Precision Quiz
GIFSQ ID: ART-1439
Test your knowledge with this free 20-question Precision quiz from Food Analysis & Analytical Chemistry, part of…
What this quiz covers
Precision is the quiet half of measurement quality: not whether a result is right, but whether repeated results agree with each other. This quiz pins down that idea and the family of terms around it. Precision means closeness of repeated measurements to each other, and it is usually expressed as a standard deviation or a relative standard deviation. Repeatability is precision under the same conditions, the same analyst, equipment and a short time. Intermediate precision covers variation inside one laboratory over days, analysts and equipment, and reproducibility is precision under changed conditions, different laboratories, analysts or equipment. Reporting a mean with its standard deviation communicates both the result and its precision in one line, and pooling data across analysts tests intermediate precision, the method’s robustness to who performs it.
The quiz also covers why precision behaves the way it does. Increasing replicates improves the precision of the mean, because the standard error falls with the square root of n. The Horwitz equation predicts that relative standard deviation rises as analyte concentration falls, so trace analysis is held to looser limits than major component analysis, where method validation often asks for RSD below about 5 percent. Poor precision with good accuracy points to random error: inhomogeneous samples, unstable instruments or inconsistent technique, and sample inhomogeneity shows up directly as poor repeatability between test portions of the same sample. Pipetting technique matters for the same reason, since inconsistent volumes scatter results. Control charts of check standards watch ongoing precision and bias day by day, and regulatory methods prescribe precision criteria so results stay comparable and legally defensible across laboratories.
Precision is about scatter, not truth
A precise but inaccurate method is reliably wrong: the replicates cluster tightly around the wrong value, useful only after the bias is corrected. That is why a low RSD of 1 percent is good news about scatter and says nothing on its own about trueness, and why precision matters for specification compliance: with wide scatter, some passing results are luck, and decisions built on them become unreliable.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the definitions and numbers a food analyst is expected to know by heart.
Choose how you want to play
A short note: precision
Precision is how closely repeated measurements agree with each other, wherever the cluster sits against the true value. ISO 5725 calls closeness to the true value trueness; accuracy combines trueness and precision. Precision is expressed as standard deviation, or as RSD: SD divided by the mean, times 100 percent. A 1 percent RSD means tight replicates, but says nothing about accuracy.
Repeatability holds everything identical: same analyst, equipment, laboratory, short time. Intermediate precision spans variation within one lab over time: different days, analysts, and equipment. Reproducibility is precision across changed conditions: other laboratories, analysts, and equipment. It is always wider than repeatability: every changed condition adds variance.
Poor precision comes from inhomogeneous samples, unstable instruments, and inconsistent technique. Inhomogeneity shows up as poor repeatability between test portions. Pipetting scatters results when volumes are inconsistent. A precise but inaccurate method stays reliably wrong until bias is corrected. Poor precision with good accuracy means random error dominates: tighten technique, homogenisation, or instrument stability.
More replicates sharpen the mean: standard error falls with the square root of n. The Horwitz equation predicts that RSD increases as analyte concentration decreases. Validation acceptance is often RSD below method limits, such as 5 percent for major components. Control charts of check standards monitor ongoing precision and bias. Precision matters for compliance: with wide scatter, some passing results are just luck.
Practical takeaway: report the mean with its SD, and fix scatter at its source, not by averaging it away.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: Reporting the mean ± SD communicates:
Correct answer: Both the result and its precision
Reporting the mean ± standard deviation gives two facts in one: the central result and the spread of the data behind it. A moisture result of 12.4 ± 0.1% tells a very different story from 12.4 ± 1.2% : the first is a tight, trustworthy number, the second a warning : which is why analytical reports pair them (EURACHEM/CITAC Guide CG4 on measurement uncertainty, 2012).
Question 2: Precision in analysis means:
Correct answer: Closeness of repeated measurements to each other
Precision is agreement among repeated measurements of the same thing : tight clustering : regardless of where the cluster sits relative to the true value. ISO 5725 defines it this way, reserving 'trueness' for closeness to the true value; accuracy is the combination of both.
Question 3: Control charts of check standards monitor:
Correct answer: Ongoing precision (and bias) of the analytical process
A check standard run with every batch and plotted on a control chart reveals drift and shifts: points hugging the center line mean a stable process, while a trend or an out-of-limits point flags a process going off track. The chart monitors the analytical process itself : precision and bias together : not the sample.
Question 4: Increasing replicates improves:
Correct answer: The precision of the mean, standard error falls with √n
Averaging n replicates shrinks the standard error of the mean by √n: quadrupling replicates halves the uncertainty of the reported average. It sharpens the precision of the mean only : systematic bias survives averaging untouched, which is why replication never fixes an inaccurate method.
Question 5: The main sources of poor precision include:
Correct answer: Inhomogeneous samples, unstable instruments, inconsistent technique
Scatter comes from three classic sources: inhomogeneous test portions (each scoop differs), drifting instruments, and inconsistent analyst technique. ISO 5725's precision experiments are designed to separate exactly these contributions : repeatability, intermediate precision, reproducibility.
Question 6: Sample inhomogeneity shows up as:
Correct answer: Poor repeatability between test portions of the same sample
If the sample is not uniform, each test portion is effectively a different sample, so replicate results scatter even when the method is perfect. That poor repeatability between portions of the 'same' sample is the signature of inhomogeneity : fixed by grinding, mixing and riffling, not by a better instrument.
Question 7: Repeatability is precision under:
Correct answer: The same conditions, analyst, equipment, short time
Repeatability is precision under identical conditions: same analyst, same equipment, same laboratory, short time interval. ISO 5725 defines it as the tightest precision tier : the best a method can do before day-to-day and lab-to-lab variation enter.
Question 8: Instrumental precision is checked by:
Correct answer: Repeated measurement of the same standard
Instrumental precision is checked by measuring the same stable standard repeatedly and computing the spread : for example, ten absorbance readings of one solution on a spectrophotometer. The result isolates the instrument's own noise from sample and operator effects.
Question 9: A precise but inaccurate method is:
Correct answer: Reliably wrong, useful only after bias correction
A method that clusters tightly around the wrong value is precisely wrong : but because the error is systematic, a measured bias correction rescues it. Uncorrected it misleads; corrected it becomes accurate. Random scatter, by contrast, cannot be corrected away.
Question 10: Regulatory methods prescribe precision criteria so that:
Correct answer: Results are comparable and legally defensible across laboratories
Regulations prescribe precision limits : repeatability and reproducibility values : so that two accredited laboratories testing the same lot reach the same verdict. Without them, a 14.0% moisture limit means nothing: one laboratory's 13.8 and another's 14.2 would both claim to be right, and enforcement would collapse.
Question 11: Pooling data across analysts tests:
Correct answer: Intermediate precision, the method's robustness to who performs it
Pooling results across analysts measures intermediate precision : how much the result moves when the hands change but the laboratory and method stay. A method that only works for one gifted analyst is not a validated method; robustness to who performs it is an explicit validation parameter (ICH Q2(R2), 2023).
Question 12: Method validation acceptance for precision is often:
Correct answer: RSD below method-appropriate limits, e.g. ≤5% for major components
Validation guidelines expect precision fit for purpose: for major components at percent levels, repeatability RSDs around 1, 5% are typical acceptance territory (AOAC Appendix F; the Horwitz equation predicts roughly 2, 4% RSD at 1, 10% concentration). Trace analysis accepts larger RSDs : the limit scales with concentration.
Question 13: Poor precision with good accuracy suggests:
Correct answer: Random error dominates, improve technique, homogenisation or instrument stability
When the average lands on target but individual results scatter, systematic bias is absent and random error dominates : noisy instrument, sloppy pipetting, inhomogeneous portions. The fix targets the random sources: homogenize better, stabilize the instrument, tighten technique.
Question 14: Intermediate precision covers:
Correct answer: Within-lab variation over time, different days, analysts, equipment
Intermediate precision spans within-laboratory variation across time: different days, analysts and equipment, same method and laboratory. It sits between repeatability (same everything) and reproducibility (different laboratories) in the ISO 5725 hierarchy, and it is what a single laboratory's control chart actually demonstrates.
Question 15: Pipetting technique affects precision because:
Correct answer: Inconsistent volumes scatter results
Every pipetting step multiplies volume error into the final result: inconsistent draw, angle, drainage time or tip wetting scatters delivered volumes, and the scatter propagates through dilutions into the reported value. Calibrated micropipettes and disciplined technique are precision infrastructure.
Question 16: Horwitz equation predicts that RSD:
Correct answer: Increases as analyte concentration decreases
The Horwitz equation (Horwitz et al., 1980, J. AOAC) predicts interlaboratory RSD from concentration alone: RSD roughly doubles for each 100-fold drop in concentration. It is why trace pesticide analysis accepts 20%+ RSD while a 50% protein assay must hold a few percent : expectations follow the curve.
Question 17: Precision is usually expressed as:
Correct answer: Standard deviation or relative standard deviation (RSD)
Precision is quantified as the standard deviation of replicates, or the relative standard deviation (RSD = SD ÷ mean × 100%) when comparing across concentration levels. Both describe spread; neither says anything about closeness to the true value.
Question 18: A low RSD (e.g. 1%) indicates:
Correct answer: Good precision, tight replicates
An RSD of 1% means the replicates cluster within about one percent of the mean : tight, repeatable data. It speaks only to precision, not accuracy: a 1% RSD method can still sit 10% off the true value if a bias lurks underneath.
Question 19: Reproducibility is precision under:
Correct answer: Changed conditions, different labs, analysts or equipment
Reproducibility is precision under changed conditions : different laboratories, analysts and equipment running the same method. ISO 5725's collaborative trials measure it directly, and it is always wider than repeatability because every changed condition adds its own variance.
Question 20: Why does precision matter for specification compliance?
Correct answer: Wide scatter means some 'passing' results are luck, decisions become unreliable
A specification decision is only as good as the measurement behind it: with wide scatter, a 'passing' result may be a lucky draw from a failing lot, and a 'failing' result an unlucky one. Tight precision is what makes pass/fail decisions : and the legal actions built on them : defensible.