: freeze dried coffee, which keeps its shape and aroma because the ice never melts.

Humid enthalpy

The enthalpy of dry air plus its water vapour, referred to liquid water at 0°C. Food tech example: air at 25°C dry bulb and 20°C wet bulb has an enthalpy of 57 kJ/kg, used to size the heater.

Humid heat

The heat needed to raise 1 kg of dry air plus its water vapour by 1°C, equal to 1 + 1.92X kJ per kg dry air per °C. Food tech example: the humid heat of air with 0.010 kg/kg humidity is 1.019 kJ per kg dry air per °C.

Humid volume

The volume of 1 kg of dry air plus the water vapour it contains. Food tech example: air at 40°C has a specific volume of 0.906 m³/kg, used to turn a volume flow into a mass flow.

Hygroscopic material

A material that holds bound water with a vapour pressure below that of liquid water at the same temperature. Food tech example: starch and protein rich foods, which hold water tightly by hydrogen bonds.

Latent heat of sublimation

The heat needed to turn ice directly into vapour, 2,838 kJ/kg at 0°C. Food tech example: the heat that must be supplied to freeze dried strawberries, higher per kg than the latent heat of evaporation.

Latent heat of vaporization

The heat needed to turn liquid water into vapour, 2,257 kJ/kg at 100°C and higher at lower pressure. Food tech example: the main heat cost in drying, about 85% of the total in Example 6.1.

Psychrometric chart

A chart that plots the properties of moist air, temperature, humidity, enthalpy and relative humidity, on one page. Food tech example: the Mollier diagram used to find that heating air from 25°C to 40°C drops its relative humidity from 64% to 27%.

Relative humidity

The ratio of the water vapour pressure in air to the saturation pressure at the same temperature, expressed as a percentage. Food tech example: air at 60% relative humidity leaving a tray dryer, nearly saturated and in need of reheating.

Spray drying

Drying a liquid by atomizing it into fine droplets in hot air, so it dries in seconds to a powder. Food tech example: milk spray dried to powder, first done around 1900.

Triple point

The pressure and temperature at which solid, liquid and vapour water exist together, 627 Pa at 0°C. Food tech example: freeze drying must run below the triple point so ice sublimes instead of melting.

Wet bulb temperature

The temperature a wet surface reaches in a stream of air, set by the balance of evaporation and heat transfer. Food tech example: the temperature of a wet food surface during the constant rate period of drying.

References

  • Ibarz, A. and Barbosa-Cánovas, G. V. Unit Operations in Food Engineering. CRC Press, 2003. Chapters 5 and 17.
  • Earle, R. L. Unit Operations in Food Processing. NZIFST, 1983. Chapter 7.
  • Brennan, J. G., Butters, J. R., Cowell, N. D. and Lilly, A. E. V. Food Engineering Operations. Applied Science Publishers, 1976. Chapter 12.
  • Barbosa-Cánovas, G. V. and Vega-Mercado, H. Dehydration of Foods. Chapman and Hall, 1996. Cited for the definition of dehydrated food at 2.5% water.
  • Okos, M. R., Narsimhan, G., Singh, R. K. and Weitnauer, A. C. Food Dehydration, in Heldman, D. R. and Lund, D. B. Handbook of Food Engineering. Marcel Dekker, 1992. Cited for Table 17.1 effective diffusivity values.
  • Masters, K. Spray Drying Handbook. Longman, 1991. Cited for Table 17.4 rotary atomizer constants.
  • Schwartzberg, H. G. Freeze Drying, in Handbook of Food Engineering. Cited for Table 17.6 thermal conductivity and sublimation temperatures.