SOP: Screening Raw Ground Meat and Meat Trim for E. coli O157:H7 with the BAX System Real-Time Assay (MFLP-76)

GIFSQ ID: SOP-1062

Enrichment does the waiting in this screen; the instrument work afterwards takes about an hour. Meat is enriched in one of two broths depending on sample size and type, a small aliquot is lysed, and lysate hydrates a PCR tablet that already carries primers, polymerase, nucleotides and a positive control. Fluorescence read in a closed tube then gives a presumptive result, so amplified DNA stays contained and carry-over risk stays low.

Coverage extends beyond the classic motile organism. Because the assay targets DNA specific to the O157:H7/NM serotype, non-motile variants that still carry the H7 genes are detected as well, along with all known atypical variants described in the source.

Purpose

Purpose is to detect Escherichia coli O157:H7/NM in raw ground meat and raw meat trim, for compliance with Sections 4 and 7 of the Food and Drugs Act and/or other relevant federal regulations. Results are presumptive: every positive must be confirmed with a cultural method.

Scope

Validation covers raw ground meat and meat trim that do not contain spices. Use on other foods requires validation first, following Compendium criteria, with data forwarded to the Microbiological Methods Committee so the application can be expanded where the data meet its requirements. Work follows ISO/IEC 17025 (latest version). Media and reagents are commercial products prepared and sterilised to manufacturer instructions, and a laboratory using any variation of a listed formulation must show equivalency and forward that data for consideration.

Equipment and Materials

  • BAX® System Q7 Start-Up Package (Cat. No. ASY2018): cycler/detector with verification plates; computer workstation with Microsoft Windows® operating system, BAX® system amplification software and printer; Automated Thermal Block (Cat. No. DMCH2023) or dry block heaters with thermometer inserts for lysis tubes; capping/decapping tools; pipettes for reagent and sample transfers (5 µL, 10 µL, 10–50 µL 8-channel, repeat pipettor); cooling block with inserts for lysis tubes and PCR tubes; PCR tube holders; lysis tubes with caps and rack; barrier or filter tips; powder-free nitrile gloves; BAX® System Q7 User Guide
  • BAX® System Real-Time PCR Assay for E. coli O157:H7 (Cat. No. KIT2000; sufficient for 96 tests): PCR tubes with tablets, flat optical caps, 2 lysis buffer bottles (12 mL/bottle) and protease solution (400 µL/vial) used to prepare working lysis reagent
  • Enrichment broths: BAX® System MP Media (MED2003 (2.5 kg) and MED2016 (StatMedia™)); modified tryptic soy broth (mTSB) with 2 mg/L novobiocin
  • Incubators or water baths capable of pre-warming media to 45 ± 2°C and maintaining enrichments at 42 ± 0.5°C
  • Stomacher for homogenising samples

Procedure

  1. Hold sample units before analysis according to product nature: refrigerated or frozen, shelf-stable foods excepted. Thaw frozen samples in a refrigerator, or under time and temperature conditions that prevent microbial growth or death. Analyse units as soon as possible after receipt. Keep incubator and water bath temperatures true: where a step at or below 37°C is stated, tolerance is ± 1.0°C, but higher temperatures must hold within 0.5°C because excess heat can be lethal to the organism being isolated.
  2. Pre-warm enrichment broth and prepare each sample by its category. Raw ground meat of 65 g or less: prepare BAX® System MP media to manufacturer instructions, and stomach the material until well dispersed in 9 volumes (1 in 10 dilution) of pre-warmed 42 ± 2°C BAX® System MP enrichment media; stomaching in a smaller volume first and then adding media to the required final volume is acceptable. Incubate at 42 ± 0.5°C for 9–24 h.
  3. Handle a raw ground meat composite of 66 to 375 g in the second broth. Prepare mTSB with 2 mg/L novobiocin, stomach the material until well dispersed in 4 volumes (1 in 5 dilution) of pre-warmed 45 ± 0.5°C mTSB with 2 mg/L novobiocin, again allowing a smaller stomaching volume topped up to the final volume. Incubate at 42 ± 0.5°C for 15–22 h, and continue incubation afterwards as needed to meet the minimum required incubation time for the confirmatory method MFHPB-10.
  4. Treat raw meat trim of 65 to 375 g in BAX® System MP media prepared to manufacturer instructions. Add four volumes (1 in 5 dilution) of pre-warmed 45 ± 0.5°C BAX® System MP enrichment media, and mix well by swirling or hand massaging the trim in the media. Incubate at 42 ± 0.5°C for 10–24 h.
  5. Ready the equipment before lysing. Make sure cooling blocks have been refrigerated overnight. Turn on heating blocks and check that temperatures are set to 37°C and 95°C. Initialise the cycler/detector as outlined in the BAX® System Q7 User Guide, create a rack file, and select RUN FULL PROCESS in the menu bar to warm up the cycler/detector before placing samples into the system.
  6. Prepare lysis. Arrange the required number of lysis tubes, one for each sample and one for the blank, in the rack according to the rack file. Make lysis reagent by pipetting 150 µL of protease into one 12 mL bottle of lysis buffer, and add 200 µL of lysis reagent to each lysis tube.
  7. Lyse the enriched sample. Transfer 20 µL of enriched sample to its corresponding lysis tube and secure the caps. With a manual heating block, heat tubes at 37°C for 20 minutes, then at 95°C for 10 minutes. With the Automated Thermal Block, use its preset parameters, which include cooling of samples. Place lysis tubes in the cooling block for at least 5 minutes.
  8. Hydrate the PCR tablets. Place the PCR tube holder into the PCR cooling block and set one PCR tube per sample in the holder. Remove and discard the lid from one strip of tubes at a time. With a multichannel pipettor, transfer 30 µL of each lysed sample into a corresponding PCR tube, cover tubes with a new optical cap strip and secure tightly, and repeat for all samples. Carry the whole cooling block to the cycler/detector; samples remain in the cooling block until the cycler/detector is ready for loading, but no more than 30 minutes after tablet hydration.
  9. Run amplification and detection by following the screen prompts in the PCR Wizard to load samples, run the program and unload samples, using the BAX® System Q7 User Guide for reference. During the run, primers amplify the target fragment and Scorpion™ probes, each probe carrying a different fluorescent dye for the two E. coli O157:H7/NM specific targets and for an internal control, together with a quencher, separate dye from quencher once incorporated into PCR product, increasing emission signal. Software measures the magnitude and characteristics of that signal change and applies its algorithm to call the result.
  10. Review results on the instrument display. For indeterminate results, repeat the analysis beginning with the transfer of enriched sample into lysis reagent (the lysis step above).
  11. Confirm presumptive positives from the presumptive enrichment broth, proceeding with the immunomagnetic separation, plating and confirmation steps of confirmation method MFHPB-10.

Recording Results

Record each unit by its category and enrichment branch, broth used, incubation time within its stated range, and the instrument call. Negative results can be reported as E. coli O157:H7/NM Not Detected. Repeated indeterminate results, more than one, or error results must be treated as presumptive positive and taken forward to confirmation in the same way as a positive screen. A presumptive positive is never a final result on its own: confirmation is cultural, starting from the enrichment broth.

Quality Control

One blank lysis tube runs with every set, alongside the tablet’s built-in positive control and internal control. Cooling blocks must have been refrigerated overnight before use, and heating block settings of 37°C and 95°C are checked before lysis begins. Hydrated tablets wait no longer than 30 minutes before loading. Any variation from a listed medium formulation needs laboratory equivalency data behind it.

Troubleshooting

  • Indeterminate result: repeat the analysis starting from transferring enriched sample into a fresh lysis tube; do not simply re-read the first run.
  • Repeated indeterminate or error results: stop treating the unit as unresolved: record it as presumptive positive and confirm it culturally from the enrichment broth.
  • Composite sample short of confirmatory incubation time: keep incubating the mTSB enrichment until the minimum required incubation time for MFHPB-10 is met before confirmation proceeds.
  • Suspected carry-over contamination: keep PCR tubes closed after hydration and loading; closed-tube fluorescent detection is built into the assay design to reduce carry-over of amplified DNA.

Interferences and Limitations

Approval is limited to raw ground meat and raw meat trim without spices; spiced products and other foods sit outside the validated scope until validated. Two enrichment systems appear side by side and are not interchangeable at will: sample size and type decide whether BAX® System MP media or mTSB with novobiocin applies, and incubation windows differ between branches. Presumptive results arrive about one hour after enrichment, but a cultural confirmation is still mandatory for positives.

Safety Notes

  • Treat all meat samples and enrichments as potentially carrying a human pathogen; use powder-free nitrile gloves and standard enteric precautions throughout.
  • Take care at the 95°C lysis step and around pre-warmed media at 45°C; hot tubes and broths burn skin on contact.
  • Dispose of enrichments, lysis tubes and PCR tubes as biohazard waste after results are recorded and any confirmation aliquot has been taken.

Source Method

Adapted in original wording from Health Canada method MFLP-76, Detection of Escherichia coli O157:H7 in Raw Meat Trim and Raw Ground Meat Using the BAX® System Real-Time E. coli O157:H7 Assay, April 2020, Compendium of Analytical Methods, Volume 3. This revised method replaced MFLP-76 dated November 2014.