SOP: Detecting Salmonella in Foods and on Surfaces by Assurance GDS (MFLP-36)

GIFSQ ID: SOP-1037

Concentration before amplification sets this system apart. Assurance GDS for Salmonella Tq first pulls target cells out of enriched broth with a magnetic PickPen device, separating them from competing flora and food matrix, then amplifies a highly conserved Salmonella DNA sequence in a rotary instrument with on-line optical reading.

Each reaction tube also carries a procedural control giving its own distinct fluorescence, read simultaneously and separately. Positive, negative and failed-amplification outcomes therefore come straight from instrument software at run end.

Purpose

Purpose is detection of Salmonella spp. in foods and environmental surface samples for compliance under Sections 4 and 7 of the Food and Drugs Act and other relevant federal regulations. Positive results must be confirmed with a cultural method.

Scope

Scope covers all foods and environmental surface samples except two categories: fruit and vegetable-based products, and ready-to-eat meat and poultry products. Enrichment broth changes by food type, and concentration handling splits three ways according to expected microbial load: low load and environmental samples, high load samples plus non-fat dry milk, and chocolate samples. Laboratories judge load themselves; as a general guide, raw and high-moisture foods count as high load, while processed and low-moisture foods count as low load.

Equipment and Materials

  • Assurance GDS for Salmonella Tq kit, Catalog no. 71008-100, sufficient for 100 tests: amplification tubes Tq in 25 strips of 4, holding lyophilised reagents and an internal positive control; Resuspension Buffer Tq, 1 vial; Concentration Reagent, 1 vial; Wash Solution, 1 vial
  • Enrichment and regrowth broths by food type: buffered peptone water (BPW), BPW with 0.4% novobiocin, brain heart infusion (BHI), reconstituted non-fat dry milk (NFDM), brilliant green water (BGW), plus 1% brilliant green dye solution for chocolate work
  • Assurance GDS Rotor-Gene system with computer and software; Assurance GDS sample concentration device (PickPen or equivalent); Assurance GDS vortex mixer
  • Various pipettors; cooling block, aluminium or gel; stomacher, blender or equivalent; incubators maintaining 36 ± 1°C
  • Sample wells and sample well base; resuspension plate; filter-barrier micropipette tips, 50 μL and 1 mL; repeat pipettor tips, 0.5 mL and 10 mL; PickPen tips; adhesive sealing film
  • Sampling sponges, swabs and bags; Dey-Engley neutralizing (D/E) broth or Letheen broth for pre-moistening sponges

Procedure

  1. Collect environmental surfaces with sponges pre-moistened in D/E broth or Letheen broth. Sponges and swabs hydrated with neutralizing buffer are not recommended for use with Assurance GDS Salmonella Tq, so avoid that combination.
  2. Foods: add 25 g sample to 225 mL enrichment broth chosen from list below, then blend, stomach or vortex for thorough mixing. Larger portions scale broth proportionally, keeping 1:9 ratio (1 in 10) up to a maximum sample size of 125 g. Environmental sponges: add each sponge to 100 mL BPW, or composite up to 10 sponges with 100 mL BPW per sponge, mixed well. Environmental swabs: add each swab to 10 mL BPW, or composite up to 10 swabs with 10 mL BPW per swab, mixed well. Incubate all enrichments, foods and environmental swabs alike, for 18 to 24 h at 36 ± 1°C.
  3. Raw fish and crustaceans: use 225 mL BPW with 0.4% novobiocin.
  4. Chocolate and bakery products: use 225 mL reconstituted non-fat dry milk, let stand for 1 h at room temperature (15–25°C), blend, stomach or vortex, adjust pH to 6.6–7.0, and add 0.45 mL 1% brilliant green dye solution per 225 mL enrichment.
  5. Non-fat dry milk: use 225 mL brilliant green water.
  6. Poultry rinse: place thawed or fresh bird into a heavy sterile plastic bag, add 1 L BPW, and shake vigorously so all sample surfaces contact broth, and/or massage poultry in bag. Pour broth off into a sterile container and incubate that broth.
  7. All other in-scope foods: use 225 mL BPW.
  8. Concentration setup: vortex Concentration Reagent. Set strips of sample wells into a sample well base and immediately transfer 20 μL Concentration Reagent to each required sample well, 1 well per sample, using a repeat pipettor and 0.5 mL tip. Cover wells with adhesive film strips.
  9. Prepare branch wells, covered with adhesive film: low load and environmental samples get 1.0 mL Wash Solution in an additional well per sample; high load and non-fat dry milk samples get 0.5 mL sterile BHI in an additional well per sample; chocolate samples get 1.0 mL Wash Solution in each of 2 additional wells per sample plus 0.5 mL sterile BHI in another additional well per sample. Use a repeat pipettor and 10 mL tip for these transfers.
  10. Prepare resuspension plate: transfer 45 μL Resuspension Buffer Tq to each needed well using a repeat pipettor and 0.5 mL tip, then cover plate with adhesive film strips.
  11. Add 1 mL incubated sample to each sample well holding Concentration Reagent. Return sample containers immediately to 36 ± 1°C incubator. Seal sample block with adhesive film, place on vortex mixer, and vortex at 900 rpm for 10 min, adjusting rpm if needed so liquid never contacts adhesive film. Remove film after mixing.
  12. Load tips firmly onto PickPen. Extend magnets, insert tips into first strip of sample wells, and stir gently for 30 sec while moving constantly up and down from surface to well bottom. Tap tips against well sides to shed excess media droplets.
  13. Low load and environmental finish: remove film from corresponding Wash Solution wells, transfer PickPen there, stir gently side to side for 5–10 sec with tips submerged, tap tips against well sides, then remove film from resuspension plate, move PickPen to corresponding resuspension row, submerge tips, retract magnets, and tap gently to release particles into Resuspension Buffer Tq.
  14. High load and non-fat dry milk finish: remove film from corresponding BHI wells, transfer PickPen there, submerge tips, retract magnets, and tap gently to release particles into BHI. Cover each strip with new adhesive film before adding samples to a new strip. Incubate BHI wells for 2–4 h at 36 ± 1°C. Afterwards remove film from resuspension plate and recapture particles from BHI with PickPen into corresponding resuspension row, submerging tips, retracting magnets, and releasing particles into Resuspension Buffer Tq.
  15. Chocolate finish: wash first (stir 5–10 sec in first Wash Solution well without releasing particles), tap tips, then release particles into BHI well as in high load branch; cover wells and incubate 2–4 h at 36 ± 1°C. Next move PickPen to second Wash Solution well, stir 5–10 sec, tap tips, then transfer to resuspension plate row, retract magnets, and release particles into Resuspension Buffer Tq.
  16. Repeat PickPen capture and branch finish for all samples, using new tips for each row. Cover resuspension plate with adhesive film strips.
  17. Amplification setup: gel cooling block must have been stored in freezer at −25 to −15°C for a minimum of 6 h before first use; frozen block changes to appropriate colour when ready. Keep block stored at −25 to −15°C when not in use, and return it to freezer between uses until colour shows readiness again, which may take up to 2 h.
  18. Remove amplification tubes Tq from foil pouch, place them in frozen gel cooling block, and reseal pouch. Open amplification tubes.
  19. Transfer 30 μL from each resuspension plate well into an amplification tube and press each lid down firmly to close. Before loading rotor, invert tubes together with cooling block and shake with a snapping motion to mix contents thoroughly; return upright and shake again with snapping motion so contents return to tube bottoms.
  20. Place amplification tubes into Assurance Rotor-Gene in sequential order beginning with position #1 and run program. Rotor-Gene must be started within 20 min after samples are added to amplification tubes.
  21. Confirm presumptive positives from primary enrichment broth: plate directly following cultural Salmonella plating practice (25 g in 225 mL pre-enrichment, then selective plating on at least two selective agars at 35°C for 24 ± 2 h), and also transfer an aliquot of enrichment broth to selective enrichment (1.0 mL into 9 mL tetrathionate brilliant green broth and 0.1 mL into 9 mL Rappaport-Vassiliadis soya peptone broth, both at 42.5°C for 24 ± 2 h) and continue from there. When direct plating already confirms positive result, selective enrichment may be discontinued; when direct plating is negative, continue plating and confirmation from selective enrichment.

Recording Results

Rotor-Gene software gives a results table at run end, identifying each sample as Positive, Negative, or No Amp. Positive means presumptive positive for Salmonella and triggers confirmation above. Negative means negative for Salmonella. No Amp means amplification did not occur: repeat analysis beginning at concentration step; if No Amp persists, contact BioControl Systems Technical Service. Record branch used, enrichment broth, incubation, and software call for every sample.

Quality Control

Every reaction tube carries its own procedural control, read separately by instrument, so a failed control shows up as No Amp rather than a false negative. Cooling block readiness is a control point in itself: never load tubes into a block that has not regained its ready colour after freezing. Incubation at 36°C allows 36 ± 1.0°C; lower temperatures such as 30 or 25°C also carry ± 1.0°C, while higher temperatures such as 43 or 45.5°C must hold within 0.5°C. Media variations must be proven equivalent by laboratory using them, and work should meet ISO/IEC 17025 requirements.

Troubleshooting

  • No Amp result: repeat from concentration step with fresh tips and wells; persistent failure goes to BioControl Systems Technical Service, not to repeated guessing.
  • Liquid touching adhesive film during vortexing: lower rpm; film contact loses sample and breaks well-to-well separation.
  • Poor capture suspected: check tips sit firmly on PickPen, magnets were extended during capture and retracted only for release, and stirring lasted full 30 sec.
  • Delay before rotor start: restart timing discipline; tubes must enter run within 20 min of sample addition, so stage rotor before resuspension transfers.

Interferences and Limitations

Fruit and vegetable-based products and ready-to-eat meat and poultry lie outside validation, however convenient testing them might seem. Neutralizing-buffer hydration undermines this system for sponges and swabs. Wrong load branch changes outcome quality: skipping BHI regrowth on high load samples, or adding it needlessly, departs from validated handling. As with other genetic screens, a positive reports target DNA in concentrated enrichment and remains presumptive until culture confirms it.

Safety Notes

  • Treat enrichments as potentially carrying Salmonella; use gloves, careful pipetting, and biohazard disposal for wells, tips and tubes.
  • Handle brilliant green dye solution and novobiocin broth with gloves and eye protection as general chemical practice.
  • Keep adhesive film, foil pouches and used amplification tubes sealed for disposal after runs, since tube contents include amplified DNA.

Source Method

Adapted in original wording from Health Canada method MFLP-36, Detection of Salmonella in Foods and Environmental Surface Samples: Assurance GDS for Salmonella Tq Genetic Detection System, March 2016, Compendium of Analytical Methods, Volume 3. Confirmation plating details stated in full above follow MFHPB-20, which this method incorporates for confirmation.