Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

COD Quiz

GIFSQ ID: ART-2003

Test your knowledge with this free 20-question COD quiz from Water, Wastewater & Effluent Treatment in Food Industry…

What this quiz covers

COD, chemical oxygen demand, measures the oxygen equivalent of organics oxidized by a strong chemical oxidant, the total chemically oxidizable load in the water, and this quiz starts with what that number means. The standard COD test uses potassium dichromate in concentrated sulfuric acid, the strong oxidant that digests nearly all organics, with silver sulfate as the catalyst helping oxidize straight-chain organics and some refractory compounds, and mercuric sulfate added to complex chloride ions that would otherwise be oxidized and inflate the result. The standard COD reflux takes 2 hours, the defined digestion time for the open-reflux method, while COD vials for the spectrophotometric method are sealed pre-dosed vials heated in a block and read by color change, faster and safer than open reflux. COD is always higher than BOD for the same sample because dichromate oxidizes biodegradable plus non-biodegradable organics that microbes cannot touch, and total organic carbon is another rapid aggregate organics measure, roughly proportional to COD, so the two track each other.

The rest of the quiz follows COD through the treatment plant and the laboratory. A low BOD to COD ratio, for example 0.2, suggests significant non-biodegradable or inhibitory content, so biological treatment alone may struggle, and a non-biodegradable chemical discharge, such as a cleaning solvent, raises COD without adding BOD, since microbes cannot oxidize it. Soluble versus total COD tells an operator the split between dissolved and particulate load, guiding whether biological or physical removal dominates. COD is preferred for day-to-day plant control over BOD because results come in hours, letting operators adjust aeration and loading promptly, and the COD-BOD relationship is calibrated per plant because the ratio varies by waste type, and a plant-specific correlation lets COD predict BOD for compliance forecasting. Comparing influent and primary-effluent COD shows how much load physical processes remove before biology, and across a well-run biological plant COD falls sharply as microbes oxidize organics, so effluent COD is a small fraction of the influent. COD correlates with aeration energy demand because oxidizing the COD load biologically is what the blowers work for: COD estimates the oxygen bill. Many jurisdictions set COD limits alongside or instead of BOD as an enforceable effluent standard, COD can be measured online, with COD and TOC analyzers giving near-real-time load data for advanced process control, and COD testing needs acid-resistant handling, fume extraction and careful heating, because hot concentrated sulfuric acid and dichromate are hazardous, while spent vials contain chromium and mercury, hazardous waste needing proper disposal.

One idea runs through the set: COD is the fast number, BOD is the biological number, and the gap between them is the story

When COD and BOD track together, the load is biodegradable. When they split apart, something in the water resists biology, and the plant has to know that before it fails.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the test, the reagents and the plant uses a wastewater student is expected to know by heart.

COD Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: chemical oxygen demand (COD)

Chemical oxygen demand, or COD, is the oxygen equivalent of the organic matter in water that a strong chemical oxidant can oxidize, including matter that microbes cannot break down.

The standard test digests the sample with potassium dichromate in concentrated sulfuric acid at 150 °C for two hours, under Standard Methods 5220 and ISO 15705:2002. Silver sulfate catalyzes the oxidation, and mercuric sulfate ties up chloride that would otherwise inflate the result. Factory-filled vials, warmed in a block and read by color, give the same result faster and more safely.

COD is always equal to or higher than BOD for the same sample, since dichromate oxidizes both the biodegradable share and the resistant share. The BOD to COD ratio therefore reads biodegradability: near 0.6 the waste is readily biodegradable, near 0.2 it carries resistant or inhibitory matter, and a cleaning solvent can raise COD without adding BOD at all.

Speed is why plants run COD daily. Results arrive in hours, so operators can adjust aeration and loading the same shift, while the five-day BOD test serves design and permits. Permits often set COD limits, and online analyzers give near-real-time load data.

COD waste needs care. Hot concentrated acid and dichromate are hazardous in the test, and spent vials hold chromium and mercury, so they go out as hazardous waste.

Use COD for same-day control and BOD for the permit record, and calibrate the COD to BOD ratio for your own waste instead of borrowing another plant's number.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: What does COD measure?

  • A. Dissolved oxygen within properly managed operational routines throughout standardized operational practice
  • B. Bacterial count within properly managed operational routines throughout standardized operational practice
  • C. The oxygen equivalent of organics oxidized by strong chemical oxidant, total chemically oxidizable load
  • D. Biological activity within properly managed operational routines throughout standardized operational practice

Correct answer: The oxygen equivalent of organics oxidized by strong chemical oxidant, total chemically oxidizable load

COD measures the oxygen equivalent of organics oxidized by a strong chemical oxidant: the total chemically oxidizable load in the water.

Question 2: How does COD help evaluate primary treatment?

  • A. Comparing influent and primary-effluent COD shows how much load physical processes remove before biology
  • B. Only TSS matters in the course of routine site work throughout standardized operational practice
  • C. Primary has no effect as part of standard daily routines within properly managed operational routines
  • D. It doesn't as a normal part of the working day throughout standardized operational practice

Correct answer: Comparing influent and primary-effluent COD shows how much load physical processes remove before biology

COD helps evaluate primary treatment because comparing influent and primary-effluent COD shows how much load physical processes remove before biology.

Question 3: How does total organic carbon (TOC) relate to COD?

  • A. Total organic carbon, another rapid aggregate organics measure, roughly proportional to COD
  • B. Total oxygen content as a normal part of the working day
  • C. A pathogen as a normal part of the working day throughout standardized operational practice
  • D. A filter as a normal part of the working day throughout standardized operational practice

Correct answer: Total organic carbon, another rapid aggregate organics measure, roughly proportional to COD

Total organic carbon is another rapid aggregate organics measure, and it is roughly proportional to COD, so the two track each other.

Question 4: What does a low BOD:COD ratio (e.g., 0.2) suggest?

  • A. Pure water as part of standard daily routines under normal conditions
  • B. Significant non-biodegradable or inhibitory content, biological treatment alone may struggle
  • C. It is ideal across normal supervised working activities
  • D. High biodegradability in the course of routine site work

Correct answer: Significant non-biodegradable or inhibitory content, biological treatment alone may struggle

A low BOD to COD ratio, for example 0.2, suggests significant non-biodegradable or inhibitory content, so biological treatment alone may struggle.

Question 5: What safety precautions apply in COD testing?

  • A. Gloves only within properly managed operational routines across normal supervised working activities
  • B. None within properly managed operational routines as a normal part of the working day
  • C. It is safe within properly managed operational routines throughout standardized operational practice
  • D. Acid-resistant handling, fume extraction, and careful heating, hot concentrated sulfuric acid and dichromate are hazardous

Correct answer: Acid-resistant handling, fume extraction, and careful heating, hot concentrated sulfuric acid and dichromate are hazardous

COD testing needs acid-resistant handling, fume extraction, and careful heating, because hot concentrated sulfuric acid and dichromate are hazardous.

Question 6: Why is COD preferred for day-to-day plant control over BOD?

  • A. BOD is banned across normal supervised working activities
  • B. It is more accurate biologically within properly managed operational routines
  • C. Results in hours let operators adjust aeration and loading promptly
  • D. It is cheaper always throughout standardized operational practice

Correct answer: Results in hours let operators adjust aeration and loading promptly

COD is preferred for day-to-day plant control over BOD because results come in hours, letting operators adjust aeration and loading promptly.

Question 7: How is COD used in discharge permits?

  • A. Only BOD is legal as a normal part of the working day within properly managed operational routines
  • B. It isn't as a normal part of the working day within properly managed operational routines
  • C. Many jurisdictions set COD limits alongside/instead of BOD as an enforceable effluent standard
  • D. COD is advisory as a normal part of the working day throughout standardized operational practice

Correct answer: Many jurisdictions set COD limits alongside/instead of BOD as an enforceable effluent standard

COD is used in discharge permits because many jurisdictions set COD limits alongside or instead of BOD as an enforceable effluent standard.

Question 8: What happens to COD across a well-run biological plant?

  • A. It rises throughout standardized operational practice within properly managed operational routines
  • B. It stays constant as a normal part of the working day throughout standardized operational practice
  • C. It becomes BOD as a normal part of the working day throughout standardized operational practice
  • D. It falls sharply as microbes oxidize organics, effluent COD a small fraction of influent

Correct answer: It falls sharply as microbes oxidize organics, effluent COD a small fraction of influent

Across a well-run biological plant, COD falls sharply as microbes oxidize organics, so effluent COD is a small fraction of the influent.

Question 9: Can COD be measured online?

  • A. No as a normal part of the working day under normal conditions
  • B. Yes, online COD/TOC analyzers give near-real-time load data for advanced control
  • C. It is forbidden in the course of routine site work
  • D. Only in labs as part of standard daily routines

Correct answer: Yes, online COD/TOC analyzers give near-real-time load data for advanced control

COD can be measured online: COD and TOC analyzers give near-real-time load data for advanced process control.

Question 10: Which oxidant is used in the standard COD test?

  • A. Chlorine across normal supervised working activities
  • B. Hydrogen peroxide across normal supervised working activities
  • C. Ozone throughout standardized operational practice
  • D. Potassium dichromate in concentrated sulfuric acid

Correct answer: Potassium dichromate in concentrated sulfuric acid

The standard COD test uses potassium dichromate in concentrated sulfuric acid, the strong oxidant that digests nearly all organics.

Question 11: Why is mercuric sulfate added in COD testing?

  • A. It is decorative in the course of routine site work
  • B. To speed cooling in the course of routine site work
  • C. To add mercury pollution as a normal part of the working day
  • D. To complex chloride ions that would otherwise be oxidized and inflate the result

Correct answer: To complex chloride ions that would otherwise be oxidized and inflate the result

Mercuric sulfate is added in COD testing to complex chloride ions, which would otherwise be oxidized and inflate the result.

Question 12: Why calibrate the COD, BOD relationship for a specific plant?

  • A. It is required daily as a normal part of the working day throughout standardized operational practice
  • B. The ratio varies by waste type; a plant-specific correlation lets COD predict BOD for compliance forecasting
  • C. It is universal throughout standardized operational practice within properly managed operational routines
  • D. Ratios never change within properly managed operational routines throughout standardized operational practice

Correct answer: The ratio varies by waste type; a plant-specific correlation lets COD predict BOD for compliance forecasting

The COD-BOD relationship is calibrated per plant because the ratio varies by waste type, and a plant-specific correlation lets COD predict BOD for compliance forecasting.

Question 13: Why is COD always higher than BOD for the same sample?

  • A. BOD is wrong within properly managed operational routines
  • B. Dichromate oxidizes biodegradable plus non-biodegradable organics that microbes can't touch
  • C. It isn't as a normal part of the working day
  • D. COD is estimated within properly managed operational routines

Correct answer: Dichromate oxidizes biodegradable plus non-biodegradable organics that microbes can't touch

COD is always higher than BOD for the same sample because dichromate oxidizes biodegradable plus non-biodegradable organics that microbes cannot touch.

Question 14: Why must COD waste be handled carefully?

  • A. It is harmless as a normal part of the working day
  • B. It explodes in the course of routine site work
  • C. It is radioactive as a normal part of the working day
  • D. Spent vials contain chromium and mercury, hazardous waste needing proper disposal

Correct answer: Spent vials contain chromium and mercury, hazardous waste needing proper disposal

COD waste must be handled carefully because spent vials contain chromium and mercury, hazardous waste needing proper disposal.

Question 15: What is the role of silver sulfate in the COD test?

  • A. Catalyst helping oxidize straight-chain organics and some refractory compounds
  • B. It is optional throughout standardized operational practice
  • C. It reduces COD across normal supervised working activities
  • D. It is a color throughout standardized operational practice

Correct answer: Catalyst helping oxidize straight-chain organics and some refractory compounds

Silver sulfate acts as the catalyst in the COD test, helping oxidize straight-chain organics and some refractory compounds.

Question 16: How does a non-biodegradable chemical discharge (e.g., a cleaning solvent) affect COD and BOD?

  • A. BOD is wrong in the course of routine site work throughout standardized operational practice
  • B. A non-biodegradable chemical discharge (e.g., cleaning solvent) raises COD without adding BOD
  • C. Impossible as a normal part of the working day within properly managed operational routines
  • D. COD is broken in the course of routine site work within properly managed operational routines

Correct answer: A non-biodegradable chemical discharge (e.g., cleaning solvent) raises COD without adding BOD

A non-biodegradable chemical discharge, such as a cleaning solvent, raises COD without adding BOD, since microbes cannot oxidize it.

Question 17: What does soluble vs total COD tell an operator?

  • A. The split between dissolved and particulate load guides whether biological or physical removal dominates
  • B. Only total matters as a normal part of the working day under normal conditions
  • C. Nothing within properly managed operational routines throughout standardized operational practice
  • D. They are equal as a normal part of the working day under normal conditions

Correct answer: The split between dissolved and particulate load guides whether biological or physical removal dominates

Soluble versus total COD tells an operator the split between dissolved and particulate load, guiding whether biological or physical removal dominates.

Question 18: How long does the standard COD reflux take?

  • A. 2 hours
  • B. 5 days
  • C. 2 minutes
  • D. 2 weeks

Correct answer: 2 hours

The standard COD reflux takes 2 hours, the defined digestion time for the open-reflux method.

Question 19: Why does COD correlate with aeration energy demand?

  • A. Blowers ignore load across normal supervised working activities within properly managed operational routines
  • B. It doesn't within properly managed operational routines as a normal part of the working day
  • C. Oxidizing the COD load biologically is what the blowers work for, COD estimates the oxygen bill
  • D. COD is electrical across normal supervised working activities within properly managed operational routines

Correct answer: Oxidizing the COD load biologically is what the blowers work for, COD estimates the oxygen bill

COD correlates with aeration energy demand because oxidizing the COD load biologically is what the blowers work for: COD estimates the oxygen bill.

Question 20: What are COD vials (spectrophotometric method)?

  • A. For BOD only throughout standardized operational practice as a normal part of the working day
  • B. Drinking glasses throughout standardized operational practice as a normal part of the working day
  • C. Sealed pre-dosed vials heated in a block and read by color change, faster and safer than open reflux
  • D. A brand name throughout standardized operational practice as a normal part of the working day

Correct answer: Sealed pre-dosed vials heated in a block and read by color change, faster and safer than open reflux

COD vials for the spectrophotometric method are sealed pre-dosed vials heated in a block and read by color change, faster and safer than open reflux.