SOP: Detecting Salmonella in Foods and Surfaces by VIDAS UP Salmonella SPT (MFLP-49)

GIFSQ ID: SOP-1050

Speed here comes from phage biology rather than from a shorter enrichment. Recombinant phage proteins coat the inside of the instrument’s Solid Phase Receptacle and capture Salmonella receptors from a heated aliquot of enrichment broth, after which an alkaline phosphatase conjugate and a fluorescent substrate produce a signal the VIDAS instrument reads automatically. One buffered peptone water enrichment at 42°C feeds the assay directly for most foods; only raw milk cheese takes an extra selective enrichment step.

Results stay presumptive by design. A test value at or above the threshold sends the analyst back to the refrigerated, non-boiled enrichment for cultural confirmation, so the broth handling in this SOP matters as much as the instrument run.

Purpose

Purpose is the rapid detection of Salmonella spp. in food products, for compliance with Sections 4 and 7 of the Food and Drugs Act and/or other relevant federal regulations. VIDAS UP Salmonella (Salmonella Phage Technology, SPT) is an automated qualitative enzyme immunoassay on the VIDAS family of instruments, based on the ELFA technique (Enzyme Linked Fluorescent Assay). Positive results must be confirmed with a cultural method.

Scope

Validated scope covers all foods and a variety of environmental surfaces. Sample sizes run from 25 g to 375 g under two supplement formats: liquid, dosed by volume, and tablet, sized for 25 g or 375 g samples only. Work follows ISO/IEC 17025:2005 (or latest version), and any variation on listed media formulations, commercial or made from scratch, needs equivalency shown by the laboratory, with equivalency data forwarded to the Editor of the Compendium of Analytical Methods. Environmental collection devices (cellulose sponge or swab) are moistened with 10 mL of neutralizing buffer or D/E neutralizing broth, and collection and transport of environmental surface samples follow the laboratory’s environmental sampling method (MFLP-41).

Equipment and Materials

  • VIDAS family instrument (mini-VIDAS or VIDAS 30) from bioMérieux Canada, Inc.
  • VIDAS UP Salmonella (SPT) kit (ref. 30707), containing the reagents, standards and controls for 60 test samples; one strip and one SPR per sample, control or standard
  • Salmonella Supplement (ref. 42650, 421202, 421203), in liquid or tablet form
  • SX2 Broth (ref. 42121), 20 tubes of 10 mL: required for raw milk cheese only
  • VIDAS Heat and Go (ref. 93554), or a water bath at 95–100°C, or an equivalent heating system
  • Buffered Peptone Water (BPW); stomacher and stomacher bags, blender or equivalent; pipette calibrated to dispense 500 µL with disposable tips; incubators capable of maintaining 42°C; vortex-type mixer; suitable surface disinfectant

Procedure

  1. Hold sample units refrigerated or frozen before analysis according to product nature, shelf-stable foods excepted. Thaw frozen samples in the refrigerator, or under time and temperature conditions preventing microbial growth or death, and analyse units as soon as possible after receipt. Have sterile BPW available at room temperature and clean the working area surface with a suitable disinfectant. For a representative analytical unit, agitate liquids or free-flowing materials until homogeneous, and take solid portions from several locations within the unit.
  2. For the liquid supplement format with 25–65 g food samples: aseptically place the food (25–65 g) in a stomacher-type bag and add BPW keeping a 1 in 10 (1:9) dilution of food to broth, for example 225 mL of BPW for a 25 g sample. Blend, stomach or vortex as required for thorough mixing.
  3. For environmental samples in the liquid format: add each sponge to 90 mL of BPW, or composite up to 10 sponges with 90 mL of BPW per sponge and mix well; place each swab into a tube with 10 mL of BPW, or composite up to 10 swabs with 10 mL of BPW per swab and mix well.
  4. Vortex-mix the liquid Salmonella Supplement before adding it to each sample, then add the volume matching the BPW volume used and mix the bag contents manually. Working examples: 1 mL of supplement for 225 mL of BPW, 400 µL for 90 mL of BPW, and 2.6 mL for 585 mL of BPW. Final supplement concentration is 4.4 µg/mL in BPW, based on the pre-sample volume; for a 1 L solution use 4.4 mL of supplement. Liquid supplement may be added directly to the BPW when no other testing will use the same sample. Incubate for 18–24 hours at 42 ± 0.5°C.
  5. For 375 g food samples (fruit and vegetable-based products, raw meats and raw poultry products) in the liquid format: aseptically place 375 g in a stomacher-type bag, add 1125 mL of BPW pre-heated to 40 ± 2°C, and mix for 2 minutes using a blender with paddles; for nuts, mix manually for 1 minute. Vortex-mix the supplement, add 5 mL to each 375 g sample, mix the bag contents manually, and incubate for 22–26 hours at 42 ± 0.5°C.
  6. For the tablet supplement format: the tablet must go into the BPW before the food sample is added, with approximately 1 minute allowed for the tablet to dissolve. Tablets come in two sizes, one for a 25 g sample and one for a 375 g sample; for any other sample size the liquid supplement must be used. For 25 g: add the 25 g tablet to 225 mL of BPW, wait until it has dissolved completely, aseptically add 25 g of food, blend, stomach or vortex for thorough mixing, and incubate 18–24 hours at 42 ± 0.5°C. For 375 g (fruit and vegetable-based products, raw meats and raw poultry products): add the 375 g tablet to 1125 mL of pre-warmed (40 ± 2°C) BPW before the sample, wait for complete dissolution, aseptically add 375 g of sample, mix 2 minutes with a paddle blender (nuts: manually for 1 minute), and incubate 22–26 hours at 42 ± 0.5°C.
  7. For raw milk cheese only, add a selective enrichment after the non-selective enrichment, whichever supplement form was used: mix manually, transfer 1 mL of suspension into 10 mL of SX2 broth pre-warmed to 40 ± 2°C, blend, stomach or vortex for thorough mixing, and incubate for 6–8 hours at 42 ± 0.5°C.
  8. Prepare the assay run. Remove from the refrigerator only the required reagents from the VIDAS UP Salmonella kit, using one strip and one SPR for each sample, control or standard, and reseal the storage pouch carefully after removing SPRs. Never mix components of different lots, and never use components past the expiry date. For a new kit lot, first enter the factory master calibration curve data (specifications) using the master lot entry card included with each kit, and calibrate with the standard provided in the kit for each new lot upon opening and every 28 days thereafter, following the package insert for PTC protocol data entry, master lot data entry and calibration.
  9. Heat the sample aliquot. After incubation of the non-selective or selective enrichment, as appropriate, mix the bag contents manually. Never heat the standards and controls supplied with the kit. VIDAS Heat and Go route, not for egg products, poultry samples, chocolate, cocoa or cocoa-derived products: transfer 0.5 mL of enrichment broth into the sample well on the strip, heat for 5 ± 1 minutes following the Heat and Go Operator’s Manual, then remove the strip and leave it to cool for 10 minutes. Water bath route: transfer 2 to 3 mL of enrichment broth into a tube, seal the tube, heat for 5 ± 1 minutes at 95–100°C, cool the tube, vortex-mix the boiled broth and transfer 0.5 mL into the sample well on the VIDAS strip. Store the remaining non-boiled enrichment broth in the refrigerator for up to 72 hours for confirmation of presumptive positives, and mix thoroughly after refrigeration before confirming.
  10. Run the assay. Insert the SPR and strip into the instrument and check that the colour labels with the assay code on the SPR and the reagent strips match. Initiate the assay as directed in the Operator’s manual: the instrument cycles reaction medium in and out of the SPR, Salmonella receptors bind to the coated SPR interior, washes remove unbound material, alkaline phosphatase conjugate binds to captured receptors, a final wash removes unbound conjugate, and substrate (4-methyl-umbelliferyl phosphate) is hydrolysed to fluorescent 4-methyl-umbelliferone, measured at 450 nm. After completion, remove SPRs and strips and dispose of them in an appropriate biohazard receptacle in accordance with applicable local regulations.
  11. Confirm presumptive positives culturally, using the non-boiled enrichment broth. Carry out the selective plating and confirmation steps of the cultural method MFHPB-20 (Isolation and identification of Salmonella from foods and environmental samples): plate the enrichment directly, and in addition transfer an aliquot of the enrichment broth to selective enrichment and continue through its plating and confirmation. If direct plating confirms the presumptive positive, the selective enrichment can be discontinued; if direct plating is negative, continue with plating and confirmation from the secondary enrichment broth.

Recording Results

At the end of the assay the instrument analyses results automatically, calculating a test value for each sample against internal reference thresholds and interpreting each result as positive or negative. A result with a Test Value ≥ 0.25 indicates the presumptive presence of Salmonella in the test sample. Record the test value, the interpretation, sample size and format used (liquid or tablet supplement; 25–65 g, 375 g, sponge or swab), enrichment times and temperatures, the heating route used, and, for every presumptive positive, the cultural confirmation outcome, since no VIDAS result is final until culture confirms it.

Quality Control

Kit standards and controls run with the assay, one strip and one SPR each, and are never heated. Calibration with the kit standard is performed for each new lot of reagents upon opening and every 28 days thereafter, with the new lot’s master calibration data entered from the master lot entry card before first use. Components from different lots are never mixed and expired components never used. Verify incubator and water bath temperatures: a stated 35°C allows ± 1.0°C, as do 30°C and 25°C, but higher temperatures such as 43 or 45.5°C must hold within 0.5°C because of potential lethality; enrichment here runs at 42 ± 0.5°C. Media prepared commercially or from scratch follow manufacturer instructions, with equivalency the laboratory’s responsibility for any variation.

Troubleshooting

  • Assay will not start or reads invalid on a new lot: confirm the master lot entry card data were entered and that calibration with the kit standard was performed on opening the lot; recalibrate if 28 days have passed.
  • Presumptive positive cannot be confirmed: check that confirmation used the non-boiled enrichment, refrigerated no longer than 72 hours and mixed thoroughly after refrigeration; boiled broth cannot grow.
  • Weak or failed run after heating: verify the heating route matched the matrix, the Heat and Go must not be used for egg products, poultry samples, chocolate, cocoa or cocoa-derived products; use the 95–100°C water bath route instead.
  • Suspect supplement dosing: recheck the format rules, tablets exist only for 25 g and 375 g samples and must dissolve in the BPW (about 1 minute) before the sample is added; all other sizes need liquid supplement at 4.4 µg/mL of pre-sample BPW volume.
  • Mismatched consumables: confirm the colour labels and assay codes on each SPR and reagent strip match before initiating the run.

Interferences and Limitations

Every positive is presumptive until a cultural method confirms it; the instrument result alone does not establish Salmonella presence. Heating exclusions limit the Heat and Go device for egg products, poultry, chocolate and cocoa matrices. Tablet supplement cannot serve sample sizes other than 25 g or 375 g. Confirmation broth keeps only up to 72 hours refrigerated, so delayed confirmation loses its material. Raw milk cheese is the one matrix needing the extra SX2 selective enrichment; omitting it invalidates that matrix’s result. Kit components are lot-specific and expire, mixed or expired lots are not permitted.

Safety Notes

  • Treat all enrichments and cultures as carrying Salmonella, a human pathogen; disinfect the working area before analysis and dispose of used SPRs and strips as biohazard waste under applicable local regulations.
  • Handle heated tubes and the 95–100°C water bath with thermal protection, and seal tubes before heating as the procedure requires (generic laboratory practice).
  • Contain aerosols during blending, stomaching and vortexing of enrichments (generic laboratory practice).

Source Method