Analytical Techniques Quiz
GIFSQ ID: ART-0559
Questions on the lab techniques used to analyse food: what each one measures and when you'd reach…
Analysis turns a sample into an answer
Analytical techniques are how a food laboratory turns a jar of something into a number it can trust. This set covers the core bench: oven drying for moisture, ether extraction for fat, SDS-PAGE for protein size, agarose gels for DNA fragments, ultrafiltration for enzyme purification, HPLC columns, UV-visible spectrophotometry under the Beer-Lambert law, and ion exchange resins built from cross-linked polyelectrolytes. Each method answers a different question, and choosing well starts with naming the question correctly. Sample preparation decides most results before any instrument runs, since a badly ground, badly extracted or badly diluted sample will mislead even a perfect chromatograph.
Classic tests still anchor the lab
New instruments have not retired the classics. Kjeldahl still estimates crude protein, Benedict’s still spots reducing sugars, Seliwanoff’s resorcinol still picks out ketoses, ninhydrin still reveals amino groups, and the phosphatase test still catches milk that missed proper pasteurisation. Even a pH meter keeps its two-electrode design, glass plus reference, because that pairing measures hydrogen ion activity reliably. Questions here reward knowing which classic test fits which analyte, not just which instrument looks modern.
How to use this set
For each question, name the analyte first, protein, sugar, fat, microbe, acid, then pick the method built for it. Notes below name the marked answer for every question and explain the method behind it.
No single analytical technique answers every food question, which is why labs keep a toolkit rather than a favourite instrument. Spectroscopy identifies and quantifies, chromatography separates complex mixtures, microscopy reveals structure, and classical wet chemistry still settles disputes with direct measurements. A good analyst starts from the question: what must be known, at what level, in which matrix. This set rewards that habit of matching method to problem before reaching for an instrument.
Method choice also weighs turnaround: a slower, exact method loses to a faster screening method when a production line waits on the answer.
Choose how you want to play
A short note: analytical techniques
Analytical techniques in food analysis are the laboratory methods that measure what a food contains and how it behaves. Moisture is measured by oven drying, where loss of weight represents loss of water. Fat is extracted with ether, a non-polar solvent that dissolves lipids. Crude protein is estimated by the Kjeldahl method, which measures total nitrogen and converts it with a factor, usually 6.25.
Separation techniques sort molecules by size, charge or polarity. SDS-PAGE separates proteins by size, and agarose gel electrophoresis separates DNA fragments. In chromatography the column is the heart of an HPLC system, where separation happens. Gas-liquid chromatography suits volatile compounds that can vaporize, while normal-phase chromatography suits polar, water-loving substances such as amino acids. Ion-exchange chromatography separates on charge, using synthetic resins made of cross-linked polyelectrolytes, and ultrafiltration purifies enzymes through membranes.
Light-based measurement follows the Beer-Lambert law: a UV-visible spectrophotometer measures absorbance, and transmittance is the ratio of transmitted to incident light. Colour tests still matter: ninhydrin detects amino acids and proteins, Benedict's test identifies reducing sugars, and Seliwanoff's test with resorcinol detects ketose sugars. The phosphatase test reveals inadequate pasteurization of milk, since alkaline phosphatase survives only if heating was insufficient. A pH meter works with two electrodes, glass and reference, and the Bactomatic system tracks bacterial activity by impedance.
Practical takeaway: choose the separation by the molecule, size for proteins, charge for ions, volatility for GC, and polarity for normal phase.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: What is the principle behind oven drying for determination of moisture content of foods?
Correct answer: Loss of weight represents loss of water
Oven drying works on loss of weight: the sample is weighed, heated to drive off water, and weighed again : the difference is the moisture. Colour, refractive index and absorbance are not measured in the oven method.
Question 2: Which of these chemicals is used as a solvent for extraction of fat from food samples?
Correct answer: Ether
Fat is extracted from food samples with ether : the non-polar solvent that dissolves lipids. Hydrochloric acid, sodium hydroxide and amylase are not fat-extraction solvents.
Question 3: Which technique is routinely used to separate proteins by their size?
Correct answer: SDS-PAGE
Proteins are routinely separated by size with SDS-PAGE : the detergent unfolds them and the gel sieves them by molecular weight. HPLC, GLC and agarose gels are not the routine size-separation method for proteins.
Question 4: DNA fragments are most commonly separated in the laboratory by which technique?
Correct answer: Agarose gel electrophoresis
DNA fragments are most commonly separated by agarose gel electrophoresis : the gel matrix sorts them by length under an electric field. SDS-PAGE is the protein equivalent.
Question 5: Which of these is a genuine method for purifying enzymes?
Correct answer: Ultrafiltration
Ultrafiltration is a genuine enzyme-purification method : membranes concentrate and fractionate proteins by size. Gas-liquid and paper chromatography are not enzyme-purification workhorses.
Question 6: Which part of an HPLC system is often called its heart?
Correct answer: Column
The column is often called the heart of an HPLC system : it is where the separation actually happens. The oven, detector and reservoir support it but do not separate.
Question 7: The working of a UV-visible spectrophotometer is based on which law?
Correct answer: Beer-Lambert law
A UV-visible spectrophotometer works on the Beer-Lambert law : absorbance proportional to concentration and path length. Einstein's, Newton's and Edison's laws belong to other physics.
Question 8: The synthetic resins used as ion exchangers in chromatography are made of what?
Correct answer: Cross-linked polyelectrolytes
Synthetic ion-exchange resins are made of cross-linked polyelectrolytes : the cross-linking gives the insoluble bead structure and the polyelectrolyte carries the exchange groups. Parallel-linked electrolytes are not the resin chemistry.
Question 9: Gas-liquid chromatography is used chiefly for the analysis of which kind of compounds?
Correct answer: Volatile
Gas-liquid chromatography is used chiefly for volatile compounds : analytes must vaporize to travel in the carrier gas. Non-volatile compounds need liquid chromatography instead.
Question 10: Polar, water-loving substances such as amino acids and soluble plant pigments are best separated by which mode?
Correct answer: Normal-phase chromatography
Polar, water-loving substances like amino acids and soluble plant pigments are best separated by normal-phase chromatography : the polar stationary phase retains them. Reversed-phase would let them wash straight through.
Question 11: Ion-exchange chromatography is NOT used for separating substances on the basis of what?
Correct answer: Differences in partition coefficient
Ion-exchange chromatography separates on differences in charge : differences in partition coefficient belong to partition chromatography, not ion exchange. Ionic, cationic and charge differences are all its genuine basis.
Question 12: Who first used paper electrophoresis to separate proteins?
Correct answer: Von Klobusitzky and Konig
Von Klobusitzky and Konig first used paper electrophoresis to separate proteins : the pioneering application of the technique to protein mixtures. The other names belong to different contributions.
Question 13: What is the ratio of transmitted light intensity to incident light intensity called?
Correct answer: Transmittance
The ratio of transmitted to incident light intensity is transmittance : the fraction of light that gets through the sample. The extinction coefficients and isoelectric focusing are different quantities.
Question 14: The ninhydrin test is used to detect the presence of what?
Correct answer: Proteins
The ninhydrin test detects proteins : more precisely amino acids and peptides, which turn purple with ninhydrin. Carbohydrates, fats and minerals do not give the reaction.
Question 15: The Kjeldahl method is the classic laboratory procedure for estimating what?
Correct answer: Crude protein
The Kjeldahl method is the classic procedure for estimating crude protein : it measures total nitrogen and converts it to protein. Crude fibre, fat and ash are measured by other methods.
Question 16: Which reagent is used in Seliwanoff's test for ketose sugars?
Correct answer: Resorcinol
Seliwanoff's test for ketose sugars uses resorcinol : the reagent that gives the cherry-red colour with ketoses. Alpha-naphthol is the Molisch reagent; the others are not the Seliwanoff reagent.
Question 17: Reducing sugars are identified in the laboratory by which test?
Correct answer: Benedict's test
Reducing sugars are identified by Benedict's test : the brick-red cuprous oxide precipitate on heating. The biuret and ninhydrin tests detect proteins, not reducing sugars.
Question 18: The Bactomatic method is used to determine bacterial what?
Correct answer: Activity
The Bactomatic system determines bacterial activity : impedance microbiology tracks metabolic activity as microbes grow. It does not measure cell size or decimal reduction values.
Question 19: Which enzyme test reveals inadequate pasteurization of milk?
Correct answer: Phosphatase
The phosphatase test reveals inadequate pasteurization : alkaline phosphatase survives only if the heat treatment fell short. Lipase, catalase and peroxidase are not the pasteurization indicator.
Question 20: A pH meter works with how many electrodes?
Correct answer: Two
A pH meter works with two electrodes : the glass measuring electrode and the reference electrode. A single electrode cannot complete the measuring circuit.