Activated Sludge Quiz
GIFSQ ID: ART-2016
Test your knowledge with this free 20-question Activated Sludge quiz from Water, Wastewater & Effluent Treatment in Food…
What this quiz covers
Activated sludge is suspended growth aerobic treatment: microbes in aeration tanks break down waste, then clarifiers separate the biomass from the treated water. The quiz works through the operating ideas: nitrification, and why effluent ammonia rises when nitrifiers are lost through low sludge age, cold weather, toxicity, or low dissolved oxygen; the solids balance, mixed liquor suspended solids, sludge age, return activated sludge, waste activated sludge, and how the wasting rate sets sludge age; and the process variants and tools, step feed, contact stabilization, anoxic selectors, biological phosphorus removal, simultaneous nitrification and denitrification, oxygen uptake rate, and fine bubble diffusers.
The second half is about reading the plant: operators check floc structure, filament abundance, and protozoa diversity under the microscope, and stalked ciliates point to a mature, stable biomass that clarifies well. Foaming from filamentous organisms such as Nocardia, and sludge bulking, signal a shift in the balance. Cold weather slows biological rates, so plants may raise mixed liquor solids or sludge age to compensate. Aeration stays the biggest energy cost, because blowers run continuously to supply oxygen for the full organic load plus mixing.
Watch the biology, not just the numbers
A lab result tells you what happened; the microscope often tells you what is about to happen: a sudden drop in mixed liquor solids suggests washout or toxic shock, and a shift in protozoa shows stress before effluent quality falls. That is why the quiz pairs the control levers, wasting rate and aeration, with the living indicators, flocs, filaments, and ciliates.
How to use this quiz
Take the quiz cold first, then read the short note below the player. It covers activated sludge treatment, in plain words. If you work in wastewater treatment, compare each answer with your own plant: the wasting rate, the foam, and the microscope picture you check each week.
Choose how you want to play
A short note: activated sludge treatment
Activated sludge is a suspended-growth aerobic wastewater treatment process in which microbes in an aeration tank consume dissolved organic waste, and a secondary clarifier then settles the biomass so most of it returns as return activated sludge, or RAS.
Air is the working input. Blowers feed oxygen through fine-bubble diffusers while microbes turn organic matter into carbon dioxide, water, and new biomass. Aeration is the largest energy cost in the plant, so operators hold dissolved oxygen near 2 mg/L, enough for the biology without wasting blower power. The food-to-microorganism ratio sets the load per unit of biomass, and Metcalf and Eddy give 0.2 to 0.4 per day for conventional plants.
Sludge age, or SRT, is the master control. Operators set it by how much they waste: more wasting shortens SRT, less wasting lengthens it. Conventional plants run about 5 to 15 days. Slow-growing nitrifiers need 8 to 10 days, so a short sludge age, cold water, low oxygen, or a toxic shock can wash them out and send effluent ammonia climbing.
Operators also watch sludge under a microscope. Firm flocs, few filaments, and stalked ciliates point to mature, stable biomass, while fluffy bulking sludge warns of washout. A sludge volume index below about 150 mL/g signals good settling. When food runs out, biomass consumes itself in endogenous respiration, which stabilizes sludge at long sludge ages.
Check MLSS, sludge age, and dissolved oxygen daily: if ammonia climbs, check sludge age, temperature, and oxygen first.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: What is a common cause of rising effluent ammonia in activated sludge?
Correct answer: Loss of nitrifiers from low SRT, cold, toxicity, or low DO
Rising effluent ammonia usually means nitrifiers have been lost : from low SRT, cold weather, toxicity, or low dissolved oxygen.
Question 2: What does a sudden drop in MLSS suggest?
Correct answer: Biomass washout or toxic shock killing/inhibiting the culture
A sudden drop in MLSS suggests biomass washout or a toxic shock that killed or inhibited the culture.
Question 3: Why is step-feed used in activated sludge?
Correct answer: Splitting influent across the tank evens the load and improves shock tolerance
Step-feed splits influent across the tank, evening out the load and improving tolerance to shock loads.
Question 4: What is foaming in activated sludge (e.g., Nocardia foam)?
Correct answer: Stable brown foam from filamentous organisms or surfactants that can overflow tanks
Foaming, such as Nocardia foam, is stable brown foam from filamentous organisms or surfactants that can overflow tanks.
Question 5: Why measure OUR (oxygen uptake rate) in activated sludge?
Correct answer: OUR shows real-time biological activity and load, a fast control signal versus 5-day BOD
OUR shows real-time biological activity and load : a fast control signal, unlike the 5-day BOD test.
Question 6: How does cold weather affect activated sludge?
Correct answer: Biological rates slow, so plants may raise MLSS/SRT to compensate
Cold weather slows biological rates, so plants may raise MLSS or SRT to compensate.
Question 7: Why is phosphorus sometimes removed biologically (EBPR)?
Correct answer: Alternating anaerobic/aerobic zones select phosphorus-accumulating organisms that take up excess P
Biological phosphorus removal alternates anaerobic and aerobic zones to select phosphorus-accumulating organisms that take up excess phosphorus.
Question 8: What is contact stabilization?
Correct answer: A variant where biomass contacts waste briefly, then stabilizes in a separate reaeration tank, good for dilute wastes
Contact stabilization lets biomass contact waste briefly, then stabilizes it in a separate reaeration tank : good for dilute wastes.
Question 9: What is simultaneous nitrification-denitrification?
Correct answer: Both occurring in one tank via oxygen gradients in flocs, ammonia and nitrate removed together
Simultaneous nitrification-denitrification happens in one tank via oxygen gradients inside flocs, so ammonia and nitrate are removed together.
Question 10: How is sludge age controlled in practice?
Correct answer: By the wasting rate: wasting more lowers SRT, wasting less raises it
Sludge age is controlled by the wasting rate: wasting more lowers SRT, wasting less raises it.
Question 11: What is RAS?
Correct answer: Return activated sludge, settled biomass recycled to the aeration tank to maintain MLSS
RAS : return activated sludge : recycles settled biomass to the aeration tank to maintain MLSS.
Question 12: Why add an anoxic selector ahead of the aeration tank?
Correct answer: It favors floc-formers over filaments and enables denitrification, curbing bulking
An anoxic selector ahead of the aeration tank favors floc-formers over filaments and enables denitrification, curbing bulking.
Question 13: What is WAS?
Correct answer: Waste activated sludge, excess biomass withdrawn to control sludge age and MLSS
WAS : waste activated sludge : is excess biomass withdrawn to control sludge age and MLSS.
Question 14: What is the activated sludge process?
Correct answer: Suspended-growth aerobic treatment: biomass in aeration tanks degrades waste, then clarifiers separate it
The activated sludge process is suspended-growth aerobic treatment: biomass in aeration tanks degrades waste, then clarifiers separate it.
Question 15: How do operators check activated sludge health microscopically?
Correct answer: Floc structure, filament abundance, and protozoa diversity indicate process condition
Operators check sludge health microscopically through floc structure, filament abundance, and protozoa diversity : they reveal process condition directly.
Question 16: Why is aeration the biggest energy cost in activated sludge?
Correct answer: Supplying the oxygen for the full BOD load plus mixing runs blowers continuously
Aeration is the biggest energy cost because supplying oxygen for the full BOD load, plus mixing, keeps blowers running continuously.
Question 17: What do stalked ciliates in the mixed liquor indicate?
Correct answer: A mature, stable biomass with good treatment, they graze dispersed bacteria, clarifying effluent
Stalked ciliates in the mixed liquor indicate mature, stable biomass with good treatment : they graze dispersed bacteria and clarify the effluent.
Question 18: What is endogenous respiration?
Correct answer: Biomass consuming itself when substrate runs out, the basis of sludge stabilization at long SRT
Endogenous respiration is biomass consuming itself when substrate runs out : the basis of sludge stabilization at long sludge ages.
Question 19: Why control MLSS in activated sludge?
Correct answer: Biomass must match the load: too little under-treats, too much overloads clarifiers
MLSS must match the load: too little under-treats, too much overloads the clarifiers.
Question 20: What are fine-bubble diffusers?
Correct answer: Membrane or ceramic diffusers making tiny bubbles for oxygen transfer
Fine-bubble diffusers : membrane or ceramic : make tiny bubbles for efficient oxygen transfer.