GIFSQ ID: ART-1461

Test your knowledge with this free 20-question Reference Materials quiz from Food Laboratory Management, part of the…

What this quiz covers

Every measurement a food laboratory reports is only as good as the standard it was checked against, and this quiz is about those standards: reference materials. It opens with the certified reference material, a reference material with certified property values, a stated uncertainty and metrological traceability, and the reason food laboratories use them: to verify method accuracy and calibrate instruments against a trusted standard. A regular reference material may carry no certified values at all. ISO 17034 is the standard for the producers of reference materials, setting the requirements that make their competence and their certified values trustworthy, and metrological traceability is the property that links a measurement result to a reference through an unbroken chain of calibrations.

The middle of the set covers the practical life of a reference material in the laboratory. The certificate must be checked before use, to confirm the material is in date, stored correctly, and valid for the intended analyte and matrix, and it is stored exactly as the certificate directs so the certified values survive. The documentation for each material in use records its identity, source, certificate, storage conditions, expiry and usage log. A matrix reference material carries a food-like matrix, such as milk powder with a certified lead content.

Use the CRM in the run, and spend it wisely

The habits the quiz stresses are about catching bias early and spending expensive material wisely. A CRM is analysed alongside samples, so any bias in that run is detected, and plotting CRM results on a quality control chart helps the laboratory spot analytical drift or bias shifts early. Stability is watched by periodic re-analysis against fresh standards or by trend review of quality control data, and certificates expire or are withdrawn when stability can no longer be assured or the certified values are superseded. If a CRM result falls outside its certified range, the laboratory investigates, stops reporting affected results and corrects the problem first. A secondary working standard calibrated against a CRM preserves the expensive CRM while giving traceable daily calibration, and an in-house working reference material covers routine quality control when a CRM is unavailable or too costly for daily use. Before an in-house material goes into routine use, its homogeneity and stability over the intended storage period must be verified.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the definitions and the habits a laboratory professional is expected to know by heart.

Reference Materials Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: reference materials

A certified reference material carries certified values, uncertainty, traceability. A regular one may lack them: only the CRM anchors a traceability chain. Food labs use CRMs to verify accuracy and calibrate instruments. Traceability links a result to a reference through a documented chain of calibrations, each adding uncertainty.

ISO 17034 sets requirements for reference material producers. Every CRM comes with a certificate: values, uncertainties, storage, intended use, expiry. Check it first: in date, stored correctly, valid for the analyte and matrix. Certificates expire when stability fails or values are superseded.

Store materials by the certificate's conditions. Analyse the CRM alongside samples, so run bias shows. Plot CRM results on a QC chart to catch drift early. A secondary standard, calibrated against a CRM, preserves the CRM and gives traceable daily calibration. A matrix reference material matches the real sample, such as milk powder with certified lead.

An in-house reference material serves routine QC when no CRM is available or it costs too much. Before routine use, verify homogeneity and stability. Reference strains check that media and methods grow the target organisms. Commutability is how closely a material behaves like real samples. Monitor stability by re-analysis against fresh standards or trend review. Keep the record: identity, source, certificate, storage, expiry, usage log. If a CRM result falls outside its range, investigate, stop reporting, and correct the problem. If two CRMs conflict, check certificates, storage, preparation, method first.

Practical takeaway: check the certificate first, never report past a failed CRM.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: Why must the certificate of a CRM be checked before use?

  • A. The certificate of a CRM must be checked before use to practice paperwork
  • B. To confirm it is in date, stored correctly, and valid for the intended analyte and matrix
  • C. The certificate of a CRM must be checked before use to check the paper quality
  • D. The certificate of a CRM must be checked before use because certificates are decorative

Correct answer: To confirm it is in date, stored correctly, and valid for the intended analyte and matrix

ISO 17034:2016 requires every certified reference material to be supplied with a certificate stating certified values, uncertainties, storage conditions, intended use, and expiry. Checking the certificate before use confirms the material is still within its validity period, has been stored correctly, and matches the analyte and matrix you intend to test. Using an expired or mis-stored CRM invalidates the traceability chain.

Question 2: Stability monitoring of stored reference materials typically involves:

  • A. Stability monitoring of stored reference materials typically involves never testing them again
  • B. Periodic re-analysis against fresh standards or trend review of QC data
  • C. Stability monitoring of stored reference materials typically involves smelling them
  • D. Stability monitoring of stored reference materials typically involves changing the label

Correct answer: Periodic re-analysis against fresh standards or trend review of QC data

Reference material producers must run post-certification monitoring under ISO 17034:2016, and laboratories in turn re-analyse stored materials against freshly prepared standards or review their QC trend data. This detects any drift in the assigned values before they corrupt routine results. Smelling, relabelling, or never re-testing are not stability assessments.

Question 3: What should a lab do if a CRM result falls outside its certified range?

  • A. Investigate, stop reporting affected results, and correct the problem before proceeding
  • B. Ignore the failed result and simply carry on testing
  • C. Delete the result from the laboratory records entirely
  • D. Buy a brand-new replacement instrument immediately from suppliers

Correct answer: Investigate, stop reporting affected results, and correct the problem before proceeding

A CRM result outside its certified range signals possible analytical bias, so ISO/IEC 17025:2017 (clause 7.7) requires the laboratory to investigate, stop reporting affected results, and fix the problem before proceeding. Ignoring the failure or deleting the record would hide evidence of nonconformity. The CRM is the alarm, not the nuisance.

Question 4: Why do food labs use certified reference materials?

  • A. Food labs use certified reference materials because they are cheap
  • B. Food labs use certified reference materials to fill the certificate file
  • C. Food labs use certified reference materials to impress visitors
  • D. To verify method accuracy and calibrate instruments against a trusted standard

Correct answer: To verify method accuracy and calibrate instruments against a trusted standard

Certified reference materials carry property values with stated uncertainties and metrological traceability (ISO 17034:2016, ISO Guide 30:2015), so they provide a trustworthy benchmark for checking method accuracy and calibrating instruments. No amount of cheap or decorative alternatives can substitute for that documented link to a reference. They exist to prove results are right.

Question 5: The documentation for each reference material in use should include:

  • A. Only the purchase price on the invoice
  • B. Only the full name of the analyst using it
  • C. Identity, source, certificate, storage conditions, expiry and usage log
  • D. Nothing at all, since memory suffices for this

Correct answer: Identity, source, certificate, storage conditions, expiry and usage log

ISO 17034:2016 and ISO/IEC 17025:2017 expect full traceability of each reference material in use: its identity, source, certificate, storage conditions, expiry date, and a log of use. These records let auditors and analysts verify that the right material was used correctly at the time of testing. Price alone or memory alone is not a record.

Question 6: Before putting an in-house reference material into routine use, the laboratory should verify its:

  • A. Its color only
  • B. Its price
  • C. Homogeneity and stability over the intended storage period
  • D. Its country of origin

Correct answer: Homogeneity and stability over the intended storage period

Before an in-house material enters routine use, ISO Guide 80:2014 (in-house preparation of quality control materials) and ISO 17034:2016 require the laboratory to demonstrate that it is sufficiently homogeneous and remains stable over the intended storage period. Without that evidence, routine QC data built on the material are meaningless. Colour, price, and origin say nothing about fitness for purpose.

Question 7: For microbiological testing, reference strains (e.g., from culture collections) serve as reference materials to:

  • A. To calibrate balances
  • B. Verify that media and methods recover the target organisms
  • C. To measure pH
  • D. To count calories

Correct answer: Verify that media and methods recover the target organisms

In microbiological testing, reference strains from recognised culture collections act as reference materials that verify culture media and methods actually recover the target organisms : this is the basis of media performance testing in ISO 11133:2014. They have nothing to do with calibrating balances, measuring pH, or counting calories. A medium that cannot grow its reference strain cannot be trusted.

Question 8: How should reference materials be stored?

  • A. Reference materials should be stored on a sunny windowsill
  • B. Reference materials should be stored in the analyst's pocket
  • C. According to the certificate's storage conditions to preserve certified values
  • D. Reference materials should be stored next to the oven

Correct answer: According to the certificate's storage conditions to preserve certified values

Certified values are only valid while the material is kept within the storage conditions stated on its certificate, as required by ISO 17034:2016. Heat, light, or moisture can change composition and void the certification. A sunny windowsill, a pocket, or the side of an oven are storage failures, not storage conditions.

Question 9: ISO 17034 is the standard that specifies requirements for:

  • A. ISO 17034 is the standard that specifies requirements for food safety management
  • B. ISO 17034 is the standard that specifies requirements for laboratory safety showers
  • C. ISO 17034 is the standard that specifies requirements for packaging materials
  • D. Producers of reference materials, ensuring their competence and the quality of certified values

Correct answer: Producers of reference materials, ensuring their competence and the quality of certified values

ISO 17034:2016, 'General requirements for the competence of reference material producers', sets the requirements for bodies that produce reference materials, covering their competence and the quality of the certified values they assign. It is not about food safety management, safety showers, or packaging. Accreditation to ISO 17034 is what makes a CRM producer's certificates trustworthy.

Question 10: When two different CRMs for the same analyte give conflicting QC results, the laboratory should:

  • A. When two different CRMs for the same analyte give conflicting QC results, the laboratory should simply pick the result it prefers
  • B. Investigate, checking certificates, storage, preparation and method performance, before trusting either
  • C. When two different CRMs for the same analyte give conflicting QC results, the laboratory should discard both immediately
  • D. When two different CRMs for the same analyte give conflicting QC results, the laboratory should ignore both results and carry on

Correct answer: Investigate, checking certificates, storage, preparation and method performance, before trusting either

When two CRMs for the same analyte disagree, neither should be trusted until the laboratory investigates : checking certificates, expiry, storage, preparation, and method performance : as required by the measurement-assurance approach of ISO/IEC 17025:2017. Averaging or discarding blindly would hide the root cause. One of them is telling the truth; the investigation finds which.

Question 11: What is a certified reference material (CRM)?

  • A. A certified reference material (CRM) is a textbook
  • B. A certified reference material (CRM) is any chemical bought online
  • C. A reference material with certified property values, uncertainty, and metrological traceability
  • D. A certified reference material (CRM) is a lab notebook

Correct answer: A reference material with certified property values, uncertainty, and metrological traceability

ISO Guide 30:2015 defines a certified reference material as a reference material characterised by a metrologically valid procedure for one or more specified properties, accompanied by a certificate stating the certified value, its uncertainty, and metrological traceability. It is therefore a metrological tool, not a textbook, an online chemical, or a notebook. The certificate is what makes it 'certified'.

Question 12: Reference material certificates expire or are withdrawn when:

  • A. Stability can no longer be assured or the certified values are superseded
  • B. Reference material certificates expire or are withdrawn when the laboratory moves buildings
  • C. Reference material certificates expire or are withdrawn when a new analyst joins
  • D. Reference material certificates expire or are withdrawn when the price changes

Correct answer: Stability can no longer be assured or the certified values are superseded

ISO 17034:2016 requires producers to withdraw or expire certificates when stability can no longer be assured or when the certified values are superseded by newer characterisation. The certificate's validity is a scientific statement, not an administrative one. Moving buildings, new staff, or price changes have no bearing on it.

Question 13: What is metrological traceability?

  • A. Metrological traceability is a type of train
  • B. Metrological traceability is a software feature
  • C. The property linking a measurement result to a reference through an unbroken chain of calibrations
  • D. Metrological traceability is a lab rumor

Correct answer: The property linking a measurement result to a reference through an unbroken chain of calibrations

Metrological traceability is defined in the International Vocabulary of Metrology (JCGM 200:2012, the VIM) as the property of a measurement result whereby the result can be related to a reference through a documented, unbroken chain of calibrations, each contributing to the measurement uncertainty. It is a measurement concept, not a train, a software feature, or a rumour. Every link in the chain must be documented.

Question 14: When should a CRM be analyzed in an analytical run?

  • A. Alongside samples, so any bias in that run is detected
  • B. Only on holidays is when should a CRM be analyzed in an analytical run
  • C. After results are reported is when should a CRM be analyzed
  • D. Never is when should a CRM be analyzed in an analytical run

Correct answer: Alongside samples, so any bias in that run is detected

Analysing the CRM in the same run as the samples exposes the CRM to exactly the same reagents, instruments, and conditions, so any bias in that run shows up in the CRM result. This run-level control is the core of internal quality control under ISO/IEC 17025:2017 (clause 7.7). A CRM analysed only on holidays, after reporting, or never provides no such protection.

Question 15: What is a matrix reference material in food analysis?

  • A. A reference material with a food-like matrix, e.g. milk powder with certified lead content
  • B. A protective laboratory coat worn daily by the analysts on duty
  • C. A reference to a famous movie scene about food safety
  • D. A spreadsheet holding all the laboratory test results together neatly

Correct answer: A reference material with a food-like matrix, e.g. milk powder with certified lead content

A matrix reference material matches the composition of the real sample : for example, a milk powder with a certified lead content : so it experiences the same matrix effects during preparation and measurement. This makes method validation and QC far more realistic than testing a pure solution. Coats, movie references, and spreadsheets are not reference materials.

Question 16: What is commutability of a reference material?

  • A. How closely it behaves like real patient or food samples in the measurement procedure
  • B. Commutability of a reference material is its brand
  • C. Commutability of a reference material is its weight
  • D. Commutability of a reference material is its price

Correct answer: How closely it behaves like real patient or food samples in the measurement procedure

Commutability describes how closely a reference material behaves like real patient or food samples in a given measurement procedure, a property addressed in ISO 17034:2016. A commutable CRM gives confidence that the calibration applies to actual samples. Brand, weight, and price are commercial attributes, not metrological ones.

Question 17: What is the difference between a CRM and a regular reference material?

  • A. The difference between a CRM and a regular reference material is the container size
  • B. The difference between a CRM and a regular reference material is the price tag
  • C. The difference between a CRM and a regular reference material is the color
  • D. A CRM has certified values with stated uncertainty and traceability; a regular RM may not

Correct answer: A CRM has certified values with stated uncertainty and traceability; a regular RM may not

The difference is certification: a CRM is characterised by a metrologically valid procedure with certified values, stated uncertainties, and metrological traceability (ISO Guide 30:2015; ISO 17034:2016), while a regular reference material may lack one or all of these. Only the CRM can anchor a traceability chain. Container size, price tag, and colour are irrelevant.

Question 18: Plotting CRM results on a QC chart helps the laboratory:

  • A. Decorate the wall
  • B. Detect analytical drift or bias shifts early
  • C. Avoid proficiency testing
  • D. Reduce staff

Correct answer: Detect analytical drift or bias shifts early

Plotting CRM results on a control chart applies the statistical tools of the ISO 7870 series to the laboratory's own data, so gradual drift or sudden bias shifts appear as trends or out-of-control points long before they corrupt reported results. It is an early-warning system, not decoration, and it never replaces proficiency testing or reduces staff.

Question 19: A secondary (working) standard calibrated against a CRM is useful because it:

  • A. It has higher authority than the CRM
  • B. It needs no documentation
  • C. A secondary (working) standard calibrated against a CRM is too unreliable for daily use
  • D. Preserves the expensive CRM while providing traceable daily calibration

Correct answer: Preserves the expensive CRM while providing traceable daily calibration

A secondary (working) standard calibrated against a CRM inherits metrological traceability through the calibration chain (ISO/IEC 17025:2017, clause 6.4.6), so it can be used for daily calibration while the expensive CRM stays sealed and stable. This preserves the primary reference and its certified values. It has no higher authority than the CRM and still needs documentation.

Question 20: An in-house (working) reference material is prepared by a laboratory to:

  • A. An in-house (working) reference material is prepared by a laboratory to replace certified reference materials entirely
  • B. An in-house (working) reference material is prepared by a laboratory to calibrate balances
  • C. An in-house (working) reference material is prepared by a laboratory to avoid all documentation
  • D. Provide a stable, homogeneous material for routine QC when a CRM is unavailable or too costly for daily use

Correct answer: Provide a stable, homogeneous material for routine QC when a CRM is unavailable or too costly for daily use

ISO Guide 80:2014 recognises in-house (working) reference materials as stable, homogeneous materials a laboratory prepares for routine quality control when a CRM is unavailable or too costly for daily use. They support day-to-day monitoring but cannot replace CRMs for traceability or method validation. Skipping documentation or calibration duties would defeat their purpose.