SOP: Examining and Grading Sealed Metal Cans and Glass Containers (MFHPB-06)
GIFSQ ID: SOP-0940
A hermetic seal fails in measurable ways. Hooks overlap too little, wrinkles stay unironed, lugs sit crushed or stripped, and each fault can be graded rather than guessed. Tear-down examination turns a finished can or jar into evidence about how its closure was formed.
Cans and glass need different eyes: double seams are cut open and measured to a thousandth of an inch, while glass closures are first judged non-destructively, cap by cap, before any removal torque or security test destroys the state being assessed. Sequence therefore matters as much as measurement.
Purpose
Detect and evaluate defects that threaten the hermetic seal of metal cans and glass containers, supplying qualitative and quantitative assessment of double seams and glass closures, graded by severity and by potential for loss, or future loss, of container integrity.
Scope
Covers all two- and three-piece metal cans with a conventional double seam and glass containers with metal caps or lids, used for products requiring sterilisation. Defect classification follows the Canadian Food Inspection Agency Metal Can Defects, Identification and Classification Manual (1999), used alongside this SOP. Several measurements, including external seam dimensions, vacuum and headspace, are required in special investigational situations only, and optional tests are flagged as such where they appear.
Equipment and Materials
- Bacti-Disc cutters, metal nippers about 5 inches long, and a double-blade mechanical saw; a single-blade saw may substitute with two cuts about ¼ inch (6 mm) apart. Electric can opener for removing an end plate close to the seam.
- Seam micrometer reading to 0.001 inch; seam projector, or a computer with image analysis software, with a nomograph for percent overlap. Optional torque meter.
- Emery paper or a fine emery board, fibreglass eraser, for cleaning cut edges.
- Safety gloves for sharp objects, safety eye protection and hearing protection, mandatory for cutting metal and handling cut pieces.
- Laminar hood and biohazard hood, undiluted ethanol for surface disinfection, buffered chlorine solution and shallow tray plus funnel-and-steel-rod device for swollen cans, sterile plastic bags.
- Cleaning supplies: warm (40–45°C) 5% Extran 300 detergent solution or equivalent grease-removing detergent, soft brush, hot water, drying at 35°C.
- Supporting measurements where an investigation calls for them: Bourdon vacuum and net headspace reading, pH measurement, and vacuum or pressure micro-leak testing, each run by its own method before a container is opened for other analyses where order matters.
Procedure
- Handle swollen units as possible Clostridium botulinum hazards throughout. Wear gloves for sharp objects, eye protection and hearing protection whenever cutting metal or handling cut pieces.
- Place two coincident marks on label and can about 120° apart, using indelible ink, carborundum or diamond pencil on the can so marks survive handling, allowing the label position to be re-established after removal. In special investigations, remove the label, inspect the unit visually and store the label for future reference; otherwise note any unusual liquid stains or sharp-object perforations, and where none appear, remove the label and place an identification mark on the can.
- Identify each unit legibly and directly on the container so identity cannot be lost in handling, confirm identity ties to its parent sample, and record the complete code for every unit.
- Clean adhering food, dirt and soil from the surface. Very dirty units may be scrubbed with detergent and water, or soaked in warm detergent water for ½ hour, rinsed in hot water, brushed to remove residue, rinsed thoroughly in hot water and drained dry. Place cans in a laminar or biohazard hood, disinfect the surface with undiluted ethanol and let it dry. Mark every visible defect clearly, classified with the Metal Can Defects manual.
- Open normal, non-swollen cans only after ethanol disinfection and complete drying, cutting a hole about 5.0 cm in diameter in the centre of the manufacturer’s end with a sterile Bacti-Disc cutter or suitable device, sized to take a 10½ laboratory stopper, large enough to see through, empty contents and support micro-leak vacuum or pressure testing. Take portions for pH, microscopy and microbiological analysis first, and examine contents for off-odours, frothing, curdling or discolouration immediately after opening and before emptying. Sterilising discarded product is not required for normal cans.
- Open swollen cans over a shallow tray holding enough buffered chlorine solution, or equivalent, to catch drips. Cover the end with an inverted funnel, insert a steel rod, hold the funnel firmly and strike the rod sharply enough to pierce the end; keep the funnel in place until frothing and spraying fully stop. Alternatively, pierce inside a sterile plastic bag held firmly around the Bacti-Disc opener shaft and keep the container inside until venting completes, a route that works best for swollen flexible pouches. Then open to about 5.0 cm diameter, take portions for other analyses, and set contents aside in a suitable container for sterilisation before discarding, as for all swollen or suspect cans.
- Rinse emptied containers under running warm water, soak in warm (40–45°C) 5% Extran 300 or equivalent detergent for at least 30 minutes with soft brushing, rinse thoroughly under warm running tap water, dry at 35°C overnight, and cool to room temperature. For glass containers with metal lids, check for problems and move to visual inspection.
- Inspect visually by holding the container in one hand and rotating it with the other. On metal cans, run thumb and forefinger of the free hand over both ends and record every defect, always stating where it sits: can body, side seam, or a double seam end identified as manufacturer’s or canner’s end. An image analysis system at 25× magnification gives better results without risking fingers: run its fibre-optic lens around the double seam perimeter and along the side seam, digitise and save any serious fault, and examine body and side seam too, taking care around sharp end edges. Judge glass enclosures and caps using glass container defect classification.
- Take external measurements where an investigation requires them. On metal cans these are countersink, seam thickness and seam length. On glass they are cap tilt, cap security, lug position and, optionally, cap removal torque, which is destructive.
- Complete vacuum and net headspace measurement, pH measurement and micro-leak testing, where required, in an order that protects them: vacuum and headspace before the container is opened for other analyses.
- Prepare a seam cross-section, emphasising the coded, food processor’s end, because processor seams are usually poorer than manufacturer seams. Remove the end plate with the electric can opener as close to the double seam as possible. Cut the uncoded end directly across from the side seam and the coded end about 1 inch (2.5 cm) from the side seam, so torn-down seams stay identifiable by end. Where only a processor end is in question, one cut there suffices. Avoid any point where micro-leak testing showed a leak or visual examination showed a defect.
- Make the cross-section cut with the double-blade saw through the seam, or two cuts about ¼ inch (6 mm) apart with a single blade, extending the cut 1 inch (2.5 cm) down the can body and fully through the remaining end plate. Push the cut section outward to expose the seam cross-section, then sand or brush rough edges away with fine emery or a fibreglass eraser. At least one cross-section is required; special situations may call for three cuts at 120° to each other, accepting that three cuts make disengagement and interpretation harder.
- Separate body hook from cover hook. Cut into the remaining end plate if the saw has not already done so, using nippers. Turn up one corner of the can end with the nippers, grip the turned metal and tear back to the seaming panel radius, then re-grip and tear along that radius around the whole circumference, using the nippers as a lever with the double seam as fulcrum, working downward while gripping without cutting the end metal. Where no saw was used, cut through the double seam with nippers at the positions in step 11. Tap the cover hook gently down with the flat side of the nippers until it disengages from the body hook around the full periphery, using light blows that do not distort the body hook. Keep the removed cover hook in its original shape, because straightening it flattens wrinkles and flatters the tightness rating. Check both hooks for defects and uniformity, and record irregularities such as unevenness.
- Read percent overlap from the cross-section on the seam projector with the nomograph. For body hook butting: open the caliper fully, set the nomograph card so its reference lines sit parallel to the hook images, align zero at the inside of the body hook radius, move the card until the 100 line sits at the inside of the cover hook radius, and read the line at the end of the body hook. For cover hook butting, repeat the alignment and subtract the nomograph reading from 100. Total percent overlap equals body hook percentage plus cover hook percentage minus 100. Source worked figures: a cover reading giving 90% cover butting and a body-plus-cover sum yielding 75% total overlap.
- Or calculate overlap by formula. Measure cover hook and body hook lengths to the nearest 0.001 inch (0.025 mm) with the seam micrometer at points about 120° apart, excluding the crossover, and likewise measure end plate thickness, body plate thickness and double seam height to 0.001 inch. Percent overlap = (BH + CH + EPT − SH) × 100 ÷ (SH − (2 × EPT + BPT)), where BH is body hook height, CH is cover hook height, EPT is end plate thickness, BPT is body plate thickness and SH is double seam height. An image analysis system may perform the same measurements; follow its manufacturer instructions or local SOP.
- Grade tightness from wrinkles on the inner surface of the detached cover hook, as a percentage against the reference scale. Judge by the worst single point on the hook, watching both sides of the juncture closely. Slight impressions or images left by well-ironed wrinkles are not reported: regard the hook as smooth there, and check by viewing the cut edge from above; a straight, non-wavy edge confirms wrinkles were ironed out.
- Optionally grade the juncture, the roughly 3/8 inch (5 mm) wide cover hook zone crossing the side seam, on a percentage scale starting at 100% for a hook as long as elsewhere, dropping in 25% steps as its length shortens, so a quarter reduction rates 75%. Note that a sound juncture, with enough hook overlap, resists abuse, leaks and post-processing contamination. Optionally record the pressure ridge on the inside body wall for presence and uniformity, such as excessively heavy, light or uneven, remembering a clear ridge supports, but alone never proves, tightness, and record body and cover hook lengths where micrometer readings were taken.
- Evaluate glass closures in the right order: visual, non-destructive external checks first, cap removal and other destructive tests only after those observations are recorded.
- Judge cap tilt on side-seal and press-on twist (PT) caps: a cap should sit essentially level, not cocked or tilted, well down on the finish, judged against the transfer bead or shoulder, and tilt should not exceed 3/32 inch. A cocked cap on lug closures, where a lug fails to seat under the glass thread, shows as an unlevel, tilted cap.
- Check for crushed lugs, where a lug was forced down over the glass thread by the capper, which may hide without tilting the cap, and for stripped caps, where over-application has torn lugs off the glass threads so lugs pull outward on inspection.
- Assess the gasket on side-seal caps: it should be secure and even, never pulled, looped or broken at any point, and after cap removal it should carry a visible, even impression through a full 360° where it pressed the glass finish. Flag cut-thru, where the top of the glass finish has pushed completely through the compound to the metal coating, as a leaky seal needing immediate remedial action.
- Optionally check glass vacuum, temperature, headspace, removal torque, pull-up and security. Vacuum: a cap panel should show concavity after capping, PT caps need at least 3 in. Hg vacuum out of the capper to avoid loose caps, a vacuum button must be down after processing and cooling and pop up on opening, and exact vacuum is read with a gauge against the product’s normal range, destructively. Headspace should generally be at least 6% of container volume at sealing temperature. Removal torque, read on a standard torque meter on twist-off or PT caps, gauges seal security and over-tightening. Pull-up, or lug position, is measured in 1/16 inch increments from the vertical neck ring seam, one of two seams 180° apart and not necessarily aligned with body seams, to the leading edge of the nearest lug: right of the line is positive, left is negative, proper application usually sits near +4 (¼ inch right), with 0 to +8 still capable of good security. Security, the most reliable lug-application measure and a destructive test, is read by marking aligned vertical lines on cap and container, turning the cap counter-clockwise only until vacuum breaks, reapplying until compound touches the finish and the lug touches the thread, just finger-tight, then measuring line separation in 1/16 inch increments; cap line right of container line is positive. Proper security after processing and cooling is +2/16 to +5/16 inch (3.2 mm to 8 mm); values above the closure manufacturer’s capper range signal over-application to correct, and values consistently below minimum signal under-application to correct immediately.
Recording Results
Record every measurement and observation for each container, stating defect location by body, side seam or named seam end, and by glass feature where relevant. For seam micrometer work, record percent overlap for all three measurement sets but report the range, lowest value to highest value. Summary tables are recommended. Save digitised images of serious faults for future consideration.
Quality Control
Order is the main control: non-destructive glass checks before destructive ones, and vacuum, headspace and micro-leak work before a container is opened for other analyses. Micrometer readings to 0.001 inch at three positions about 120° apart, avoiding the crossover, keep a single odd spot from standing for a whole seam. Tightness and juncture grades are anchored to published reference scales rather than analyst impression, and tightness is always rated at the worst point.
Troubleshooting
- Cover hook looks suspiciously smooth: check whether it was straightened during removal; a flattened hook hides wrinkles and inflates tightness. Re-tear a fresh seam keeping the hook’s original shape.
- Body hook distorted after separation: tapping blows were too heavy; use the flat of the nippers with gentle taps on the next seam.
- Torn-down seams cannot be told apart by end: the cut positions were not followed; coded end cuts belong about 1 inch from the side seam, uncoded end cuts directly across from it.
- Lug position reads negative: suspect over-application, which in extreme cases strips the cap; confirm with a security measurement rather than pull-up alone.
- Security below range across a run: under-application is indicated and should be corrected immediately; security above range calls for bringing application back into range for best cap performance.
Interferences and Limitations
Cross-section and tear-down work destroys the seam it measures, and three cross-section cuts, while more complete, make disengagement and interpretation harder. Visual thumb-and-finger examination risks both missed faults and cut fingers, hence the 25× image route where available. Pressure ridge, pull-up and vacuum each support a judgement but none replaces the direct measurements: pull-up in particular must not stand in for security once their relationship for a given lot of glass and caps is understood. Countersink, seam thickness and seam length, plus vacuum and headspace, are special-investigation parameters, not routine requirements.
Safety Notes
- Wear safety gloves for sharp objects, safety eye protection and hearing protection for all metal cutting and cut-piece handling; the requirement is mandatory, not advisory.
- Treat swollen containers as possible Clostridium botulinum hazards, vent them under containment, and sterilise their contents before disposal.
- Take care around sharp can-end edges during visual examination, and prefer the fibre-optic image route where fingers would otherwise ride the seam.
Source Method
Adapted in original wording from Health Canada Health Products and Food Branch method MFHPB-06, Method for Examination and Evaluation of Hermetically Sealed Metal Cans and Glass Container, issued February 2003.