Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Food Engineering Part 33 Quiz

GIFSQ ID: ART-1110

Test your knowledge with this free 20-question Food Engineering quiz (Part 33). Choose the correct answer for each…

What this quiz covers

Evaporators open the set: a centrifugal catchall in the vapour line spins out entrained droplets and particles, and the circulation type is chosen mainly on viscosity, with thin liquids circulating naturally and thick ones needing a pump. In natural-circulation evaporators the liquid enters the tubes at 30 to 90 cm/s, long tubes run 3 to 10 m, and a forced-circulation evaporator gains its heat transfer coefficient from higher liquid velocity. Raising the vacuum lowers the boiling point and widens the available temperature difference, while the total boiling-point rise is what limits how many effects a multiple-effect system can have.

Drum drying takes the middle: heat transfer controls the process, the drums are steel, 60 to 120 cm across, and the milk film touches the hot metal for 3 seconds or less before the blade scrapes it off. The gap between twin drums is 0.5 to 1.0 mm, the preheat for milk is capped at 71 °C, and a faster drum spreads a thinner film and raises thermal efficiency. In the falling-rate period the surface is no longer saturated, so moisture must diffuse out from inside before it can evaporate, and air is used best with a hot inlet and a cool outlet.

The units of transport properties

The quiz closes on units: specific volume is m³/kg, the reciprocal of density; viscosity can be written in poise, pascal-seconds or kg·m⁻¹·s⁻¹; thermal conductivity is W/m·K; mass diffusivity is m²/s; and mass flux works in kg/s·m² or on a molar basis. A mixer at 120 rpm turns at 2 s⁻¹, a fluid of 2.5 g/mL is 2500 kg/m³, heat flow is Btu/h, and the one wrong unit for the convective coefficient is Btu/ft³·h·°C, which has volume where area belongs.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the correct choice in plain words, so a miss becomes a fact you keep. The traps are the drum numbers: 60 to 120 cm diameter against a 0.5 to 1.0 mm gap, and 71 °C preheat against 3 seconds of contact, so keep each number with its own part before retaking.

Food Engineering Part 33 Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

Answer explanations

Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.

  1. A centrifugal catchall in the vapor line of an evaporator is used to:
    1. Control vapor flow
    2. Remove entrained particles (correct answer)
    3. Trap non-condensable gases
    4. None of these

    Correct answer: Remove entrained particles. A centrifugal catchall (cyclone separator) in the vapour line of an evaporator spins the vapour so that entrained liquid droplets and solid particles are thrown to the wall and drained back, letting clean vapour pass to the condenser (McCabe & Smith, Unit Operations of Chemical Engineering). Entrainment carries dissolved solids into the condensate and causes product loss, so removing the entrained particles is the catchall's purpose. It does not meter vapour flow or trap non-condensable gases.
  2. In drum drying, the controlling factor is:
    1. Heat transfer (correct answer)
    2. Diffusion
    3. Both
    4. Neither

    Correct answer: Heat transfer. Drum drying is controlled by heat transfer: the thin feed film is heated by conduction through the drum wall, and the drying rate is set by how fast heat reaches the film. That is why steam pressure and drum speed — which set the drum-wall temperature and the film thickness — govern a drum drier's output. Diffusion inside the film is not the limiting step because the film is very thin.
  3. In a roller drier, the average drum diameter is:
    1. 60–120 cm (correct answer)
    2. 10–50 cm
    3. 200–300 cm
    4. 300–400 cm

    Correct answer: 60–120 cm. Roller (drum) drier drums are typically 0.6–1.2 m in diameter and up to about 3.6 m long, with the gap between twin drums adjustable for film thickness (dairy processing equipment texts; agriculture.institute roller-drier course). The 60–120 cm range is the standard industrial size for food drum dryers. Larger diameters appear only in special or chemical-industry designs.
  4. The material used to build a drum drier is
    1. Steel (correct answer)
    2. Copper
    3. Aluminum
    4. Iron

    Correct answer: Steel. Drum driers are built as hollow steel drums with smoothly polished external surfaces (standard dairy and pharmaceutical equipment descriptions). Steel withstands the internal steam pressure and gives a true surface for the doctor blade to scrape. Copper, aluminium, and plain iron are not used for this duty.
  5. What goes on during the falling-rate period of drying?
    1. Moisture moving from inside the material to its surface
    2. Moisture evaporating off the surface
    3. Both of the above (correct answer)
    4. Neither of the above

    Correct answer: Both of the above. During the falling-rate period the surface is no longer saturated, so drying is governed by moisture diffusing from inside the material to the surface, where it then evaporates. Both steps operate at once: internal diffusion feeds moisture to the surface, and surface evaporation removes it. That is why the drying rate keeps falling as the material dries out.
  6. The thermal efficiency of air use in a drier is improved by:
    1. High inlet air temperature with low outlet air temperature
    2. Efficient heat exchange for heating the air
    3. Both of the above (correct answer)
    4. Neither of the above

    Correct answer: Both of the above. The thermal efficiency of air use in a dryer rises when the inlet air is hot and the exhaust air is as cool as possible, because more of the air's heat is then spent evaporating water before it leaves. Efficient heat exchange for heating the inlet air also cuts the heat that must be supplied. Both measures raise the fraction of supplied heat that does useful drying.
  7. Atomizers are used in:
    1. Drum driers
    2. Spray driers (correct answer)
    3. Freeze driers
    4. All of the above

    Correct answer: Spray driers. Atomizers — pressure nozzles, rotary discs, or two-fluid nozzles — are the feed devices of spray dryers; they shatter the feed into fine droplets that dry in the hot air stream. Drum dryers spread a film mechanically and freeze dryers sublimate ice; neither uses an atomizer. The atomizer is therefore the hallmark of the spray dryer.
  8. The contact time between the milk solids and the hot metal in a roller drier is:
    1. 3 seconds or less (correct answer)
    2. 4 seconds
    3. 5 seconds
    4. 6 seconds

    Correct answer: 3 seconds or less. On a roller (drum) drier the thin milk film is dried and scraped off within about 3 seconds of contact with the hot metal (dairy processing texts). This very short contact time is what lets heat-sensitive milk be dried on a drum heated internally by pressurized steam. Longer contact would scorch the milk solids.
  9. The gap between the drums in a drum drier is:
    1. 0.1–0.4 mm
    2. 0.5–1.0 mm (correct answer)
    3. 1.5–2.0 mm
    4. 2.0–3.0 mm

    Correct answer: 0.5–1.0 mm. In a double-drum drier the two drums run with a gap of roughly 0.5–0.75 mm, set by the adjustable bearing of the movable drum (agriculture.institute roller-drier course). The gap fixes the film thickness applied to the drums and hence the drying rate. The 0.5–1.0 mm option covers this operating range.
  10. The highest allowable preheat temperature for milk before drying is:
    1. 71 °C (correct answer)
    2. 81 °C
    3. 91 °C
    4. 40 °C

    Correct answer: 71 °C. Preheating milk before drying cuts the dryer's heat load and thins the feed, but the preheat must stay below temperatures that cause heavy whey-protein denaturation and feed-equipment fouling; the value used here is 71 °C. For scale, HTST pasteurization holds milk at 71.7 °C for 15 s (FDA Pasteurized Milk Ordinance), so 71 °C sits at the familiar pasteurization threshold. Note this ceiling is reference-specific — high-heat powder manufacture uses hotter preheats
  11. Which change raises a drum drier's overall thermal efficiency?
    1. Drum speed (correct answer)
    2. Thicker product film
    3. Both
    4. Neither

    Correct answer: Drum speed. Drum speed sets the film thickness and the contact time on a roller drier: a faster drum spreads a thinner film and raises the evaporation rate per unit drum area, so more of the steam's heat goes into evaporation rather than being lost — the standard way drum-drier throughput and heat utilization are raised in dairy processing texts. That is why drum speed is named as the factor raising overall thermal efficiency.
  12. Specific volume is measured in which units?
    1. m³/kg (correct answer)
    2. kJ/kg
    3. kJ/kg·K
    4. None of these

    Correct answer: m³/kg. Specific volume is volume per unit mass, v = V/m, with SI units m³/kg — it is the reciprocal of density. kJ/kg is specific energy and kJ/kg·K is specific heat capacity, so neither can be specific volume. m³/kg is the only correct unit.
  13. Viscosity can be expressed in
    1. Poise
    2. Pa·s
    3. kg·m⁻¹·s⁻¹
    4. All of these units (correct answer)

    Correct answer: All of these units. Dynamic viscosity is reported in poise (CGS; 1 P = 0.1 Pa·s), in pascal-seconds (SI), and dimensionally as kg·m⁻¹·s⁻¹ — three expressions of the same quantity. All three are therefore valid viscosity units, so 'All of these units' is correct.
  14. Thermal conductivity is measured in
    1. W/m²·K
    2. W/m·K (correct answer)
    3. J/m²·K
    4. J/m·K

    Correct answer: W/m·K. Thermal conductivity k links heat flux to the temperature gradient (Fourier's law, q = −k·dT/dx), giving units of watts per metre per kelvin, W/m·K. W/m²·K is the convective heat transfer coefficient, which includes area but no conduction path length.
  15. Mass diffusivity is expressed in units of
    1. m/s
    2. kg/m·s
    3. m²/s (correct answer)
    4. 1/s

    Correct answer: m²/s. Mass diffusivity D (Fick's law) has units of area per time, m²/s — the same dimensions as kinematic viscosity and thermal diffusivity. That shared dimensionality is why the three transport properties are grouped in dimensionless numbers such as the Schmidt and Prandtl numbers.
  16. A mixer turning at 120 rpm is rotating at what speed in SI units?
    1. 2 s⁻¹ (correct answer)
    2. 60 min⁻¹
    3. 12 s⁻¹
    4. 10 s⁻¹

    Correct answer: 2 s⁻¹. 120 rpm means 120 revolutions per minute, which is 2 revolutions per second. In SI the unit of rotational frequency is reciprocal seconds, so the mixer turns at 2 s⁻¹. The 60 min⁻¹ option is just 120 rpm renamed, not SI.
  17. A fluid with a density of 2.5 g/mL has what density in SI units?
    1. 0.25 kg/m³
    2. 25 kg/m³
    3. 250 kg/m³
    4. 2500 kg/m³ (correct answer)

    Correct answer: 2500 kg/m³. 2.5 g/mL equals 2.5 g/cm³, and 1 g/cm³ = 1000 kg/m³. Multiplying gives 2.5 × 1000 = 2500 kg/m³. The smaller options miss powers of ten in the conversion.
  18. Heat flow is measured in
    1. Btu/h (correct answer)
    2. h/Btu
    3. Btu·h
    4. 1/Btu·h

    Correct answer: Btu/h. Heat flow is a rate of energy transfer — energy per unit time — so in English engineering units it is Btu/h. h/Btu and 1/Btu·h are reciprocals of a rate, and Btu·h is energy multiplied by time, so none of them is a heat flow.
  19. Mass flux can be written in which units?
    1. kg/s·m²
    2. kg-mol/s·m²
    3. Either of these (correct answer)
    4. Neither of these

    Correct answer: Either of these. Mass flux is mass crossing unit area per unit time, written kg/s·m²; on a molar basis the same flux is kg-mol/s·m². Both are correct forms of the same quantity, so 'Either of these' is right.
  20. The convective heat transfer coefficient can be expressed in all of these units but one — which one?
    1. W/m²·K
    2. kW/m²·K
    3. Btu/ft³·h·°C (correct answer)
    4. kcal/m²·h·°C

    Correct answer: Btu/ft³·h·°C. The convective heat transfer coefficient h = q/(A·ΔT) carries units of energy per (area · time · temperature): W/m²·K, kW/m²·K, and kcal/m²·h·°C are all valid. Btu/ft³·h·°C wrongly puts a volume (ft³) where an area belongs, so it cannot be a convective coefficient.