SOP: Detecting Listeria monocytogenes in Selected Foods by iQ-Check Real-Time PCR (MFLP-54)
GIFSQ ID: SOP-1055
Speed comes from a single enrichment followed by real-time PCR, rather than days of plating. Food enriches in Listeria Special Broth for 25 ± 1 hr, DNA is released by bead beating and heat, and a kit assay amplifies a target sequence carried by Listeria monocytogenes. Fluorescence rises cycle by cycle when that target is present, and software calls each sample automatically.
Extraction runs two ways: individual screw-cap tubes or a deepwell microplate, with optional automation for extraction and PCR set-up. Either route feeds the same PCR, the same internal control check for inhibition, and the same rule that presumptive positives still need cultural confirmation.
Purpose
Purpose is rapid detection of Listeria monocytogenes in selected foods, to judge compliance with Sections 4 and 7 of the Food and Drugs Act and/or other relevant federal regulations. Detection rests on simultaneous amplification and detection of target DNA after enrichment, with results determined automatically by CFX Manager IDE software.
Scope
Validation covers ready-to-eat meat and poultry, fruit and vegetable-based products except raw processed vegetables, fish and seafood products except smoked fish, and frozen and fermented dairy products. Other foods are assumed usable, but must first be validated following Compendium criteria for fitness for purpose, with data sent to the Microbiological Methods Committee so approved scope can expand. Work follows ISO/IEC 17025 (latest version); any variation on listed media formulations needs equivalency shown.
Equipment and Materials
- iQ-Check Listeria monocytogenes Kit (Bio-Rad catalog # 3578124): Reagent A, lysis reagent, 1 bottle (20 mL) with magnetic stir bar; Reagent B, fluorescent probes, 1 tube (0.55 mL); Reagent C, amplification mix, 1 tube (4.4 mL); Reagent D, PCR negative control, 1 tube (0.5 mL); Reagent E, PCR positive control, 1 tube (0.25 mL); Reagent F, lysis beads, 1 tube (17.6 g)
- Listeria Special Broth (LSB, Bio-Rad catalog # 3555703 for 225 mL × 6, # 3564703 for 500 g, or # 3564753 for 5 kg), prepared and sterilised per manufacturer instructions
- Conical screw-cap sterile tubes, 1.5 mL (tube extraction only); deepwell microplates (deepwell extraction only); pre-pierced sealing film (Bio-Rad catalog # 3600040) or equivalent (deepwell only)
- Low-profile 0.2 mL PCR 8-tube strips without caps, thin-walled, white (Bio-Rad # TLS-0851XTU); low-profile unskirted PCR plates, 48 or 96 well, white (Bio-Rad # MLL4851XTU, MLL9651XTU, HSP9955XTU, HSP9655XTU); optical flat 8-cap strips, ultraclear (Bio-Rad # TCS0803XTU) or sealing film (Bio-Rad # MSB1001XTU)
- Powder-free gloves; sterile filter tips and micropipettes for 20 µL, 200 µL and 1000 µL; stomacher bag, or one with incorporated filter (recommended for meat and highly particulate samples); positive and negative control cultures; PCR mix tube (Bio-Rad # 3594901) and pipette tips (Bio-Rad # 3594902, 3594903) for the iQ-Check Prep system
- Real-time PCR system: CFX96 (Bio-Rad # 3600037) or MiniOpticon, with CFX Manager Software Industrial Diagnostic Edition (Bio-Rad # 3600042)
- Tube extraction only: bench-top centrifuge, maximum 10,000–12,000 × g, for 1.5 mL tubes; dry heat block maintaining 95–100°C; Cell Disruptor (Bio-Rad # 3591456). Deepwell extraction only: Thermoshaker maintaining 95–100°C (Bio-Rad # 3594995 base with 3594996 block, or # 3594999)
- Incubator maintaining 30°C; magnetic stir plate; plate sealer for hard-shell PCR plates (Bio-Rad # 1814000); stomacher, blender or equivalent; vortex mixer; iQ-Check Prep automation system (optional, Bio-Rad # 3594911)
Procedure
- Except for shelf-stable foods, keep units refrigerated or frozen by product type. Thaw frozen samples in a refrigerator, or under conditions preventing microbial growth or death, and analyse units as soon as possible after receipt.
- Pre-warm LSB to 30°C before use. Agitate liquids or free-flowing materials until homogeneous; for a solid, take portions from several locations within the unit.
- Prepare a 1 in 10 dilution aseptically: 25 g or mL of food into 225 mL of LSB. Other unit sizes, such as 65 g or mL, may be used while that dilution is maintained; never exceed a maximum composited sample size of 125 g or mL. Blend, stomach or vortex as required for thorough mixing.
- Incubate all samples at 30°C ± 1°C for 25 ± 1 hr.
- Switch on the heating block (tube) or Thermoshaker (deepwell) in advance to reach 95–100°C, plus the thermal cycler, computer and, where used, the iQ-Check Prep automation system.
- Pour all of Reagent F (lysis beads) carefully into Reagent A (lysis reagent). Stir the combined reagent (A+F) on a magnetic stir plate at medium speed, so beads stay in suspension while dispensing; non-homogeneous reagent could affect final results. Continue with tube extraction (step 7) or deepwell extraction (step 8).
- Tube extraction: add 100 µL of lysis reagent to each 1.5 mL screw-cap conical tube, add 100 µL of enriched sample, avoiding food particles, and mix by pipetting up and down a minimum of 3 times. Place tubes in the Cell Disruptor for 3 min ± 1 min, then in the heat block at 95–100°C for 15 min. Vortex at high speed, then centrifuge at 10,000–12,000 × g for 2 min.
- Deepwell extraction: add 100 µL of lysis reagent (A+F) to each well, then a 100 µL aliquot of each enriched sample, avoiding food particles. For iQ-Check Prep runs, place the unsealed plate, reagents and consumables into the instrument for automated processing. Seal with pre-pierced sealing film, place in the Thermoshaker at 95–100°C at 1,300 rpm for 15–20 min, then cool in the refrigerator for a minimum of 10 minutes.
- Prepare PCR mix by combining amplification solution (Reagent C) and fluorescent probes (Reagent B) in the proportions in the kit package insert chart. Use prepared mix (B + C) immediately; otherwise it is stable for 1 hour at 4°C.
- Add 45 µL of PCR mix to each well of a 48 or 96 well plate, pipetting carefully to avoid bubbles. Add 5 µL of each sample or control to its appropriate well; for tube-format extracts, pipette supernatant without disturbing the pellet. Alongside standard broth/enrichment controls, run one positive control (Reagent E) and one negative control (Reagent D) per assay; both are ready-to-use. Steps 9 to 11 are completed automatically by the iQ-Check Prep system when used.
- Seal with optical caps, or use the PX1 plate sealer for hard-shell plates only. Load the plate into the thermal cycler, close the lid, verify plate set-up and protocol selection, then click “run”. Save data in the chosen location when prompted; selecting “save” starts the protocol, and a report is generated at the end of the run.
- Check amplification curves before releasing any result. Software gives complete automated analysis, but typical shape must still be verified: flat baseline, then rapid exponential increase of fluorescence, then flattening out. Any other shape requires repeating the PCR from step 9; curves still atypical on repeat make the sample a presumptive positive, handled under step 14.
- Verify controls before interpreting samples. Validity requires: negative control Cq = N/A in the L. monocytogenes (FAM) channel with 28 ≤ Cq ≤ 40 for internal control (HEX); positive control 26 ≤ Cq ≤ 36 in FAM, internal control N/A. Cq is the cycle at which a curve crosses the threshold; N/A means fluorescence never rose significantly above background noise to cross it. Controls failing these values require repeating the PCR from step 9.
- Confirm every presumptive positive culturally, from the 24 hour LSB enrichment broth aliquot: carry out the plating and confirmation steps of the isolation procedure in cultural method MFHPB-30, using at least one chromogenic agar listed there in addition to Oxford agar; transfer 0.1 mL of presumptive positive broth to modified Fraser Broth and continue incubation and plating from Fraser Broth as MFHPB-30 indicates; and return the remainder of the 24 h LSB sample to the incubator for up to 48 h, as required for confirmation use. Once confirmed, other streams can be discontinued; however, every step above must be performed before a presumptive positive is reported as negative.
Recording Results
Read both channels together. FAM (L. monocytogenes) Cq ≥ 10, internal control (HEX) N/A: positive. FAM Cq = N/A, internal control Cq ≥ 28: negative. FAM Cq = N/A, internal control Cq = N/A: inhibition, and analysis repeats from PCR mix preparation. Negatives are reported as Listeria monocytogenes Not Detected. Repeated inhibition (more than one) or repeated atypical curves (more than one) instead become presumptive positives for cultural confirmation. Keep the software run report with control values and the curve check.
Quality Control
Each assay carries one kit positive control (Reagent E) and one kit negative control (Reagent D) beyond standard broth and enrichment controls; samples are interpreted only after controls meet their Cq criteria. Every reaction also carries a synthetic DNA internal control, amplified alongside target DNA and detected by a second fluorophore, HEX, while the L. monocytogenes probe carries carboxyfluorescein (FAM); internal control failure alongside absent target points to inhibition, not absence. Hold incubators at recommended temperatures, and keep lysis reagent homogeneous while dispensing.
Troubleshooting
- Inhibition result: both channels Cq = N/A. Repeat from PCR mix preparation; inhibition more than once moves the sample to presumptive positive and confirmation.
- Atypical curve: repeat from PCR mix preparation. Still atypical after repeat, the sample becomes a presumptive positive.
- Invalid controls: results cannot be read. Repeat the PCR from mix preparation whenever a control misses its Cq criteria.
- Weak or uneven lysis: keep Reagent A+F stirring at medium speed, keep food particles out of tubes and wells, and pipette only supernatant from tube extracts.
- Bubbles in wells: pipette PCR mix carefully, and verify plate set-up and protocol before starting.
Interferences and Limitations
Approval extends only to the validated commodities in Scope; other foods need their own validation. PCR inhibition can mask a true target, so absent internal control signal converts an apparent negative into an inhibition call and, when repeated, into a presumptive positive. Prepared PCR mix must be used immediately, or within 1 hour at 4°C. Presumptive positives are not final, and none can become a reported negative until every plating and confirmation step for it is complete. Without target DNA no fluorescence is detected; intensity grows only as amplicon accumulates.
Safety Notes
- Treat every enrichment as potentially containing Listeria monocytogenes; handle cultures, extracts and plates under standard microbiological practice for a foodborne pathogen, wearing powder-free gloves.
- Handle tubes and plates carefully off the heat block and Thermoshaker, which run at 95–100°C during lysis.
- Work aseptically throughout, to protect the analyst and keep extraneous contamination out of a presence/absence result.
- Dispose of used enrichments, lysates, tips and plates as infectious laboratory waste under local rules.
Source Method
This SOP is adapted in original wording from Health Canada method MFLP-54, “Detection of Listeria monocytogenes from Selected Foods Using iQ-Check Listeria monocytogenes PCR Detection Kit,” issued March 2023, in the Compendium of Analytical Methods, Volume 3.