Food Engineering Part 15 Quiz
GIFSQ ID: ART-1092
Test your knowledge with this free 20-question Food Engineering quiz (Part 15). Choose the correct answer for each…
What this quiz covers
This quiz covers evaporators and psychrometrics, the two tools that set how water is removed and how air behaves around food. It opens with steam economy: a single-effect evaporator needs about 1.2 lb of steam per pound of water boiled off, a triple-effect unit only about 0.4 lb, and a double-effect unit with a thermocompressor splits the boiling two-thirds in the first effect and one-third in the second. Each effect in a multiple-effect evaporator runs at its own temperature, set by the vacuum in its chamber, and steam used per unit of vapour driven off is called the specific steam consumption.
The second half is the psychrometric chart and the instruments that feed it. Drier air means a bigger wet-bulb depression, cooling air at fixed moisture leaves specific humidity constant, and absolute humidity over saturation absolute humidity is the degree of saturation. The sling psychrometer is two thermometers, one with a wet-cloth bulb, and the chart itself plots the thermodynamic properties of moist air. Sensible heating traces a horizontal line, saturated air has equal dry-bulb and wet-bulb temperatures with zero wet-bulb depression, and equilibrium moisture against relative humidity gives the familiar sigmoid curve.
Dry-bulb, wet-bulb and dew point: three temperatures, one chart
Five questions in this set turn on the gap between dry-bulb and wet-bulb temperature, and they all follow one rule: the gap exists because evaporation cools the wet bulb, so it shrinks as the air gets wetter and vanishes at saturation. Hold that picture and the wet-bulb questions, the saturation questions and the sensible heating question all answer themselves.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the correct choice in plain words, so a miss becomes a fact you keep. Sketch a psychrometric chart from memory as you read the second half: placing each question on the chart is the fastest way to make the terms stick.
Choose how you want to play
A short note: evaporators and psychrometrics
A single-effect evaporator uses roughly 1.2 lb of steam per lb of water from milk. A triple-effect evaporator needs only about 0.4 lb. Each effect boils at the saturation temperature set by its vacuum. In a double-effect evaporator with a thermocompressor, the first effect boils off two-thirds of the water and the second one-third. Specific steam consumption is steam used per unit of water vapour driven off.
Air at 40 degrees C and 50 percent humidity has a wet-bulb depression of 10 degrees C, which grows larger if humidity falls to 40 percent. For moist air, the dry-bulb reading sits above the wet-bulb reading. When air is saturated, dry-bulb and wet-bulb temperatures are equal. Specific humidity is the humidity ratio. Degree of saturation is absolute humidity over saturation absolute humidity. Cooling air without changing its moisture leaves specific humidity constant.
A sling psychrometer carries two thermometers, one with a wet bulb. A psychrometric chart plots the properties of moist air. Sensible heating or cooling traces a horizontal line on the chart. Equilibrium moisture content is measured by the static method or the dynamic method. An EMC versus relative humidity plot gives a sigmoid curve. Henderson, GAB and BET are sorption models; Raoult's model is not.
Read the psychrometric chart before you size the dryer: it holds every property of the air you need.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: Roughly how much steam does a single-effect evaporator need to boil off 1 lb of water from milk?
Correct answer: 1.2 lb
A single-effect evaporator needs roughly 1.1-1.3 kg of steam per kg of water evaporated - each kilogram of condensing steam supplies about one kilogram of evaporation, minus boiling-point-elevation and heat losses. That figure is the specific steam consumption (Food Processing Handbook: Evaporation and Dehydration).
Question 2: Roughly how much steam does a triple-effect evaporator need to boil off 1 lb of water?
Correct answer: 0.4 lb
Each added effect reuses the previous effect's vapor as heating steam, so steam demand falls roughly as 1/n: a triple-effect unit needs about 0.33-0.4 lb of steam per lb of water (Geankoplis: ~3 kg water evaporated per kg steam in a three-effect forward-feed unit).
Question 3: How does a multiple-effect evaporator differ from a single-effect one?
Correct answer: Both (a) and (b)
Each effect boils at the saturation temperature fixed by the vacuum held in its chamber, so effects run at progressively lower temperatures from first to last - both statements describe the same multiple-effect design.
Question 4: In a double-effect evaporator fitted with a thermocompressor, what share of the total water is boiled off in the first and second effects respectively?
Correct answer: Two-thirds and one-third
A thermocompressor recycles part of the second effect's vapor back to heat the first effect, so the first effect boils off the larger share - conventionally about two-thirds in the first effect and one-third in the second.
Question 5: The mass of steam used per unit mass of water vapour driven off in an evaporator is called the
Correct answer: specific steam consumption
Specific steam consumption is the textbook term for the mass of steam used per unit mass of water evaporated (its inverse is the steam economy).
Question 6: Air at 40°C and 50% relative humidity shows a wet-bulb depression of 10°C. If the relative humidity falls to 40%, the wet-bulb depression will
Correct answer: grow larger
Drier air has a bigger gap between the dry-bulb and wet-bulb readings, so when relative humidity falls at fixed dry-bulb temperature, the wet-bulb depression grows larger.
Question 7: The vapour pressure exerted by the moisture inside a wet solid depends on
Correct answer: All of these
The vapor pressure of water in a wet solid depends on how the water is held (free vs bound), on the temperature, and on the solid's own nature - all three.
Question 8: A mixture of air and water vapour is cooled without changing its moisture content. Its specific humidity
Correct answer: stays constant
Cooling air without adding or removing moisture leaves its moisture content unchanged: specific humidity (the humidity ratio) stays constant while relative humidity climbs.
Question 9: Absolute humidity divided by the saturation absolute humidity at the gas temperature is called the
Correct answer: degree of saturation
Degree of saturation is defined as actual absolute humidity divided by the saturation absolute humidity at the gas temperature (percentage humidity is 100 times this).
Question 10: A sling psychrometer consists of
Correct answer: two thermometers, one with a wet-cloth-covered bulb
A sling (whirling) psychrometer carries two thermometers - one dry bulb and one wet bulb with its bulb wrapped in a wet wick - whirled through the air to get the evaporative-cooling reading.
Question 11: A psychrometric chart is a graphical plot of
Correct answer: the thermodynamic properties of moist air
A psychrometric chart plots the thermodynamic properties of moist air: dry-bulb temperature, wet-bulb temperature, humidity ratio, enthalpy, specific volume and relative humidity.
Question 12: When the gas is saturated, the humid volume is known as the
Correct answer: saturated volume
At saturation the humid volume - volume per unit mass of dry air plus its vapor - is the saturated (saturation) volume by definition.
Question 13: Specific humidity is another name for the
Correct answer: humidity ratio
Specific humidity is the humidity ratio: mass of water vapor per mass of dry air.
Question 14: For moist (unsaturated) air, the dry-bulb temperature is ____ the wet-bulb temperature.
Correct answer: higher than
Whenever air is unsaturated, evaporation cools the wet bulb below the dry-bulb reading - so the dry-bulb temperature is higher.
Question 15: On a psychrometric chart, sensible heating or cooling of an air, vapour mixture traces
Correct answer: a horizontal line
Sensible heating or cooling changes temperature at constant moisture content, which traces a horizontal line (constant humidity ratio) on the psychrometric chart.
Question 16: When air is fully saturated, its dry-bulb and wet-bulb temperatures are related by
Correct answer: T_db = T_wb
At full saturation no net evaporation occurs at the wet wick, so the wet-bulb and dry-bulb readings coincide: T_db = T_wb.
Question 17: When air becomes fully saturated, the wet-bulb depression becomes
Correct answer: zero
The wet-bulb depression (T_db - T_wb) measures how far air is from saturation - at saturation it is zero.
Question 18: Equilibrium moisture content can be measured by
Correct answer: Both (a) and (b)
EMC can be measured by the static method (samples equilibrated over saturated salt solutions in desiccators) or the dynamic method (controlled-humidity air passed over the sample) - both are standard practice.
Question 19: Plotting equilibrium moisture content against relative humidity gives
Correct answer: a sigmoid curve
EMC-vs-RH sorption isotherms have the characteristic S-shape (sigmoid): slow uptake at low RH (monolayer region), a steep middle rise (multilayer), and leveling at high RH.
Question 20: Which model is NOT used for describing equilibrium moisture content?
Correct answer: Raoult’s model
Henderson, GAB and BET are all equilibrium-moisture-content sorption models; Raoult's law describes vapor-pressure lowering in ideal solutions, not moisture sorption.