FTIR Quiz
GIFSQ ID: ART-1422
Test your knowledge with this free 20-question FTIR quiz from Food Analysis & Analytical Chemistry, part of…
What this quiz covers
FTIR identifies food components because molecules absorb infrared radiation at frequencies matching their bond vibrations, and this quiz covers the instrument and its food uses. It opens with the principle itself and the mid-infrared region, about 4000 to 400 wavenumbers, where fundamental vibrations give sharp, intense bands that can be assigned to specific functional groups. The Michelson interferometer encodes every IR frequency into a single interferogram at once, and the Fourier transform turns that interferogram into the spectrum.
The middle questions are the sampling choices: the KBr pellet, where a dry solid is ground with dry potassium bromide and pressed into a transparent disc, and ATR, where the sample is simply pressed against a crystal with little or no preparation, a liquid oil placed neat and undiluted. A background spectrum subtracts absorptions from air, water vapor and the instrument, baseline correction removes sloping baselines from scattering and drift, and co-adding scans improves the signal-to-noise ratio. Water is the hard matrix component because it absorbs mid-IR very strongly and can mask analyte bands.
A fingerprint, not a photograph: the spectrum names the bonds
The set closes with the assignments a food analyst reads off a spectrum: the ester carbonyl near 1740 wavenumbers for oil and fat, the amide I band near 1650 for protein backbone carbonyl stretching, the trans fat band near 966, and the fingerprint region from 1500 to 400, crowded with bending vibrations unique to each molecule. Quantitative work relies on chemometric calibrations such as PLS built against reference-method data, and a model applied to a new product type must be validated or recalibrated, because matrix changes alter spectral response.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the wavenumbers, sampling methods and calibration rules a candidate is expected to know by heart.
Choose how you want to play
A short note: FTIR spectroscopy
FTIR identifies food components because molecules absorb infrared light at frequencies matching their bond vibrations. The mid-infrared region spans 4000 to 400 cm⁻¹. The Michelson interferometer encodes every IR frequency at once for Fourier transformation. Mid-IR spectra show sharper bands than near-infrared, easier to assign to functional groups. The fingerprint region, 1500 to 400 cm⁻¹, holds bending vibrations unique to each molecule.
Water absorbs IR very strongly and can mask analyte bands. A background spectrum subtracts absorptions from air, water vapour and the instrument. Baseline correction takes out sloping baselines from scattering and drift. Resolution, for example 4 cm⁻¹, sets how closely spaced bands can be distinguished. Co-adding more scans improves the signal-to-noise ratio.
Sampling is easy: ATR needs little preparation, the sample pressed against a crystal, and liquid oil goes on neat. The KBr pellet grinds dry solid with potassium bromide and presses a transparent disc.
Quantitative FTIR of fat, protein and moisture relies on chemometric calibrations such as PLS built against reference data. A model used on a new product type must be validated or recalibrated. A band near 1740 cm⁻¹ in oil is ester C=O stretching of triglycerides; trans fats show a band near 966 cm⁻¹. The amide I band near 1650 cm⁻¹ is C=O stretching of the peptide backbone. Oil oxidation shows as growth of hydroperoxide and carbonyl bands. Added water or starch changes milk's spectrum, so FTIR can flag adulteration.
Practical takeaway: dry the sample, collect a background, and recalibrate for new matrices.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: KBr pellet preparation is a classical FTIR transmission technique in which:
Correct answer: A small amount of solid sample is ground with dry potassium bromide and pressed into a transparent disc
The KBr pellet technique grinds a small amount of dry solid sample with dry potassium bromide : which is transparent in the mid-IR : and presses the mixture under high pressure into a clear disc for transmission measurement. Water would dissolve the pellet, burning destroys the sample, and liquids are not injected into the beam.
Question 2: FTIR can help detect adulteration of milk with added water or starch because:
Correct answer: Adulterants change the spectrum in detectable ways versus authentic milk
Added water or starch changes the milk's infrared spectrum : water shifts the O, H region and dilutes the fat/protein bands, starch adds its own carbohydrate absorptions : so the spectrum deviates measurably from authentic milk. FTIR detects adulteration through these spectral changes, not by counting colonies or radioactivity.
Question 3: In an FTIR instrument, the interferometer (Michelson interferometer) is used to:
Correct answer: Encode all IR frequencies simultaneously so the spectrum is obtained by Fourier transformation
The Michelson interferometer encodes every IR frequency into a single interferogram simultaneously (the multiplex/Fellgett advantage); the Fourier transform then converts that interferogram into the spectrum. It does not focus, heat, or fractionate the sample.
Question 4: A strong absorption band near 1740 cm⁻¹ in an edible oil spectrum is assigned to:
Correct answer: C=O stretching of ester (triglyceride) groups
Ester carbonyl (C=O) stretching in triglycerides absorbs strongly around 1740, 1750 cm⁻¹, making this band the standard marker for oil/fat content. O, H and N, H stretches appear near 3300 cm⁻¹, and C, Cl absorbs at far lower wavenumbers.
Question 5: Water is a difficult matrix component in mid-IR analysis because water:
Correct answer: Absorbs IR radiation very strongly and can mask analyte bands
Water absorbs mid-IR radiation intensely (strong O, H stretching near 3400 cm⁻¹ and bending near 1640 cm⁻¹), so in aqueous samples it can swamp the analyte bands : the classic reason IR of foods needs short pathlengths or ATR. It does not lack absorption, evaporate in the spectrometer, or damage the detector.
Question 6: Spectral resolution in FTIR (for example 4 cm⁻¹) determines:
Correct answer: How closely spaced absorption bands can be distinguished
Resolution, e.g. 4 cm⁻¹, is the smallest wavenumber separation at which two adjacent bands can still be distinguished as separate peaks. It is a property of the interferometer's mirror travel, not scan speed, sample temperature, or detector type.
Question 7: Quantitative FTIR analysis of fat, protein and moisture in foods normally relies on:
Correct answer: Chemometric calibrations (such as PLS) built against reference-method data
Food matrices are too complex for a single universal equation, so quantitative FTIR uses chemometric calibrations : typically partial least squares (PLS) regression : built from spectra paired with reference-method values (e.g. Kjeldahl for protein). Visual comparison or single-wavelength reading cannot give validated numbers.
Question 8: When an FTIR quantitative model is applied to a new product type it was not calibrated on, the analyst should:
Correct answer: Validate or recalibrate the model, as matrix changes alter spectral response
A chemometric model only knows the matrices it was calibrated on; a new product type brings different spectral interferences, so the model must be validated and usually recalibrated for it. More scans improve precision, not matrix mismatch, and changing spectrometer brand does not fix a calibration gap.
Question 9: Oxidation of edible oils during storage can be followed by FTIR through:
Correct answer: Growth of bands from hydroperoxides and carbonyl oxidation products
As oils oxidize, hydroperoxides form (O, H band growth near 3444 cm⁻¹) and break down into aldehydes and ketones that add carbonyl absorption : these growing bands are the FTIR markers of oxidation. C, H bands do not vanish, and the fingerprint region remains.
Question 10: The mid-infrared region most used in food FTIR analysis spans approximately:
Correct answer: 4000 to 400 cm⁻¹
The mid-infrared : the fundamental vibration region used in food FTIR : spans approximately 4000 to 400 cm⁻¹. 200, 400 nm is the UV, 14000, 4000 cm⁻¹ is the near-IR, and 10, 100 MHz is radiofrequency.
Question 11: Increasing the number of scans co-added in an FTIR measurement mainly:
Correct answer: Improves the signal-to-noise ratio
Co-adding N scans averages out random noise while the signal adds coherently, so the signal-to-noise ratio improves (with √N) : the standard way to clean up a weak spectrum. It does not shift peaks, change chemistry, or reduce resolution.
Question 12: A background (blank) spectrum is collected in FTIR to:
Correct answer: Subtract absorptions from air, water vapor and the instrument itself
The background (blank) spectrum records absorptions from atmospheric water vapour, CO₂, and the instrument optics themselves; ratioing the sample spectrum against it subtracts these contributions. It does not calibrate the wavenumber scale, measure thickness, or boost detector voltage.
Question 13: In protein analysis by FTIR, the amide I band (around 1650 cm⁻¹) arises mainly from:
Correct answer: C=O stretching of the peptide backbone
The amide I band near 1650 cm⁻¹ arises mainly from C=O stretching of the peptide backbone (with minor C, N contributions), and its exact position reports protein secondary structure. N, H stretching is the amide A/B region, S, H and C, H vibrations lie elsewhere.
Question 14: Fourier transform infrared (FTIR) spectroscopy identifies food components because molecules:
Correct answer: Absorb infrared radiation at frequencies matching their bond vibrations
FTIR works because each molecular bond vibrates at characteristic frequencies and absorbs infrared radiation at matching wavenumbers : the absorption pattern is the molecule's fingerprint. Molecules do not emit visible light, become radioactive, or change colour under IR.
Question 15: Trans fats in edible oils can be detected by FTIR using the characteristic band near:
Correct answer: 966 cm⁻¹
Isolated trans double bonds show a characteristic C, H out-of-plane deformation band near 966 cm⁻¹, the basis of the standard IR method for trans fats in oils (AOCS/ISO methodology). The other listed positions correspond to O, H/N, H stretches, triple bonds, and the far-IR.
Question 16: Compared with near-infrared (NIR), mid-IR FTIR spectra of foods generally show:
Correct answer: Sharper, more resolved fundamental bands that are easier to assign to functional groups
Mid-IR records fundamental vibrations, which are sharp, intense, and well separated, so bands can be assigned to specific functional groups; NIR records weak, broad overtones and combinations that need heavy chemometrics. The other options misstate this basic contrast.
Question 17: The 'fingerprint region' of an IR spectrum (about 1500 to 400 cm⁻¹) is valuable because:
Correct answer: It contains complex bending vibrations unique to each molecule, aiding identification
The 1500, 400 cm⁻¹ fingerprint region is crowded with complex bending and skeletal vibrations that differ from molecule to molecule, giving each compound a unique pattern used for identification. It is neither empty nor water-only, and it measures nothing about temperature.
Question 18: For FTIR analysis, a liquid oil sample measured by ATR should be:
Correct answer: Placed neat (undiluted) in good contact with the ATR crystal
ATR needs only intimate optical contact between sample and crystal: a liquid oil is placed neat (undiluted) on the crystal, and the evanescent wave probes it directly. Dilution, boiling, or mixing with KBr would defeat the technique's whole point.
Question 19: Attenuated total reflectance (ATR) sampling is popular for foods because it:
Correct answer: Needs little or no sample preparation, the sample is simply pressed against a crystal
ATR is popular for foods precisely because it needs little or no sample preparation : the sample is simply pressed against the internal-reflection crystal. It does not require KBr dissolution, is not limited to gases, and does not destroy the sample.
Question 20: Baseline correction is applied to FTIR spectra to:
Correct answer: Remove sloping or offset baselines caused by scattering and instrument drift
Baseline correction removes the sloping or offset baselines caused by scattering (common in food samples) and instrument drift, so peak heights and areas can be measured accurately. It does not add water bands, convert units to pH, or identify the operator.