SOP: Counting Coliforms, Faecal Coliforms and E. coli by Most Probable Number (MFHPB-19)

GIFSQ ID: SOP-0945

Low numbers of indicator organisms call for statistics rather than plates. A most probable number (MPN) design dilutes a sample across five-tube sets, watches which broths produce gas, and converts a pattern of positive tubes into an estimated count. Testing proceeds in stages: presumptive coliforms first, confirmed coliforms next, faecal coliforms after that, and finally biochemical proof of aerogenic Escherichia coli.

One caution belongs up front. Pathogenic serotypes such as enterohemorrhagic O157:H7 often fail the faecal coliform reaction, so this procedure must never be used to isolate or enumerate illness-associated E. coli serotypes. Coliform and faecal coliform are operational labels defined by medium, time and temperature, not taxonomic groups.

Purpose

Purpose is to enumerate coliforms, faecal coliforms and aerogenic E. coli in foods, food ingredients and water, including contact water from food plants. Indicator findings can signal inadequate processing, post-process contamination or microbial growth, and faecal indicators can suggest faecal contamination, although both groups also survive and multiply outside intestines, including in processing plants. Judge results only against limits tied to this method, since standards are method-specific.

Scope

Scope covers general foods, water, fish products and shellfish, each with its own set-up below. Sample units may be analysed singly or combined where a sampling plan allows, with composites preferably no larger than 500 g. Keep units refrigerated at 0–5°C or frozen by product type, thaw without growth or death, analyse promptly, and start shellfish within 24 h of collection.

Equipment and Materials

  • Peptone water 0.1% and 0.5%; aqueous sodium citrate 2.0% tempered to 40–45°C, for cheese
  • Lauryl sulfate tryptose (LST) broth; brilliant green lactose 2% bile (BGLB) broth; E. coli (EC) broth, with or without MUG
  • Levine eosin methylene blue (L-EMB) agar or Endo agar; MacConkey agar; nutrient agar or another non-selective agar
  • Circulating covered water baths at 44.5°C and 45°C, water above medium level in immersed tubes; calibrated traceable thermometer; incubator at 35°C; stomacher or blender
  • IMViC media and reagents: tryptone broth with indole reagents, buffered glucose broth with methyl red and Voges-Proskauer reagents, Simmons citrate agar; or rapid identification kits such as API or VITEK
  • pH meter reading to 0.1 units across pH 5.0–8.0, or pH paper resolving 0.3–0.5 units; ultraviolet light at 366 nm for EC-MUG
  • Controls: gas-producing E. coli at 44.5/45°C with typical L-EMB reactions, and β-glucuronidase-positive when EC-MUG is used, as positive control; Enterobacter aerogenes or equivalent indole-negative, methyl red-negative, Voges-Proskauer-positive, citrate-positive organism as EMB/IMViC negative control; Salmonella berta or equivalent gas-negative organism as MPN broth negative control, because some E. aerogenes strains throw small false gas bubbles in LST, BGLB and EC broths

Procedure

  1. Ready sterile peptone water, disinfect benches, and arrange LST tubes in rows of five, marked by sample and dilution.
  2. Set up water and general foods as follows. Water: inoculate five tubes of 10 mL double-strength LST with 10 mL undiluted water each, five tubes of single-strength LST with 1 mL each, and five tubes of single-strength LST with 0.1 mL each; report per 100 mL. General foods: homogenise liquids to uniformity and build solid units from several locations; make a 1 in 10 dilution by blending 11 (10) g or mL into 99 (90) mL diluent, or 50 g into 450 mL for a five-subsample composite. Fish products may instead use 100 g blended with 300 mL 0.1% peptone water for 2 min as a 1 in 4 homogenate, then 40 g homogenate into 60 mL 0.1% peptone water to reach 1 in 10, reporting per 100 g. Diluent choice follows the food: liquids pipetted directly and/or into peptone water; viscous liquids weighed into peptone water; water-soluble solids, powders, meats, spices, shellfish and fish weighed into peptone water with shaking, blending or stomaching as suited; all cheese into 2% sodium citrate pre-warmed to 40–45°C with blending or stomaching.
  3. Keep blending to 2.5 min maximum, use low speed for foaming foods and sample below any foam. Check suspension pH and adjust to 7.0 with sterile 1 N NaOH or 1 N HCl whenever pH falls outside 5.5–7.5. Let dry-food homogenates stand 15 min at room temperature; proceed without delay otherwise.
  4. Prepare decimal dilutions with a fresh sterile pipette per transfer, shaking each dilution 25 times through a 30 cm arc in about 7 seconds, and shake again immediately before every transfer. Inoculate five single-strength LST tubes per dilution with 1 mL each, starting with 1 mL of the 10−1 dilution in the first row.
  5. Set up shellfish separately, always in 0.5% peptone water. Take live animals only for unfrozen product, selecting 10 or more animals to obtain at least 200 g meat and liquor. Scrub shells, including crevices, with a sterile stiff brush under potable running water without aerator faucets, drain on clean towels or in a clean container, and disinfect hands with soap, potable water and 70% alcohol, or gloves with iodophore or 70% alcohol; a mail glove may sit under a disposable glove. Shuck through the bill, not the hinge, with a sterile knife into a sterile container. Blend at least 200 g meat and liquor with an equal weight of 0.5% peptone water for 1–2 min to make a 1 in 2 dilution, then add 20 g homogenate to 80 g peptone water for 1 in 10. Dilute and inoculate within 2 min of blending: 10 mL of 1 in 10 dilution into each of five double-strength LST tubes, 1 mL of 1 in 10 into each of five single-strength tubes, and 1 mL of 1 in 100 into each of five single-strength tubes. Total time from shucking to incubator must stay within 20 minutes under the Canadian Shellfish Sanitation Program. Report shellfish per 100 g.
  6. Verify each elevated-temperature bath with one LST tube carrying the broth positive control and one carrying the broth negative control, transferring both into every medium used later, plus an uninoculated tube for each procedural step as a media control. Mix inoculated tubes by gentle shaking or rotation without trapping air in gas vials.
  7. Incubate LST at 35°C for 24 ± 2 h and examine for gas, shown by a bubble or effervescence. Start confirmation from every gas-positive tube. Incubate gas-negative tubes for another 24 ± 2 h, except raw shellfish and fish products, add any new positives, and confirm those as well. No gas in any tube after 48 ± 4 h overall, or after 24 ± 2 h for raw shellfish and fish, is a negative presumptive test.
  8. Confirm coliforms in BGLB: transfer one loopful from each mixed gas-positive LST tube, avoiding pellicle, into 10 mL BGLB with a gas vial, using sterile wood applicators or equivalent if preferred. Mix without trapping air and incubate at 35°C for 24 ± 2 h, then hold gas-negative tubes a further 24 ± 2 h and add new positives. Gas at any point within 48 ± 4 h is a positive confirmed coliform test.
  9. Confirm faecal coliforms in EC broth at the same time as the BGLB transfer: one loopful from each gas-positive LST tube into 10 mL EC broth with a gas vial. Incubate in a water bath at 45°C for 24 ± 2 h, or at 44.5°C for shellfish and fish products, with bath water at least 1 cm above medium level. Examine for gas and begin E. coli identification the same day from gas-positive tubes. Extend gas-negative tubes by 24 ± 2 h except for raw shellfish and fish, adding new positives. Gas within 48 ± 4 h, or within 24 ± 2 h for raw shellfish and fish, is a positive faecal coliform test; no gas by then is negative.
  10. Check EC-MUG tubes under UV at 366 nm alongside negative controls that must not fluoresce: blue-green fluorescence is a presumptive E. coli positive and those tubes may go forward to confirmation.
  11. Identify E. coli by streaking a loopful from each gas-positive EC tube or fluorescing EC-MUG tube onto L-EMB or Endo agar, incubating at 35°C for 18–24 h, and looking for typical non-mucoid, nucleated, dark-centred colonies with or without metallic sheen. A laboratory supervisor decides which dilutions and tube sets get confirmed and how many colonies per plate get picked.
  12. Purify before biochemical work. Well-isolated typical colonies: pick one onto nutrient agar, EMB or MacConkey, circle a second typical colony on the stored 4°C EMB plate as backup, and incubate at 35°C for 18–24 h. Poorly isolated colonies: pick two typical colonies, restreak onto EMB for discrete colonies, move one well-isolated colony to non-selective agar, refrigerate the second EMB plate, and incubate the same way.
  13. Confirm by GIMViC or a rapid kit. For GIMViC, inoculate each isolate into secondary EC broth (G), tryptone broth (I), two buffered glucose broths (M and V) and Simmons citrate agar (C), with IMViC positive and negative controls in IMViC media and MPN controls in secondary EC broth; complete testing within 96 h of non-selective plating or prepare fresh plates or slants first. Incubate G tubes at 44.5°C or 45.0°C for 24 ± 2 h, extending gas-negative tubes another 24 ± 2 h. Incubate indole tubes at 35°C for 24 ± 2 h and add indole reagent: dark red in the alcohol layer is positive, orange suggests skatole and may be reported ±, yellow is negative. Incubate MR/VP broths at 35°C for 48 ± 2 h: eosin pink within 5–10 min is VP-positive; red is MR-positive and yellow MR-negative. Streak citrate slants lightly with a straight needle, avoiding nutrient carryover that can fake a blue shift, and incubate at 35°C for 48 ± 2 h: visible growth with green-to-deep-blue change is positive. Typical E. coli patterns are Type I, G+ I+ M+ V− C−, and Type II anaerogenic, G− I− M+ V− C−. When a first isolate gives a non-characteristic pattern, test the backup isolate; only when both fail is E. coli considered absent from that primary EC tube. Rapid kits follow manufacturer instructions.

Recording Results

Compute a separate MPN for confirmed coliforms, faecal coliforms and confirmed E. coli, each from its own count of qualifying positive tubes. Report foods per g or mL, shellfish and fish products per 100 g, and water per 100 mL.

MPN table rules, stated in full so no external table logic is needed beyond the standard five-tube MPN table itself: the table gives MPN per 100 g or mL for patterns from three consecutive five-tube sets representing 10, 1 and 0.1 g or mL portions, for example pattern 5-1-0 reads 33 per 100 g, pattern 5-5-2 reads 540 per 100 g, pattern 5-5-5 reads >1,600 per 100 g, and pattern 0-0-0 reads <1.8 per 100 g. Diluent volume carried with a portion is ignored. Convert with: MPN per 100 g (mL) = table value × dilution factor of the middle set, where dilution factor means the reciprocal of the middle set’s dilution; divide by 100 for a result per g or mL. Worked check: sets holding 1, 0.1 and 0.01 g with a 5-1-0 pattern give a table value of 33; multiplying by 10, the middle-set factor, gives 330 per 100 g, or 3.3 per g.

Choosing which three sets to read follows fixed rules. With exactly three dilutions, use all three. With more than three, use only three consecutive sets: pick the highest dilution in which all five tubes are positive, plus the next two higher dilutions. When no set is fully positive, use the first three dilutions. A positive tube beyond the chosen three gets added to the count of the next lower dilution within the chosen set. When every tube in every set is positive, use the three highest dilutions and prefix the result with >. Further worked patterns: undiluted through 1:100 sets reading 5/5, 5/5, 2/5 use pattern 5-5-2, table 540, middle factor 1, giving 5.4 per g; the same pattern shifted one dilution deeper uses middle factor 10, giving 54 per g; sets reading 5/5, 5/5, 2/5, 2/5 use the last fully positive set onward, pattern 5-2-2, table 95, middle factor 100, giving 95 per g; sets reading 2/5, 2/5, 1/5, 0/5 use the first three, pattern 2-2-1, table 12, middle factor 10, giving 1.2 per g; sets reading 5/5, 2/5, 1/5 with a stray positive in the next dilution become pattern 5-2-2, table 95, middle factor 10, giving 9.5 per g; all-positive sets give pattern 5-5-5 with a > result.

Quality Control

Temperature tolerance is tight where it matters most: 35°C incubators allow ± 1.0°C, except shellfish incubators at 35 ± 0.5°C; baths and incubators at 43–45.5°C must hold within 0.5°C, and water baths within 0.2°C, because excess heat kills target organisms. Bath controls, media controls and test-specific positive and negative controls must all behave before results are calculated. Media substitutions require equivalency proof by the analyst or supervisor.

Troubleshooting

  • Small bubbles in broth controls: check the negative-control organism; E. aerogenes can fake gas in MPN broths, so broth controls should use S. berta or an equivalent gas-negative strain.
  • Pellicle carried into confirmation broths: remix and transfer from below the surface; pellicle transfer distorts gas readings.
  • Air trapped in gas vials at set-up: remix gently and reset tubes before incubation; trapped air reads as false gas.
  • First isolate fails GIMViC: test the circled backup colony before calling a tube negative.

Interferences and Limitations

Acidic or alkaline foods outside pH 5.5–7.5 suppress recovery unless adjusted to pH 7.0. Results are statistical estimates whose precision depends on five-tube design and correct set selection, not direct counts. Anaerogenic E. coli Type II breaks the gas-first logic and relies on the full GIMViC pattern, while pathogenic serotypes that lack a faecal coliform reaction fall outside this procedure entirely.

Safety Notes

  • Follow UV precautions from the EC-MUG manufacturer when viewing fluorescence at 366 nm; never view the lamp directly.
  • Protect hands during shellfish shucking with disinfected gloves and an optional mail glove, and treat knives and broken shells as sharps.
  • Handle hot water baths at 44.5–45°C with care, keep bath water levels controlled, and dispose of enrichment cultures as biohazard waste.

Source Method

Adapted in original wording from Health Canada method MFHPB-19, Enumeration of Coliforms, Faecal Coliforms and of E. coli in Foods using the MPN Method, April 2002, Compendium of Analytical Methods, Volume 2. MPN selection and conversion rules follow Appendix D, Calculation of the Most Probable Number, January 1993, restated in place above.