Membrane Processing & Refrigeration Quiz
GIFSQ ID: ART-0955
What this quiz covers
This quiz joins two plant topics: membrane processing and refrigeration. The first half finishes the membrane set with concentration polarization, the limits of membrane plants, evaporators, and the materials, pore sizes, and pressures of ultrafiltration and reverse osmosis. The second half turns to cold: what makes a good refrigerant, the parts of a refrigeration system, the types of condensers, and the faults that stop a compressor.
Twenty questions cover hollow-fibre modules showing low concentration polarization; ultracentrifugation as the method that is not a membrane process; concentration polarization, fouling, and shear damage as the limits of membrane processing; open-pan, plate, rising-film, falling-film, and agitated thin-film evaporators; ultrafiltration for clarification, concentration, and purification, with polysulfone, PVDF, and cellulose acetate membranes, pores of 1 to 100 nm, and 1 to 10 bar; reverse osmosis at 10 to 100 bar, removing about 99 percent of ions and about 99.9 percent of viruses, bacteria, and pyrogens; a refrigerant needing a high critical temperature and nontoxic, nonflammable traits; the boiler as the part missing from a refrigeration system; the compressor as the item that is no condenser type; cooling load in tons of refrigeration; and clean condenser coils as the condition that would not stop a compressor starting, against a faulty relay and weak winding tripping it.
Concepts you will need
Two contrasts carry this set. In membranes, pressure follows pore size: ultrafiltration has wide pores and runs at 1 to 10 bar, while reverse osmosis has tight pores and needs 10 to 100 bar to beat osmotic pressure. In refrigeration, the system is a loop of four parts, compressor, condenser, expansion device, and evaporator, and every fault question is about which part of that loop has failed.
How to use this quiz
You get 20 seconds per question and one attempt at each answer, so sort the question into membranes or refrigeration first, then into its small group: process, material, pressure, or fault. For the NOT questions, name the three that fit and cross them out: the answer is the one left standing. Then retake the quiz and check the sorting holds.
Choose how you want to play
A short note: membrane processing and refrigeration
Membrane processing and refrigeration are two workhorses of food plants: membranes separate without heat, and refrigeration removes heat to keep food cold.
Ultrafiltration uses membranes with pores of about 1 to 100 nm, cast from polysulfone, polyvinylidene fluoride or cellulose acetate, and runs at 1 to 10 bar. It serves clarification, concentration and purification, since it retains proteins, colloids and viruses while water and small solutes pass. Reverse osmosis runs far harder, at 10 to 100 bar, because it must overcome the feed's osmotic pressure, and it removes about 99 percent of ions and about 99.9 percent of viruses, bacteria and pyrogens.
A vapour-compression system has four parts: compressor, condenser, expansion device and evaporator. Boilers are not part of it. A good refrigerant has a high critical temperature so it can condense at the temperatures the condenser can reach, and it should be nontoxic and nonflammable, since leaks must neither poison nor ignite. Cooling load is measured in tons of refrigeration: one ton is the heat taken in to melt one ton of ice over 24 hours, about 3.517 kW.
Blown fuses, a broken connection or a dead starting relay can all stop a compressor starting; clean condenser coils are the normal healthy state. A compressor that trips repeatedly and then lurches on restart points to a defective starting relay, a weak starting winding, or both.
Check the refrigerant safety traits and the compressor electrics first when a cold room warms up.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: Which membrane module shows low concentration polarization?
Correct answer: Hollow-fibre
In the published comparison of pressure-driven membrane module configurations, concentration polarization is rated low for hollow-fibre modules, against high for plate-and-frame and tube-in-shell and medium for spiral-wound (food-technology curriculum comparison table, Table 1). The thousands of narrow fibres give a very large membrane area per module volume, so the flux per unit area : and the solute build-up at the wall : stays low. That low polarization comes at the price of fragile fibres and limited cleanability.
Question 2: Which of these is NOT a membrane process?
Correct answer: Ultracentrifugation
Ultrafiltration, reverse osmosis and electrodialysis all separate species across a semipermeable membrane. Ultracentrifugation separates by sedimentation under centrifugal force, with no membrane involved, so it is not a membrane process.
Question 3: Membrane processing has which limitations?
Correct answer: All of these
Membrane plants are limited by concentration polarization (solute accumulating at the membrane wall and cutting flux), fouling (pore blockage and cake build-up), and shear damage : high cross-flow velocities and pumps can rupture shear-sensitive cells and denature proteins. Each limitation forces trade-offs in operating conditions and module choice.
Question 4: Which of these evaporators can be used for evaporative concentration?
Correct answer: All of these
Open-pan, plate and rising-film evaporators are all used for evaporative concentration in food processing. The choice depends on heat sensitivity, viscosity and residence-time needs : rising-film and plate types suit heat-sensitive juices, while open pans handle simpler duties.
Question 5: Which other evaporators can be used for evaporative concentration?
Correct answer: Both of these
Falling-film evaporators spread a thin liquid film down heated tubes for short, gentle heating, and agitated thin-film evaporators add mechanical wiping for viscous feeds. Both are standard equipment for evaporative concentration of foods.
Question 6: What is ultrafiltration used for?
Correct answer: All of these
Ultrafiltration membranes retain macromolecules while letting water and small solutes pass, so the same principle serves clarification (removing suspended solids), concentration (retaining proteins or colloids) and purification (washing out small contaminants). Whey protein concentration and juice clarification are classic food uses.
Question 7: What materials make up ultrafiltration membranes?
Correct answer: All of these
Ultrafiltration membranes are cast from polymers including polysulfone, polyvinylidene fluoride (PVDF) and cellulose acetate. The polymer choice sets chemical resistance, hydrophilicity and cleanability for the food duty.
Question 8: What is the pore-size range of ultrafiltration membranes?
Correct answer: 1, 100 nm
Ultrafiltration sits between microfiltration and nanofiltration, with pores roughly 1, 100 nm (about 1, 1000 kDa molecular-weight cut-off). That is why UF retains proteins, colloids and viruses while passing salts and sugars.
Question 9: What pressure range is applied in ultrafiltration?
Correct answer: 1, 10 bar
Ultrafiltration is a low-pressure, pressure-driven process, normally run at 1, 10 bar. The modest pressure reflects the large pore size : far less driving force is needed than for reverse osmosis.
Question 10: What excess pressure range is applied in reverse osmosis?
Correct answer: 10, 100 bar
Reverse osmosis must overcome the feed's osmotic pressure, so it runs at 10, 100 bar : roughly an order of magnitude above ultrafiltration. Seawater desalination sits at the high end of that range.
Question 11: About what percentage of ions does reverse osmosis remove?
Correct answer: 99%
Reverse-osmosis membranes reject about 99% of dissolved ions : monovalent ions such as sodium slightly less, multivalent ions more. That rejection level is what makes RO the workhorse for desalination and boiler-feed water.
Question 12: About what percentage of viruses and bacteria does reverse osmosis remove?
Correct answer: 99.9%
RO membranes are effectively a molecular barrier: they remove about 99.9% of viruses and bacteria, the standard log-reduction basis for claiming RO-treated water is microbiologically safe.
Question 13: About what percentage of pyrogens does reverse osmosis remove?
Correct answer: 99.9%
Pyrogens : bacterial endotoxins that cause fever : are large lipopolysaccharide fragments, so reverse osmosis removes about 99.9% of them. RO is therefore a standard step in producing water for injection and other pyrogen-free waters.
Question 14: The critical temperature of a refrigerant should ideally be what?
Correct answer: High
A refrigerant must condense at the temperatures the condenser can actually reach, which is only possible when the condenser operates below the fluid's critical temperature. A high critical temperature keeps the vapour-compression cycle safely subcritical under normal ambient conditions.
Question 15: Which safety traits should a good refrigerant have?
Correct answer: Both
A good refrigerant is both nontoxic and nonflammable, because leaks into occupied spaces must neither poison nor ignite. Toxicity and flammability are core safety criteria in refrigerant selection (the basis of the ASHRAE Standard 34 safety classification).
Question 16: Which of these is NOT part of a refrigeration system?
Correct answer: Boiler
A vapour-compression refrigeration system is built from a compressor, condenser, expansion device and evaporator. A boiler belongs to heating or power-steam systems, not to the refrigeration circuit.
Question 17: Which of these is NOT a recognized type of condenser?
Correct answer: Compressor
Condensers are classified by how they reject heat: air-cooled, water-cooled and evaporative. A compressor is the component that raises the refrigerant pressure : it is part of the system, not a condenser type.
Question 18: Cooling load is generally expressed in which unit?
Correct answer: Ton of refrigeration
Cooling load is expressed in tons of refrigeration : one ton equals the heat absorbed in melting one ton of ice in 24 hours (about 3.517 kW). It is the industry's standard capacity unit.
Question 19: A fridge compressor refuses to start. Which of these would NOT stop it from starting?
Correct answer: Clean condenser coils
Blown fuses, a broken electrical connection or a dead starting relay all prevent current from reaching the compressor, so it cannot start. Clean condenser coils are the normal, healthy condition : they do not stop the motor; dirty coils cause overheating and tripping instead.
Question 20: A compressor trips repeatedly, then lurches when it restarts. Which faults explain that?
Correct answer: Both
A defective starting relay can chatter and trip the overload, and a weak starting winding cannot develop the torque to come up to speed, so the motor stalls, draws locked-rotor current and trips again. Either fault produces the trip-and-lurch pattern.