Unit 8: Practical Laboratory Guide: Testing Food Microbes Hands On
GIFSQ ID: FTN-0147
Unit 8 of 11 in Food Microbiology. This page is one unit of the Food Microbiology notes.
All units in Food Microbiology:
- Unit 1: Microorganisms in Food: Sources and Factors
- Unit 2: Food Contamination and Spoilage
- Unit 3: Analytical Techniques in Food Microbiology
- Unit 4: Food-borne Illness, Food Poisoning and Disease
- Unit 5: Sanitation, Food Safety Management and Regulations
- Unit 6: Starter Cultures and Genetic Importance
- Unit 7: Beneficial Use of Microorganisms in Food: Probiotics, Bacteriocins, Nutraceuticals
- Unit 8: Practical Laboratory Guide: Testing Food Microbes Hands On
- Unit 9: Pests and Physical Factors in Food Spoilage
- Unit 10: Fermentation in Food: Types, Foods, and Changes
- Unit 11: Controlling Microbes in Food: Keeping Them Out, Removing Them, and Destroying Them
Previous unit: Unit 7: Beneficial Use of Microorganisms in Food: Probiotics, Bacteriocins, Nutraceuticals | Next unit: Unit 9: Pests and Physical Factors in Food Spoilage
Unit 8: Practical Laboratory Guide: Testing Food Microbes Hands On
Note
A curiosity opener
Reading about microbes is one thing, and seeing them work is another. A tube of milk that loses its blue colour in an hour tells you more about its microbial load than a page of numbers. A plate with a clear ring around a spice extract shows antimicrobial action you can measure with a ruler. A yogurt sample that grows rods under the microscope shows the starter you have been reading about since Unit 6. This unit turns the practicals from the syllabus into step-by-step guides, so each test can be run, read, and judged in a teaching lab. Every practical here uses the ideas of the earlier units: growth factors from Unit 1, spoilage from Unit 2, counting from Unit 3, pathogens from Unit 4, hygiene from Unit 5, and starters from Units 6 and 7.
Questions to think about
Why does a practical need a control, and what happens without one?
A control shows what the test looks like when nothing is acting on it, so the result can be judged against it. Without a control, a worker cannot tell whether a clear zone came from the spice, the plate, or a mistake in the method.
Why are most practicals read by comparison, not by an absolute number?
Microbial numbers vary with temperature, medium, and time, so a single number means little on its own. Comparing a treated sample with an untreated control, or a sample with a standard, turns a number into a judgement.
What can a practical prove, and what can it never prove?
A practical can show that microbes grew, that a count was high, or that a treatment slowed growth under the test conditions. It can never prove a food is fully safe, because a test covers only the sample tested, down to its detection limit.
8.1 Safety and aseptic basics for every practical
Every practical in this unit starts the same way. Wear a lab coat, tie back hair, wash hands with soap, and work on a clean bench wiped with disinfectant. Never eat, drink, or touch your face in the lab. Sterile tools, media, and containers are opened only as far as needed and closed at once, and hands and tools are kept away from the open mouth of a tube or the surface of a plate. A flame is used to sterilize a wire loop before and after use, and the loop is cooled before it touches a culture, or it will kill the cells it should pick up.
Waste is sorted at the bench: used plates, tubes, and swabs go into a marked biohazard container for autoclaving, never into an ordinary bin, and spills are covered with disinfectant, left for the contact time, and wiped up with paper that also goes into the biohazard container. Hands are washed again before leaving. These habits are not decoration: they protect the worker, they protect the next user of the bench, and they protect the result, because a contaminated plate tells a lie about the food it was meant to test.
Quick self-check: A loop is flamed and used at once, while still glowing. What goes wrong?
The hot loop kills the cells it touches, so nothing grows and the worker concludes the sample was sterile. The loop must cool for a few seconds in the air before it picks up a culture.
8.2 Milk tests: methylene blue reduction and phosphatase
The methylene blue reduction test, or MBRT, judges milk by how fast its microbes remove the blue colour from the milk. Methylene blue is added to a tube of milk, the tube is kept warm, and the time for the blue colour to vanish is recorded. Microbes use up oxygen as they grow, and the dye loses its colour when the oxygen is gone, so a heavy microbial load clears the colour fast and a light load clears it slowly. A milk that holds its colour for hours carries few active microbes, while a milk that clears in under an hour carries a heavy load. The reading is a time, not a count, and it is compared with a standard scale for the milk being tested.
The phosphatase test checks whether milk was properly pasteurized. Raw milk carries the enzyme phosphatase, and pasteurization destroys it. A reagent is added to the milk sample, and if phosphatase is still active, it frees a compound that turns the reagent a blue colour. A blue result means the milk was underpasteurized or raw milk was added after pasteurization, while no colour change means the enzyme was destroyed and the heat process worked. The test is fast and sensitive, which is why it is used as a routine check on pasteurized milk.
Quick self-check: Two milk samples clear MBRT in 30 minutes and in 5 hours. Which carries the heavier microbial load, and why?
The 30-minute sample carries the heavier load: its microbes used up the oxygen fast, so the dye lost its colour fast. The 5-hour sample carries few active microbes, so the colour held for hours.
Quick self-check: A phosphatase test turns blue on a pasteurized milk. What does that mean, and what is the next step?
Phosphatase survived, so the milk was underpasteurized or raw milk entered after heating. The batch is held, the pasteurizer time and temperature are checked, and the test is repeated before the milk is released.
8.3 Water tests: most probable number and membrane filter
Drinking water and plant water are tested by the most probable number, or MPN, method and by the membrane filter, or MF, method, because the numbers that matter in water are small and a plate count would miss them. In the MPN method, measured volumes of the water sample are added to tubes of lactose broth at several dilutions, often 10 ml, 1 ml, and 0.1 ml, five tubes each, and the tubes are incubated. Tubes that turn cloudy and produce gas are counted as positive for coliforms, and the pattern of positive tubes, such as 5-3-1, is read against an MPN table to give the most probable number of coliforms per 100 ml. The result is a statistical estimate, not an exact count, and its precision grows with more tubes.
In the MF method, a measured volume of water, often 100 ml, is passed through a sterile membrane filter that traps the cells, and the filter is laid on a growth medium and incubated. Each trapped cell grows into a colony on the filter, and the colonies are counted directly, giving colonies per 100 ml. The MF method suits clear water with low numbers, because a large volume can be filtered, while the MPN method suits water with particles that would block a filter. Both methods test the same idea from Unit 1: water that touches food must be checked, because it is a primary source of microbes.
Membrane filter test, step by step
↓
↓
↓
Quick self-check: Why filter 100 ml of water instead of plating 1 ml when testing drinking water?
Drinking water should carry very few coliforms, so 1 ml may hold none even when the water is contaminated. Filtering 100 ml gathers the cells from a large volume onto one filter, so even a few cells are caught and counted.
8.4 Isolating Lactobacillus from yogurt
A small amount of plain yogurt is diluted step by step in sterile liquid, and drops of the dilutions are spread on plates of a medium that suits lactic acid bacteria, then incubated warm. Colonies are picked and checked: under the microscope the cells should look like rods, the Gram stain should show Gram-positive rods, and the isolate should make acid in milk, dropping the pH and curdling the milk. A colony that matches all three checks is kept as the isolate.
The isolate is preserved, maintained, and revived as in Unit 6. For short storage it is kept in a fridge in sterile milk or broth for days. For long storage it is mixed with glycerol, which protects the cells from ice damage, and frozen at minus 20 °C or lower, or it is freeze-dried for storage over years. Revival means growing the stored cells in sterile milk at the right temperature and checking that they make acid at the expected rate before they are used. A revived culture that is slow to make acid is treated as weak and replaced from stock.
Quick self-check: A yogurt isolate looks like rods under the microscope but does not make acid in milk. Is it the starter, and what should the worker do?
Probably not the starter, or it is a weak strain: a true lactic starter must make acid in milk. The worker should pick more colonies and test them, and keep only an isolate that passes the shape, stain, and acid checks together.
8.5 What slows growth: pH, ultraviolet light, metals, and spices
Four practicals test what slows or stops microbial growth, and each one changes a single factor while holding the rest steady. In the pH practical, the same microbe is grown in broths set at different pH values, and growth is read by cloudiness after incubation: growth is heavy near neutral pH and fades as acid rises, which shows the pH limit from Unit 1 in action. The control is a broth at neutral pH with the same inoculum and the same incubation.
In the ultraviolet, or UV, practical, plates spread with the same culture are exposed to UV light for different times, with one plate kept in the dark as the control, and all plates are incubated. Fewer colonies grow on the plates exposed longer, because UV damages the DNA of the cells, and the dark control shows how many colonies would have grown without light. The plates must be handled in dim light after exposure, because visible light can help some cells repair UV damage.
In the oligodynamic practical, the effect of heavy metals on microbes is tested by placing clean coins or metal discs of different metals on a spread plate, or by adding tiny amounts of metal salts to the medium, and incubating. A clear zone around a metal shows that the metal slowed or killed the cells near it, and the size of the zone is measured and compared between metals, with a plain disc as the control. The effect comes from metal ions released in tiny amounts, which is why even a small piece of metal can act.
In the spice practical, extracts of spices such as garlic, clove, cinnamon, and mustard are tested the same way: a paper disc soaked in the extract is laid on a spread plate, and the clear zone around it is measured after incubation. A larger zone means stronger antimicrobial action, and the results are compared between spices and against a control disc with no extract. The practical shows why spices were used to keep food before refrigeration, and also why they are not enough on their own: the effect is real but partial, and it weakens when the spice is cooked or diluted in food.
Quick self-check: In the UV practical, why must one plate be kept in the dark, and why must the exposed plates be handled in dim light?
The dark plate is the control, showing growth without UV, so the effect of the light can be measured. Dim handling matters because visible light can help some cells repair UV damage, which would hide the effect being tested.
Quick self-check: A spice extract makes a large clear zone on a plate but the spiced food still spoils. What explains the gap?
The plate test uses a concentrated extract in direct contact with the cells, while the food dilutes the spice, binds it to fat and protein, and lets microbes grow in pockets the spice never reaches. A plate result guides a choice, it does not guarantee the food.
8.6 Spoiled food, cold-loving microbes, and canned food
In the spoiled food practical, samples of spoiled milk, bread, fruit, and meat are examined and the microbes isolated and counted, matching the spoilage signs to the group that caused them, as in Unit 2: slime and off smells in milk point to bacteria, fuzz on bread points to molds, and fermenting fruit points to yeasts. Dilutions are plated on general and selective media, colonies are counted, and the dominant colony type is identified by shape and stain.
Psychrophiles, the cold-loving microbes, are isolated from frozen samples by plating dilutions and incubating the plates cold, near 0 to 5 °C, for days, because they grow slowly and would be missed at warm incubation. Their colonies show which microbes can spoil chilled and frozen food even in the cold, which is why cold storage slows spoilage instead of stopping it.
Clostridia are enumerated from canned foods by heating the sample first to kill vegetative cells while spores survive, then plating in an oxygen-free medium and incubating warm. Colonies that grow after the heat step came from spores, which is the point of the test: canned food should carry no living spores that can grow. Bacillus cereus is isolated from food samples on a selective medium, and its colonies are checked by shape, spore stain, and growth, matching the organism to cooked rice and starchy foods from Unit 4.
Quick self-check: Why heat the canned food sample before plating for Clostridia?
Heating kills the vegetative cells but not the spores, so only spore formers grow on the plate. Without the heat step, other bacteria would crowd the plate and hide the spores that matter for canned food safety.
Quick self-check: Psychrophile plates are incubated cold for days instead of warm overnight. Why?
Psychrophiles grow best in the cold and slowly, so warm incubation would favour other microbes and miss them, and a short incubation would end before their colonies appear.
8.7 Antagonism, synergism, tableware, and soft drinks
Microbial antagonism is shown by cross-streaking: one microbe is streaked in a line on a plate, a second microbe is streaked at right angles to it, and the plate is incubated. If the second microbe stops growing where it nears the first, the first is holding it back, by acid, by a bacteriocin, or by competition, and the clear gap is measured. Synergism is shown the other way: two microbes grown together make acid faster, or grow better, than either does alone, as the two yogurt strains do in Unit 6. The pair is compared with each strain grown alone under the same conditions, and the difference is the evidence.
The tableware practical swabs plates, cups, and utensils after washing, rubs the swab over a plate, and incubates it. The colonies that grow show whether cleaning and sanitizing worked: a clean item gives few or no colonies, while a dirty item gives many. The result is judged against a standard for the item, and a high count means re-cleaning and re-testing, not a quiet note.
The sterility test for soft drinks uses the membrane filter method from section 8.3: a measured volume of the drink, often 100 ml, is filtered, the filter is laid on a medium, and the plate is incubated. Any colonies that grow show the drink was not sterile, and their number and type point to the source: yeasts point to a sugar or flavour fault, bacteria point to water or filling faults. A drink that passes shows no growth on the filter after incubation.
Quick self-check: In the antagonism test, the second microbe grows right up to the first with no gap. What does that show?
No antagonism under those conditions: the first microbe did not hold the second back. It does not prove the first microbe never makes an inhibitor, only that it did not show one in this test.
8.8 Recording results and judging them
Every practical ends the same way: with a record that another worker could follow. The record names the sample, the method, the medium, the temperature, the time, the dilutions, the counts, and the control result. Counts are written as colony forming units per gram or per millilitre, with the dilution and the plate count that produced them, so the calculation from Unit 3 can be checked. A result without its method cannot be checked, and a count without its control cannot be judged.
Judging a result means asking four questions. Did the control behave as expected, so the test itself worked. Was the count in the reliable range, or must the test be repeated at another dilution. Does the result match the food and its history, or does it point to a sampling or lab error. And what action follows: release, hold, re-clean, re-test, or reject. A practical that ends with a number and no judgement has not finished its job, because the number exists to guide an action, and the action is what keeps food safe.
Quick self-check: A plate count reads 8 colonies, and the worker reports a precise number with no warning. What is wrong with that report?
Eight colonies sit below the reliable 30 to 300 range, so chance plays a large part and the number is rough, not precise. The report should note the low count and repeat the test at a lower dilution.
Try it yourself
At home, with no lab, test hand washing the way a tableware test works. Press a clean fingertip lightly onto a slice of bread, then wash your hands with soap and water, dry them, and press a fingertip from the other hand onto a second slice. Seal each slice in a clean bag, label them, and leave both at room temperature for three days. Compare the growth: which slice grows more, and where. Write down what the difference tells you about hand washing, and why this home test can show a difference but cannot name the microbes growing on the bread.
Key ideas to carry forward
- Aseptic basics protect the worker, the bench, and the result: sterile tools, a flame for the loop, and biohazard waste handling.
- MBRT reads milk quality by the time to lose its blue colour, and the phosphatase test shows whether pasteurization worked.
- MPN estimates coliforms in water from tube patterns, and membrane filtration counts them directly from a large volume.
- Lactobacillus is isolated from yogurt by dilution, plating, shape, stain, and acid checks, then preserved frozen with glycerol or freeze-dried.
- pH, UV light, heavy metals, and spice extracts each slow growth, and each test needs a control that holds the factor steady.
- Spoiled food, psychrophiles, canned-food Clostridia, and Bacillus cereus are each isolated by the conditions that suit them, including cold incubation and a heat step for spores.
- Antagonism shows as a clear gap on a cross-streak plate, synergism as better growth together, and tableware and soft drink tests judge cleaning and sterility.
- A result is recorded with its method and its control, and judged by whether the control worked, whether the count is reliable, and what action follows.
Glossary
Methylene blue reduction test (MBRT)
A milk test that judges microbial load by how fast microbes remove the blue colour from the milk. Food tech example: milk that clears MBRT in 30 minutes carries a heavy microbial load.
Phosphatase test
A test for proper pasteurization, based on an enzyme in raw milk that heat destroys. Food tech example: a blue phosphatase result on pasteurized milk means it was underpasteurized.
Oligodynamic effect
The slowing or killing of microbes by tiny amounts of metal ions. Food tech example: a clear zone around a metal disc on a plate shows the oligodynamic effect.
Zone of inhibition
A clear area around a disc or metal where microbes did not grow, measured to judge antimicrobial action. Food tech example: the zone around a garlic extract disc measures its antimicrobial strength.
Psychrophile
A microbe that grows best in the cold, near 0 to 15 °C. Food tech example: psychrophiles isolated from frozen food spoil chilled food even in the cold.
Heat shock
Heating a sample to kill vegetative cells while spores survive, used before plating for spore formers. Food tech example: a heat-shocked canned food sample grows only spore formers on the plate.
Cross-streak
A plate test where two microbes are streaked at right angles to show antagonism. Food tech example: a gap where the second streak stops shows the first microbe held it back.
Membrane filter (MF) method
A method that traps microbes from a large liquid volume on a filter, then grows them on a medium for counting. Food tech example: filtering 100 ml of soft drink tests its sterility.
Control
A sample run alongside the test with the factor under study left out, so the result can be judged. Food tech example: a dark plate is the control in the UV practical.
Aseptic technique
Handling that keeps microbes out of a sample and keeps the worker safe, using sterile tools and a clean bench. Food tech example: flaming a loop before use is part of aseptic technique.
Autoclave
Equipment that sterilizes lab waste and media with steam under pressure. Food tech example: used plates go to the autoclave in a biohazard container, never to an ordinary bin.
Selective medium
A growth medium that lets one group of microbes grow while holding others back. Food tech example: a selective medium picks Bacillus cereus out of a mixed food sample.
References
- William C. Frazier and Dennis C. Westhoff, Food Microbiology, 4th edition.
- James M. Jay, Martin J. Loessner, and David A. Golden, Modern Food Microbiology, 7th edition.
- Frances P. Downes and Keith Ito, Compendium of Methods for the Microbiological Examination of Foods, 4th edition.
- Michael P. Doyle and Larry R. Beuchat, Food Microbiology: Fundamentals and Frontiers, 3rd edition.
- Basanta Rai, Essentials of Industrial Microbiology.
- J. B. Prajapati, I. Sankara Reddy, and V. Sreeja, Starter Cultures and Fermented Milk Products.