Analytical Errors Quiz

GIFSQ ID: ART-1446

Test your knowledge with this free 20-question Analytical Errors quiz from Food Analysis & Analytical Chemistry, part…

What this quiz covers

Every number a food laboratory reports carries a doubt with it, and this quiz is about naming that doubt correctly. It starts with the two families of error: random error, the small reading to reading scatter that averages out when you repeat a measurement, and systematic error, the steady push in one direction that repetition can never fix. An uncalibrated pipette that always delivers 9.8 mL instead of 10 mL is the classic systematic error, while judging a titration endpoint a fraction differently each time is random. Accuracy and precision are not the same thing either: a laboratory can produce tightly clustered results that are all wrong in the same direction.

The middle of the set turns to the tools that keep error visible and under control. Error bars show the estimated uncertainty, the range that plausibly holds the true value. Certified reference materials expose bias because a steady offset from a certified value cannot be argued away. Standard addition calibrates inside the sample matrix itself, cancelling the matrix effects that shift signals in one direction. Duplicates reveal random error and check repeatability, outliers are investigated before any removal is considered, and calibration drift is caught before it biases a whole run. The set also covers the working details: relative error for comparing errors across scales, the right balance readability for the sample mass, and reporting only the decimal places the method can truly deliver.

Random error scatters, systematic error steers

That single contrast explains most of the quiz. Random error spreads results around the true value and shrinks when you replicate, which is why duplicates and averaging help. Systematic error moves every result the same way, so only a reference material, a validated method, or a corrected calibration can expose it. Gross errors sit apart from both: a wrong sample or a mislabelled flask is a one off mistake, not part of how the method performs. Once that picture is clear, error propagation follows: the uncertainties of each measurement combine into the uncertainty of the final result.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the definitions and standards a food analyst is expected to know by heart.

Analytical Errors Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: analytical errors

Analytical errors in food analysis are the differences between a measured value and the true value. Absolute error is the gap between what you measured and the true value. Relative error divides that by the true value. Error bars show the estimated uncertainty.

Random errors scatter results on both sides of the true value, for example slight variation in judging a titration endpoint. They average out with replication, and duplicates reveal them and check repeatability. Systematic errors, also called determinate errors, push results consistently in one direction, such as a pipette that was never calibrated, delivering 9.8 mL when it should deliver 10 mL, or calibration drift shifting later samples. Matrix effects cause systematic bias, since food components suppress or boost the analyte signal. Gross errors are different again: one-off blunders such as the wrong sample or a mislabelled flask.

A systematic error is detected with certified reference materials, where a consistent offset reveals bias, and the best defence is regular CRM use with a fully validated method, as ISO/IEC 17025 requires. Standard addition compensates for matrix effects by calibrating inside the sample itself. Outliers must be investigated and kept unless an assignable cause or valid test justifies removal. Results must not carry more decimal places than the method can deliver, and individual uncertainties combine into the final result through propagation of errors.

Practical takeaway: run a CRM with every batch, and never delete an outlier without an assignable cause or a valid statistical test.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: Which is an example of random error?

  • A. An example of random error is wrong method
  • B. Slight reading-to-reading variation in judging a titration endpoint
  • C. An example of random error is expired reagent
  • D. An example of random error is biased balance

Correct answer: Slight reading-to-reading variation in judging a titration endpoint

Random error shows up as small, unpredictable reading-to-reading differences : exactly what happens when judging a color-change titration endpoint slightly differently each time. Harris, Quantitative Chemical Analysis (10th ed., 2020) defines random error as variation about the mean that averages toward zero with repetition.

Question 2: Error bars on a reported result represent:

  • A. Error bars on a reported result represent mistakes
  • B. Error bars on a reported result represent formatting
  • C. The estimated uncertainty, the range plausibly containing the true value
  • D. Error bars on a reported result represent the analyst's mood

Correct answer: The estimated uncertainty, the range plausibly containing the true value

Error bars communicate the estimated uncertainty of a result: the interval that plausibly contains the true value. This is the core concept of the ISO/IEC Guide 98-3, the Guide to the Expression of Uncertainty in Measurement (GUM, JCGM 2008).

Question 3: A result far from replicates (outlier) should be:

  • A. A result far from replicates (outlier) should be deleted silently
  • B. A result far from replicates (outlier) should be averaged in quietly
  • C. Investigated, retained unless an assignable cause or valid statistical test justifies removal
  • D. A result far from replicates (outlier) should be hidden away

Correct answer: Investigated, retained unless an assignable cause or valid statistical test justifies removal

An outlier must be investigated first and kept unless an assignable cause is found or a valid statistical test (such as Grubbs' test) justifies removal : deleting or quietly averaging it away is data manipulation. Grubbs' outlier procedure was published in Technometrics (1969).

Question 4: Matrix effects are a source of:

  • A. Matrix effects are a source of random error only
  • B. Systematic bias, food components interfering with the analyte signal
  • C. Matrix effects are a source of no error
  • D. Matrix effects are a source of gross error

Correct answer: Systematic bias, food components interfering with the analyte signal

Food components can suppress or boost the analyte signal, shifting every result in one direction; that directional interference is a systematic bias, not random noise. Matrix-induced bias is described in Harris, Quantitative Chemical Analysis (10th ed., 2020).

Question 5: Relative error is useful because it:

  • A. Relative error is useful because it always hides all mistakes
  • B. Relative error is useful because it is always very small
  • C. Expresses error as a fraction of the true value, allowing comparison across scales
  • D. Relative error is useful because it needs no true value

Correct answer: Expresses error as a fraction of the true value, allowing comparison across scales

Relative error divides the absolute error by the true value, putting the error in context so a 0.1 g error on 1 g can be compared with one on 100 g. This fractional-error concept is standard in Harris, Quantitative Chemical Analysis (10th ed., 2020).

Question 6: A determinate (systematic) error can be detected by:

  • A. A determinate (systematic) error can be detected by estimating
  • B. Analysing certified reference materials, consistent offset reveals bias
  • C. A determinate (systematic) error can be detected by ignoring it
  • D. A determinate (systematic) error can be detected by more coffee

Correct answer: Analysing certified reference materials, consistent offset reveals bias

A determinate (systematic) error reveals itself when certified reference materials are analyzed: a consistent offset from the certified value exposes the bias. The use of CRMs to detect bias is required practice in ISO/IEC 17025:2017.

Question 7: Standard addition calibration compensates for:

  • A. Standard addition calibration compensates for analyst laziness
  • B. Standard addition calibration compensates for broken instruments
  • C. Matrix effects, by calibrating within the sample itself
  • D. Standard addition calibration compensates for bad sampling

Correct answer: Matrix effects, by calibrating within the sample itself

Standard addition spikes known amounts of analyte directly into the sample, so calibration happens inside the very matrix that would otherwise interfere, cancelling matrix effects. The technique is detailed in Harris, Quantitative Chemical Analysis (10th ed., 2020).

Question 8: The best defence against undetected systematic error is:

  • A. The best defence against undetected systematic error is experience
  • B. The best defence against undetected systematic error is faster work
  • C. The best defence against undetected systematic error is new staff
  • D. Regular use of certified reference materials and method validation

Correct answer: Regular use of certified reference materials and method validation

Regular analysis of certified reference materials plus a fully validated method is the strongest protection, because undetected systematic error by definition hides from everything else. ISO/IEC 17025:2017 builds its quality requirements around exactly this combination.

Question 9: Why run duplicate analyses?

  • A. To reveal random error and check repeatability
  • B. Run duplicate analyses to double costs
  • C. Run duplicate analyses because of tradition
  • D. Run duplicate analyses to use reagents

Correct answer: To reveal random error and check repeatability

Duplicates expose random error by showing how much replicate measurements scatter, which is the practical measure of a method's repeatability. Replicate analysis for precision estimation follows ISO 5725 (Accuracy of measurement methods and results).

Question 10: A laboratory that confuses accuracy with precision may:

  • A. A laboratory that confuses accuracy with precision may do great work
  • B. A laboratory that confuses accuracy with precision may save money
  • C. A laboratory that confuses accuracy with precision may win awards
  • D. Produce tightly clustered but biased results, believing them correct

Correct answer: Produce tightly clustered but biased results, believing them correct

Precision without accuracy produces tightly clustered results that are all wrong in the same direction : and a lab that confuses the two mistakes that tight cluster for correctness. Harris, Quantitative Chemical Analysis (10th ed., 2020) separates the concepts: precision is reproducibility, accuracy is closeness to truth.

Question 11: Which is an example of systematic error?

  • A. An example of systematic error is a draught moving a balance
  • B. An example of systematic error is a shaky hand
  • C. An example of systematic error is a power flicker
  • D. An uncalibrated pipette delivering 9.8 mL instead of 10 mL every time

Correct answer: An uncalibrated pipette delivering 9.8 mL instead of 10 mL every time

An uncalibrated pipette that always delivers 9.8 mL instead of 10 mL imposes the same directional shortfall on every measurement : the signature of systematic error. A consistent, repeatable bias that replication cannot remove is the textbook illustration in Harris, Quantitative Chemical Analysis (10th ed., 2020).

Question 12: The absolute error of a measurement is:

  • A. Always zero
  • B. A percentage
  • C. An estimate
  • D. Measured value minus true value

Correct answer: Measured value minus true value

Absolute error is the measured value minus the true value, carrying the units of the measurement itself. This is the IUPAC Gold Book definition of error of measurement.

Question 13: Gross errors (blunders) differ from systematic/random errors because they:

  • A. Gross errors (blunders) differ from systematic/random errors because they are small
  • B. Gross errors (blunders) differ from systematic/random errors because they are unavoidable
  • C. Are one-off mistakes, wrong sample, mislabelled flask, not part of method performance
  • D. Gross errors (blunders) differ from systematic/random errors because they are statistical

Correct answer: Are one-off mistakes, wrong sample, mislabelled flask, not part of method performance

Gross errors : blunders like pipetting the wrong sample or mislabeling a flask : are one-off mistakes, not part of the method's inherent random or systematic performance. Harris, Quantitative Chemical Analysis (10th ed., 2020) treats blunders as a separate category of error.

Question 14: Using a balance with 0.1 g readability to weigh 0.05 g samples causes:

  • A. Large relative error, the instrument is wrong for the job
  • B. Using a balance with 0.1 g readability to weigh 0.05 g samples causes great accuracy
  • C. Using a balance with 0.1 g readability to weigh 0.05 g samples causes faster work
  • D. Using a balance with 0.1 g readability to weigh 0.05 g samples causes better precision

Correct answer: Large relative error, the instrument is wrong for the job

With 0.1 g readability, the instrument cannot resolve a 0.05 g weighing meaningfully : the readability is twice the sample mass, so the relative error is enormous. Harris, Quantitative Chemical Analysis (10th ed., 2020) warns against using an instrument whose readability is a large fraction of the quantity weighed.

Question 15: Random errors affect results by:

  • A. Causing scatter around the true value, reducible by replication
  • B. Random errors affect results by biasing them high
  • C. Random errors affect results by breaking instruments
  • D. Random errors affect results by deleting data

Correct answer: Causing scatter around the true value, reducible by replication

Random errors scatter results around the true value in both directions, and because they average out, replication reduces their effect. Harris, Quantitative Chemical Analysis (10th ed., 2020) contrasts this with bias, which replication cannot fix.

Question 16: Systematic errors in analysis are characterised by:

  • A. Systematic errors in analysis are characterised by random scatter
  • B. Systematic errors in analysis are characterised by occasional mistakes
  • C. Systematic errors in analysis are characterised by perfect accuracy
  • D. Consistent bias in one direction, e.g. always reading high

Correct answer: Consistent bias in one direction, e.g. always reading high

Systematic errors push results consistently in one direction : always high or always low : which is what distinguishes them from random scatter. Harris, Quantitative Chemical Analysis (10th ed., 2020) defines systematic error as a persistent directional component.

Question 17: Calibration drift during a run introduces:

  • A. Systematic error across later samples
  • B. Calibration drift introduces random error
  • C. Calibration drift introduces no error
  • D. Calibration drift introduces better accuracy

Correct answer: Systematic error across later samples

Calibration drift shifts the response curve progressively, so later samples inherit the same directional bias : a systematic error across the run, not random noise. Harris, Quantitative Chemical Analysis (10th ed., 2020) notes that uncorrected drift biases whole batches.

Question 18: Analyst-to-analyst differences in a method reflect:

  • A. Random/intermediate precision components, addressed by training and SOP detail
  • B. Analyst-to-analyst differences in a method reflect systematic error
  • C. Analyst-to-analyst differences in a method always reflect fraud
  • D. Analyst-to-analyst differences in a method always reflect nothing

Correct answer: Random/intermediate precision components, addressed by training and SOP detail

Differences between analysts working under the same method are intermediate-precision (within-laboratory) components, which is why they are addressed through training and detailed SOPs. ISO 5725-3 defines intermediate precision conditions including operator and time variation.

Question 19: Reporting results with too many decimal places:

  • A. Too many decimal places shows skill
  • B. Implies precision the method cannot deliver
  • C. Too many decimal places is required
  • D. Too many decimal places saves ink

Correct answer: Implies precision the method cannot deliver

Extra decimal places claim a resolution the method never achieved, misleading anyone who reads the result as more trustworthy than the measurement supports. The EURACHEM/CITAC Guide on measurement uncertainty states results must be rounded to match the method's actual capability.

Question 20: Propagation of errors means:

  • A. Propagation of errors means errors spread disease rapidly
  • B. Uncertainties in individual measurements combine into the final result's uncertainty
  • C. Propagation of errors means errors multiply staff rapidly
  • D. Propagation of errors means mistakes are always contagious

Correct answer: Uncertainties in individual measurements combine into the final result's uncertainty

Every measurement feeding a calculation carries its own uncertainty, and those uncertainties combine into the uncertainty of the final result : the subject of error propagation. The combination rules are given in the ISO/IEC Guide 98-3 (GUM, JCGM 2008).