SOP: Residual Content (QM) of Substances in Plastic Food-Contact Materials
GIFSQ ID: SOP-0967
Some migrants refuse to be measured where they land. A substance may break down in a food simulant, react during contact, or evaporate before analysis can catch it, and a migration figure built on that behaviour would flatter the material. Regulation answers the problem from the other end: instead of limiting how much may migrate, it limits how much may remain in the plastic itself. That ceiling on what stays behind is the maximum residual content, abbreviated QM, with an area-related form, QMA, for cases where thickness decides the exposure.
Measuring QM means getting the substance out completely. Migration is a gentle, gradient-driven process in which the material keeps its physical character; a QM determination is deliberately harsher. Solvent swells or partly dissolves the polymer, the analyte is released exhaustively, and analysis happens in a simpler matrix at a far higher concentration than any migration test would offer. Those advantages come at a price when QM is used to predict migration: a worst-case assumption that everything present could transfer.
Purpose
Purpose is to determine the residual content of a restricted substance in a plastic food-contact material or article by exhaustive extraction or direct measurement, and to judge the result against the QM or QMA value for that substance in EU Regulation 10/2011. A second use covered here is calculating maximum possible migration from a measured residual content, assuming total transfer, for comparison with a specific migration limit.
Scope
Scope covers substances for which EU Regulation 10/2011 sets a maximum permitted residual content because specific migration is difficult or impossible to determine, owing to chemical instability or high volatility of the migrant. Butadiene and vinyl chloride are the examples named in the source. QMA, the area-related residual limit, matters especially for thin layers such as lacquers and coatings. Residual-content measurement also serves compliance work for substances with a specific migration limit, through the total-transfer calculation, and supplies the starting concentration needed for migration modelling. A worst-case calculation from the amount of substance added during manufacture may replace measurement only for additives and processing aids, never for monomers.
Equipment and Materials
- Headspace gas chromatograph with FID or MS detection for volatile substances
- Soxhlet extractor or reflux apparatus for extraction of non-volatile substances with organic solvents
- Solvents chosen for the analyte and polymer: an extraction or dissolving solvent with good solubility for the target analyte that is also suitably aggressive toward the polymer matrix, swelling it or partially dissolving it, plus a second solvent for reprecipitation where the dissolution route is used, chosen so the analyte is not incorporated into the precipitate
- Cutting or grinding equipment for reducing test specimens before extraction
- Analytical balance, volumetric glassware, and the chromatographic finish required by the analyte (GC or LC as in the specific migration SOP)
- Reference substance for calibration, internal standard where the method calls for one, and blank polymer or solvent blanks
- Substance-specific standard from the EN 13130 series where one exists for residual content, for example Part 4 for 1,3-butadiene in plastics, Part 6 for vinylidene chloride in plastics, Part 8 for isocyanates in plastics, Part 17 for carbonyl chloride in plastics, Part 20 for epichlorohydrin in plastics, and Part 22 for ethylene oxide and propylene oxide in plastics
Procedure
- Confirm that QM is the right restriction. Check EU Regulation 10/2011 for the substance: record the QM value in mg per kg of material, or the QMA value in mg per 6 dm2 terms as the regulation expresses it, and confirm the reason a residual limit applies, typically instability or volatility. Note the linked specific migration limit as well where one exists, because the two are tied by convention: QM values rest on a historic assumed QM to specific migration ratio of 100.
- Prepare the specimen. Cut or grind the test specimen as the chosen method requires. Thin films can be extracted directly; thicker materials should be crushed or ground before extraction so solvent can reach the whole matrix. Weigh the portion and record thickness where a QMA or total-transfer calculation will follow, since both depend on layer thickness.
- Branch A: volatile substances by headspace. Where applicable, measure the analyte directly by headspace gas chromatography. Dissolve the polymer in an appropriate solvent first where the method requires it, seal the preparation in a headspace vial, equilibrate and analyse the vapour phase against calibration standards of the analyte. Butadiene and vinyl chloride work belongs on this branch.
- Branch B: non-volatile substances by exhaustive extraction. Extract the prepared specimen with an organic solvent using a Soxhlet extractor or under reflux, continuing until release is exhaustive. Analyse the organic extract for the target analyte by the selected chromatographic method.
- Branch C: dissolution and reprecipitation. Dissolve the polymer in a suitably effective solvent, then reprecipitate the polymer by adding another solvent that does not incorporate the analyte into the precipitate. Remove the precipitated polymer, and measure the target analyte remaining in the solvent.
- Choose solvents deliberately on any branch. A solvent must do two jobs at once: dissolve the target analyte well, and attack the polymer matrix hard enough to swell it or partially dissolve it. A solvent gentle on the polymer leaves analyte locked inside and understates QM.
- Quantify and express the result. Calibrate in the extraction or dissolution solvent, correct for blanks, and express residual content as mg of substance per kg of material. For QMA comparisons, convert using the measured contact area and specimen dimensions as the applicable standard directs.
- Apply the total-transfer calculation where the aim is a specific migration limit. Take the measured residual content, the layer thickness and the conventional surface-to-volume ratio of 6 dm2 per kg of food from the EU cube model, and calculate the concentration in food that would result if the entire residual content transferred. Worked logic from the source, for butadiene: the residual content is set at 1 mg/kg in the final product, and the specific migration limit is set as not detectable with a detection limit of 0.01 mg/kg, under EU Regulation 10/2011. Assuming a polymer density of 1 g/cm3 and the 6 dm2/kg ratio, the QM restriction coincides with the specific migration limit at a layer thickness of 166 µm; for thicker layers the material concentration corresponding to that limit falls below 1 mg/kg, and for thinner layers it rises above 1 mg/kg. Judge thin layers by QMA where the regulation provides one, because a plain QM figure is too severe for very thin layers and too relaxed for thick ones.
- Decide compliance. Compare measured QM or QMA directly with the regulatory value for a residual-limit substance. For the total-transfer route, a calculated migration at or below the specific migration limit shows compliance without further migration testing; a calculated value above the limit proves nothing about non-compliance and sends the material to a conventional migration test.
- Use the formulation shortcut only within its limits. Measurement may be omitted where the residual limit cannot be exceeded on the evidence of the amount of substance added to the material. Apply that worst-case reasoning to additives and processing aids only, never to monomers, and file the composition evidence with the result.
Recording Results
Record the substance, the QM or QMA value applied and its source entry in EU Regulation 10/2011, specimen mass, thickness and preparation (cut, ground or whole film), the branch used, solvents used for extraction, dissolution and reprecipitation, calibration basis, blank values, and the final result in mg/kg of material. Where a total-transfer calculation is reported, show residual content, density assumption, layer thickness, the 6 dm2/kg surface-to-volume ratio, and the calculated concentration in food beside the specific migration limit it was compared with. State whether compliance rests on a measured residual content, on a total-transfer calculation, or on formulation evidence for an additive or processing aid.
Quality Control
Prove exhaustiveness rather than assuming it: re-extract an already-extracted specimen portion, or extend extraction time on a duplicate, and confirm no further analyte appears. Run solvent blanks and a spiked polymer or spiked extract recovery with each set, because the aggressive solvents that make QM work can also carry contamination or degrade a labile analyte. Check homogeneity after grinding by analysing duplicate portions; the source barrier work using an analogous spiked-powder approach found incorporation at 1.38 ± 0.036 mg/g against a 1.5 mg/g target, a reminder that preparation variance is measurable and must be reported. Any headspace work needs sealed-vial integrity checks, since the analytes on that branch are volatile by definition.
Troubleshooting
- Second extraction still yields analyte: first extraction was not exhaustive; extend Soxhlet or reflux time, grind finer, or move to the dissolution and reprecipitation branch.
- Recovery low for a volatile analyte: suspect loss during specimen preparation and transfer; keep preparations sealed and cold where the method allows, and minimise open handling.
- Polymer will not dissolve or swell: solvent is too gentle for that matrix; select a more aggressive solvent that still dissolves the analyte well, as step 6 requires.
- QM passes but the layer is very thick: re-check against QMA or the total-transfer calculation, because thickness can make a plain QM pass misleading.
- Total-transfer calculation exceeds the specific migration limit: expected behaviour for a worst case; proceed to conventional migration testing instead of recording a failure.
Interferences and Limitations
Exhaustive extraction measures everything present, including substance that in real use would never migrate because partitioning favours the polymer or diffusion is too slow. QM therefore protects the consumer through severity, not through realism. Area effects cut both ways, as the butadiene thickness example shows: one fixed QM number cannot fit every layer thickness, which is exactly why QMA exists for thin layers, lacquers and coatings. Residual content can demonstrate compliance with a specific migration limit through total transfer, and can feed migration modelling, but it cannot demonstrate non-compliance with a specific migration limit; that statement requires migration testing into food or food simulants. Finally, a formulation-based shortcut is closed to monomers, however well the recipe is documented.
Safety Notes
- Carry out Soxhlet, reflux and dissolution work with flammable organic solvents in a fume hood away from ignition sources, as general laboratory practice.
- Handle butadiene, vinyl chloride and other volatile monomers as hazardous gases or volatile liquids: sealed systems, hood work, and the precautions on their safety data sheets.
- Take care with hot reflux apparatus and with grinding equipment used on rigid specimens.
- Dispose of extracts, precipitated polymer and solvent waste through the chemical waste route.
Source and Standard
Source and standard: drafted from Chapter 11, sections 11.2.6 and 11.3.8, with section 11.4.2 on total mass transfer, of Singh, Wani and Langowski (eds.), Food Packaging Materials: Testing and Quality Assurance (CRC Press, 2017). Governing documents cited by number are EU Regulation 10/2011, European Framework Regulation 1935/2004, and the EN 13130 series, including its parts for determination of substances in plastics.