Wastewater Quiz
GIFSQ ID: ART-1907
Test your knowledge with this free 20-question Wastewater quiz from Food Sustainability & Environmental Systems, part of…
What this quiz covers
Food factories use large volumes of water, and most of it leaves as effluent carrying organic matter, fats, salts and cleaning chemicals. This quiz starts with how that effluent is measured. BOD, biochemical oxygen demand, is the oxygen microorganisms consume breaking down organic matter, and the standard BOD5 test fixes the conditions at five days at 20 degrees C so results can be compared. COD, chemical oxygen demand, oxidises pollutants chemically, so it includes matter microbes cannot break down, which is why COD is normally equal to or higher than BOD. A BOD/COD ratio above 0.5 means most of the load is biodegradable and biological treatment will work well. Total suspended solids are expressed in milligrams per litre, and FOG stands for fats, oils and grease, the oily fraction that causes blockages in drains and sewers.
The rest of the quiz follows the effluent from the plant to the river. Cleaning and wash waters, CIP rinses, equipment washdown and floor cleaning make up the largest volume of wastewater in a food plant, and cheese whey is among the strongest food effluents, with a BOD in the region of 35,000 to 50,000 mg/L, while dairy effluent in general often exceeds 1,000 mg/L from milk residues and whey. Discharging that strength untreated would strip oxygen from receiving waters, because microbes consume dissolved oxygen breaking the organic load down, and that oxygen depletion is what harms fish. Nitrogen and phosphorus cause eutrophication, algal blooms followed by oxygen depletion, hot CIP rinse water causes thermal pollution because warm water holds less dissolved oxygen, brines from cheese salting and pickle production raise salinity and total dissolved solids, and an acidic effluent at pH 4 corrodes concrete and pipework and inhibits biological treatment. Caustic CIP chemicals push effluent pH strongly alkaline, often above pH 10. Grease traps capture FOG before it enters drains, an equalisation tank evens out flow and pollutant load so downstream treatment receives a steady feed, and a time- or flow-proportioned composite sample represents the average discharge far better than a single grab sample. A discharge consent sets numerical limits on BOD, suspended solids, pH range and flow, and discharging trade effluent to the public sewer needs a trade effluent consent from the sewerage undertaker, often with pre-treatment conditions.
One idea runs through the set: measure the load, steady the flow, and treat before discharge
Effluent control starts with knowing what is in the water, then smoothing the peaks, then meeting the consent limits. Every number in this quiz is one piece of that chain.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the tests, the limits and the treatment steps a food environmental student is expected to know by heart.
Choose how you want to play
A short note: wastewater
Wastewater is used water carrying dissolved and suspended pollutants, and food-plant wastewater is mostly cleaning and wash water loaded with organic matter. Grease traps catch fats, oils, and grease before drains.
The BOD5 test counts the oxygen microbes consume over five days at 20 °C, and COD counts everything a chemical oxidant can oxidize, so COD always tops BOD. A BOD to COD ratio above 0.5 marks a waste as readily biodegradable. Food effluent is strong: dairy effluent tops 1,000 mg/L of BOD, and untreated cheese whey runs 35,000 to 50,000 mg/L.
The harm runs through oxygen. Microbes breaking down organic matter deplete dissolved oxygen, and fish suffer first. Nitrogen and phosphorus feed algal blooms, and dying algae deplete oxygen further. Hot CIP rinse water adds thermal pollution, since warm water holds less oxygen. Caustic CIP chemicals push effluent pH strongly alkaline, often above pH 10, while acid near pH 4 corrodes concrete and pipework and inhibits biology.
Control starts with steady flow. An equalization tank evens out flow and load for a steady feed, and composite sampling, time or flow proportioned, represents the average discharge far better than a single grab. Brines from cheese and pickling raise salinity and total dissolved solids. Discharge to a public sewer needs a trade effluent consent, and a permit sets limits on BOD, suspended solids in mg/L, pH range, and flow.
Sample as a flow-proportioned composite, not a single grab: limits are judged on the average load.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: FOG in effluent management stands for:
Correct answer: Fats, oils, and grease
FOG stands for fats, oils, and grease : the oily fraction that causes blockages and treatment problems in effluent. The other expansions are invented.
Question 2: Untreated cheese whey has a BOD in the region of 35,000, 50,000 mg/L, which means:
Correct answer: It is among the strongest food-industry effluents and would devastate receiving waters
Cheese whey at 35,000, 50,000 mg/L BOD is one of the strongest food effluents, so discharging it untreated would strip oxygen from receiving waters. Drinking water or harmless options ignore that strength.
Question 3: Grease traps (grease interceptors) are installed to:
Correct answer: Capture fats, oils, and grease before they enter drains and sewers
Grease traps capture fats, oils, and grease before they enter the drainage system, where they would congeal and block sewers. They protect the drain, not heat or measure the flow.
Question 4: Chemical oxygen demand (COD) differs from BOD in that COD:
Correct answer: Measures oxygen needed to chemically oxidise pollutants, including non-biodegradable matter
COD oxidises pollutants chemically, so it includes matter microbes cannot break down, while BOD measures only the biodegradable fraction. That is why COD is normally the higher figure.
Question 5: An environmental discharge permit (consent) for a food factory typically sets limits on:
Correct answer: Parameters such as BOD, TSS, pH range, and flow
A discharge consent sets numerical limits on parameters like BOD, suspended solids, pH range, and flow that the factory must meet. Delivery trucks and slogans are not environmental parameters.
Question 6: Total suspended solids (TSS) in effluent are expressed in:
Correct answer: Milligrams per litre (mg/L)
Total suspended solids are the mass of solids per unit volume of effluent, so they are expressed as milligrams per litre. pH, temperature, and energy units measure different things.
Question 7: What does the BOD₅ test measure in food-plant effluent?
Correct answer: The oxygen consumed by microorganisms breaking down organic matter over 5 days at 20°C
The BOD₅ test measures the oxygen microorganisms consume breaking down organic matter over five days at 20°C : the standard fixed conditions that make results comparable. Dissolved plastic or bacterial counts are different measurements.
Question 8: Which streams typically make up the largest volume of wastewater in a food processing plant?
Correct answer: Cleaning and wash waters, CIP rinses, equipment washdown, and floor cleaning
Wash waters, CIP rinses, equipment washdown, and floor cleaning dominate food-plant wastewater volumes because cleaning is constant. Ingredients and sprinklers are minor volumes by comparison.
Question 9: Why is composite sampling preferred over a single grab sample for consent monitoring?
Correct answer: A time- or flow-proportioned composite represents the average discharge over the period
Effluent quality varies through the day, so a time- or flow-proportioned composite represents the average discharge, while one grab sample captures only a moment. Consents are judged on the average load, not a snapshot.
Question 10: Caustic cleaning-in-place (CIP) chemicals typically shift effluent pH:
Correct answer: Strongly alkaline, often above pH 10
Caustic CIP solutions are strongly alkaline, so their carryover pushes effluent pH well above neutral, often past pH 10. An acidic or neutral shift would come from acid cleaning, not caustic.
Question 11: Nitrogen and phosphorus in food-plant effluent are environmental concerns because they:
Correct answer: Cause eutrophication, algal blooms and oxygen depletion in receiving waters
Nitrogen and phosphorus feed algal growth, and when the algae die, decomposition depletes oxygen : the eutrophication cycle. That is why they are regulated in discharges.
Question 12: Hot CIP rinse water discharged to a watercourse can cause:
Correct answer: Thermal pollution, warm water holds less dissolved oxygen and stresses aquatic life
Warm water holds less dissolved oxygen and stresses aquatic life, which is what thermal pollution means. A discharge of hot rinse water therefore carries a real ecological effect.
Question 13: High organic loading discharged to a river harms fish primarily by:
Correct answer: Depleting dissolved oxygen as microbes break down the organic matter
Fish die because microbes consume dissolved oxygen breaking down the organic load, not because of clarity or current. The harm route is oxygen depletion.
Question 14: A BOD/COD ratio above 0.5 in an effluent indicates that it is:
Correct answer: Readily biodegradable and well suited to biological treatment
A BOD/COD ratio above 0.5 means most of the polluting load is biodegradable, so biological treatment will work well. A low ratio would signal resistant or toxic content.
Question 15: Brines from cheese salting and pickle production raise which effluent parameter?
Correct answer: Salinity / total dissolved solids
Brines are concentrated salt solutions, so they raise salinity and total dissolved solids in the effluent. They do not neutralise pH or add oxygen.
Question 16: An acidic effluent at pH 4 discharged without neutralisation would:
Correct answer: Corrode concrete and pipework and inhibit biological treatment
At pH 4 the effluent is acidic enough to corrode concrete and pipework and to inhibit the biology of downstream treatment. Discharge without neutralisation damages both infrastructure and treatment performance.
Question 17: For the same effluent sample, how do COD and BOD normally compare?
Correct answer: COD is equal to or higher than BOD
COD captures everything oxidisable including the non-biodegradable fraction, so it is equal to or higher than BOD, which covers only the biodegradable part. BOD can never exceed the total COD represents.
Question 18: What is the main purpose of an equalisation (balancing) tank in effluent management?
Correct answer: To even out flow and pollutant load so downstream treatment receives a steady feed
An equalisation tank evens out flow and pollutant spikes so downstream treatment receives a steady feed instead of shock loads. It balances, not heats or stores product.
Question 19: Dairy processing effluent is typically characterised by:
Correct answer: High BOD, often exceeding 1,000 mg/L, from milk residues and whey
Dairy effluent carries milk residues and whey, giving it high BOD that often exceeds 1,000 mg/L. Zero solids or very low strength would contradict that composition.
Question 20: Discharging trade effluent to the public sewer normally requires:
Correct answer: A trade effluent consent from the sewerage undertaker, often with pre-treatment conditions
Discharge to the public sewer needs a trade effluent consent from the sewerage undertaker, usually with pre-treatment conditions. Verbal agreements and no-permission options have no legal standing.