Analytical Techniques β Part 2
GIFSQ ID: ART-0807
What this quiz covers
Food analysis runs on instruments, and this quiz tests the second half of the analytical techniques set: the methods that separate, detect, and measure what is in a food. You will meet blotting, chromatography in several forms, spectroscopy, mass spectrometry, and the wet chemistry that still sits behind the instruments, from chemical oxygen demand to fat extraction with ether.
Twenty questions cover Southern blotting and the diode-array detector; reversed-phase HPLC and the Beer-Lambert law; AAS for lead in drinking water and GC-MS for dioxins; SDS-PAGE and carrier gases; mass-to-charge ratio; slow injection and resolution; ion-exchange resins and gel filtration; affinity chromatography; protein separation by charge, solubility, and size; tracking an energy-metabolism enzyme by its ATP synthesis rate; and ether as the fat-extraction solvent.
Concepts you will need
For each technique, ask three questions: what does it separate, what does it detect, and what does it measure. Chromatography separates, spectroscopy detects, and the two together identify. Once you can name the separation principle for each method, the instrument questions answer themselves.
How to use this quiz
You get 20 seconds per question and one attempt at each answer, so name the technique before you read the options. If a question names a detector or a column, picture the instrument first: the right answer is usually the one that matches how the instrument actually works. Then retake the quiz and check that the picture holds. When a question gives you a number, such as a wavelength range, check the units first: a wrong unit is the fastest way to pick the wrong option, and the right unit usually points straight at the right technique.
Choose how you want to play
Answer explanations
Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.
- The transfer of DNA onto a nitrocellulose membrane is called which kind of blotting?
Correct answer: Southern. Transferring DNA onto a nitrocellulose membrane for probing is Southern blotting, named for Edwin Southern, with Northern for RNA and Western for protein following the same joke. - A diode-array detector (DAD) with UV detection is advantageous because of what?
Correct answer: It covers a range of wavelengths. A diode-array detector captures a whole spectrum of wavelengths at once, so one run gives full UV spectra and peak-purity checks instead of a single-wavelength trace. - In reversed-phase HPLC, which phases are paired?
Correct answer: Hydrophobic stationary phase with polar mobile phase. Reversed-phase HPLC pairs a hydrophobic stationary phase with a polar mobile phase, so the least polar analytes stick longest: the reverse of normal-phase chromatography. - Lead levels in drinking water are best determined using which technique?
Correct answer: AAS. Atomic absorption spectroscopy is the go-to for lead in drinking water because it measures the element itself at trace levels with little interference. - Which technique is used for monitoring dioxin levels in the environment?
Correct answer: GC-MS. Dioxins are volatile, fat-soluble trace contaminants, so gas chromatography with mass spectrometry, high separation plus definitive mass identification, is the standard monitoring technique. - Which statement about the SDS-PAGE technique is INCORRECT?
Correct answer: It is a type of gas chromatography. SDS-PAGE is a gel electrophoresis method that separates proteins by size after SDS denaturation, so calling it a type of gas chromatography is the incorrect statement. - The Beer-Lambert law gives a linear relationship with positive slope between which two quantities?
Correct answer: Absorbance and concentration. The Beer-Lambert law says absorbance rises in a straight line with concentration, a linear plot with a positive slope that makes absorbance a direct measure of how much analyte is present. - Which substance is commonly used as the mobile phase in GC-MS?
Correct answer: Helium. Helium is the standard GC-MS carrier gas: inert, so it never reacts with analytes, and light enough to sweep them cleanly through the column into the mass spectrometer. - Mass spectrometers separate isotopes based on their what?
Correct answer: Mass divided by electric charge. A mass spectrometer separates ions by their mass-to-charge ratio, m/z: neither mass nor charge alone decides the flight path. - Which gas is unsuitable for use as a GC carrier gas?
Correct answer: Oxygen. Oxygen is unsuitable as a GC carrier gas because it is reactive and would oxidize analytes, the stationary phase, and hot metal parts, while nitrogen, helium, and hydrogen are inert choices. - Slow injection of a large sample volume results in what?
Correct answer: Decreased resolution. A slow, large-volume injection smears the sample into a wide band at the column head, and that broad starting band degrades resolution. - An ion-exchange resin is composed of which of these?
Correct answer: All of these. An ion-exchange resin is a polymeric network carrying ionic functional groups with their counter-ions: all three parts working together. - The chemical oxygen demand (COD) measures which of these?
Correct answer: Oxygen needed to oxidize pollutants. Chemical oxygen demand measures the oxygen needed to chemically oxidize the pollutants in water, a gauge of total oxidizable contamination, not of microbial growth or dissolved oxygen itself. - In ion-exchange chromatography, proteins are separated on the basis of their what?
Correct answer: Net charge. Ion-exchange chromatography separates proteins by net charge: proteins bind the oppositely charged resin and release as salt or pH gradients shift. - Which of these may be added to stabilize a protein after yeast cell disruption?
Correct answer: All of these. After yeast disruption, sodium chloride for ionic stability, a protease inhibitor to stop proteolysis, and AMP as an allosteric stabilizer can each help, so all three may be used. - Gel-filtration chromatography separates molecules on the basis of what?
Correct answer: Size and shape, using porous beads. Gel-filtration chromatography sorts molecules by size and shape as they move through porous beads: large molecules bypass the pores and elute first. - Affinity chromatography is based on which principle?
Correct answer: Specific binding of a protein to another molecule. Affinity chromatography works on specific binding: the target protein alone locks onto its immobilized ligand while everything else washes through. - Protein separation can be carried out on the basis of which of these?
Correct answer: All of these. Protein separation can exploit net charge in ion exchange, solubility in salt solutions in salting out, and size or mass in gel filtration: all of these principles are in routine use. - When the target protein is an enzyme of energy metabolism, the best way to locate it across purification steps is to measure which of these?
Correct answer: Rate of ATP synthesis. When the target is an enzyme of energy metabolism, such as an ATPase, its catalytic activity, the rate of ATP synthesis, is the specific signal that pinpoints which fractions hold it across purification steps. - Which solvent is used for the estimation of fat content?
Correct answer: Ether. Fat content is estimated by extracting the lipid with ether, as in the Soxhlet method, since ether dissolves fats while leaving proteins and carbohydrates behind.