SOP: Migration Testing with Surrogate Substances and Tenax (Dry Foods and High-Temperature Use)

GIFSQ ID: SOP-0968

Real migrants are awkward study subjects. A commercial film may contain none of the substance a laboratory needs to follow, or different amounts in every roll, and building a method around that uncertainty wastes months. Surrogate work flips the problem around: substances chosen for known volatility, polarity and molecular weight are put into a material at a controlled level on purpose, then followed wherever they go. Because one impregnated material can carry a whole set of surrogates at once, a limited run of experiments yields evidence about monomers, additives and contaminants as classes, about barrier performance, and about foods that ordinary simulants handle badly.

Dry and high-temperature contact is where surrogates earn their keep. Tenax, a powdered polymer of diphenylene oxide with a strong appetite for volatile and semi-volatile migrants, stands in for dry food and for the punishing surface temperatures of a microwave susceptor, where a liquid simulant would be meaningless. Tenax also appears in the European system as food simulant E, MPPO, for specific migration into dry foods. Used with its tendency to overestimate measured and corrected, Tenax gives a severe, reproducible test where food itself would be analytically hostile.

Purpose

Purpose is to measure migration using deliberately incorporated model (surrogate) substances and Tenax as a receiving medium, for dry-food contact and high-temperature applications such as microwave susceptors, and to carry out the related semidirect substitute and alternative fat simulant tests of EN 1186-14 and EN 1186-15. Results support method development, barrier evaluation and compliance screening; they do not replace a conventional migration test where non-compliance must be established.

Scope

Scope covers three connected branches: surrogate transfer studies, in which model substances are sprayed onto or equilibrated into cartonboard, susceptors or polymers and transferred to food or Tenax under defined heating; the Tenax test for microwave susceptors developed with the Fraunhofer Institute and submitted to CEN for adoption as a standard method; and substitute and alternative fat simulant testing under EN 1186-14 and EN 1186-15, where vegetable oil (simulant D2) is replaced because its complex matrix causes analytical problems. Barrier evaluation using a surrogate-loaded donor is included as a supporting branch.

Equipment and Materials

  • Tenax: poly(2,6-diphenyl-para-phenylene oxide), MPPO, in the European listing specified as particle size 60–80 mesh, pore size 200 nm
  • Model substances for board and susceptor work, spanning volatility and polarity: chlorobenzene (boiling point 132°C), 3-chloropropan-1-ol (161°C), 1-chlorononane (203°C), cyclohexylbenzene (240°C), butyl benzoate (249°C), benzophenone (305°C), benzyl butyl phthalate (380°C) and diethylene glycol dibenzoate (410°C); chlorinated compounds were chosen to avoid interference from non-chlorinated analogues generated during microwave heating
  • Model substances for the microwave burger board study: 1-chlorodecane, butyl benzoate, dimethyl phthalate, benzophenone and benzyl butyl phthalate, as a mixed solution in acetonitrile, each substance at 4 mg/ml, with propyl benzoate, d5-benzophenone and diphenyl phthalate as internal standards, plus crystal violet dye so application could be judged visually
  • Airbrush for spraying surrogate solutions, vapour-phase equilibration arrangement for volatile surrogates, and a 2 × 2 cm cartonboard plaque for checking impregnation level
  • Microwave oven, 700 W nominal power, for food heating studies; conventional laboratory oven for the standardised Tenax test
  • Petri dishes with glass plate covers, for the Tenax susceptor test
  • Extraction solvents including diethyl ether, acetonitrile/dichloromethane, and dichloromethane/cyclohexane for high-performance size-exclusion chromatography clean-up
  • Gas chromatograph–mass spectrometer operated in selected ion monitoring mode, with headspace sampling for volatiles; internal standards fluorononane for volatiles work and 1,9-dichlorononane for non-volatiles work
  • Substitute fat simulants: isooctane and ethanol 95%, for EN 1186-14 and EN 1186-15 work
  • Migration cell with a contact area of 0.25 dm2, low-density polyethylene recipient film and surrogate-loaded polyethylene powder for the barrier branch

Procedure

  1. Select surrogates to bracket the real migrants of concern. Choose substances covering the boiling point, molecular weight and polarity range of the monomers, additives, ink components or contaminants under study. Benzophenone represents a photoinitiator from UV-cure inks; sebacate esters and phthalates represent plasticisers used in printing inks or present as environmental contaminants in paper and board. Surrogates need not be identical to commercial migrants, but they must be chemically similar and span a similar boiling point range for conclusions to transfer.
  2. Incorporate the surrogates. For non-volatile substances, spray the surrogate solution onto the substrate by airbrush; the board study used an application rate of approximately 0.25 ml/dm2. For volatile substances, incorporate by vapour-phase equilibration instead, since spraying loses them. Analyse an overlaid plaque or portions of the impregnated material, with internal standard, to determine the level and homogeneity of incorporation before any transfer run.
  3. Branch A: transfer to food on microwave heating. Reassemble the package in the configuration under study, add the food, and heat following the manufacturer’s on-pack instructions. Homogenise the food immediately after heating, extract surrogates with acetonitrile/dichloromethane, separate the extract from fats by high-performance size-exclusion chromatography (dichloromethane/cyclohexane mobile phase), and analyse by GC-MS in selected ion mode. Express transfer as the percentage incorporated that reached the food. In the board study, replicate subsample agreement was within ±22%; transfer was highest for a burger heated directly on a susceptor with no paper bag, a paper bag reduced migration without stopping it, and volatiles transferred most, with 6–8% of 1-chlorodecane transferring against under 1% of benzyl butyl phthalate.
  4. Branch B: Tenax test for microwave susceptors. Cut a circle of impregnated susceptor of 0.6 dm2 area, place it in a petri dish, cover it with 2.4 g of Tenax and a glass plate, and heat for 10 min in a conventional oven at 180°C. That condition was adopted because it browned the board layer to the same degree as microwave heating of chips and pizza on the same materials, and oven heating is more uniform between laboratories. Extract the Tenax by shaking with diethyl ether (15 ml) and internal standard (0.5 mg). Calibrate by spiking surrogate solution with internal standards into blank Tenax ether extracts, and analyse by GC-MS in selected ion mode. For parallel food runs, homogenise heated food and clean up by size-exclusion chromatography for non-volatiles; for volatiles, homogenise with chilled distilled water and analyse slurry portions by headspace GC-MS with fluorononane internal standard.
  5. Interpret Tenax against food with reduction factors. Tenax overestimates migration, acceptably, because it provides a safety margin, but the margin must not become unrealistic. In the susceptor work, migration of volatiles into Tenax was typically under 10%, repeatability ran from ±10% for chips and Tenax to ±17% for pizza, and reduction factors, meaning the ratio of migration into Tenax to migration into food, ranged from 1 to 13 across substances and foods. Apply a reduction factor of 10 or 15 for substances with a boiling point above 180°C; for more volatile substances, no reduction factor is appropriate. Expect the pattern behind those numbers: percentage migration is very low for low-molecular-weight, high-volatility substances, rises steeply to cyclohexylbenzene, then declines steadily as boiling point rises further. Note also that Tenax heats slowly: thermocouple checks showed Tenax reaching only 144 to 155°C after 10 min in the 180°C oven, while the susceptor in contact with the hot dish heated rapidly.
  6. Branch C: substitute fat simulants under EN 1186-14. Where vegetable oil is technically impractical, replace simulant D2 with 95% ethanol and/or isooctane, depending on the polymer, pairing non-polar polymers with polar solvents, for example 95% ethanol with polyolefins, and vice versa. Use the standardised conditions of the conventional test. Confirm before relying on results that migration into the substitute overestimates migration into the regulated simulant; a substitute result that does not overestimate cannot support compliance.
  7. Branch D: rapid extraction under EN 1186-15. Extract migratable substances with isooctane for non-polar materials such as polyolefins, and with 95% ethanol for polar materials such as polyamide, exploiting the principle that like dissolves like: a well-matched solvent penetrates and swells the polymer and extracts rapidly. Apply the polymer and condition combinations in the table below. Where polymer polarity is unclear, run both solvents and use the higher value for assessment.
Polymer type of the food contact layerExtraction solventExtraction conditions
Polyolefins and copolymersIsooctane24 h at 40°C
Polyamides95% ethanol24 h at 40°C
PolystyreneIsooctane and 95% ethanol24 h at 40°C
Polyethylene terephthalate95% ethanol24 h at 50°C
Polyvinyl chloride (plasticised)Isooctane and 95% ethanol24 h at 40°C
Polyvinyl chloride (rigid)95% ethanol24 h at 50°C
Cases in doubt or unknownIsooctane and 95% ethanol24 h at 50°C
  1. Supporting branch: barrier evaluation with a surrogate donor. Load benzophenone into low-density polyethylene powder by spiking a diethyl ether solution (5 ml of a 0.03 mg/ml solution) into 100 g of powder and shaking overnight on a roller-shaker; that approach achieved 1.38 ± 0.036 mg/g against a 1.5 mg/g target. Place the loaded powder against one side of the test film in a migration cell of 0.25 dm2 contact area, with a low-density polyethylene recipient film (160 µm thick, density 0.92) against the other side. After exposure, separate donor, test film and recipient, extract portions by shaking with dichloromethane and internal standard (1-chlorodecane), and analyse by GC-FID. Read results through three phases: a lag phase while the migrant diffuses through the barrier without emerging, a diffusion phase proportional to the square root of time, and a plateau phase once migration becomes concentration limited.
  2. Decide what the result can support. A surrogate or Tenax result at or below the relevant limit, after any justified reduction factor, supports compliance as a screening or semidirect outcome. A result above the limit, or a substitute-simulant outcome that fails, sends the material to conventional migration testing; it never, on its own, establishes non-compliance.

Recording Results

Record each surrogate by name, boiling point, molecular weight, incorporation level found and technique (spraying or vapour-phase equilibration), with the homogeneity check result. Report transfer to food and to Tenax as percentage incorporated, alongside absolute migration in mg/dm2 or mg/kg where a limit comparison is made. State heating conditions exactly, list every reduction factor applied and its basis, and identify the branch behind every figure.

Quality Control

Blank Tenax, blank board and unspiked food controls run with every set, because Tenax extracts and heated board both contribute background peaks. Calibration standards are spiked into blank Tenax extracts, matching the sample matrix. Incorporation checks are not optional: plaque or portion analysis precedes heating. Foods are heated in triplicate and subsamples analysed in triplicate, giving the ±10% to ±17% repeatability quoted for susceptor work and ±22% agreement for burger work; a laboratory well outside those bands should investigate heating uniformity first.

Troubleshooting

  • Volatile surrogates missing after incorporation: spraying loses volatiles; switch that substance to vapour-phase equilibration and re-check loading.
  • Tenax result dwarfs the food result for a low-volatility substance: expected behaviour; apply the reduction factor of 10 or 15 for boiling points above 180°C rather than reporting the raw Tenax figure as migration.
  • Extraction in EN 1186-15 work is unexpectedly slow: solvent and polymer polarity are mismatched; recall the laurolactam example, rapidly extracted from polyamide 12 by 95% ethanol yet migrating only slowly into isooctane, and run both solvents, taking the higher value.
  • Browning in the Tenax test does not match microwave browning: the 10 min at 180°C equivalence was set by visual browning comparison for chips and pizza susceptors; other susceptor constructions need their own equivalence check before the standard condition is borrowed.
  • Barrier film shows instant transfer with no lag phase: consider manufacturing history; coextrusion above the melting point can load a barrier layer within seconds, removing the lag that a virgin film would show.

Interferences and Limitations

Surrogates illuminate classes of behaviour, not the legal fate of one named commercial migrant. Tenax trapping depends on a temperature race between volatilisation from the hot substrate and desorption from cooler Tenax, so volatiles can be under-trapped while less volatile substances are over-trapped. Paper is no reliable barrier here: transfer passed through a paper bag, and substances printed on the outside of board distributed through all layers. Alternative and substitute tests overestimate by design and can show compliance only. Barrier performance is time-bound: thin low-density polyethylene gave a benzophenone lag of 0.25 to 0.75 h at 40°C and 18 to 24 h at 5°C, 1 mm high-density polyethylene held for 79 h at 40°C, and 12 µm PET showed no transfer after two weeks at 40°C and only 0.1% after a second week at 70°C.

Safety Notes

  • Handle diethyl ether, isooctane and dichloromethane in a fume hood away from ignition sources; ether in particular forms explosive vapour mixtures, as general laboratory practice.
  • Take care with petri dishes and susceptors removed from a 180°C oven, and with microwave-heated foods that can release steam on opening.
  • Treat chlorinated model substances and phthalates as hazardous; prepare spiking solutions in a hood and dispose of extracts as chemical waste.
  • Never taste or use for any food purpose a food item that has been heated in a surrogate study.

Source and Standard

Source and standard: drafted from Chapter 6, The Use of Model Substances for Migration Studies, in Risch (ed.), Food Packaging: Testing Methods and Applications (ACS Symposium Series 753, 2000), and Chapter 11, section 11.4.1, in Singh, Wani and Langowski (eds.), Food Packaging Materials: Testing and Quality Assurance (CRC Press, 2017). Standards cited by number are EN 1186-14 for substitute tests with isooctane and 95% ethanol, EN 1186-15 for rapid extraction into fatty food simulants, and EU Regulation 10/2011 for food simulant E (MPPO, Tenax) and the screening-approach rules.