Food Technology Loksewa – Microbiological Analysis
GIFSQ ID: ART-1204
Test your knowledge with this free 20-question Microbiological Analysis quiz from Food Analysis & Laboratory, part of…
What this quiz covers
This Loksewa set is microbiological analysis, and its first half is a different kind of analysis from plate counting: the microbiological assay of vitamins and amino acids. The principle is elegant, a test organism that cannot make the vitamin is grown in a medium that contains everything except that vitamin, so its growth is limited by the vitamin dose alone and rises in proportion to it. The questions then ask for the compendial test organism for each vitamin, and the list is worth learning as a set: Lactobacillus delbrueckii subsp. lactis ATCC 7830 for B12, Lactobacillus plantarum ATCC 8014 for niacin, biotin and pantothenic acid, Lactobacillus casei subsp. rhamnosus ATCC 7469 for riboflavin and folic acid, and Lactobacillus fermentum for thiamine.
The second half of the set is the counting laboratory: total plate count on plate count agar, the 25 to 250 colony range for a valid plate, the most probable number technique for coliforms with gas in Durham tubes, violet red bile agar for coliforms, pre-enrichment in buffered peptone water to resuscitate injured Salmonella, Baird-Parker agar with the coagulase test for Staphylococcus aureus, potato dextrose agar at 25 C for five days for yeasts and moulds, and the autoclave at 121 C and 15 psi for 15 to 20 minutes. Growth in the assay half is read by turbidity or by titrating the lactic acid the lactobacilli produce.
One missing nutrient makes the whole assay work
Every microbiological assay runs on a single deliberate gap. The basal medium supplies all the growth essentials except the one compound being assayed, so that compound alone limits growth, and the organism’s growth becomes a measuring instrument for it. That is why the assays are so sensitive: the test organisms need these growth factors only in micro- or nano-gram amounts. Add a known series of vitamin doses, read the turbidity or titrate the lactic acid produced, and the dose-response curve reads the vitamin content of the sample, with a precision no chemical method of the same era could match.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the numbers and definitions a food technologist is expected to know by heart.
Choose how you want to play
A short note: microbiological analysis of foods
Microbiological analysis counts and identifies microbes in food, and one tool is the microbiological assay of vitamins. The assay works because a test organism grows in proportion to the vitamin added. The basal medium contains everything except the vitamin. Growth is read by turbidity at 660 nanometres, or by titrating the lactic acid produced. The method is highly sensitive because the organisms need these factors in micro- or nano-gram amounts.
Each vitamin has its own test organism. Vitamin B12 is assayed with Lactobacillus delbrueckii ATCC 7830. Niacin, biotin and pantothenic acid are assayed with Lactobacillus plantarum ATCC 8014. Riboflavin and folic acid are assayed with Lactobacillus rhamnosus ATCC 7469. Thiamine is assayed with Lactobacillus fermentum. The same principle assays amino acids: the medium lacks only the amino acid being measured.
Routine food testing uses plate counts. Total plate count uses plate count agar at 35 degrees for 48 hours or 30 degrees for 72 hours, counting plates with 25 to 250 colonies. Coliforms are estimated by the most probable number technique, from gas production in Durham tubes, or counted on violet red bile agar with an overlay. Salmonella detection starts with pre-enrichment in buffered peptone water. Staphylococcus aureus is counted on Baird-Parker agar, confirmed by coagulase test. Potato dextrose agar is used to count yeasts and moulds, held at 25 degrees for 5 days. Autoclave sterilisation is 121 degrees at 15 psi for 15 to 20 minutes.
Remember: count only plates with 25 to 250 colonies, and pre-enrich Salmonella samples.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: The basic principle of the microbiological assay of a vitamin is that:
Correct answer: The growth of the test organism is proportional to the amount of the vitamin added to the medium
The assay uses a test organism auxotrophic for the vitamin, so its growth : and only its growth : is limited by the vitamin dose, giving a proportional dose, response curve. The organism does not synthesise the vitamin in fixed amounts, turbidity rises (not falls) with growth, and the vitamin nourishes rather than kills it.
Question 2: The test organism used for the microbiological assay of vitamin B12 is:
Correct answer: Lactobacillus delbrueckii subsp. lactis (ATCC 7830)
The compendial B12 test organism is Lactobacillus delbrueckii subsp. lactis ATCC 7830 : the current name of the classic Lactobacillus leichmannii ATCC 7830 (USP <171> Vitamin B12 Activity Assay, AOAC 952.20). The other options are organisms for different vitamin assays or unrelated QC strains.
Question 3: The official test organism for the microbiological assay of niacin is:
Correct answer: Lactobacillus plantarum ATCC 8014
The official niacin assay organism is Lactobacillus plantarum ATCC 8014 (AOAC 944.13). Streptomyces griseus, Saccharomyces cerevisiae, and the B12 organism are not the niacin test strain.
Question 4: Biotin, niacin and pantothenic acid can all be assayed microbiologically using:
Correct answer: Lactobacillus plantarum ATCC 8014
Lactobacillus plantarum ATCC 8014 is auxotrophic for biotin, niacin, and pantothenic acid alike, so the one strain serves all three compendial microbiological assays. Aspergillus niger, Bacillus thuringiensis, and Streptomyces griseus are not vitamin assay organisms for these nutrients.
Question 5: Riboflavin (vitamin B2) is assayed microbiologically with the test organism:
Correct answer: Lactobacillus casei subsp. rhamnosus ATCC 7469
Riboflavin is assayed with Lactobacillus casei subsp. rhamnosus ATCC 7469 (AOAC 940.33). Streptococcus faecalis, Lactobacillus plantarum, and Bacillus subtilis are not the riboflavin test organism.
Question 6: Folic acid in foods is assayed microbiologically with:
Correct answer: Lactobacillus rhamnosus ATCC 7469
Folic acid is assayed microbiologically with Lactobacillus rhamnosus ATCC 7469 : the modern name of the strain that older method editions cite as Lactobacillus casei subsp. rhamnosus. Aspergillus niger, Escherichia coli, and Candida albicans are not folate assay organisms.
Question 7: Thiamine (vitamin B1) is assayed microbiologically with:
Correct answer: Lactobacillus fermentum
Thiamine is assayed with Lactobacillus fermentum (AOAC 942.23). Leuconostoc mesenteroides, Lactobacillus plantarum, and Lactobacillus casei are test organisms for other assays.
Question 8: In the microbiological assay of B vitamins, the growth response of the test organism is usually measured by:
Correct answer: Measuring the turbidity produced by microbial growth, or by titrating a metabolite such as lactic acid
Growth is read either turbidimetrically or acidimetrically : by titrating the lactic acid the lactobacilli produce : both standard readouts. Viral plaque counts, oxygen consumption alone, and Gram-stained cell counts are not the assay readout.
Question 9: In the microbiological assay of an amino acid, the assay medium:
Correct answer: Contains all nutrients except the amino acid being assayed
The medium must contain every nutrient except the amino acid under test, so that amino acid alone limits growth and the response tracks its amount. A medium with no carbon source, no amino acids at all, or an excess of the target cannot produce a dose response.
Question 10: The basal medium used in a microbiological vitamin assay:
Correct answer: Contains all compounds essential for growth apart from the vitamin in question
The basal medium supplies all growth essentials except the vitamin being assayed, making the vitamin the single growth-limiting factor. Antibiotics would kill the test organism, double vitamin removes the limitation, and a nutrient-free medium supports no growth.
Question 11: In the turbidimetric form of the microbiological assay, growth of the test organism is commonly read as:
Correct answer: Percent transmittance or absorbance with a spectrophotometer, for example at 660 nm
In the turbidimetric form, growth is read as percent transmittance or absorbance on a spectrophotometer, commonly at 660 nm. Colony counts, gas volumes, and zones of inhibition belong to other methods.
Question 12: The high sensitivity of microbiological assays comes from the fact that the test organisms require these growth factors in:
Correct answer: Micro- or nano-gram amounts
The test organisms need these growth factors only in micro- to nano-gram amounts, and that extreme requirement is exactly what makes the assay so sensitive. Gram or kilogram amounts would make it crude, and “dry powders only” is meaningless.
Question 13: Total plate count (aerobic colony count) of a food is determined on:
Correct answer: Plate count agar, incubated at 35 °C for 48 hours (or 30 °C for 72 hours)
The aerobic colony count is done on plate count agar at 35 °C for 48 hours (or 30 °C for 72 hours) per the FDA Bacteriological Analytical Manual. Blood agar at 4 °C, violet red bile agar, and potato dextrose agar at 55 °C are wrong medium, temperature combinations for this count.
Question 14: In a valid plate count, only plates with colony numbers in which range are counted?
Correct answer: 25, 250
Only plates with 25, 250 colonies are statistically valid (FDA BAM): fewer colonies give poor precision and crowded plates cannot be counted accurately. Single-digit, thousand-plus, or “any number” ranges are not accepted.
Question 15: The most probable number (MPN) technique for coliforms is based on:
Correct answer: Gas production from lactose in Durham tubes across replicate broth tubes
The MPN method inoculates replicate tubes of lactose broth with Durham tubes and scores gas production; the pattern of positive tubes is read against a statistical table. pH change or turbidity alone, and direct colony counting, are not the MPN basis.
Question 16: Violet red bile agar (VRBA) with an overlay is used for:
Correct answer: Enumeration of coliforms
Violet red bile agar with an overlay is the selective medium for enumerating coliforms : bile salts and crystal violet suppress Gram-positives while lactose fermenters form typical colonies. Salmonella enrichment, yeast and mould counts, and anaerobic spore counts use different media.
Question 17: For Salmonella detection, the sample is first incubated in buffered peptone water. This step is:
Correct answer: Pre-enrichment to resuscitate injured cells
Buffered peptone water is the non-selective pre-enrichment that lets heat- or processing-injured Salmonella cells resuscitate before selective enrichment. It is not a confirmation step, not selective, and not serotyping.
Question 18: Staphylococcus aureus is enumerated on Baird, Parker agar and confirmed by:
Correct answer: The coagulase test
Baird, Parker agar isolates Staphylococcus aureus, and the coagulase test confirms it by clotting plasma : the defining trait. Gas from glucose, the oxidase test, and motility do not identify S. aureus, which is non-motile.
Question 19: Yeasts and moulds in foods are commonly counted on potato dextrose agar incubated at:
Correct answer: 25 °C for 5 days
Yeasts and moulds are counted on potato dextrose agar at 25 °C for 5 days (FDA BAM). Fifty-five degrees for hours, refrigeration temperatures, and 37 °C for 24 hours are the wrong conditions for this count.
Question 20: Standard steam sterilisation in an autoclave is:
Correct answer: 121 °C at 15 psi for 15, 20 minutes
Standard steam sterilisation is 121 °C at 15 psi for 15, 20 minutes, which reliably kills spores. Boiling at 100 °C for 10 minutes does not, 160 °C for an hour is a dry-heat regime, and 63 °C for 30 minutes is pasteurisation.