What this quiz covers

Membrane processing separates without heat, and this quiz tests the processes, the principles, and the module numbers. You will meet reverse osmosis, ultrafiltration, electrodialysis, and pervaporation, the semi-permeable membrane that passes solvent and holds back solute, and the four module configurations compared on packing density, permeate flux, and flux density.

Twenty questions cover reverse osmosis concentrating fruit juices and desalinating seawater; ultrafiltration as the membrane process that separates particles from a fluid; distillation as the method that is not a membrane process; the semi-permeable membrane passing solvent molecules; absorption as the method that cannot separate a liquid solution; pervaporation for separating and concentrating liquid mixtures; filtration removing pulp from orange juice; packing densities of 200 to 400 for plate-and-frame, 300 to 900 for spiral-wound, 150 to 300 for tube-in-shell, and 9000 to 30000 for hollow-fibre modules; permeate flux of 0.3 to 1.0 for the first three and 0.004 to 0.08 for hollow-fibre; and flux densities of 60 to 400, 90 to 900, 45 to 300, and 36 to 2400 in the same order.

Concepts you will need

Hold two ideas together. First, the membrane is the test: if the separation uses a membrane as the barrier, it belongs in the set, and distillation and absorption do not. Second, the module numbers are arithmetic, not separate facts: flux density is permeate flux times packing density, so hollow-fibre wins on volume despite the lowest flux per area, because its packing density is far above the rest.

How to use this quiz

You get 20 seconds per question and one attempt at each answer, so ask whether a membrane does the work before you pick a process name. For the module numbers, learn the ranking first: hollow-fibre packs the most area by far, tube-in-shell the least, and the flux densities follow that order. If a number looks familiar, check which module it belongs to before you answer. Then retake the quiz and check the rankings hold.

Membrane Processing Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

Answer explanations

Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.

  1. What is reverse osmosis, a membrane technology, used for?
    Correct answer: Producing some fruit juices. Reverse osmosis concentrates fruit juices by forcing water through the membrane while holding back sugars and flavour compounds. It runs cool, so heat-sensitive aromas survive better than in evaporation. Juice concentration is its classic food use.
  2. Which of these is a process of filtration in which solid particles are separated from a fluid by passing through a porous membrane?
    Correct answer: Ultrafiltration. Ultrafiltration is the membrane process that separates particles, macromolecules and colloids, from a fluid through a porous membrane. Reverse osmosis rejects dissolved salts rather than particles, and centrifugal filtration is not a membrane process.
  3. Which of these is not a membrane separation process?
    Correct answer: Distillation. Distillation is not a membrane separation process: it separates by boiling-point differences using heat. Reverse osmosis, electrodialysis, and ultrafiltration all use a membrane as the separating barrier. The membrane is the test.
  4. A semi-permeable membrane lets which molecules pass through?
    Correct answer: Solvent molecules. A semi-permeable membrane passes solvent molecules while holding back solute. That selective passage is what builds osmotic pressure in the first place. If both or neither passed, there would be no separation at all.
  5. Which separation technique is used to desalinate seawater?
    Correct answer: Reverse osmosis. Reverse osmosis desalinates seawater by pushing water through a membrane that rejects dissolved salts. The applied pressure has to overcome seawater's osmotic pressure, roughly 2.5 MPa. RO is the standard membrane route to fresh water.
  6. Separation of two or more components of a liquid solution CANNOT be achieved by which method?
    Correct answer: Absorption. Absorption cannot separate the components of a liquid solution: it transfers a solute from a gas stream into a liquid. Liquid extraction, fractional crystallization, and evaporation all act directly on liquid mixtures.
  7. The pervaporation method is used for which purpose?
    Correct answer: Separating and concentrating liquid mixtures. Pervaporation separates and concentrates liquid mixtures, typically by selectively permeating one component through a dense membrane under vacuum. It shines on azeotropes that distillation cannot split. Mixture separation is its job.
  8. How do manufacturers remove pulp from orange juice?
    Correct answer: Filtration. Filtration removes pulp from orange juice: the pulp stays on the screen while the juice passes through. Evaporation and sublimation remove water, not pulp. Physical separation on a barrier is what the question describes.
  9. What is the packing density (m²/m³) of a plate-and-frame membrane module?
    Correct answer: 200-400. Plate-and-frame modules pack 200 to 400 square metres of membrane per cubic metre. Flat sheets stacked with spacers give modest area density but easy access for cleaning. That range is the textbook comparison figure for this configuration.
  10. What is the packing density (m²/m³) of a spiral-wound membrane module?
    Correct answer: 300-900. Spiral-wound modules pack 300 to 900 square metres per cubic metre, more than plate-and-frame, because the wound envelope crams more sheet into the housing. The spacer-filled channels keep that area accessible. The 300 to 900 range is the standard comparison figure.
  11. What is the packing density (m²/m³) of a tube-in-shell membrane module?
    Correct answer: 150-300. Tube-in-shell modules sit at 150 to 300 square metres per cubic metre, the lowest of the common configurations. Fat tubes mean little surface per volume, traded for fouling resistance. Low packing density is the price of those wide, cleanable channels.
  12. What is the packing density (m²/m³) of a hollow-fibre membrane module?
    Correct answer: 9000-30000. Hollow-fibre modules reach 9000 to 30000 square metres per cubic metre, an order of magnitude above the rest. Thousands of fine fibres bundle into each housing, multiplying surface area. No other configuration packs membrane this densely.
  13. What is the typical permeate flux (m³/[m²·day]) of a plate-and-frame module?
    Correct answer: 0.3-1.0. Plate-and-frame modules typically pass 0.3 to 1.0 cubic metres of permeate per square metre of membrane per day. Multiply by the 200 to 400 packing density and you get the 60 to 400 flux density from the next question. The two figures are linked by arithmetic.
  14. What is the typical permeate flux (m³/[m²·day]) of a spiral-wound module?
    Correct answer: 0.3-1.0. Spiral-wound modules share the 0.3 to 1.0 cubic metres per square metre per day permeate-flux range. Same membrane materials and similar driving pressures: the configuration changes packing, not flux per unit area. That is why the flux matches plate-and-frame.
  15. What is the typical permeate flux (m³/[m²·day]) of a tube-in-shell module?
    Correct answer: 0.3-1.0. Tube-in-shell modules also run 0.3 to 1.0 cubic metres per square metre per day of permeate flux. Flux per unit membrane area is set by the membrane and the process, not the housing geometry. The identical range across three configurations reflects exactly that.
  16. What is the typical permeate flux (m³/[m²·day]) of a hollow-fibre module?
    Correct answer: 0.004-0.08. Hollow-fibre modules run far lower permeate flux per area, 0.004 to 0.08 cubic metres per square metre per day. The fine fibres and thick walls raise resistance, but the enormous packing density more than compensates in volumetric terms. Low flux per area, huge flux per volume.
  17. What is the flux density (m³/[m³·day]) of a plate-and-frame module?
    Correct answer: 60-400. Plate-and-frame flux density is 60 to 400 cubic metres per cubic metre per day: permeate flux, 0.3 to 1.0, times packing density, 200 to 400. The low end pairs 0.3 with 200 and the high end 1.0 with 400. It is arithmetic, not a separate measurement.
  18. What is the flux density (m³/[m³·day]) of a spiral-wound module?
    Correct answer: 90-900. Spiral-wound flux density runs 90 to 900 cubic metres per cubic metre per day: the same 0.3 to 1.0 flux times the tighter 300 to 900 packing. Better packing lifts volumetric productivity well above plate-and-frame. Configuration, not membrane, drives the difference.
  19. What is the flux density (m³/[m³·day]) of a tube-in-shell module?
    Correct answer: 45-300. Tube-in-shell flux density is 45 to 300 cubic metres per cubic metre per day, the lowest of the four, from 0.3 to 1.0 flux times 150 to 300 packing. Wide tubes sacrifice volumetric productivity for cleanability. The math is the same multiplication.
  20. What is the flux density (m³/[m³·day]) of a hollow-fibre module?
    Correct answer: 36-2400. Hollow-fibre flux density tops the table at 36 to 2400 cubic metres per cubic metre per day: 0.004 to 0.08 flux times 9000 to 30000 packing. The extreme packing density overwhelms the low per-area flux. Volumetrically, nothing else comes close.