Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

SOP: Tensile Strength and Elongation of Paper and Board (ISO 1924-2 / TAPPI T 494)

GIFSQ ID: SOP-0976

Pull a paper specimen until it breaks and you learn whether a bag, wrap or carton board can survive web tension in converting, lifting loads in use, and the small abuses of filling lines and handling. Chapter 8 calls tensile work the most common strength test for paper: few other single tests speak so directly to whether a sheet will hold together when something pulls at its ends.

Interpretation needs honesty about what happens inside the grips. Clamps compress a specimen through its thickness and then drive apart, so shearing acts across the faces near each grip while natural sideways contraction is held back, setting up a sideways tensile stress close to the jaws. Stress near the grips is therefore complex, even though the dominant action across the specimen as a whole remains a straightforward pull apart.

Purpose

Determine the limiting resistance of a paper or board test piece to a breaking force applied at its two ends under standard method conditions, express tensile strength as breaking length where required, and determine tensile strain from elongation measured over a preselected gauge length.

Scope

Apply to paper and paperboard used in food packaging where resistance to pulling failure matters. Condition specimens before testing in a standard atmosphere of 23 ± 1 °C and 50 ± 2 % relative humidity, being the ISO 187 standard atmosphere, and test under that atmosphere, because moisture content strongly influences paper strength. Chapter 8 sets no universal pass value: compare results with the governing specification.

Equipment and Materials

  • Tensile testing machine with grips able to hold both ends of a test piece, drive apart, and apply and record the breaking force.
  • Grips tightened mechanically or pneumatically, as Chapter 8 describes, holding without crushing the specimen prematurely or letting it slip.
  • Means of measuring elongation over a preselected gauge length, so strain comes from that gauge section rather than from grip movement alone.
  • Specimen cutter giving clean, straight edges.
  • Conditioning room or cabinet able to hold 23 ± 1 °C and 50 ± 2 % relative humidity.
  • Record sheet capturing sample identity, breaking force, gauge length, elongation and any grip-area failure.

Procedure

  1. Take test pieces from a representative sample of the paper or board under test. Keep edges cleanly cut and free from nicks, which concentrate stress.
  2. Condition test pieces in the standard atmosphere of 23 ± 1 °C and 50 ± 2 % relative humidity (ISO 187) until they have come into equilibrium with that atmosphere. Chapter 8 gives no conditioning duration for this test, so readiness rests on equilibrium, not on an assumed number of hours.
  3. Mount a test piece between the grips, aligned so the pull runs along the specimen. Tighten grips mechanically or pneumatically so they compress the piece through its thickness firmly enough to transmit load without slip.
  4. Set or identify the preselected gauge length over which elongation will be measured. Strain belongs to that gauge section, not to the disturbed zones inside the grips.
  5. Start the machine and drive the grips apart, applying an increasing tensile load until the test piece breaks. Note the breaking force.
  6. Record elongation of the gauge length at break, and observe where failure occurred. Record any break at or inside a grip as such, since grip-zone stress is complex.
  7. Repeat with further test pieces from the sample, using identical mounting, gauge and loading practice throughout.

Recording Results

Record breaking force for each test piece and report tensile strength as required by the governing specification, generally expressed as breaking length, following Chapter 8 usage. Calculate tensile strain by dividing the elongation of the preselected gauge length by the original gauge length, and report elongation on that basis. Note specimen identity, conditioning atmosphere, gauge length used and failure location for every piece.

Quality Control

Check force calibration and grip condition as routine laboratory practice before a series, and watch early specimens for slip marks or crushed ends that signal grip trouble. Chapter 8 prescribes no numeric repeatability or replicate requirements for this test, so none is invented here: judge scatter by inspecting mounting, edges and failure locations first.

Troubleshooting

  • Specimens keep breaking at the grips: inspect jaw faces, reduce local damage during tightening, confirm alignment, and remember grip zones carry shear plus restrained contraction, not pure tension.
  • Specimen slips instead of breaking: increase grip security within the machine’s proper range and check for smooth, coated or contaminated faces that defeat clamping.
  • Elongation values look erratic: confirm elongation was measured over the stated gauge length, not inferred loosely from grip travel.
  • Results shift between sessions: verify conditioning equilibrium and test atmosphere first: paper strength follows moisture content closely.

Interferences and Limitations

Grip effects are built into this method. Near each jaw, shear across the faces, through-thickness compression and restrained lateral contraction combine into a complex stress state, while the middle gauge section carries the cleanest tension. Chapter 8 explains, for tensile specimens generally, how a widened transfer area and narrowed gauge section (the dog-bone idea) reduce stress concentration near grips: use that principle to understand results, not to redesign paper specimens beyond what the governing standard allows. Moisture, edge damage and misalignment remain the everyday limits on comparability.

Safety Notes

  • Keep hands clear of grips and moving crossheads while a machine is powered, and never reach in to steady a specimen under load.
  • Take care with cutters and with sharp board edges during specimen preparation.
  • Stop the machine and release load fully before removing broken ends from the grips.

Source and Standard

Drafted in original wording from Chapter 8, §8.3.6 (Tensile Strength) in Singh, Wani and Langowski (eds.), Food Packaging Materials: Testing & Quality Assurance, CRC Press, 2017. Companion standards for this SOP are ISO 1924-2, covering tensile properties by a constant rate of elongation method, and TAPPI T 494. Conditioning atmosphere stated here is the ISO 187 standard atmosphere of 23 ± 1 °C and 50 ± 2 % relative humidity.