Sample Preparation Quiz
GIFSQ ID: ART-1448
Test your knowledge with this free 20-question Sample Preparation quiz from Food Analysis & Analytical Chemistry, part…
What this quiz covers
The instrument gets the credit, but sample preparation decides the result. This quiz follows a food sample from the bulk lot to the clear test solution, and every step in between is a place where a good analysis can be lost. It starts with the ideas that govern the whole chain: the main goal is a homogeneous, representative test portion the method can actually accept, grinding increases homogeneity so small portions still mirror the whole sample, and compositing blends incremental samples into one average that represents the lot. Sub sampling uses proper dividers or quartering, and milk must be homogenized before pipetting because fat globules separate on standing.
The middle of the set works through the preparation techniques themselves. Solid phase extraction cleans and concentrates by retaining analytes or trapping interferences on a sorbent. Dry ashing burns organics away in a muffle furnace to leave minerals behind, wet digestion destroys organic matter with acids, and microwave assisted digestion does the same job faster in sealed vessels, reaching higher temperatures while preventing contamination and volatile losses. Fat is extracted first because it interferes with many determinations, enzymatic digestion releases bound analytes such as starch for sugar analysis, and freeze drying removes water gently by sublimation so heat sensitive components survive. Contamination is controlled with clean glassware, method blanks, and high and low level samples kept apart.
Preparation decides the result before the instrument runs
No detector can correct for a sample that does not represent the lot, and no calibration can rescue a preparation that lost the analyte or added contamination. That is why the quiz keeps returning to the same checks: record every dilution, because the final result is multiplied by the dilution factor and errors scale up with it; keep grinding cool, because heat degrades vitamins and flavours and drives off moisture; and run a method blank, because a blank that should be clean but is not tells you the process added the signal. QuEChERS sums up the modern aim in its name: quick, easy, cheap, effective, rugged, safe.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the methods and standards a food analyst is expected to know by heart.
Choose how you want to play
A short note: sample preparation
Sample preparation turns a bulk sample into a uniform, representative test portion. Grinding and milling raise homogeneity so small portions represent the sample. Avoid excess grinding heat: it degrades vitamins and flavours and loses moisture.
Compositing blends increments into one sample whose average represents the lot. Sub-sampling uses dividers or quartering to keep the portion true to the bulk. Homogenising liquids such as milk keeps fat and solids even.
Solid-phase extraction passes the extract through a sorbent that retains analytes or traps interferences. Fat extraction, such as Soxhlet, removes fat that interferes with many determinations. Dry ashing burns off organics, leaving minerals or ash. Wet digestion with acids destroys organic matter before mineral analysis. Microwave digestion is faster and hotter in closed vessels, minimising contamination and volatile losses. Enzymatic digestion releases bound analytes, such as starch for sugar. QuEChERS pulls many analytes out fast with acetonitrile and dispersive cleanup.
pH adjustment puts the analyte in the right form for extraction or stability. Filtration and centrifugation give a clear test solution, free of solids. Record dilution accurately: the final result is multiplied by the factor, so errors scale up. Prevent contamination with clean glassware, blanks, and separating high and low samples. A method blank detects contamination from reagents and prep steps. Freeze-drying removes water gently, without heat damage to sensitive components. Microbiological prep needs sterile technique so no microbes enter and none are killed.
Practical takeaway: prepare the portion to represent the lot, and run a blank with every batch.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: Solid-phase extraction (SPE) cleanup before chromatographic analysis is used to:
Correct answer: Selectively retain analytes or remove interferences, concentrating the extract
SPE passes the extract through a sorbent that selectively retains the analytes (or traps the interferences), washing away the rest : simultaneously cleaning up and concentrating the sample. SPE principles are detailed in Thurman & Mills, Solid-Phase Extraction: Principles and Practice (1998).
Question 2: Compositing several incremental samples into one laboratory sample is done to:
Correct answer: Obtain an average composition representing the lot while reducing the number of analyses
Compositing blends multiple incremental samples into one laboratory sample whose average composition represents the whole lot, cutting the number of analyses while keeping them representative. Representative compositing is core sampling theory per Gy, Sampling for Analytical Purposes (1998).
Question 3: pH adjustment during preparation may be needed to:
Correct answer: Optimise extraction or keep the analyte stable
Adjusting pH sets the analyte in the right chemical form : ionized or neutral, stable or reactive : which controls how well it extracts and whether it survives preparation. pH optimization in sample prep is standard practice per Nielsen, Food Analysis (5th ed., 2017).
Question 4: Filtration/centrifugation in sample prep:
Correct answer: Separates solids from liquids to give a clear test solution
Filtration and centrifugation physically separate suspended solids from the liquid, yielding the clear test solution that instruments and titrations require. Both are standard clarification steps described in Nielsen, Food Analysis (5th ed., 2017).
Question 5: Contamination during prep is prevented by:
Correct answer: Clean glassware, blanks, and separation of high/low-level samples
Contamination is controlled by clean glassware, running method blanks, and keeping high- and low-level samples apart so trace carryover cannot masquerade as a real result. These controls are required good practice under ISO/IEC 17025:2017.
Question 6: Dry ashing (muffle furnace) is used for:
Correct answer: Removing organics at high temperature to determine minerals or ash content
Dry ashing burns the sample in a muffle furnace at high temperature to destroy organic matter, leaving the mineral/ash residue behind for determination. Ash determination by muffle furnace follows AOAC Official Methods such as AOAC 923.03.
Question 7: Dilution must be recorded accurately because:
Correct answer: The final result is multiplied by the dilution factor, errors scale up
The final concentration equals the measured value multiplied by the dilution factor, so any volumetric error is magnified by that same factor. Careful dilution practice is stressed in Harris, Quantitative Chemical Analysis (10th ed., 2020).
Question 8: Sub-sampling (splitting) should be done:
Correct answer: With proper dividers or quartering so the portion stays representative
Proper sub-sampling uses sample dividers or quartering so that the small portion taken carries the same composition as the bulk : a spoonful by eye does not. Representative splitting techniques follow Gy, Sampling for Analytical Purposes (1998).
Question 9: Homogenisation of liquid samples (e.g. milk) before pipetting:
Correct answer: Keeps fat and solids evenly distributed in the test portion
Milk must be homogenized before pipetting because fat globules and solids separate on standing; only a uniform mixture gives a test portion that truly represents the sample. Representative milk sampling is specified in ISO 707:2008 (IDF 50).
Question 10: Fat extraction (e.g. Soxhlet) before analysis is needed because:
Correct answer: Fat interferes with many determinations and must be isolated or removed
Fat interferes with many determinations : blocking extractions, fouling columns, biasing gravimetry : so it is isolated or removed by extraction (for example Soxhlet) before analysis. Fat extraction by Soxhlet follows AOAC Official Methods such as AOAC 920.39.
Question 11: Sample prep for microbiological testing differs by requiring:
Correct answer: Aseptic technique to avoid introducing or killing microbes
Microbiological prep must use aseptic technique: sterile tools and vessels so no outside microbes are introduced and no target organisms are killed before plating. Aseptic sampling requirements are given in ISO 7218:2007 (microbiology of food and animal feeding stuffs).
Question 12: Microwave-assisted acid digestion is favored over open-beaker digestion for trace metals because it:
Correct answer: Is faster, reaches higher temperatures in closed vessels and minimizes contamination and volatile losses
Sealed microwave digestion heats acids and sample far above their atmospheric boiling points, digesting faster than an open beaker while preventing contamination and volatile-analyte losses. Microwave sample preparation was introduced by Kingston & Jassie in Introduction to Microwave Sample Preparation (1988).
Question 13: Enzymatic digestion in prep is used for:
Correct answer: Releasing bound analytes, e.g. starch for sugar analysis
Enzymatic digestion uses enzymes to break matrix bonds and release bound analytes : for example, amylases freeing starch so its sugars can be measured. Enzymatic starch hydrolysis for analysis is the basis of AOAC 996.11 (1996).
Question 14: Wet digestion with acids is used to:
Correct answer: Destroy organic matter before mineral/elemental analysis
Wet digestion with concentrated acids oxidizes and destroys organic matter, leaving a clear solution ready for mineral and elemental analysis. Acid digestion for elemental analysis is described by Kingston & Jassie in Introduction to Microwave Sample Preparation (1988).
Question 15: Freeze-drying (lyophilization) may be used in sample preparation when the analyst needs to:
Correct answer: Remove water gently without heat damage before analysis of heat-sensitive components
Freeze-drying removes water by sublimation under vacuum, so heat-sensitive vitamins, flavors, and enzymes survive preparation undamaged. Low-temperature dehydration for labile analytes is described in Nielsen, Food Analysis (5th ed., 2017).
Question 16: Why must grinding avoid excessive heat?
Correct answer: Heat can degrade analytes (vitamins, flavours) and lose moisture, biasing results
Excessive grinding heat can degrade vitamins and volatile flavors and drive off moisture, changing the very composition the analysis is supposed to measure. Heat effects during milling are a known bias source per Nielsen, Food Analysis (5th ed., 2017).
Question 17: Why analyse a method blank alongside samples?
Correct answer: To detect contamination from reagents and prep steps
A method blank goes through every reagent and prep step without the sample, so any signal it produces flags contamination coming from the procedure itself. Method blanks are required contamination checks under ISO/IEC 17025:2017.
Question 18: The main goal of sample preparation is to:
Correct answer: Produce a homogeneous, representative test portion suitable for the analytical method
Sample preparation exists to convert a bulk sample into a homogeneous, representative test portion that the analytical method can actually accept and measure. This purpose is stated in Nielsen, Food Analysis (5th ed., 2017).
Question 19: Grinding/milling of solid foods before analysis:
Correct answer: Increases homogeneity so small test portions represent the sample
Grinding and milling break down particle-size variation so that a tiny test portion still mirrors the whole sample : the foundation of representativeness. Particle-size reduction in sampling theory follows Gy, Sampling for Analytical Purposes (1998).
Question 20: The QuEChERS approach to sample preparation is valued for pesticide analysis because it:
Correct answer: Extracts many analytes quickly with acetonitrile and dispersive cleanup in a few steps
QuEChERS extracts a broad range of pesticides with acetonitrile and salts, then cleans the extract dispersively, all in a few quick steps : hence its name: quick, easy, cheap, effective, rugged, safe. The approach was introduced by Anastassiades et al. in the Journal of AOAC International (2003).