Note

A curiosity opener

A factory makes ten thousand yogurt cups a day. Nobody can taste every cup, and tasting cannot find microbes that cause illness without changing flavour. So how does anyone know the batch is safe? The answer is a set of tests that turn invisible microbes into something countable: colonies on a plate, a glow in a tube, a colour change on a strip, or a copied piece of DNA. Each test answers a different question, some count all microbes, some find one named species, and some answer in minutes instead of days. This unit explains how those tests work and when to use each one.

Questions to think about

Why do labs count colonies on a plate instead of looking at cells under a microscope?

One colony on a plate usually grows from one living cell, so counting colonies counts living cells that can grow. A microscope shows dead cells too, and it cannot tell which cells will grow in food.

Why do some tests take days while others answer in minutes?

Growing microbes takes time: a cell must divide many times before it is visible. Fast tests skip the growing step and detect a chemical, a protein, or DNA from the microbes directly, so they answer sooner but need more equipment and cost more per test.

Can a test prove a food has zero microbes?

No. A test can only show that no microbes were found in the sample that was tested, down to the test's detection limit. That is why sampling plans test several samples and why a clear result is read as "not detected", not as absolute zero.

3.1 Sampling: getting a sample that tells the truth

A test is only as good as its sample. Microbes are not spread evenly in food: they cluster on surfaces, in pockets, and in the first and last parts of a batch. A sample taken only from the cleanest corner will lie about the batch.

Good sampling means taking a defined amount, often 25 grams, from several places in the batch, using sterile tools and containers, keeping the sample cold, and testing it quickly before microbes grow or die in transit. Samples for Salmonella testing are usually 25 grams, because the organism may be present in very small numbers and a tiny sample could miss it. Liquid foods are mixed before sampling, solid foods are cut with sterile tools, and surface swabs are used when the surface itself is the question, such as testing a cleaned table or a conveyor belt.

The sample is then mixed with a sterile liquid, often buffered peptone water, in a stomacher or blender that washes microbes off the food without killing them. Dilutions are made step by step, usually tenfold, so that plates receive a countable number of cells: too many cells and colonies merge into a lawn, too few and the count means little. The standard countable range is about 30 to 300 colonies per plate.

Quick self-check: Why take several samples from different parts of a batch instead of one large sample from one place?

Microbes cluster unevenly, so one place can be clean while another carries a heavy load. Several samples from different places give a fairer picture of the whole batch and make it harder for a pocket of contamination to hide.

Quick self-check: Why must a sample stay cold and be tested quickly?

Warmth lets microbes grow in the sample, so the count rises above what was in the food, and long delays let some cells die, so the count falls. Cold storage and fast testing keep the sample close to the food as it was.

3.2 Counting by growing: plate counts and MPN

The plate count is the workhorse of food microbiology. A measured amount of diluted sample is spread on, or mixed into, a growth medium in a petri dish, and the plate is incubated at a set temperature for a set time. Each living cell grows into a visible colony, and the colonies are counted and multiplied by the dilution to give colony forming units per gram or per millilitre (CFU/g or CFU/ml). A total viable count uses a general medium and counts most bacteria that can grow, while selective media pick out one group: violet red bile agar counts coliforms, and other media pick out yeasts and molds, staphylococci, or lactic acid bacteria.

The most probable number (MPN) method is used when numbers are low or the food cannot be plated easily, such as water testing. The sample is added to tubes of broth at several dilutions, and the tubes that turn cloudy or produce gas are counted. A statistical table then gives the most probable number of cells in the original sample. MPN is less precise than a plate count but it finds small numbers and works well for coliform testing in water and milk.

Both methods share a limit: they count only cells that grow on that medium at that temperature in that time. Cells that are injured, slow growing, or need special conditions may not appear, so the count is always an estimate of the living, growing population, not a census of every cell present.

From sample to count

Take 25 g from several places, mix with sterile liquid.

↓

Dilute tenfold, step by step, so plates get a countable load.

↓

Spread on plates, incubate at the set temperature and time.

↓

Count colonies in the 30 to 300 range, multiply by dilution, report CFU/g.
Quick self-check: A plate has 12 colonies and another has 450. Which count is more reliable, and why?

Neither is ideal. Below 30, chance plays a large part and one cell more or less changes the result a lot. Above 300, colonies merge and hide each other, so the count reads low. The 30 to 300 range balances both errors.

3.3 Seeing microbes: microscopy and DEFT

A microscope shows cells directly, including their shape and arrangement: rods, cocci, chains, and clusters. A simple stained smear gives a fast rough count and shows whether the cells look like bacteria, yeasts, or molds, and a Gram stain separates bacteria into Gram-positive (purple) and Gram-negative (pink), which guides the next tests. Microscopy is fast but it counts dead cells as well as living ones, and it needs large numbers, about a million cells per millilitre, before cells are easy to find.

The direct epifluorescent filter technique (DEFT) improves on the plain microscope. The sample is passed through a filter that traps cells, the filter is stained with a fluorescent dye that lights up living cells, and the cells are counted under a fluorescence microscope. DEFT gives a count in about 30 minutes instead of two days, and it is used for raw milk and other liquids. Its weakness is that it counts cells that may not grow on plates, so it reads higher than a plate count when many cells are injured or dead.

Quick self-check: DEFT gives a higher count than a plate count on the same milk. Is one of them wrong?

Not necessarily. DEFT counts living-looking cells whether or not they can grow on a plate, while a plate count counts only cells that grow into colonies. The two methods measure different things, so a gap between them is expected.

3.4 Fast chemical and electrical methods

Some methods skip growing cells and measure what cells do or what they contain. They answer in hours instead of days, which matters when a batch must be released or held.

ATP bioluminescence measures adenosine triphosphate (ATP), the energy molecule in all living cells. A swab picks up residue from a surface, a reagent releases the ATP, and an enzyme from fireflies, luciferase, makes light from it. The light is measured in relative light units: more light means more living cells and food residue. The test answers in under a minute and is used to check cleaning, not to identify species. Its limit is that food residue also contains ATP, so a dirty surface glows even when the microbes are few.

Electrical methods, such as impedance and conductance, measure how microbes change the electrical properties of a medium as they grow. Growing cells break down nutrients into charged products, and the medium's resistance falls. The time taken to reach a set change, called the detection time, is shorter when more cells were present at the start, so detection time can be converted into a count. These methods run many samples at once and suit routine screening of milk and meat.

Quick self-check: An ATP swab glows brightly on a cleaned table. Does that prove living microbes are there?

No. ATP comes from food residue as well as from living cells, so a bright reading may mean leftover food, not living microbes. ATP testing checks cleaning, and a high reading means clean again, then retest.

3.5 Immunological techniques: finding microbes by their surface

Immunological tests use antibodies, which are proteins that bind to one target, such as a protein on the surface of Salmonella. Because the binding is specific, these tests can find one species among many.

In an enzyme-linked immunosorbent assay (ELISA), antibodies fixed to a plate or well catch the target microbe or its toxin from the sample, a second antibody linked to an enzyme binds to it, and the enzyme makes a colour change. The colour shows the target is present, and its strength can estimate how much is there. ELISA is used for toxins such as staphylococcal enterotoxin and for screening large numbers of samples for Salmonella or Listeria.

Immunochromatography puts the same idea on a strip, like a pregnancy test: the sample flows along the strip, and if the target is present, a coloured line appears. It is fast, portable, and needs no large machine, which suits testing at a receiving dock or a small plant.

Agglutination techniques use tiny latex beads coated with antibodies. When the target microbe is present, the beads clump together visibly within minutes. Latex agglutination is used to confirm the identity of a colony already grown on a plate, for example to confirm that a suspect colony is Salmonella or Staphylococcus aureus. These tests are fast and specific, but they usually need the microbe to be grown first to reach detectable numbers, and they rarely give an exact count.

Quick self-check: Why does ELISA need an enrichment step before testing for Salmonella in food?

Salmonella may be present in very small numbers, below what the antibodies can detect, and food parts can block the reaction. Growing the sample in broth first multiplies the cells to a detectable level and dilutes the food parts that interfere.

3.6 Genetic techniques: PCR, NASBA, and hybridization

Genetic tests detect the DNA or RNA of the microbe itself, so they can identify a species with high accuracy and find microbes that are hard to grow.

The polymerase chain reaction (PCR) copies a chosen piece of DNA again and again, doubling it each cycle, until there is enough to detect. A test that starts with a few copies ends with billions after 30 to 40 cycles. Real-time PCR watches the copying as it happens and estimates how much DNA was present at the start. PCR can confirm Salmonella, Listeria, or E. coli O157 in a day instead of several days of culture, and it can detect genes such as toxin genes. Its limits matter: PCR detects DNA from dead cells too, it is sensitive to substances in food that block the reaction, and it needs clean technique, because a tiny speck of stray DNA can be copied into a false positive.

Nucleic acid sequence-based amplification (NASBA) is a similar idea for RNA, and it works at one steady temperature instead of cycling heat. It suits RNA viruses and living cells, since RNA breaks down quickly after a cell dies, so a positive NASBA result points more strongly to living cells than a DNA test does.

Hybridization uses a labelled probe, a short piece of DNA that matches the target's DNA and sticks to it. The probe finds its match in a sample or on a colony, and the label shows where it bound. Hybridization confirms identity and is used in gene probes and in some rapid test kits.

Quick self-check: A PCR test is positive but the plate count is negative. What could explain it?

PCR detects DNA from dead cells, so the microbes may have been killed by heating while their DNA survived. Or the cells may be alive but unable to grow on that plate. The result means the DNA was present, not that living cells were present.

3.7 Biosensors and the choice of method

A biosensor joins a biological detector to a measuring device. The detector may be an antibody, an enzyme, or a piece of DNA fixed to a surface, and when the target binds, the device reports a change in light, electricity, or mass. Biosensors can detect pathogens, toxins, and spoilage chemicals quickly, sometimes in minutes, and some are built into small handheld readers for use in a plant. Their strength is speed and portability, and their weakness is cost, the need for careful calibration, and sensitivity to food parts that interfere.

Choosing a method means matching the question to the tool. A total count answers "how many microbes are growing", a selective count answers "how many of this group", ELISA or a strip answers "is this species or toxin present", and PCR answers "is its DNA here, and which genes does it carry". A plant that must release a batch today uses a fast method and confirms a positive with a culture method, because no single test is fast, cheap, specific, and quantitative all at once. The Compendium of Methods for the Microbiological Examination of Foods gives standard procedures for each of these methods, so results from different labs can be compared.

Choosing the right test

How many microbes grow? Plate count or MPN, days to answer, gives a number.
Is the surface clean? ATP bioluminescence, under a minute, checks cleaning.
Is this species or toxin present? ELISA, strip, or agglutination, hours, specific answer.
Whose DNA is it, and which genes? PCR or NASBA, hours, most precise identity.

Four separate questions, each with its own test: no question leads into the next one.

3.8 Working the numbers: plate counts, PCR copies, and log reductions

A count is only useful when the reader can check how it was worked out, so this section derives the three calculations a food microbiologist uses most, step by step, with worked examples.

Plate count derivation. Start with what the plate shows: C colonies grew on the plate. Each colony came from one colony forming unit in the volume that was plated, written V, in millilitres. The diluted sample therefore held C divided by V colony forming units per millilitre. That diluted sample came from the original food by a dilution factor d, such as 0.001 for a 10 to the power minus 3 dilution, so the original food held more by a factor of 1 divided by d. Put the steps together and the formula is:

CFU per gram or per ml = C divided by (V x d)

Worked example: a plate shows 120 colonies, 0.1 ml was plated, and the dilution was 10 to the power minus 3. Then CFU/g = 120 divided by (0.1 x 0.001) = 120 divided by 0.0001 = 1,200,000, or 1.2 x 10 to the power 6 CFU/g. A second plate from the next dilution should give a similar answer: if it does not, something went wrong in the dilution or the plating, and the test is repeated.

The 30 to 300 rule follows from the same maths. Below 30 colonies, chance dominates: a plate that should show 12 colonies can easily show 8 or 16, because colonies arrive by chance, and the error is roughly the square root of the count, so 12 colonies carries an error of about 3 to 4, or about 30 percent. Above 300 colonies, colonies merge and hide each other, so the count reads low. Between 30 and 300, both errors stay small, which is why plates outside that range are reported with a warning or repeated.

PCR copy derivation. Each PCR cycle doubles the chosen piece of DNA, so after n cycles the copies are the starting copies multiplied by 2 to the power n:

Copies after n cycles = starting copies x 2 to the power n

Worked example: a sample starts with 10 copies of the target DNA. After 30 cycles, copies = 10 x 2 to the power 30 = 10 x 1,073,741,824, which is about 1.1 x 10 to the power 10 copies, enough to detect easily. That is why PCR finds a target that a plate would miss: it multiplies the signal instead of waiting for cells to grow.

Real-time PCR watches the copying as it happens and records the Ct value, the cycle at which the signal crosses a set threshold. A sample with more starting DNA crosses the threshold earlier, so a lower Ct means more target was present at the start. Each difference of about 3.3 cycles means a tenfold difference in starting copies, because 2 to the power 3.3 is about 10. So a sample with Ct 20 held about 10 times as much target DNA as a sample with Ct 23, and about 100 times as much as one with Ct 27. The Ct value is therefore a rough measure of amount, not only a yes or no answer, and a very high Ct near the end of the run must be read with care, because it can come from a tiny speck of stray DNA.

Log reduction derivation. A log reduction compares the count before and after a treatment on the base 10 log scale:

Log reduction = log10 of the starting count minus log10 of the count after treatment

Worked example: heating drops a count from 1,000,000 (log 6) to 1,000 (log 3), so the log reduction is 6 minus 3 = 3 logs, meaning 99.9 percent of cells were killed. A 1-log reduction leaves 10 percent alive, a 2-log reduction leaves 1 percent, and a 5-log reduction leaves 0.001 percent. When a process claims a 5-log kill of a pathogen, it means the count falls a hundred thousandfold, which is the level of safety a heat process is usually designed to reach.

One PCR cycle, repeated 30 to 40 times

Heat to near boiling: the two DNA strands separate.

↓

Cool: short primers stick to their matching spots on each strand.

↓

Warm: the enzyme builds a new strand from each primer, doubling the copies.

Then the cycle repeats: each round doubles the copies made in the last round.

Quick self-check: A plate shows 45 colonies from 1 ml of a 10 to the power minus 4 dilution. What is the count, and is the plate in the reliable range?

CFU/ml = 45 divided by (1 x 0.0001) = 450,000, or 4.5 x 10 to the power 5 CFU/ml. Yes, 45 colonies sits inside the 30 to 300 range, so the count is reliable.

Quick self-check: Two samples give Ct values of 21 and 28 for the same target. Roughly how much more target DNA did the first sample hold?

The gap is 7 cycles. Each 3.3 cycles is about tenfold, so 7 cycles is about two tenfold steps, or about 100-fold more. The first sample held roughly 100 times as much target DNA.

Quick self-check: A wash step claims a 2-log reduction. What percent of cells survive, and why is that not enough on its own for a heavily contaminated food?

Two logs leave 1 percent alive, so 99 percent were removed. On a food starting at 10,000,000 cells, 1 percent is still 100,000 cells, so the wash must be paired with other hurdles such as chilling or heating.

Practical note

Several practicals from the outline belong to this unit. The membrane filter (MF) method for soft drinks traps microbes on a filter laid on a medium, so even a few cells in a large volume are caught and counted, which is the sterility test for drinks. The MPN and MF methods for water count coliforms in drinking water, where small numbers matter. The PCR practical demonstrates copying bacterial DNA to identify a species, and the methylene blue reduction test (MBRT) for milk measures how fast microbes remove the blue colour from milk: a fast loss of colour means a heavy microbial load.

Try it yourself

Take two plates of plain gelatin dessert or two small tubs of plain yogurt as your "growth medium" stand-in, and swab two surfaces at home with clean cotton buds: a kitchen counter before cleaning and the same counter after cleaning with soap and water. Rub each swab over one plate, cover, and leave both at room temperature for two days. Compare the growth: how many spots appear on each, and how big are they? Write down what the difference tells you about cleaning, and why a plate count of this kind cannot name the species growing on it.

Key ideas to carry forward

  • Sampling decides the value of every test: several samples, sterile tools, cold transport, fast testing.
  • Plate counts and MPN count living cells that grow, with 30 to 300 colonies per plate as the reliable range.
  • Microscopy and DEFT show cells directly and answer fast, but they count dead cells too.
  • ATP bioluminescence and electrical methods answer in minutes to hours and suit cleaning checks and screening.
  • Immunological tests (ELISA, strips, agglutination) find one species or toxin by antibody binding.
  • Genetic tests (PCR, NASBA, hybridization) detect DNA or RNA with high accuracy, but they can detect dead cells and need clean technique.
  • Biosensors join a biological detector to a reader for fast on-site testing, and the choice of method follows the question being asked.

Glossary

Sample

A measured part of a food or batch taken for testing, meant to represent the whole. Food tech example: 25 g of minced meat taken from several places in a batch for Salmonella testing.

Colony forming unit (CFU)

One living cell, or a clump of cells, that grows into one visible colony on a plate. Food tech example: a milk count of 10,000 CFU/ml means about 10,000 colony-forming cells in each millilitre.

Selective medium

A growth medium that lets one group of microbes grow while holding others back. Food tech example: violet red bile agar selects coliforms from a mixed milk sample.

Most probable number (MPN)

A statistical estimate of cell numbers from the pattern of positive and negative broth tubes at several dilutions. Food tech example: MPN counts coliforms in drinking water where numbers are too low for plates.

Gram stain

A staining method that separates bacteria into Gram-positive (purple) and Gram-negative (pink) groups. Food tech example: a Gram stain of a suspect colony helps decide which confirmatory test to run next.

DEFT

Direct epifluorescent filter technique, a fast microscopic count using a filter and fluorescent dye. Food tech example: DEFT counts cells in raw milk in about 30 minutes.

ATP bioluminescence

A test that measures ATP, the energy molecule of living cells, by the light made with luciferase enzyme. Food tech example: an ATP swab checks whether a cleaned table is truly clean.

Impedance

An electrical method that tracks microbial growth by the change in a medium's electrical resistance. Food tech example: impedance screening estimates the count in milk without waiting for colonies.

ELISA

Enzyme-linked immunosorbent assay, a test that uses antibodies and an enzyme colour change to find a target. Food tech example: ELISA screens food samples for staphylococcal enterotoxin.

Immunochromatography

A strip test where the sample flows along a strip and a coloured line appears if the target is present. Food tech example: a lateral flow strip at a receiving dock screens for Salmonella.

Agglutination

Visible clumping of antibody-coated beads when the target microbe is present. Food tech example: latex agglutination confirms a colony as Staphylococcus aureus.

PCR

Polymerase chain reaction, a method that copies a chosen piece of DNA again and again until it can be detected. Food tech example: real-time PCR confirms Listeria in a food sample within a day.

NASBA

Nucleic acid sequence-based amplification, a method that copies RNA at one steady temperature. Food tech example: NASBA detects RNA viruses and points more strongly to living cells than a DNA test.

Hybridization

Binding of a labelled DNA probe to its matching target DNA to show identity. Food tech example: a gene probe confirms the identity of a colony by hybridization.

Biosensor

A device that joins a biological detector, such as an antibody or DNA, to a reader that reports binding. Food tech example: a handheld biosensor detects a toxin in a plant without sending the sample to a lab.

Enrichment

Growing a sample in broth first so a rare target multiplies to a detectable level. Food tech example: enrichment broth lifts Salmonella numbers before an ELISA test.

Ct value

The PCR cycle at which the signal crosses a set threshold, used as a rough measure of how much target DNA was present at the start. Food tech example: a Ct of 20 means far more starting DNA than a Ct of 30 for the same target.

Detection limit

The smallest number of cells or amount of DNA a test can reliably find. Food tech example: a test with a detection limit of 100 cells per gram cannot prove a food holds fewer than that.

Poisson error

The chance variation in counting rare events, roughly the square root of the count. Food tech example: a plate with 16 colonies carries an error of about 4, so low counts are read with care.

References

  • William C. Frazier and Dennis C. Westhoff, Food Microbiology, 4th edition.
  • James M. Jay, Martin J. Loessner, and David A. Golden, Modern Food Microbiology, 7th edition.
  • Frances P. Downes and Keith Ito, Compendium of Methods for the Microbiological Examination of Foods, 4th edition.
  • Michael P. Doyle and Larry R. Beuchat, Food Microbiology: Fundamentals and Frontiers, 3rd edition.
  • Basanta Rai, Essentials of Industrial Microbiology.