Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

SOP: Detecting Listeria spp. on Environmental Surfaces with the BAX® System Real-Time PCR Assay (MFLP-79)

GIFSQ ID: SOP-1068

Speed comes from a single enrichment followed by automated amplification. Sponges and swabs spend 20 to 24 hours in Actero™ Listeria Enrichment Media, a portion of enriched culture is heat-lysed, and lysate hydrates a ready-made PCR tablet inside a sealed tube. Inside that tablet sit primers, polymerase, nucleotides and a fluorescent Scorpion™ probe aimed at a DNA fragment unique to genus Listeria, so fluorescence during amplification signals whether listeriae were present.

Hands-on work stays small: 5 µL of enrichment goes into lysis, and 30 µL of lysate into a PCR tube. Tubes stay sealed through detection, cutting risk of contaminating a workspace with amplified product, and BAX® System Q7 software displays a result after a run of about an hour.

Purpose

Purpose is rapid screening for Listeria spp. on environmental surfaces, to determine compliance with Sections 4 and 7 of the Food and Drugs Act and/or other relevant federal regulations. A result is a genus-level screen from an enrichment, not a full cultural identification: presumptive positives move on to cultural confirmation.

Scope

Validated scope is a variety of environmental surfaces. Collection and transport of environmental surface samples follow MFLP-41, and a collection device is moistened with D/E Neutralizing broth. Work is carried out in accordance with ISO/IEC 17025:2005 (or latest version). Media and reagents listed are commercially available and are prepared and sterilised according to manufacturer instructions. Where a laboratory varies a listed medium formulation, whether a commercial product or one made from scratch, showing equivalency is that laboratory’s responsibility, and equivalency data go to the Editor of the Compendium of Analytical Methods for consideration of a method modification.

Equipment and Materials

  • BAX® System Q7 Start-Up Package (Cat. No. D12535562): BAX® System instrument and associated computer workstation; dry block heaters with thermometers and inserts for lysis tubes (an automated Thermal Block may replace dry block heaters); capping/decapping tools; pipettes and tips for reagent and sample transfers (two adjustable mechanical pipettes covering 20–200 µL and 5–50 µL, one repeating pipette, and one multi-channel pipette covering 8 channels and 5–50 µL); cooling block with inserts for lysis tubes and PCR tubes; PCR tube holders; lysis tubes with caps and rack; powder-free nitrile gloves; BAX® System User Guide
  • BAX® System Real-Time PCR Assay for Genus Listeria (Cat. No. D15131113; sufficient for 96 tests): PCR tubes with tablets, flat optical caps, lysis buffer (two 12 mL bottles) and protease (one 400 µL vial); Lysing Agent 2, used in lysis reagent preparation as set out under Procedure
  • Actero™ Listeria Enrichment Media (FoodChek Cat. No. FCM-011 or equivalent)
  • Incubator capable of maintaining 35 ± 1°C
  • Stomacher for homogenising samples; sterile stomacher bags; sponges and swabs as collected, including smaller swabs such as cotton-tip swabs
  • D/E Neutralizing broth, for moistening a collection device at sampling
  • For confirmation of presumptive positives: ALOA agar and Oxford agar

Procedure

  1. Keep sample units refrigerated in a laboratory before analysis, and analyse units as soon as possible after receipt.
  2. Pre-warm prepared Actero™ Listeria Enrichment Media to 35 ± 2°C.
  3. Place a sponge or swab in a sterile stomacher bag. Add 90 mL of pre-warmed Actero™ Listeria Enrichment Media to a sponge, or composite up to 10 sponges with 90 mL of media per sponge, ensuring complete coverage with media. Place smaller environmental swabs, for example cotton-tip swabs, in 9 mL of Actero™ Listeria Enrichment Media, or composite up to 10 swabs with 9 mL per swab.
  4. Stomach, vortex or homogenise as required for thorough mixing.
  5. Incubate samples for 20–24 hours at 35°C.
  6. Prepare for analysis. Make sure cooling blocks have been refrigerated overnight or otherwise chilled at 2–8°C. Turn on heating blocks and set temperatures to 55°C and 95°C. Initialise a BAX® System cycler/detector, performing verification if prompted, and create a rack file as described in the BAX® System Q7 User Guide.
  7. Prepare cluster tubes for lysis. Arrange a required number of lysis tubes, one for each sample and one for a “blank” as described in the BAX® User Guide, in a rack according to a rack file.
  8. Make lysis reagent by adding 150 µL of protease to one 12 mL bottle of lysis buffer, followed by addition of 200 µL of Lysing Agent 2. Prepared lysis reagent can be stored at 2–8°C for up to 2 weeks. Transfer 200 µL of prepared lysis reagent to each lysis tube.
  9. Mix an enriched sample thoroughly after its enrichment, then transfer 5 µL to a corresponding lysis tube, using new pipette tips for each sample. Secure caps once all transfers are complete.
  10. Heat cluster tubes. Place a rack of lysis tubes on a heating block pre-warmed to 55°C for 30 min, then transfer lysis tubes to a heating block pre-warmed to 95°C for 10 min. After lysis is complete, place lysis tubes in a cooling block for at least 5 min. Minimise time between removing cooling block inserts from a refrigerator and using them, and finish using cooling blocks within 30 min of removing them from a refrigerator. As an alternative, lysis heating steps can be performed using an automated Thermal Block, following an automated Thermal Block User Guide.
  11. Hydrate PCR tablets with lysate. Place PCR tube holders onto a PCR cooling block and arrange one PCR tube per sample in a holder. Remove and discard a lid from one strip of tubes at a time. Using a multi-channel pipette, transfer 30 µL of each lysed sample into a corresponding PCR tube, cover tubes with a new optical cap strip and secure tightly, and repeat for all samples. Samples must remain chilled at 2–8°C until loaded into an instrument.
  12. Take an entire cooling block to a cycler/detector. Follow screen prompts to load samples, run a program and unload samples, as specified in a User Guide. Run time is about an hour, including automated amplification, detection and result determination by a BAX® System Q7 instrument and software.
  13. Confirm presumptive positive results for Listeria spp. by proceeding with plating to ALOA and Oxford agars, and following confirmation steps of a cultural method (MFHPB-30 or MFHPB-07), as appropriate.

Recording Results

Record a result exactly as a BAX® System displays it, by colour and symbol. Green (–) means negative for a target organism. Red (+) means positive for a target organism. Yellow (?) means indeterminate results. Yellow (?) with a red slash means a signal error. Neither an indeterminate result nor a signal error is a negative or a positive, and each is recorded as displayed rather than converted into one. For every sample, also record enrichment time within a 20–24 hour window, lysis reagent preparation date where a stored reagent was used, a rack position matching a rack file, and, for presumptive positives, a plating outcome on ALOA and Oxford agars and a cultural confirmation outcome.

Quality Control

Include one “blank” lysis tube in every run, carried through lysis and PCR alongside sample tubes. Verify incubator and water bath temperatures: where 37°C or below is recommended, tolerance is ± 1.0°C (for example 35°C ± 1.0°C), whereas higher temperatures must hold within 0.5°C because of potential lethality for a microorganism being isolated. Perform instrument verification when a cycler/detector prompts for it. As general laboratory practice, check cooling blocks were chilled at 2–8°C before use and prepared lysis reagent was within its 2-week storage at 2–8°C.

Troubleshooting

  • Indeterminate result, yellow (?): record it as indeterminate, not as negative, and handle a sample under laboratory procedure for unresolved screens; a display gives no basis for calling genus Listeria present or absent.
  • Signal error, yellow (?) with a red slash: record it as a signal error and treat a run for that sample as having produced no valid determination.
  • Cooling blocks warming during setup: work promptly after removing inserts from refrigeration and finish using blocks within 30 min; chilled handling up to loading is part of a method, not a convenience.
  • Suspect amplicon contamination: keep PCR tubes sealed through detection, change pipette tips for every sample transfer into lysis tubes, and open only one PCR tube strip at a time while hydrating tablets.
  • Stored lysis reagent in doubt: discard reagent held over 2 weeks at 2–8°C or stored outside 2–8°C, and prepare a fresh bottle (150 µL protease and 200 µL Lysing Agent 2 per 12 mL buffer).

Interferences and Limitations

Validation covers a variety of environmental surfaces; surfaces outside validated scope are not covered here. Samples are read after a single 20–24 hour enrichment at 35°C, with no second enrichment stage. A genus-level PCR answer identifies no species and does not by itself establish compliance, which is why presumptive positives require plating to ALOA and Oxford agars and cultural confirmation. Samples must remain chilled at 2–8°C until loaded, and cooling blocks must be used within 30 min of leaving refrigeration, so delays between lysis, hydration and loading can compromise a run.

Safety Notes

  • Treat every enrichment as potentially carrying Listeria, a human pathogen; wear powder-free nitrile gloves, contain spills of enrichment culture, and dispose of cultures, lysis tubes and PCR tubes as biohazard waste.
  • Take care at heating blocks set to 55°C and especially 95°C, and handle hot lysis tube racks with protection against burns.
  • Keep PCR tubes sealed during detection, both for contamination control and to avoid handling amplified product; discard used tubes unopened.
  • Handle protease, lysis buffer and Lysing Agent 2 as laboratory chemicals according to their safety data, avoiding skin and eye contact.

Source Method

Adapted in original wording from Health Canada method MFLP-79, Detection of Listeria spp. in Environmental Surface Samples Using the BAX®System Real-Time PCR Assay for Listeria Genus, December 2018, Compendium of Analytical Methods, Volume 3.