Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Food Technology Loksewa – Food Sampling

GIFSQ ID: ART-1221

Test your knowledge with this free 20-question Food Sampling quiz from Nepal Food Laws & Regulations, part…

What this quiz covers

This set is about the sample itself: how much to take, how to take it, and how to keep it honest on the way to the laboratory. It opens in Schedule-3 of the rules, where quantities are fixed: for foods the schedule does not list, about 250 grams or 250 millilitres, and when a sample is taken for pesticide, mycotoxin or radiation testing, the stated quantity goes up by 500 grams. A sample seized under a sale-ban order must be tested so the report arrives within 15 days, the same deadline Section 33 of the 2081 Act sets.

The next questions are about the people and the chain. Samples collected by a food inspection officer go to the food analyst for testing, and the public food analyst must hold at least a master’s degree in food science, food technology or chemistry with at least five years of experience in food research or analysis. On receiving a sample the analyst first checks that the seal and packaging are intact and suitable for testing, keeps an updated register of samples, and reports on them to the Department or office every month.

A representative sample speaks for the whole lot

The heart of sampling is representativeness: a sample counts only if it reflects the average quality of the whole lot or batch. That is why a heterogeneous lot such as grain in several sacks is sampled by increments from different points, combined into one composite, and why a liquid in a large tank is sampled after mixing, from a point that represents the bulk. Microbiological samples need sterile equipment and sterile containers, chilled transport without delay, and sealing, labelling and identification at the moment of collection, so the chain of custody holds until analysis. The set closes with the ICMSF three-class plan, where n counts the sample units, c caps the marginal units, m and M set the limits, and M is the ceiling no unit may exceed.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. The sampling questions reward method over memory, so after each wrong answer ask yourself what would go wrong with the sample if you did it the other way.

Food Technology Loksewa – Food Sampling
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: Food sampling, how a small sample speaks for the whole lot

Food sampling takes a small part of a lot so lab tests speak for the whole lot. A sample is representative when it mirrors the average quality of the full lot. For grain in several sacks, take small portions from several spots and mix them. Tank liquids are sampled after mixing, from a spot that stands for the bulk. Tools and containers must be spotless and dry, since leftovers would spoil the result. Each sample is sealed, marked and named when taken, so its identity stays safe. Germ testing needs sterile tools and pots, kept cold and sent to the lab at once.

Under the 2081 Act, samples go to the food analyst. The public analyst needs a master's degree and five years of food research or analysis work. The analyst checks seal and packing on arrival, keeps a register of samples, and reports to the Department each month. Test reports for samples seized under a sale-ban order must come within 15 days. Schedule 3 sets the amount: foods not listed need about 250 grams or 250 millilitres, plus 500 grams for pesticide, mycotoxin or radiation testing.

In the ICMSF plan, c is the most units allowed between m and M, and M is a ceiling no unit may cross. Remember: sample the lot as it is, not as it is easiest to reach.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: Under Schedule-3 note (2), when a sample is taken for pesticide, mycotoxin or radiation testing, the stated quantity must be increased by :

  • A. 1000 grams
  • B. 250 grams
  • C. 100 grams
  • D. 500 grams

Correct answer: 500 grams

Schedule-3's note (2) adds a testing surcharge: when a sample is taken for pesticide, mycotoxin, or radiation analysis, the stated quantity must be increased by 500 grams. Those analyses need extra material for multiple residue scans and confirmatory re-testing, which the base quantity alone can't cover.

Question 2: Under Schedule-3 note (1), the sample quantity for foods NOT listed in the schedule is about :

  • A. 100 grams
  • B. 50 grams
  • C. 250 grams or 250 millilitres
  • D. 1 kilogram

Correct answer: 250 grams or 250 millilitres

For foods the schedule doesn't list, note (1) of Schedule-3 sets a practical default: about 250 grams or 250 millilitres. That's enough material for the laboratory to run its analyses with a margin for repeats, without demanding a full kilogram of every unlisted product.

Question 3: The test report of a food sample seized under a sale-ban order must be obtained within:

  • A. 7 days
  • B. 15 days
  • C. 30 days
  • D. 90 days

Correct answer: 15 days

A sale-ban sample can't wait in a queue: the testing must be done so the report is received as soon as possible and within fifteen days, matching the deadline in Section 33(3) of the 2081 Act. The business's goods stay restricted only until the science answers.

Question 4: Under the 2081 Act, samples collected by a food inspection officer are sent for testing and analysis to the -

  • A. Ward office
  • B. Food analyst (खाद्य विश्लेषक)
  • C. Police laboratory
  • D. Customs laboratory

Correct answer: Food analyst (खाद्य विश्लेषक)

Collected samples go to the food analyst (खाद्य विश्लेषक) for testing and analysis : Section 29(1)(c) of the 2081 Act sends samples drawn during monitoring straight to the analyst. Ward, police, and customs offices aren't testing laboratories.

Question 5: A public food analyst (सार्वजनिक खाद्य विश्लेषक) under the 2081 Act must hold at least a master's degree in food science, food technology or chemistry and have -

  • A. At least five years' experience in food research or analysis
  • B. A medical degree
  • C. No experience requirement
  • D. A law degree

Correct answer: At least five years' experience in food research or analysis

Section 39(1) of the 2081 Act sets a high bar for the public food analyst: at least a master's degree in food science, food technology, or chemistry, plus at least five years of experience in food research or analysis. Test results can send a business to court, so the Act demands both credentials and a track record.

Question 6: On receiving a sample, the public food analyst must first verify that -

  • A. The fee is paid
  • B. The seal and packaging are intact and suitable for testing
  • C. The owner is present
  • D. The sample is tasty

Correct answer: The seal and packaging are intact and suitable for testing

Before testing, Section 39(3)(b) requires the public food analyst to confirm the sample's seal and packaging are intact and suitable for testing : and to alert the concerned authority if the seal is broken or the package is damaged. An opened or tampered sample can't give a trustworthy result.

Question 7: The public food analyst must keep an updated register of samples and send a report on them to the Department or office -

  • A. Only on request
  • B. Monthly
  • C. Yearly
  • D. Daily

Correct answer: Monthly

Section 39(3)(c) keeps samples traceable at the laboratory: the analyst maintains an updated register of samples received and reports on them to the Department or office every month. Monthly reporting is frequent enough to catch backlogs or irregularities early.

Question 8: Under the 2081 Act, a food sample suspected to be substandard, unsafe or contaminated is collected -

  • A. In any convenient manner
  • B. Only at night
  • C. Only from factories
  • D. In the manner prescribed (तोकिए बमोजिम)

Correct answer: In the manner prescribed (तोकिए बमोजिम)

Section 32(1) of the 2081 Act says a suspected food's sample is collected 'in the manner prescribed' (तोकिए बमोजिम) : following the formal sampling procedure, not whatever is convenient. Prescribed methods are what make the sample legally defensible later.

Question 9: A food sample is considered 'representative' when it -

  • A. Reflects the average quality of the whole lot or batch
  • B. Is taken from the top of the container only
  • C. Is the cheapest unit
  • D. Is the largest unit available

Correct answer: Reflects the average quality of the whole lot or batch

A representative sample reflects the average quality of the whole lot or batch : that's the entire point of sampling. Taking only from the top, or picking the cheapest or largest unit, biases the result toward one corner of the lot.

Question 10: When sampling a heterogeneous lot, such as grain stored in several sacks, the correct practice is to -

  • A. Take increments from different points in the lot and combine them
  • B. Sample only the first sack
  • C. Take one handful from anywhere
  • D. Ask the owner which sack is best

Correct answer: Take increments from different points in the lot and combine them

With a non-uniform lot like grain in several sacks, correct practice is to take increments from different points across the lot and combine them into a composite sample. One sack : or one handful : can't speak for the rest.

Question 11: Samples collected for microbiological analysis should be taken with sterile equipment into sterile containers because -

  • A. It speeds up the analysis
  • B. Glass is cheaper
  • C. It looks professional
  • D. Any outside contamination would give a false picture of the food's microbes

Correct answer: Any outside contamination would give a false picture of the food's microbes

Microbiological samples must go into sterile containers using sterile equipment because any outside microbes would contaminate the sample and paint a false picture of the food's own microbial load. The analysis can only be trusted if nothing was added during collection.

Question 12: Samples collected for microbiological testing should be -

  • A. Frozen solid for a week first
  • B. Kept chilled and transported to the laboratory without delay
  • C. Kept at room temperature for a day
  • D. Mixed with preservatives always

Correct answer: Kept chilled and transported to the laboratory without delay

Microbes don't wait: samples for microbiological testing must be kept chilled and reach the laboratory without delay. Freezing solid for a week, leaving them a day at room temperature, or adding preservatives would all change the microbial counts before analysis.

Question 13: Each collected food sample must be sealed, labelled and identified at the time of collection so that -

  • A. It looks official
  • B. Its identity and integrity are preserved until analysis (chain of custody)
  • C. It can be sold later
  • D. The owner can open it

Correct answer: Its identity and integrity are preserved until analysis (chain of custody)

Sealing, labelling, and identifying each sample at the moment of collection preserves its identity and integrity all the way to analysis : the chain of custody. Without it, there's no proof the tested sample is the one that was collected.

Question 14: In the ICMSF three-class sampling plan denoted by n, c, m and M, the symbol 'c' stands for -

  • A. The minimum count allowed
  • B. The number of sample units
  • C. The mass of the sample
  • D. The maximum allowable number of sample units with counts between m and M

Correct answer: The maximum allowable number of sample units with counts between m and M

In the ICMSF three-class plan (n = number of sample units, m and M = limits), 'c' is the maximum number of sample units allowed to have counts between m and M. A few marginal units are tolerated; more than c means the lot fails.

Question 15: In the ICMSF three-class sampling plan, 'M' denotes -

  • A. The moisture content
  • B. A microbiological limit that must not be exceeded in any sample unit
  • C. The mass in grams
  • D. The average count

Correct answer: A microbiological limit that must not be exceeded in any sample unit

'M' is the hard ceiling in the three-class plan: a microbiological limit that no single sample unit may exceed. Any unit at or above M fails the lot outright, regardless of how the other units look.

Question 16: When sampling prepackaged foods for analysis, the correct practice is to -

  • A. Taste each pack first
  • B. Take intact, unopened retail units
  • C. Open all packs and mix the contents
  • D. Take only damaged packs

Correct answer: Take intact, unopened retail units

For prepackaged foods, sampling means taking intact, unopened retail units. Opening packs and mixing contents destroys the package-product relationship the laboratory needs to assess, and tasting is obviously out of the question.

Question 17: Sampling equipment and containers must be clean and dry before use because -

  • A. It is a legal fashion
  • B. Residues could contaminate the sample and distort results
  • C. Clean tools work faster
  • D. Dirty equipment is heavier

Correct answer: Residues could contaminate the sample and distort results

Sampling tools and containers must be clean and dry because residues from previous use could contaminate the sample and distort the results : a dirty scoop can turn a passing product into a failing one, or mask a real problem.

Question 18: On receiving a sample, the laboratory should check and record -

  • A. Only the weight
  • B. The market price
  • C. The owner's name only
  • D. The seal condition, storage temperature and accompanying documents

Correct answer: The seal condition, storage temperature and accompanying documents

On receiving a sample, the laboratory checks and records the seal condition, the storage temperature, and the accompanying documents. Those three tell the lab whether the sample arrived intact, was kept properly, and is who it claims to be.

Question 19: A retention (reference) sample is kept after analysis so that -

  • A. It can be sold
  • B. It can be eaten later
  • C. It decorates the laboratory
  • D. It is available for re-testing in case of dispute

Correct answer: It is available for re-testing in case of dispute

A retention (reference) sample is held back after analysis so it can be re-tested if the result is disputed. It's the laboratory's insurance policy : the material evidence that settles arguments about what was actually tested.

Question 20: For chemical analysis of a liquid food stored in a large tank, the sample should be taken -

  • A. Only from the bottom valve
  • B. After mixing, from a point representing the bulk
  • C. Without touching the tank
  • D. Only from the surface

Correct answer: After mixing, from a point representing the bulk

Liquids stratify in a large tank, so the sample must be taken after mixing, from a point that represents the bulk. Sampling only the surface or only the bottom valve would capture one layer, not the whole tank.