SOP: Calculation of the Most Probable Number (MPN) from Multiple-Tube Tests (Appendix D)

GIFSQ ID: SOP-0964

Some foods carry organisms at levels too low, or in matrices too particulate, for a plate count to give a trustworthy answer. Multiple-tube work answers a different way: dilute, inoculate sets of broth tubes, read which tubes turn positive, and convert a pattern of positives into a statistical estimate. Conversion step is where errors creep in, usually through picking wrong dilutions or applying a wrong multiplier.

Procedure below fixes that conversion. It covers a five-tube format, a table built for 10, 1 and 0.1 g (mL) portions, correction for portions actually used, and rules for choosing which three consecutive dilutions to read when more than three were inoculated.

Purpose

Aim is to convert numbers of gas-positive (or otherwise positive) tubes at each dilution into a Most Probable Number per 100 g (mL) and, where required, per g (mL), reproducibly and without arithmetic drift between analysts. Estimate remains statistical in nature, unlike a direct plate count expressed as colony forming units.

Scope

Use for multiple-tube coliform and similar liquid-media tests run with five tubes per dilution, where results are read from a standard MPN table for portions of 10, 1 and 0.1 g (mL). Principles of dilution selection and correction apply whenever portion sizes differ from table portions, provided tube numbers per set remain five. HGMF growth-unit calculations use a separate conversion and are outside scope here.

Equipment and Materials

  • Completed tube records showing, for each dilution, tubes inoculated and tubes positive
  • MPN Table I: values per 100 g (mL) for five tubes at 10, 1 and 0.1 g (mL) portions
  • Worked-examples Table II showing dilution selection and calculation patterns (examples a to g)
  • Dilution scheme record stating amount of original test material represented in each tube set
  • Calculator

Procedure

  1. Confirm tube reading is complete. For each dilution, note tubes inoculated (normally five) and tubes showing a positive reaction, such as growth with gas formation, after any confirmatory steps a method requires.
  2. Work out how much original material each tube set represents. Account for both portion volume placed in a tube and dilution of that portion. Ignore volume of diluent carried into a tube alongside test material when calculating MPN.
  3. Choose three consecutive dilutions for table entry, applying selection rules in steps 4 to 8. Only three dilutions ever enter a table lookup.
  4. Rule 1, exactly three dilutions inoculated: use results from all three dilutions as they stand.
  5. Rule 2, more than three dilutions inoculated: find highest dilution (smallest amount of product per tube) at which all five tubes are positive, then use that dilution plus next two higher dilutions.
  6. Rule 3, more than three dilutions inoculated but no dilution has all five tubes positive: use first three dilutions.
  7. Rule 4, a positive appears beyond chosen three: if any tube is positive in a dilution higher than third chosen dilution, add number of such positive tubes to positive count of third chosen dilution before entering table.
  8. Rule 5, every set is fully positive: where tubes in all sets of a series are positive, choose three highest dilutions and report final MPN with a greater-than sign, showing true value exceeds calculated value.
  9. Form a three-number combination in dilution order, for example 5-1-0 means five positives at first chosen dilution, one at second, none at third.
  10. Look up combination in Table I and read its tabulated value. Table I assumes portions of 10, 1 and 0.1 g (mL) and gives MPN per 100 g (mL). Illustrative entries include: 0-0-0 gives less than 1.8; 5-1-0 gives 33; 5-2-0 gives 49; 5-2-2 gives 95; 2-2-1 gives 12; 5-5-2 gives 540; 5-5-5 gives greater than 1600. Always read an actual value from a full table for reporting; do not interpolate.
  11. Determine dilution factor. Dilution factor equals reciprocal of dilution of an analytical unit. For calculation, use dilution factor belonging to middle set among three chosen dilutions.
  12. Calculate MPN per 100 g (mL) as: MPN/100 mL (g) = tabulated number of microorganisms × dilution factor of middle set of tubes. Equivalently, correct tabulated value by ratio between table portions (10, 1, 0.1) and amounts actually present in tubes.
  13. Convert to per g (mL) where a method asks for that basis: divide MPN per 100 g (mL) by 100.
  14. Check arithmetic against a worked pattern. Example: five tubes receive 10 mL of a 1:10 dilution (1 g per tube), five receive 1 mL of 1:10 dilution (0.1 g per tube), five receive 1 mL of a 1:100 dilution (0.01 g per tube), with positives 5-1-0. Table I value for 5-1-0 at 10, 1, 0.1 g is 33. Amounts actually used are one-tenth of table amounts, so multiply by 10: 33 × 10 = 330 organisms per 100 g (mL). Per g (mL), value is 330 ÷ 100 = 3.3.
  15. Cross-check dilution selection against standard patterns: a pattern using undiluted, 1:10 and 1:100 material with 5-5-2 gives table value 540, middle dilution factor 1, hence 5.4 per mL (g); same tube pattern shifted one dilution gives 54 per mL (g); a 5-2-2 pattern at higher dilutions with middle factor 100 gives 95 per mL (g); a low pattern 2-2-1 with middle factor 10 gives 1.2 per mL (g); a stray positive beyond chosen three converts 5-2-1 plus one extra positive into 5-2-2, giving 9.5 per mL (g); an all-positive series gives greater than 1600 per mL (g) after correction.
  16. Record combination used, table value, middle-set dilution factor, and final basis (per 100 g (mL) or per g (mL)) so a second analyst can retrace every step.

Recording Results

Report MPN on basis a method specifies, normally per g (mL) for foods rather than per 100 g (mL) used by drinking-water tables from which Table I was adapted. Preserve any greater-than qualifier arising under Rule 5 (for example, report as >1600 after correction where every tube is positive). Where a combination yields a less-than table entry, such as 0-0-0 giving <1.8 before correction, preserve less-than sign through correction and conversion. Never report an MPN as a direct count: it is an estimate derived from a pattern of positives, with precision governed by tube number and dilution spacing. State dilutions selected and any Rule 4 addition explicitly in bench records, since two different selections from one tube series can produce different estimates.

Quality Control

Have a second analyst independently select three dilutions and repeat table lookup and multiplier for a proportion of calculations, as generic good calculation practice. Verify that middle-set factor, not first- or last-set factor, was used. Confirm portion amounts account for dilution of material placed in tubes, not merely pipetted volume. Check that diluent volume was excluded from amount calculations, as source directs. Any discrepancy between duplicate calculations must be resolved from raw tube counts before reporting.

Troubleshooting

  • Result looks tenfold too low or high: recheck correction direction. Smaller actual portions than table portions require multiplication upward; larger portions require opposite correction.
  • No dilution is fully positive: apply Rule 3 and use first three dilutions instead of searching further down a series.
  • An isolated positive sits beyond chosen dilutions: apply Rule 4; add those positives to third chosen dilution count before table entry rather than discarding them or shifting window.
  • Every tube at every dilution is positive: series was under-diluted. Report with a greater-than sign using three highest dilutions, and repeat with higher dilutions if a quantified value is required by a method.
  • Tube numbers differ from five per set: do not use a five-tube table. Stop and use a table or calculation validated for tube number actually run.

Interferences and Limitations

Precision is inherently limited: identical true concentrations can yield different positive patterns by chance, and neighbouring table values can differ widely, especially at high combinations where values rise steeply (for example, 5-5-3 gives 920, 5-5-4 gives 1600, 5-5-5 exceeds 1600 per 100 g (mL) at table portions). Particulate matter and inhibitors in a matrix affect tube reactions upstream of calculation and cannot be corrected arithmetically. Table I covers only combinations achievable with five tubes at three dilutions (0 to 5 positives each); patterns outside its assumptions need a different validated approach. Source provides no separate confidence-interval table, so do not attach invented confidence limits to a reported MPN.

Safety Notes

  • Handle inoculated broth tubes as potentially containing pathogens; open and dispose of them under laboratory biological safety procedures, as generic practice.
  • Decontaminate spills of enrichment cultures promptly and record any exposure incident under local safety rules.
  • Autoclave or otherwise sterilise positive tubes before disposal through an approved waste stream.

Source Method

Based on Health Canada Appendix D, Calculation of the Most Probable Number (MPN), Volume 1 of Compendium of Analytical Methods, issued January 1993, including Table I values, Table II worked patterns and Table III dilution-selection guidance summarised in procedure above. Wording here is original; formulas, selection rules and worked values reproduce source exactly.