Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses, certifications, and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

SOP: Determination of Mercury by Flameless Atomic Absorption Spectroscopy

GIFSQ — Global Institute for Food Safety & Quality

Principle

The sample is digested with H₂SO₄, HNO₃ and HClO₄ (perchloric acid). The digest is treated with a reducing solution; mercury vapours are flushed into the gas flow-through cell of an atomic absorption spectrophotometer; light from a mercury hollow cathode lamp is passed through the cell, and the mercury content of the sample is determined at 253.7 nm.

Apparatus required

  • Atomic absorption spectrophotometer equipped with mercury hollow cathode lamp and gas flow-through cell
  • Digestion apparatus: 250-ml flat-bottom boiling flask with 24/40 standard joint; water condenser of 12–18 mm internal diameter and 400 mm length in borosilicate glass with 24/40 standard joint, modified to hold 6 mm Raschig rings, filled with Raschig rings to a height of 100 mm with a 20 mm layer of 4 mm glass beads on top
  • Diaphragm pump with internal parts coated with acrylic paint and 16-gauge Teflon tubing for all connections
  • Gas inlet adapter with 24/40 standard joint
  • Variable transformer

Reagents

a. Reducing solution: mix 50 ml of H₂SO₄ with 300 ml of water; cool to room temperature and dissolve 15 g of NaCl, 15 g of hydroxylamine sulphate and 25 g of SnCl₂ in the solution; dilute to 500 ml

b. Diluting solution: to a 1000-ml volumetric flask containing 300–500 ml of water, add 58 ml of HNO₃ and 67 ml of H₂SO₄; dilute to volume with water

c. Magnesium perchlorate: placed as a drying agent in the filter flask and replaced as needed — caution: Mg(ClO₄)₂ is explosive in contact with organic substances

d. 2% sodium molybdate solution

e. Mercury standard solution: dissolve 0.1354 g of HgCl₂ in 100 ml of water (1 ml = 1000 μg); dilute 1.0 ml of this solution to 1 litre with 1 N H₂SO₄ before use (1 ml = 1 μg)

Sample preparation

Weigh 5 g of sample into the digestion flask; add 25 ml of 18 N H₂SO₄, 20 ml of 7 N HNO₃, 1 ml of 2% sodium molybdate solution and 5–6 boiling chips; connect the condenser to the flask

↓

Circulate water through the condenser; heat the flask gently for one hour; remove heat and allow to stand for 15 min

↓

Add 20 ml of HNO₃–HClO₄ (1+1) mixture through the condenser; stop the water circulation and boil vigorously until white fumes appear in the flask; continue heating for 10 min

↓

Cool the flask and cautiously add 10 ml of water through the condenser while swirling; again boil for 10 min; remove heat and wash the condenser with three 15-ml portions of water

↓

Cool the digest to room temperature and make up to 100 ml in a volumetric flask with water; transfer a 25-ml aliquot to another digestion flask and adjust the volume to about 100 ml with the diluting solution (reagent b).

Procedure

Adjust the pump output to about 2 litres of air per min by regulating the pump speed with the variable transformer; connect the apparatus as for the measurement, except for the gas inlet adapter

↓

With the pump working and the spectrophotometer set to zero, add 20 ml of reducing solution to the diluted aliquot; immediately connect the gas inlet adapter and aerate for about 3 min (adjust the aeration time to obtain maximum absorption)

↓

Record the absorption; disconnect the pressure on the out side of the pump and open the vent on the filter flask to flush the system

↓

Prepare a reagent blank and the standard curve: add 0.0, 0.02, 0.5, 1.0, 1.5 and 2.0 μg of mercury to a series of digestion flasks; to each add 100 ml of diluting solution; add the reducing solution and aerate the standards as for the sample and note the absorbance

↓

Plot absorbance against μg of Hg; determine the μg of Hg in the sample from the curve.

Calculation

Mercury, ppm = μg of Hg ÷ g of sample

Where,

  • μg of Hg = mercury read from the calibration curve (μg)
  • g of sample = weight of sample taken (g)

Precautions

  • Magnesium perchlorate is explosive in contact with organic substances — replace as needed and keep away from organics
  • Prepare the reagent blank through the same operations as the sample